Home
User manual Arc Power 48
Contents
1. DMX Input DMX Output Pin 1 Not connected Pin 5 Not connected Pin 2 Not connected Pin 6 Data Pin 2 Not connected Pin 6 Data Pin 3 Not connected Pin 7 Data Pin 3 Not connected Pin 7 Data Pin 4 Not connected Pin 8 GND Pin 4 Not connected Pin 8 GND Pin 1 Not connected Pin 5 Not connected RJ45 socket Front view of the socket LED module Input Pin 1 LED colour 1 Pin 5 LED colour 1 Pin 2 LED colour 2 Pin 6 LED colour 2 Pin 3 LED colour 3 Pin 7 LED colour 3 Pin 4 LED colour 4 Pin 8 LED colour 4 RS232 Input Pin 1 Not connected Canon 9 pin male Pin 2 Received Data Front view of the socket Pin 3 Transmitted Data Pin 4 9 O Pin 5 Signal Ground Pin 6 Pin 7 Pin 8 Pin 9 Not connected 4 Installation 4 1 Connection to the mains The ArcPower 48 is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions The earth has to be connected Cord plug connections Brown Live Light blue Neutral Yellow Green Earth This device falls under protection class I Therefore the ArcPower 48 has to be con nected to a mains socket outlet with a protect
2. 7 ArcPower 48 DMX protocol version 2 0 software version 2 1 and higher Mode Channel Type ceca CN NN RED LEDs Single colour LEDs 1 0 255 Red LEDs saturation control 0 100956 proportional GREEN LEDs Single colour LEDs 2 0 255 Green LEDs saturation control 0 100926 proportional BLUE LEDs Single colour LEDs 3 0 255 Blue LEDs saturation control 0 100946 proportional 4 4 WHITE LEDs Single colour LEDs 4 0 255 White LEDs saturation control 0 100 proportional MACRO SELECTION 0 7 No function step 8 15 Macro 1 step 16 23 Macro 2 step 24 31 Macro 3 step 32 39 Macro 4 step 40 47 Macro 5 step 48 55 Macro 6 step 56 63 Macro 7 step 64 71 Macro 8 step 72 79 Macro 9 step 80 87 Macro 10 step 88 95 Macro 11 step 96 103 Macro 12 step 104 111 Macro 13 step 112 119 Macro 14 step 120 127 Macro 15 step 128 135 Macro 16 step 136 143 Macro 17 step 142 151 Macro 18 step 152 159 Macro 19 step 160 167 Macro 20 step 168 175 Macro 21 step 176 183 Macro 22 step 184 191 Macro 23 step 192 199 Macro 24 step 200 207 Macro 25 step 208 215 Macro 26 step 216 223 Macro 27 step 224 231 Macro 28 step 232 239 Macro 29 step 240 247 Macro 30 step 248 255 Rainbow effect with variable speed proportional SHUTTER STROBE Shutter closed step Shutter open step Strobe effect from slow to fast proportional Shutter open step Opening pulses in sequences slow gt fast proportion
3. data in 3 Transmited data Pin 4 Pin 4 Pin 5 Signal ground Pin 5 Signal ground Pin 6 Pin 6 Pin 7 Pin 7 Pin 8 Pin 8 Pin 9 Pin 9 The maximum cable length according to the standard is 15 metres or the cable length equals to a capacitance of 2500 pF 9 2 Selecting a zone The number of the zone distinguishes individual drivers which are controled via RS 232 interface Select SPE in main menu of the ArPower 48 press ENTER use UP and DOWN buttons to select Zon The option enables to select desired number of the zone from O to 9 Press ENTER use UP and DOWN buttons to select zone number and press ENTER to confirm selection 9 3 Setting a serial port of PC The serial port of your personal computer hould be configured as follows 9600 Baud 8 Data Bits Non Parity One Stop Bit No Flow Control Required 9 4 Zone commands The ArcPower 48 uses the 3 types of the zone commands which can be used in a suitable software running on PC All zone commands stated below have to be send to the ArcPower 48 in ASCII codes Type 1 Selection of the preset colours The syntax of the command is zone Z red zone Z green 16 zone Z blue zone Z white zone Z yellow zone Z cyan zone Z magenta zone Z blackout Lice means number of the zone 0 9 red green blue white yellow cyan magenta determines colour blackout closes light output TI Eb m
4. dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to have both overload and short circuit protection 2 Operating determinations This product was designed for control of the ArcPad 48 only The fixture is intended for indoor use only If the unit has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your unit Leave the unit switched off until it has reached room temperature Avoid brute force when installing or operating the unit When choosing the installation spot please make sure that the unit is not exposed to extreme heat moisture or dust Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fas tened The maximum ambient temperature 40 C must never be exceeded Operate the unit only after having familiarized with its functions Do not permit operation by persons not quali fied for operating the unit Most damages are the result of unprofessional operation Please use the original packaging if the product is to be transported Please consider that unauthorized modifications on the unit are forbidden due to safety reasons 3 3 Description of the ArcPower 48 1 Control Board 2 Power Indicator 3 DMX Output 4 DMX Input 5 LED Module Input 6 RS 232 Input 7 Fuse Holder 8 Power Cord
5. ANOLIS ArcPower 48 USER MANUAL version 1 6 ArcPower 48 Table of contents T Safety INSIrUCIONG p ini 3 2 Operating determih lOorS ii td 3 3 Description of the ArcPower 48 cccscccsssssssseensseeeeneeeeeeeeeeseeeonenanenaaeeeenseseeeeseeseeaaqnnanen 4 ALAS MN 4 4 1 Connection to the Mains aussi iio o 4 4 2 Mounting the ArePOWOF 48 ccr prov A aa 5 AB Conestiom CAD itn a E c OE EROR apta cte toU B l vb tas 5 5 Installing InstructioNS A is 6 51 DND ODS AUN ERU le meso EE 6 5 2 Master Slave Opera do 8 5 3 Operating via DyNet protocol aaanaaaaaaaas naaaaanasnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 9 6 ArcPower 48 Control menu Map a222aaaaaaanannun vnnnnnnnnnnnnnnnnunununnnnnnnnnnnnnnnnnnnnnnnnnnnnnnuNNI 9 7 ArcPower 48 DMX protocol annnannunannuanunnn avavnnannnnnnnnnnnunnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnNNnnNnnnnnnaR 10 8 Control bar MS CC es 12 8 1 Addressing the ArcPower 48 2 tei Did un tet anio chee 12 8 2 Program FUNMING eT Vk a 12 8 3 Manual MOdE siii 13 G4 TES SS QUEEN Sia 14 8 5 Stand alone Modes s rotor dee Ep Odor desee xU Cope shine ctu ne cuba FR Rd NEA aaa aaa 14 8 6 Special TUMNCTIONS m exo onn E ivadv ad oie too 14 9 Control of the ArcPower 48 via RS 232 2uaaaaaannnnnnnnnnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 16 9 1Wiring an RS 232 serial port s oret epi ho ita lili 16 9 2 Sele
6. al Closing pulses in sequences fast gt slow proportional Shutter open step Random strobe effects from slow to fast proportional Shutter open step 7 4 DIMMER 0 255 Dimmer intensity from 0 to 100 proportional For single colour variant of ArcPad 48 only e g white 11 8 Control board The control panel situated on the top cover ofthe ArcPower 48 allows DMX addressing calling build in programs and setting the fixture behaviour Control display ccc LLLI OH lt A Y Control elements lt ENTER button enters menu confirms adjusted values and leaves menu Vv UP button and DOWN button moves between menu items on the the same level sets values In order to leave the menu without saving value press UP and DOWN at the same time After switching on the ArcPower 48 the display shows the initial DMX address l l LILI 1 Use UP DOWN to browse through the menu To select a function or submenu press ENTER 8 1 Addressing the ArcPower 48 l I LILI 1 The fixture can be uperatated in the two modes DMX mode fixture is controlled via DMX 512 by an external DMX controller Stand alone mode fixture uses build in programs and is able to control other fixtures in the master slave chain See the chapter Stand alone mode for detail description For DMX mode is important the DMX start address that is defined as the first channel from which the ArcPower 48 will respond to the DMX controller Settin
7. cting a ZONE s ok Oras TEE 16 9 3 Setting a Serial POr ob PO ricas laico leida M ta ha an ha an 16 9 4 ZONE CONAN vi a rav atta coc Kal A beha a NR a an la f Coe hut Bobo 16 10 TECNICA LS PECI ICA ION ai 18 11 Replacing the TUSE scooter 19 CAUTION Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this product has to be qualilfied follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires inside the unit This product has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual To prevent from danger of accident the device has to be fixed on flat non flamma ble surface in compliance with the installing instruction included in this manual Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the product Always ground the unit The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this unit to a
