Home

Signal conversion board for analog I/O SC

image

Contents

1. F 261 0 L oa 10 e E E v 249 8 p gt mm The L of the physical dimensions corresponds to the length from the outer surface of the slot cover to the outside of the opposite slot cover The H of the physical dimensions corresponds to the length between the upper and the lower ends of the slot cover Figure 10 Physical Dimensions CONTEC SC AIO1604G 15 SC AIO1604G User s Manual Specifications The following specification shows the signal for the signal conversion For more details on the other signal refer to the spec of analog I O board to be used or connector pin assignment For the connector pin assignment on external device CN1 and on analog I O board CN2 refer to the page 8 Connection Method Table 1 Specifications Specification channels 1 channels 1 I O range External device side CN1 Bipolar 10V 5V 2 5V Unipolar 0 10V 0 5V 4 20mA Supports range settings via jumper for each channel Analog I O board side CN2 Bipolar is fixed to 10V 2 Input bandwidth 500kHz Max Counter section fue Phase Z CLR 1 x 2 channel When using TTL 1MHz Phase difference 4MHz When using Optocoupler isolation 500kHz Input specification External device side CN1 Non isolated TTL level or Optocoupler isolated input 12 24VDC set by jumper Analog I O board side CN2 Non isolated TTL leve Control outp
2. i External device i I O signal D al i Conversion from 10V 1 5V analog signal i g 2 5V analog signal ip Input Signal Conversion Voltage to be input is fixed to 10V so you cannot use input value as it is It is necessary to convert input value according to range to be used You can convert input value by using the formula as illustrated below dy v 20 A Input value from external device B Conversion value from signal conditioner Range to be used 10 V 2 4 20 mA Conversion example Conversion of input value when you use range 4 20 mA and O V is input to board is as follows A Brody gt 20 a 0 15 x16 20 A 12 mA CONTEC 14 SC AIO1604G SC AIO1604G User s Manual Output Signal Conversion Voltage to be output is fixed to 10V so you cannot use output value as itis It is necessary to convert output value according to range to be used You can convert output value by using the formula as illustrated below Avx 20 y B A Output value to be output from signal conditioner to external device B Output value from board to be output the output value of A Range to be used 10 V 2 2 5 Conversion example Conversion of output value when you use range 5 V and 2 5 V is output to external device is as follows B A x x20 y go 2 5 5 x20 ET 10 B 5 V Physical Dimensions
3. Analog Ground Analog Input 05 96 48 I B14 B1 BL B08 BO Bor 14 Analog Ground Analog Input 04 Analog Ground Analog Input 03 Analog Ground A08 Analog Input 02 Analog Ground Analog Input 01 Analog Ground Analog Input 00 B04 Analog Ground Analog Output 01 Bo Analog Ground Analog Output 00 Figure 7 Pin Assignments of Interface Connector CN1 lt 1 2 gt CONTEC SC AIO1604G SC AIO1604G User s Manual Digital output signal The numbers correspond to channel numbers Digital ground common to digital input output signal external trigger Digital Ground input signal external sampling clock input signal counter input output signal AI External Sampling Clock Input External sampling clock input signal for analog input AI External Stop Trigger Input External trigger input signal for stopping analog input sampling AI External Start Trigger Input External trigger input signal for starting analog input sampling AI Control Signal Output00 Control signal for analog input The numbers correspond to channel AI Control Signal Output01 numbers AO External Sampling Clock Input External sampling clock input signal for analog output AO External Stop Trigger Input External trigger input signal for stopping analog output sampling AO External Start Trigger Input External trigger input signal for starting analog output sampling AO Control Signal Output00 Control signal
