Home
FSW-1650 FSW-2450 User Manual 16/24 10/100
Contents
1. 40 C Storage Temperature 40 C 70 C Operating Humidity 10 90 non condensing Storage Humidity 5 95 non condensing FSW 1650 FSW 2450 Ra UU OR arelerireleln mes ACTO Appendix B Troubleshooting 1 The Power LED is not lit gt Make sure the AC power cord connected the Switch with power source properly gt Make sure the power source is ON 2 The Link Act LED is not lit when a device is connected to the corresponding port gt Make sure that the cable connectors are firmly plugged into the Switch and the device gt Make sure the connected device is turned on and working well gt The cable must be less than 100 meters long 328 feet
2. indicators The LED indicators include Power Link Act LED indicators which are used for monitoring and pre troubleshooting of the Switch The following section shows the LED indicators of the Switch along with an explanation of each indicator 7oOoo oe 00000 0 O lh 13 s F 8 4 13 iS WF t 21 2 SA Aononnpoooo00n 100Mbga J000 oO OO0O00 O O alk 2 4 8 B WW 12 14 16 18 2 2 N Ai FSW 2450 24 Port 10 100 Rackmount Switch Figure 3 3 FSW 2450 Switch LEDs sketch gt Power LED This indicator will light solid red when the Switch powers up If the LED is not lit please check the power supply and connection gt LINK ACT LED The LED indicates Link Active status The corresponding LED indicator will light solid green when connected to a network device It flashes green when data is being transmitted or received on the working connection gt 100Mbps The corresponding gigabit port LED indicator will light solid green when it s working on 100Mbps speed not lit when working on 10Mbps speed FSW 1650 FSW 2450 Ra UU OR arelerireleln mes ACTO Appendix A Specifications Standards IEEE802 3 10Base T IEEE802 3u 100Base TX Protocol CSMA CD Ethernet 10Mbps Half Duplex 20Mbps FullDuplex Data Transfer Rate Fast Ethernet 100Mbps Half Duplex 200Mbps Full Duplex Number of Ports 16 24 10 100Mbps Auto Negotiation RJ 45 ports Safety amp Emissions FCC CE Environmental and Physical Operating Temperature 0 C
3. Chapter 2 Installation isesrisiscceecciscaatscucicinsteccaaiecasecsieta ca inecttecincnccabinnst 2 1 Mounting the Switch on a DeSK cccccecccccceeeeseeeeeeeeeeeseeeeeeeeeees 2 2 Mounting the Switch in a Rack cccccceececccceeeessseseeeeeeeeeeaeeeeeeees 2 3 OWE MOM inst arsta atte tacts a A R Chapter 3 Identifying External Componentts cccssseesseseeeeees 3 1 FORE IVG wcatcavee trees excsancev cosh EE E E 3 2 Rear Paneb srn E A adeeetnnaate aaenesaimemmsaraaces Appendix A Specifications cccccssscsseseecseseeseenseeseeneeseeseeseenees Appendix B Troubleshooting c csccccceseeccesseseeeseeeenseeeeseeneenees FSW 1650 FSW 2450 Ra UU OR arelerireleln mes ACTO Chapter 1 Introduction of the Product This chapter describes the features of the model of FSW 1650 FSW 2450 16 24 port 10 100 Rackmount Switch FSW 1650 and FSW 2450 just differ in the number of LED indicators and ports all figures in this guide are of FSW 2450 1 1 Overview of the product FSW 1650 FSW 2450 6 24 port 10 100 Rackmount Switch provides 16 24 10 100Mbps Auto Negotiation RJ45 ports Each port of the FSW 1650 FSW 2450 supports auto MDI MDI X function eliminating the need for crossover cables or Uplink ports The Switch is Plug and Play and any port can be simply plugged into a server a hub or a switch using straight cable or crossover cable The LevelOne FSW 1650 FSW 2450 16 24 port 10 100 Rackmount switch provid
4. O and 1 The untagged packets and the eight IEEE 802 1p priority levels defined by the standard are mapped to the two class queues used on the switch Class 1 has the higher priority of the two priority queues on the switch The untagged packets and eight priority tags specified in IEEE 802 1p are mapped to the switch s priority as follows E The untagged packets and priority 0 1 2 and 3 are assigned to the switch s class 0 queue E Priority 4 5 6 and 7 are assigned to the switch s Class 1 queue The Switch uses WRR Weighted Robin Round for scheduling WRR queue scheduling algorithm schedules all the queues in turn and every queue can be assured of a certain service time The default weight value of Class 0 queue and Class 1 queue is 1 to 8 FSW 1650 FSW 2450 Ri UMUC are OAC o Chapter 2 Installation 2 1 Mounting the Switch on a Desk Before placing the Switch on a desk attach four rubber feet to the flutes on the Switch bottom then lay the Switch on the desktop where it is able to withstand 5kg of weight CS Note Make sure there is a grounded AC outlet within 1 5 meters and working well Make sure there is free space for radiating heat and air Make sure not to place anything to heavy on top of the switch 2 2 Mounting the Switch in a Rack The dimension of FSW 1650 FSW 2450 is designed according to the standard 19 rack mountable steel case of Electronic Industries Association Powers off all the equipm