8. do not want to continue in software update you have to switch off and on the fixture to leave this option 3 It is recommended that you exit all programs before running the Software Uploader 4 Start the Software Uploader program Select desired COM and then click Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update All processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Update status is being displayed in the list window When the update is finished the line with the text The fixture is successfuly updated will appear in this window and the fixture will reset with the new software Note In the case of interruption of the upload process e g power cut the fixture remains in the update mode and you have to repeat the software update again 15 9 Control of the ArcPower 48 via RS 232 9 1Wiring an RS 232 serial port 9 pin D connector male Front view of the socket Pin 1 Not connected Pin 2 Received Data Pin 3 Transmitted Data 1 5 Pin 4 O O Pin 5 Signal Ground 6 9 Pin 6 Pin 7 Pin 8 Pin 9 Not connected RS 232 cable 9 pin D connector female 9 pin D connector female ArcPower driver o Pin 1 Pin 1 Pin 2 Received Data AA 2 Received Data Pin 3 Transmited
9. eans end of character sequence Examples zone 4 green zone O blackout Type 2 Colour mixing RGB The syntax of the command is zone Z r g b Zune means number of zone 0 9 onis means DMX value of the red colour 0 255 ginis means DMX value of the green colour 0 255 Dou means DMX value of the blue colour 0 255 EE means end of character sequence la values of colours have to be separated by a comma Examples zone 0 234 126 165 zone 1 5 18 28 Type 3 Colour mixing RGBW The syntax of the command is zone Z r g b w Zo means number of zone 0 9 Esos means DMX value of the red colour 0 255 dise means DMX value of the green colour 0 255 Diu means DMX value of the blue colour 0 255 W means DMX value of the white colour 0 255 METTE means end of character sequence SPD values of colours have to be separated by a comma Examples zone 0 156 145 171 211 zone 1 5 18 28 148 17 10 Technical Specifications Power supply Input Voltage version 100 240 V AC 50 60 Hz Fuse T 1 25A Max Pover Consumption 60 W Input Control DMX 512 DMX connection RJ45 RS 232 connection 9 pin D connector Output Max Output Voltage 48V DC Max Output current per colour channel 700mA for white green and blue LEDs 420 mA red LED Max load 48 Luxeon Rebel LEDs Maxi cable length between ArcPower 48 and ArcPad 48 40 metres DMX channels RGBW variant of the ArcPad 48 Channel Mode 1 Mode 2 Mode 3 Mode 4 M
10. ecksum Area 0 to 255 as set on the ArcPower to give a unique address for each ArcPower unit i e DMX base address Channel Level 0 to 255 level 01210096 FF 0 Channel 80 to 83 80 channel 1 81 channel 2 82 channel 3 83 channel 4 see Channel Offset if more than 4 channels Channel Offset 0 255 default FF channel offset in blocks of 4 FF CH 1 4 00 CH 5 8 01 CH 9 12 etc up to 3E CH 253 256 Fade Rate 0 255 fade rate with 1 second resolution 02 0 seconds 255 255 seconds Checksum 0 255 checksum Byte used to ensure the integrity of the packet Negative two s compliment of the preceding 7 bytes Example 1 0x1C 0x10 0x00 0x80 0xff 0x05 0xff 0x52 This would control channel 1 i e Red of ArcPower unit address 16 to a Level of 100 with a fade of 5 seconds Example 2 6 ArcPower 48 Control menu map Default settings Bold print 001 506 E P 1 E P 2 E P 3 P 01 P 10 Aut OFF On Edl An E P 1 E P 2 E P 3 S 01 S 50 End Ch 1 0 255 FA t 0 255 S tl 0 255 MAn COP Ch 1 0 255 Ch 2 0 255 Ch 3 0 255 Ch 4 0 255 MAC 0 255 Str 0 255 diM 0 255 MSt m E P 1 P10 SLA SPE P VEr bAL On OFF C bA rE b 0 200 Gr b 0 255 bL b 0 215 Zon Z 00 Z 09 d MP Mo 1 Mo 2 Mo 3 Mo 4 Mo 5 i bL On OFF Prt dMH dYn UPd No YES 10
