Home

Network Management Card Minislot

image

Contents

1. e EMC 89 336 EEC and 93 68 EEC Federal Communication Commission FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated ina commercial environment Cipa Pp pasaika OF Crioman Gates The information presented in this manual is also available in other languages at www eaton com powerquality 34003905EN AF
2. connection the card will restart keeping the settings IP SETTINGS Once the card has started proceed as indicated below Connect the serial cable to card s service port and PC s COM port e Use a terminal emulator such as HyperTermina settings Bits per second Data bits Stop bits Parity Flow control ITM with these o je ji non none Echo typed characters locally option disabled Type admin The main configuration menu is displayed EATON NETWORK MANAGEMENT CARD 1 Reset Network configuration Set Login Password to Default Return to Default Configuration Exit Your network is equipped with a BOOTP DHCP server default The card is configured by default with this service enabled No manual configuration is required The IP parameters are automatically collected by the card From the main configuration menu see above Press the 2 key Network configuration Press the 1 key Read Network settings The settings supplied by the server are displayed Network configuration MAC address 00 20 85 FD 1C 07 Mode DHCP IP address 166 99 23 18 Subnet mask 255 255 248 0 Gateway 166 99 17 e Note the IP address e Press the 0 key Exit e Press the 0 key Exit You can also use NMC Tool software utility to view the card IP adress The tool is available at download eaton com It must be installed on a network connected PC Your network is not equipped with
3. 905EN AF USER MANUAL TECHNICAL CHARACTERISTICS a i Aai sn ae i to install and Physical characteristics contigure the Networ anagement Card 9 9 Dimensions W x D x H 132 x 66 x 42 mm Fat ii E a s nn configuration functions offered by the Network Management Card 100 compatible see the user manual available at www eaton com powerquality Storage Storage temperature 10 C to 70 C range Ambient conditions SENSOR CONNECTION option Operating temperature 0 C to 40 C The Environment sensor is a Network Management Card range option It is available from EATON cat no 66846 The sensor remotely monitors the UPS environment by regularly measuring the temperature and humidity and checking the states of two external contacts It can also send alarms e mail SNMP 5V 5 trap tripped by pre set thresholds Supply current all LEDs 300 mA max i ON and Environment Connection is made via the Service port Settings Sensor on the Sensor connected Network Management Card The sensor is detected automatically Configuration and supervision use a menu that may be accessed directly from the home page For more information see the user manual of the Network Management Card Relative humidity 90 RH max without condensation Card performance Supply voltage Web supervision 5 browsers max http 3 browsers max https Languages English French German Italian Spanish E mail SNMP TRAP We
4. a BOOTP DHCP server Manual configuration is required To set the network configuration use terminal emulation see above From the main configuration menu Press the 2 key Network configuration e Press the 2 key Modify Network settings Follow the instructions and enter the IP parameters Read Network settings Modify Network settings Set ethernet speed Exit For each of the following questions you can press Return to select the value shown in braces or you can enter a new value Should this target obtain IP settings from the network N N Static IP address 166 99 16 16 166 99 1 82 Subnet mask IP address 255 255 0 0 255 255 255 0 Gateway address IP address 0 0 0 0 166 99 17 1 Done Wait until Done is displayed indicating that the IP parameters have been saved e Press the 0 key Exit e Press the 1 key Reset e Press the 2 key Restart The card restarts with the new IP settings after approx one minute ACCESS TO SUPERVISION To check whether the Network Management Card is operational after installation and IP settings proceed as follows e Run a browser e Enter in the address bar http IP address e g http 166 99 1 82 e The home page is displayed Network Management Cara Seca caps laren Paka Dana aqa inak Tiry mana Lasi ene SE H iiki e Set the time by clicking the Time command e Continue configuration via the sections in the Settings menu 34003
5. b page Log 400 measurements or events Alarms Server protection Up to 100 servers protected Network Fast ETHERNET 10 100 Mbits auto negotiation HTTP 1 1 SNMP V1 NTP TFTP SMTP BOOTP DHCP User name and password SSL 3 0 TLS 1 0 Microsoft Internet Explorer 6 x or higher ETHERNET Identification Security Browsers z lt N Enterprise Power Manager EPM Management Pac 2 MIB Il standard UPS EATON MIB V1 7 Settings default values IP network BOOTP DHCP enabled IP address 166 99 16 16 manual configuration Subnet mask 255 255 0 0 Gateway 0 0 0 0 NTP server pool ntp org User name admin Password admin Web page access control Service port menu access Password admin not control modifiable Synchronise with an NTP server GMT 9600 bits s 8 bits 1 bit stop no parity Nehrork Management Card Date and time Service port re Ba m Min FFA pore on OGRE ao biar FEF rected oni SOLS a ELECTROMAGNETIC COMPATIBILITY When correctly installed and used in accordance with 46 1 mos manufacturer instructions the card complies with the following PTET TTT ITTITITI kid Bir E T a recorded on SOLS 3 45 45 standards Ber PE nore Gri ERS IN a YD e ITE Information Technology Equipment safety IEC EN 60950 1 2002 e EMC EN 61000 6 2 2002 EN 61000 6 3 2002 IEC EN 62040 2 2002 In compliance with European directives Low voltage 73 23 EEC and 93 68 EEC
6. twork but no activity e Flashing Port is sending receiving 100M Orange e OFF e Port operating at 10 Mbits s e ON e Port operating at 100 Mbits s CH ECK ON U PS VERSION Service EEE TEEN Important Before installing the card check that the UPS Data eta FR e Card starting AN technical level NT is at least equal to that indicated in sii are with UPS the compatibility list For latest information check oN oe ene ok ore I Communication with UPS is www eaton com powerquality operational RS232 Orange e OFF e Configuration menu activated e ON e Normal operation Note Configuration menu not activated e If the technical level of the UPS is lower than that indicated in the e Flashing e Communication with Environment compatibility list contact EATON Sensor option 34003905EN AF INSTALLATION The Network Management Card can be hot plugged on all UPSs compatible with the card It is not necessary to shutdown the UPS disconnect the load or restart the UPS e Remove the plastic cover of the Minislot e Note the MAC address of the card before inserting it ETHERNET Insert and secure the card with the screws Connect the ETHERNET cable Check the ETHERNET port indications Wait until the UPS Data LED flashes regularly approx two minutes indicating that card start up has terminated correctly Nota You can set the parameters via Service port even if the network is not connected At
7. www eaton com Network Management Card Minislot Installation manual ETN Powering Business Worldwide 3V N3S06800tS UIO9 UO B8 AAAAAA ap mppom ssauisng Buuamog Ne L 3 INTRODUCTION OVERVIEW The Network Management Card is recommended for central UPSs protecting entire networks or for UPS units backing up critical loads With the card installed the UPS has its own IP address and uses the local computer capabilities to e Supply web pages http or https SSL with information on status conditions and measurements settings alarms e Integrate an SNMP based NMS such as HP OpenView IBM Tivoli Netview and Computer Associates Unicenter e Communicate with the protection software installed on the protected servers Network Shutdown Module or Netwatch Send e mail and SMS messages e Control the ON OFF function of the UPS and the outlets e Monitor the Environment Sensor optional cat no 66846 MAC address 20 0 1 G4 S8 02 00 ETHERNET 10 100BT port Service port Settings Sensor Orange LED RS232 activity UNPACKING AND CHECKS e One Network Management Card One serial cable for configuration 34003918 e One installation manual 34003905 Green LED communication with the UPS Orange LED 10 100M Green LED connection activity INDICATIONS ETHERNET port LED Colour Status Description _ Green e OFF e Card not connected to network e ON e Card connected to ne