4. B21 4i 4i 4 4 2 2 B B 5 Digital Output 00 B18 Digital Output 00 Digital Output 01 B22 Digital Output 01 i B16 Digital Output 02 B25 Digital Output 02 B Digital Output 03 B26 Digital Output 03 B14 B27 Digital Output 04 BI B28 Digital Output 05 BI BIT 50 Bos BOT AO External Sampling Clock Input B06 AO External Stop Trigger Input 8 6 4 2 6 4 15 3 B31 B32 B34 B33 Digital Output 06 Digital Output 07 Si ut00 AO Control Signal OutPut01 AO External Sampling Clock Input zzz EIEIE EE E12 BJEJE EJEJE E 9 EEE ELE ELE amp 8 amp s s HHHHEHHE fart Fan Far faa Far fad bg z s s z s e 2 Analog Input 15 Range conversion circuit 5 E g B B p 3 F B37 B35 2 8 3 d 8 a H CNT Input A1 305 conversion circuit conversion circuit conversion circuit E E 313 mim EJES SIE BIE m a 2 ES 8 R E 3 B01 CNT Output 01 CNT Output 01 Analog Ground A02 A04 A06 A08 A10 A Analog Ground 12 A14 A16 A18 A20 B0 2 B04 B06 B08 B10 B12 B14 B16 B18 B20 B27 B28 B29 B31 B33 B34 B35 B37 B39 B40 B41 B43 B45 B47 A08 A19 Digital Ground B19 B20 6 A Digital Ground 38 A40 B23 B24 B29 B3 0 B36 B38 B40 GCONTEC 8 SC AIO1604G SC AIO1604G User s Manual Connector Pin Assignment on External Device CN1 Pin Assignments of Interface Connector CN1 Plus common 01 Minus common 01 INT Output 00 CNT Output 01 Pl
5. for analog output The numbers correspond to channel AO Control Signal Output01 numbers CNT Input A0 CNT Input A1 d i phase input signal The numbers correspond to channel CNT Input B0 CNT Input B1 Counter B phase input signal The numbers correspond to channel numbers CNT Input Z0 CNT Input Z1 Ie i A paese input signal The numbers correspond to channel No connection to this pin Figure 7 Pin Assignments of Interface Connector CN1 lt 2 2 gt A CAUTION There is a difference in pin assignments between CN1 and CN2 so you need to connect the cable carefully If you do not so it may cause failure Do not connect any of the outputs and power outputs to the analog or digital ground Neither connect outputs to each other Doing either can result in a fault If analog and digital ground is shorted together noise on the digital signals may affect the analog signals Accordingly analog and digital ground should be separated CONTEC 10 SC AIO1604G SC AIO1604G User s Manual Connector Pin Assignment on Analog I O Board CN2 Pin Assignments of Interface Connector CN2 Analog Output 03 Analog Input 13 Analog Ground Analog Ground s Digital Output 02 pi Digital Output 03 B15 Digital Output Digital Input 05 Digital Output 06 Bi AO Control Signal OutPut00 AO Control Signal OutPut01 AO External Sampling Clock Input AO External Stop Trigger Input AO External Start Trigger Input B05 The num
6. v i Plus L External T i common i power E i supply ima Optocoupler Ne o o o0 12 24VDC Input pin Switch i i i H Figure 2 Connecting counter input signal CNT Input A0 A1 BO B1 Z0 Z1 at the time of isolation setting External signal SC AIO1604G h ppes Source side i Plus External Va power Load T supply Fe oad 12 94VDC Optocoupler Minus common bee Figure3 Connecting control output signal CNT Output 00 01 at the time of isolation setting CONTEC 6 SC AIO1604G SC AIO1604G User s Manual Connection at the time of non isolation setting External power supply O 5V DC SC AIO1604G External device Es Pulus TALS541 Diode common Internal circuit Output pin Minus common Figure 4 Connecting counter input signal CNT Input A0 A1 BO B1 Z0 Z1 at the time of non isolation setting SC AIO1604G External device Internal Vec circuit 1i e 7ALS541 B a fo Output TTL level input Ground Ground Figure 5 Connecting control output signal CNT Output 00 01 Connection Example to TTL level Input circuit at the time of non isolation setting External power supply SC AIO1604G pulus common Internal circuit 74LS541 Open Collector output Current sinking Input Grou
7. Optional Analog M series AIO 121601M PCI 1 Analog F series AIO 163202F PE 1 ADA16 32 2 PCDF 1 ADA16 32 2 CB F 2 Analog L series AI 1664LA LPE 2 AD16 64 LPCDLA 2 The user must prepare the connecting cable about a product other than the above For more details on signal pin assignment refer to the manual of board that you use 1 PCB96PS 0 5P PCB96PS 1 5P optional cable is required separately 2 ADC 68M 96F optional cable is required separately Box Optional Box for signal conversion board ESC 4 1 ESC 4is required to use this product Cables Optional lt External device side CN1 and analog I O board side CN2 gt Shield Cable with 96 Pin Half Pitch Connectors at Both Ends PCB96PS 0 5P 0 5m PCB96PS 1 5P 1 5m lt External device side CN1 gt Shield Cable with 96 Pin D SUB Connector at One End PCA96PS 0 5P 0 5m PCA96PS 1 5P 1 5m Analog I O board side CN2 68 96 pin conversion shielded cable for analog input output ADC 68M 96F 0 5m CONTEC SC AIO1604G 13 SC AIO1604G User s Manual Signal Conversion This product performs signal conversion as illustrated below and corresponds to several kinds of signal sources Input Using example in 4 20mA Output Using example in 5V Range between boards is fixed to 10V I O range with external device is set by JP OV analog signal i 12mA analog signal Conversion to 10V pl iii