11. effect press ENTER and and by using UP and DOWN buttons adjust desired DMX value for selected effect Confirm by ENTER Ch 1 a red LEDs single colour 1 saturation Ch 2 a green LEDs single colour 2 saturation Ch 3 a blue LEDs single colour 3 saturation Ch 4 a white LEDs single colour 4 saturation MAC a macro selection Str a strobe dim a dimmer For single colour variant of ArcPad 48 e g white 13 8 4 Test sequences Lou LL Use the item to run a special demo test sequences without an external controller which will show you some possibilities of using the fixture 8 5 Stand alone mode ZLO Sl l Select this menu to set fixture behaviour in stand alone mode without an external controller Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MSt and the rest as the slaves SLA Only one fixture can be set as the master The slaves mimic the behavior of the master Effect actions are triggered by an internal timer of the master fixture Important Disconect the fixtures from the DMX controller before master slave operating otherwise data col lisions can occur and the fixtures will not work properly MSt Master Enter this menu if you want to set the the fixture as a master Use UP and DOWN buttons to select desired program and press ENTER to confirm selection SLA Slave Enter this menu if you want to set the the fix
12. g the DMX start channel for DMX operating 1 Connect ArcPower 48 to the mains 2 Browse through the menu by pressing the UP and DOWN buttons until the display shows current addres 001 Confirm by pressing ENTER button and 001 will start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed the ArcPower 48 you may now start operating the ArcPower 48 via your DMX control ler 8 2 Program running OP rs LI By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected by pressing ENTER Selected program runs in a loop The fixture includes 10 built in programs P 01 P 10 and 3 free editable programs E P 1 E P 3 each up to 50 steps If Item AUt is On the fixture in DMX mode will remember last running program and this program will run after switching on the fixture Each program step has a fade time the time during which effects go to the current step and a Standing time the time during which effects last in the current step current step j Fade time Standing time Programming procedure 12 1 Enter Edl menu 2 Press UP or DOWN to select the desired program which you wish to edit and press ENTER 3 Press UP or DOWN to select the desired program step S 01 S 50 and press ENTEH 4 Press UP or DOWN to select the desired item and press ENTER button No
13. ive earthing connection 4 2 Mounting the ArcPower 48 The ArcPower 48 should be be placed on a non flammable flat surface in any orientation and fixed by the two screws There are two mounting holes of diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated Screw Flat surface Mounting hole 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 48 to the DMX controller lf your DMX controller has RJ45 socket for DMX output use standard RJ45 patch cable for connection with the ArcPower 48 gN u W RJ45 plug DMX 512 XLR plug male View facing pins Front view of the plug D 1 Pin 1 Not used Pin 1 GND Pin 2 Not used Pin 2 Data Pin 3 Not used Pin 3 Data Pin 4 Not used Pin 4 Not used Pin 5 Not used Pin 5 Not used Pin 6 Data Pin 7 Data Pin 8 GND 2 RJ45 patch cables category 5 that connect the ArcPower 48 each other are wired 1 1 that is pins with the same numbers are connected together E M Pin 1 Not used Pin 1 Not used Pin 2 Not used Pin 2 Not used Pin 3 Not used Pin 3 Not used Pin 4 Not used Pin 4 Not used Pin 5 Not used Pin 5 Not used Pin 6 Data Pin 6 Data Pin 7 Data Pin 7 Data Pin 8 GND Pin 8 GND 5 Installing instructions 5 1 DMX
14. ode 5 1 Red LEDs Red LEDs Red LEDs Red LEDs Red LEDs 2 Green LEDs Green LEDs Green LEDs Green LEDs Green LEDs 3 Blue LEDs Blue LEDs Blue LEDs Blue LEDs Blue LEDs 4 White LEDs Macros White LEDs Dimmer 5 Shutter Strobe Macros 6 Dimmer Shutter Strobe 7 Dimmer Control and programming Protocol USITT DMX 512 Control options DMX Auto trigger Operation modes Master Slave Stand alone Programs 10 built in programs 3 user editable programs up to 50 steps each Display 3 digit LED White colour balance adjusting Manual control of all DMX channels with LED control panel Operating temperature 10 C 40 C Dimensions mm Weight 1 1kg X 18 Accessories Cable joiner 1piece No 13050691 Optional accessories Adaptor RJ45 DMX 3 pin No 13050730 Adaptor RJ45 DMX 5 pin No 13050731 11 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 48 with a fitting screwdriver from the housing anti clockwise 3 Remove the old fuse from the fuse holder 4 Install the new fuse in the fuse holder 5 Replace the fuse holder in the housing and fix it Specifications are subject to change without notice May 12 2015 19 20