5. ent connected to the Switch before mounting it in the rack then rivet the two L brackets onto each side of the Switch and fasten it with screws in the rack Figure 2 1 Rivet the L brackets onto the Switch FSW 1650 FSW 2450 Re UMC arelecrireleln mel i Ca mecy gt mom elel e Atna ae a j d eF San Lod e la I ie Figure 2 2 Fasten the Switch in the rack 2 0 Power on The FSW 1650 FSW 2450 16 24 port 10 100 Rackmount switch is powered by an AC Power Supply Connect the Switch and power outlet by power cord Powering on the Switch it will be automatically initialized and the LED indicators should respond as follows 1 All of the LED indicators will flash momentarily for one second which represent a resetting of the system 2 The Power LED indicator will light up Chapter 3 Identifying External Components This Chapter describes the front panel rear panel and LED indicators of the Switch 3 1 Front Panel The front panel of FSW 2450 consists of switch model switch LED indicators and 24 10 100Mbps RJ 45 ports FSW 1650 FSW 2450 Ri 0a arelerireleln mei ACTO Figure 3 1 FSW 2450 Switch Front Panel sketch 3 2 Rear Panel The rear panel of FSW 2450 only features an electrical outlet which is an AC electrical outlet Connect the female of the power cord head here and the male head to the AC power 18 hw C Figure 3 2 FSW 2450 Switch Rear Panel sketch LED
6. es you with a low cost easy to use high performance seamless and standard upgrade to improve your old network to a 100Mbps network It will boost your network performance up to full duplex data transfer 1 2 Features gt Complies with IEEE802 3 IEEE802 3u standards gt Support IEEE 802 1p QoS gt 16 24 10 100M Auto NegotiationRJ45portssupporting Auto MDI MDIX gt Supports IEEE802 3X flow control for full duplex mode and backpressure for half duplex mode LED indicators for monitoring power link activity soeed FSW 2450 Standard 19 rack mountable steel case Internal power supply EFE oo FSW 1650 FSW 2450 Ra UMUC arelecrireleln mei ACTO 1 3 IEEE 802 1p QoS The FSW 1650 2450 16 24 Port 10 100M switch supports 802 1p priority queuing Quality of Service which is an implementation of the IEEE 802 1p standard With 802 1p QoS function you can reserve bandwidth for important functions that require a large bandwidth or have a high priority such as VoIP voice over Internet Protocol web browsing applications or video conferencing The switch has separate hardware queues on every physical port which packets from various applications are mapped to and assigned a priority to The illustration below shows how 802 1p priority queuing is implemented on the switch Two Priority Queues Queues Class 0 Class 1 i Priority o K Mapping QoS on the Switch The switch has two priority queues labeled
7. o VU a o ORENS FSW 1650 FSW 2450 User Manual 16 24 10 100 Rackmount Switch V3 0 0906 COPYRIGHT amp TRADEMARKS Specifications are subject to change without notice LevelOne is a registered trademark of Digital Data Communications Asia Co Ltd Other brands and product names are trademarks or registered trademarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from Digital Data Communications Asia Co Ltd All rights reserved FCC STATEMENT FE The Switch has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures gt Reo
8. rient or relocate the receiving antenna gt Increase the separation between the equipment and receiver gt Connect the equipment into an outlet on a circuit different from that to which the receiver is connected gt Consult the dealer or an experienced radio TV technician for help EC DECLARATION OF CONFORMITY EUROPE In compliance with the EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC this product meets the requirements of the following standards gt EN55022 gt E N55024 gt EN60950 SAFETY NOTICES ON Caution Do not use this product near water for example in a wet basement or near a swimming pool Avoid using this product during an electrical storm There may be a remote risk of electric shock from lightning Package Contents The following contents should be found in your box gt One FSW 1650 FSW 2450 Switch gt One power cord gt This User s Guide gt Mounting screws and two L planks CS Note Make sure that the package contains the above items If any of the listed items are damaged or missing please contact with your distributor CONTENTS Chapter 1 Introduction of the Product cccseeseeeeeeeeeseeeeees 1 1 Overview Of the product cccccsseeeeeeceeseeeeceeececeeeeeeeeeseueneeeesaas 1 2 FO OQLUNOS oarre dates erase loners rumd haga che on vent elgena eceruutiatamieds 1 3 EEE 021 OS esi sbs cei echt reine psedeegeteovectnctanerie eecas
Download Pdf Manuals
Related Search
Related Contents
Hans Grohe 38118XX1 User's Manual User Manual Advanced Group Tool ESCET Version β0.3 User Manual Copyright © All rights reserved.
Failed to retrieve file