8. Signal conversion board for analog I O SC AIO1604G User s Manual CONTEC CO LTD Thank you for purchasing the CONTEC product The product consists of the items listed below Check with the following list that your package is complete If you discover damaged or missing items contact your retailer Product Configuration List User s Manual Board 1 User s Manual 1 E User s Manual Board AN CAUTION Use this product in the specified environment temperature and humidity Do not use or store the product in a location exposed to extremely high or low temperature or susceptible to rapid temperature changes Forexample Do not exposure to direct sunlight n the vicinity of a heat source CONTEC will bear no responsibility for any problems etc resulting from modifying this product When carrying the product be careful not to apply direct vibration or shock to the product The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statements CONTEC is not liable for any damages whatsoever including damages for loss of business profits arising out of the use or inability to use this CONTEC product or the information contained herein Other produ
9. Switching the range can be done using the jumper For setting the analog output range configure the jumper according to the table below Analog Output Voltage Output 10V Factory setting Voltage Output 5V E e 1 2 short Voltage Output 2 5V 2 short 1 Voltage Output OV 10V 1 2 short o 0 Voltage Output OV 5V 5 o 1 2 short 0 Nm co wo co wo Current Output 4mA 20mA 2 3 short Correspondences between the jumpers and channels in the above table are summarized in the table below TA Channel 00 Channel 01 Channel 02 Channel 03 JPA JP 25 JP 26 JP 63 JP 64 Ex The jumper settings in the right figure shows ool 00 the output range of the channel 0 set to 10V loo oo B foo foo zi oo 00 JP25 JP27 JP29 CONTEC SC AIO1604G 5 SC AIO1604G User s Manual Setting the Counter For the counter isolated non isolated connection is supported for each channel Switching between isolated unisolated can be done using the jumper For setting the counter configure the jumper according to the table below Isolation Unisolation 123 1 2 short Factory setting For the jumper settings that correspond to the channels refer to the tables below Ensure that all of the 8 jumpers are set to the same JP 52 JP 56 Connection at the time of isolation setting E External signal SC AIO1604G lt Tee i
10. bers in square brackets are pin numbers designated by HONDA TSUSHIN KOGYO CO LTD Figure8 Pin Assignments of Interface Connector CN2 1 2 gt GCONTEC SC AIO1604G 11 SC AIO1604G User s Manual Digital output signal The numbers correspond to channel numbers Digital ground common to digital input output signal external trigger Digital Ground input signal external sampling clock input signal counter input output signal AI External Sampling Clock Input External sampling clock input signal for analog input AI External Stop Trigger Input External trigger input signal for stopping analog input sampling AI External Start Trigger Input External trigger input signal for starting analog input sampling AI Control Signal Output00 Control signal for analog input The numbers correspond to channel AI Control Signal Output01 numbers AO External Sampling Clock Input External sampling clock input signal for analog output AO External Stop Trigger Input External trigger input signal for stopping analog output sampling AO External Start Trigger Input External trigger input signal for starting analog output sampling AO Control Signal Output00 Control signal for analog output The numbers correspond to channel AO Control Signal Output01 numbers CNT Input A0 CNT Input A1 d i phase input signal The numbers correspond to channel CNT Input B0 CNT Input B1 Counter B phase input signal The numbers corr