15. operating 1 Unplug from the mains before installation 2 Connect the ArcPad 48 to the fixture 3 Connect DMX controller to the fixture 4 Connect the fixture to the mains 5 Set the DMX address on the control board of the fixture see chapter Control board Warning Accidental connection DMX 512 Input Output to non DMX 512 device e g Ethernet network Hub can damage the ArcPower 48 Maximum total cable length between ArcPower 48 and connected ArcPad 48 is 40 metres Single ArcPower 48 installation DMX controller DMX address 1 ArcPadPower 48 Multiple ArcPower 48 installation Connect the DMX output of the first ArcPower 48 with the DMX input of the next ArcPower 48 Always connect one output with the input of the next ArcPower 48 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 48 the data link has to be terminated with a terminator A termination plug is simply a RJ45 connector with a 120 resistor between pins Data and Data Plug terminator in the DMX output of the last ArcPower 48 ArcPadPower 48 5 a o m a E lt ArcPadPower 48 5 2 Master slave operating 1 Unplug from the mains before installation 2 Connect the ArcPads 48 to the fixtures 3 Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave un
16. pdate software in the fixture via PC and serial link The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ANOLIS distributor Note 2 DMX address programs and all settings will be set to their default values To update software in the fixture 1 Installation of DMX Software Uploader 1 DMX Software Uploader program is available from the ANOLIS web site at WWW anolis cz 2 Make a new directory e g ANOLIS Uploader on your hard disk and download the software to it 3 Unpack the program from the archives Program file has name DSU name of corresponding fixture SoftwarelD SoftwarelD describes the versions of fixture software included in DMX Software Uploader Higher number means later software versions 2 Fixture software updating 1 Determine which of your COM port is available on your PC and connect it with to the DMX input of the fixture using the Flash cable Do not extend this cable Disconnect the fixture from the other fixtures in DMX chain Turn on the computer and the fixture 2 Switch the fixture to the update mode by selecting the option Software update in menu Special Functions on the fixture control panel SPE gt UPd gt yES From this option you cannot return back to the main menu If you
17. til all slaves are connected Up to 32 fixtures can be connected in master slave chain 4 Insert the termination plug with 120 Ohm into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link 5 Connect the fixtures to the mains 6 See chapter Stand alone mode in order to set the fixture as a master or slave ArcPadPower 48 2 lt o 3 2 a o 4 ArcPadPower 48 5 3 Operating via DyNet protocol 1 Unplug from the mains before installation 2 Connect ArcPad 48 modules to the fixtures Connect first fixture to the control panel which uses DyNet protocol 3 Connect the DMX output of the first fixture in a data link with the DMX input of the second fixture Always connect output with the input of the next fixture until all fixtures are connected Up to 32 fixtures can be con nected in data chain 4 Insert the termination plug with 120 Ohm into DMX output of the last fixture in order to ensure proper trans mission on the data link 5 Connect fixtures to the mains 6 Select the DyNet protocol on all fixtures menu SPE gt Prt gt dYn A description of each byte in DyNet protocol is the following Byte 0 1C hexadecimal Logical Message fixed value Byte 1 01 Area Byte 2 00 Channel level Byte 3 80 Channel Byte 4 ff Channel Offset Byte 5 00 Fade Rate Byte 6 FF fixed value Byte 7 1C Ch
18. to adjust the new maximum value required for the red channel Confirm your choice by pressing ENTER Use the UP and Down buttons to select next colour 3 Repeat step 2 for green channel Gr b and for blue channel bL b Zon Zone selecting The number of the zone distinguishes individual drivers which are controled via RS 232 interface Use UP and DOWN buttons to select desired zone from 0 to 9 and press ENTER to confirm selection For futher information see chapter Control of the ArcPower 48 via RS 232 d MP DMX presetting The function enables to select from the 5 DMX channels settings Use UP and DOWN buttons to select desired channel mode Mo 1 Mo 2 Mo 3 Mo 4 Mo 5 and press ENTER to confirm selection i bL Initial blink If this function is on the ArcPower 48 performs auto calibration All LEDs of the ArcPad 14 48 light on 100 for short time after switching it on If this function is set off you have to set manually every colour on max brightness after switching on the driver before starting regular operating This action should last min one second In this moment the ArcPower 48 finds out the load connected to its LED output and makes auto calibration Prt Protocol selection Selects a required communication protocol dMH the fixture will communicate using DMX 512 signal dYn the fixture will communicate using the DyNet protocol UPd Software update Using this function you can u
19. ture as a slave To run a master slave operation switch on all drivers at the same time or switch on the slaves as first and then the master fixture The master fixture starts simultaneous program start in the other slave fixtures All fixtures are synchronized in every prog steps The fixtures run their programs repeatedly e g if master runs its program P05 all slaves will be executed program P05 too Note If the master runs its editable program EP1 EP2 or EP3 all slaves will execute their own editable pro grams EP1 EP2 or EP3 according the master but both fade time FA t and standing time S tl for each step will be taken from the master s step slaves times are eliminated in each step 8 6 Special functions SPE Use this menu for special services VEr Software Version Select this function to read the number of the fixture software bAL Balance Select this function to enable On or disable OFF the white balance which is set in White colour balance menu below If this function is set OFF ArcPower 48 will use maximum values 255 of satura tion for red green and blue channel C bA White colour balance Using this menu you can set white balance for RGBW variant of the ArcPad 48 1 Browse through the menu by pressing the UP and DOWN buttons until the display shows C bA menu Press ENTER button and rE b will appear on the display 2 Press ENTER button again and use UP and DOWN buttons
20. w you can edit by using UP or DOWN buttons the DMX values selected item the list of items depends on selected DMX mode End a total number of the program steps value 1 50 This value you must set before start programming e g if you want to create program with 10 steps set End 10 Ch 1 a red LEDs single colour 1 saturation value 0 255 Ch 2 a green LEDs single colour 2 saturation value 0 255 Ch 3 ablue LED single colour 3 saturation value 0 255 Ch 4 a white LED single colour 4 saturation value 0 255 For single colour variants MAC amacro selection value 0 255 of ArcPad 48 Str a strobe value 0 255 dim adimmer value 0 255 FA t fadetime value 0 255 S tl standing time value 0 255 COP copying the current prog step to the next prog step Press ENTER button to confirm adjusted value 5 Repeat steps 3 and 4 for next prog step If you want to copy current prog step to the next prog step select option COP and confirm it by pressing ENTER Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value Exact expression of the time value follows the formula ms DMX value 710 8 3 Manual mode rici 140101 This menu gives access to the control of the fixture channels by means of the control buttons Use UP and DOWN buttons until the display shows MAn menu Press ENTER button and by using UP and DOWN buttons select desired
Download Pdf Manuals
Related Search
Related Contents
DLM DH Manual May2014 HABILITADO DE ABERTURAS (PUERTAS O VENTANAS) Philips RI2630/51 M-500 - Phil Jones Test Report - Summit Data Communications Copyright © All rights reserved.
Failed to retrieve file