11. ct and product names are trademarks of their respective holder GCONTEC SC AIO1604G 1 SC AIO1604G User s Manual About the Product Signal Conditioner SC Series can reduce the type and number of measurement control board of PC side by converting the signal and circuit being coexisted by the signal and circuit spec when measuring and controlling with multiple external devices You can easily build the system without the original circuit by using the Signal Conditioner SC Series conversion board This product is a signal conversion board for a signal conditioner signal conversion SC Series analog I O For each channel this product can be set by using one of 6 types of range Bipolar 10V 5V 2 5V Unipolar 0 10V 0 5V 4 20mA according to the analog input output signal on the external device According to the counter signal on external device this product can be set to isolation non isolation for each channel Features Range settings for each channel are supported according to the analog signal on external device According to the analog signal on external device range settings Bipolar 10V 5V 2 5V Unipolar 0 10V 0 5V 4 20mA can be done for each channel In the analog signal from the external device side all the setting ranges are converted to the voltage of bipolar 10V and then are output to the PC side analog I O board In the analog signal from the PC side analog I O board the volta
12. espond to channel numbers CNT Input Z0 CNT Input Z1 Ie i A paese input signal The numbers correspond to channel No connection to this pin Figure 8 Pin Assignments of Interface Connector CN2 lt 2 2 gt A CAUTION There is a difference in pin assignments between CN1 and CN2 so you need to connect the cable carefully If you do not so it may cause failure The signal names on the CN2 correspond to those on the CN1 Therefore the input signals on the CN2 are actually the output signals from the CN1 and the output signals are the CN1 input signals Avoid causing a short circuit by connecting the input signals with the analog ground or the digital ground Also avoid connecting the input signals to each other Doing either can result in a fault Unused output signals must be short circuited with the ground for stable operation CONTEC 12 SC AIO1604G SC AIO1604G User s Manual Inserting to the box for the signal conversion board Insert this product referring to the documentation of the box for the signal conversion boards Board Card Connection Board Card side Cable 1 CN2 ESC 4 CN1 Cable 2 Sold separately Sold separately 9351 s I Analog Input board External device side Analog card le Figure 9 Connecting to the board card I d Correspondence Products
13. ge of bipolar 10V range is converted to the voltage current of setting range and then output to the external device side Switching the range can be done using the jumper According to the counter signal on external device isolated non isolated settings can be done for each channel According to the counter signal on external device this product can be set to isolation non isolation for each channel Counter signal to the PC analog I O board side is non isolation Switching the range can be done using the jumper A CAUTION Note that you cannot use AIO 163202F PE ADA16 32 2 PCI F ADA16 32 2 CB F AI 1664LA LPE AO 1608L LPE AO 1616L LPE AD16 64 LPCDLA DA16 8 LPCDL DA16 16 LPCI L in the specification exceeding that of signal conditioner I O boards by analog F L series correspond to the up count operation and those of analog M series correspond to the up down count operation CONTEC 2 SC A101604G SC AIO1604G User s Manual Setup Hardware Name of each parts Figure 1 shows the names of major parts on the board Analog input range setting jumper Analog output range setting jumper JP1 JP24 JP 31 JP50 JP59 JP62 JP25 JP30 JP 63 JP68 o Qo ERR iid A Interface connector CN2 Isolation unisolat
14. ion setting jumper for counter JP51 JP58 JP69 JP76 Interface connector CN1 Figure 1 Component Locations CNI1 The connector that connects with the external device side CN2 The connector that connects with the PC analog I O board side GCONTEC SC AIO1604G SC AIO1604G User s Manual Setting Method Setting the Analog Input Range The analog input range can be set for each channel Switching the range can be done using the jumper For setting the analog input range configure the jumper according to the table below Analog Input Voltage Input 10V Factory setting Voltage Input 5V Voltage Input 2 5V Voltage Input OV 10V Voltage Input 0V 5V Current Input 4mA 20mA 2 3 short 4 8 short Correspondences between the jumpers and channels in the above table are summarized in the table below Channel 00 Channel 01 Channel 02 Channel 03 Channel 04 Channel 05 Channel 06 Channel 07 JPA JP1 JP2 JP 7 JP 8 JP 13 JP 14 JP 19 JP 20 I Channel 08 Channel 09 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 JPA JP 31 JP 32 JP 37 JP 38 JP 43 JP 44 JP 49 JP 50 Ex The jumper settings in the right figure shows f B loo 7 loo ii the input range of the channel 0 set to 10V co loo oo gp A leol JP3 JP5 CONTEC 4 SC AIO1604G SC AIO1604G User s Manual Setting the Analog Output Range The analog output range can be set for each channel
15. nd Figure 6 Connecting control output signal CNT Output 00 01 Connection Example to isolation input circuit at the time of non isolation setting CONTEC SC AIO1604G 7 SC AIO1604G User s Manual Connection Method Signal Connection Analog I O board side CN2 External device side CN1 AOL A03 A05 A07 A09 All A13 gt Z E 5 E z s ele BE B E HJE EE HE BIE Slo A2 Analog Input 01 As alos Input 0 Analog Input 01 gt 5 EN 5 R z 3 8 Analog Input 03 Analog Input 04 A17 A19 Analog Input 06 A05 AT External Start Trigger Input 2 A30 Analog Input 05 A15 Analog Input 05 5 gt 5 EN 5 R z S lSlelElelelele 8 18 18 5 S J8 18 EjeJeE JE EE EIE slslelslsjels EYES IEEE EE SEIE IEEE EE SJSJSJE Byes A21 A22 A25 Digital Input 03 A27 A28 a 5 A31 A32 AI Control Signal OutPut00 AT Control Signal OutPut01 AI External Sampling Clock Input A34 A39 A3 A35 E Isi E E iz E 8 fer E 8 F E E E m a 8 E n E a Ei 5 8 E A04 CNT Input A0 A45 CNT Input AO conversion circuit conversion circuit A02 CNT Input Z0 Tsolation non isolation conversion circuit AOL CNT Output 00 CNT Input ZO CNT Output 00 nm R E SI Ej amp gt z z 5 3 z 3 8 gt gt HE BJE HE JE HH BIE ols Ris B B B B 3 Bo nator input 15 DE Analog Input 14 Du B19
16. us common 00 Minus common 00 Digital Ground AO External Sampling Clock Input Digital Ground AO External Stop Trigger Input Digital Ground AO External Start Trigger Input AO Control Signal OutPut00 AO Control Signal OutPutO1 Digital Output 07 Digital Output 06 Digital Ground Digital Ground Digital Output Digital Output 04 Digital Output 03 Digital Output 02 Digital Ground Digital Ground Digital Output 01 Digital Output 00 Analog Ground og Input Analog Ground Analog Input 14 Analog Ground Analog Input 13 Analog Ground nalog Input 12 nalog Ground Analog Input 11 Analog Ground Analog Input 10 Analog Ground nalog Input 09 nalog Ground Analog Input 08 Analog Ground Analog Output 03 nalog Ground Analog Output 02 The numbers in square brackets are pin numbers designated by HONDA TSUSHIN KOGYO CO LTD B48 CNT Input Z1 CNT Input Al SNT Input B1 ONT Input A0 ONT Input ZO SNT Input BO B45 44 2 B40 A40 B3 B Digital Ground AI External Sampling Clock Input Digital Ground AI External Stop Trigger Input Digital Ground carn 34 AI Control Signal OutPut01 A33 AI Control Signal OutPut00 39 Digital Input 07 3 Digital Input 06 0 Digital Ground Digital Ground Digital Input 05 Digital Input 04 Digital Input 03 Digital Input 02 Digital Ground Digital Ground Digital Input 01 Digital Input 00 Analog Ground BI B18 B1 Analog Input 07 Analog Ground Analog Input 06
17. ut section Output specification External device side CN1 Non isolated TTL level or Optocoupler isolated output 12 24VDC set by jumper Analog I O board side CN2 Non isolated TTL leve Common section Adjustment accuracy 1mV Max 3 4 96 pin half pitch connector F Female typel x 2 PCR E96LMD HONDA TSUSHIN KOGYO CO LTD or equivalence to it 0 50 C 20 80 RH No condensation CONTEC 16 SC AIO1604G SC AIO1604G User s Manual 1 The number of available channel depends on the analog input board to be used 2 External signal output from board is fixed to 10V in any range External signal input to board is fixed to 10V in any range 3 There may be maximum of 1mV error during a full scale use 4 An error approximately 0 15 of full range may occur when operated at 0 C or 50 C ambient temperature CONTEC SC AIO1604G 17 SC AIO1604G User s Manual CONTEC CO LTD February 2009 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan Japanese http www contec co jp English http www contec com Chinese http www contec com cn No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD 03272009 02032009 Management No A 51 630 03272009 rev2 Parts No LYJW992