Home
DI-710 Series - Althen GmbH Meß
Contents
1. I EXC 4 Er Strain Q IsochopperTM 20 Gage 4 Amplifier gt Vout tin o go Surge Pat Pending E Suppression N 3 and 19 Qo 5 Protection i 1 Y VO Common l nj z2 Isolated A 3 I Excitation 22 OT i Isolated LES RD EN EXC 1 Source 1 A 1 Computer Side Power a 1 Backpanel Term Block L ne lt ne TV Isolated P v Field Side en Oscillator Power Accessories 62 DI 710 Series and DI 715B Series Hardware Manual Ordering Information MODEL INPUT INPUT RANGE EXCITATION OUTPUT RANGE BRIDGE TYPE DI 5B38 31 or DI 5B38 01 Full Bridge 1000 to 10kQ_ 3 333V at 3mV V Sensitivity 5V to 5V DI 5B38 32 or DI 5B38 02 Full Bridge 300Qto 10kQ 10 0V at 3mV V Sensitivity 5Vto 5V DI 5B38 33 or DI 5B38 03 Half Bridge 1000 to 10kQ_ 3 333V at 3mV V Sensitivity 5V to 5V DI 5B38 34 or DI 5B38 04 Half Bridge 3009 to 10kQ 10 0V at 3mV V Sensitivity SV to 5V DI 5B38 35 or DI 5B38 05 Full Bridge 3009 to 10kQ 10 0V at 2mV V Sensitivity SV to 5V DI 5B38 36 or DI 5B38 06 Full Bridge 1000 to 10kN 3 333V at 10mV V Sensitivity SV to 5V DI 5B38 37 or DI 5B38 07 Full Bridge 3009 to 10kQ 10 0V at 10mV V Sensitivity 5V to 5V Accessories 63 DI 710 Series and DI 715B Series Hardware Manual DI 5B40 41 Analog Voltage Input Modules Wide Bandwidth Each DI 5B40 and DI 5B41 wide bandwidth
2. Accessories 71 Bi DATAQ INSTRUMENTS DATAQ Instruments Inc 241 Springside Drive Akron Ohio 44333 Telephone 330 668 1444 Fax 330 666 5434 E mail supportOdataq com ALTHEN MESS UND SENSORTECHNIK
3. ses 16 Activation of WinDaq High Speed Option oo sesse esse ese ee se Ge Se ee Ge RA Ge Ge nennen 18 Dataq Instruments Hardware Manager esse esse ese ee se de eke ee ee ee Ge ee Ge ee ee Ge RA ee ee ee ed 18 4 Instrument Controls Indicators and Connections eessseeseoeessecessoceessocessocecscoceessccesseccesoceessceeesseceee 21 Connecting the DI 710 to Ground enrete GR AA RA iiia ee AR Re E ee ee ee GR Re ee 21 Instrument Front Panel tran tsk nn A iaa Ue e Pe dee de 22 IDI AAKO O O 22 37 pin D SUD CONMECION eo ene te eee Risiken anne 23 DI H5B Models 45e eet AS 24 Instrument Rear Panel tecnico eere e erbe etie tee tee ee rte S 25 DETIO umodels ee DE et e AR Pee 25 DE715B Models 22 RE ond i ene RE OR ete eet i HET 26 Connecting Signals nun EA EE A UH EE OE il 27 Controls sand Indicators tete ll a repe EN en tee ette late 27 Table of Contents vil DI 710 Series and DI 715B Series Hardware Manual Expansion DI 715B Models u EER ee rr Re ee a e iei EIN Ts bee sege 27 Power Input Jack ui e N e ERE e eX OE vp ge co 27 Power Switch DI 715B Models se ee Ee ee ee Re ee AR ee ee ee ee ee ee ee ee ee 27 Ground ER RR RE Re TN OE EE N edes 27 Intertace Port RARR as GR Ee GE e e Ore pa ie tee ee ede ET as ee 28 Control Button Stand alone Models ccccccsssssseeessneecesecececssaececeeeececeesaeecnesaeseneaeeeensaeeeensas 28 Start Recording e dee ateetan see
4. Channels 1 8 and corresponding Excitation connections can be made directly to the removable screw terminal block located on the rear panel of the instrument All connections are clearly labelled for easy reference Connect each sig nal lead to the appropriate screw terminal signal leads channel 1 channel 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 excitation channel 1 excitation channel 1 signal leads Instrument Controls Indicators and Connections 26 DI 710 Series and DI 715B Series Hardware Manual Connecting Signals Use the removable screw terminal blocks to connect your signals 1 Insert the stripped end of a signal lead into the desired terminal directly under the screw 2 Tighten the pressure flap by rotating the screw clockwise with a small screwdriver Make sure that the pressure flap tightens only against the signal wire and not the wire insulation Do not over tighten 3 Tug gently on the signal lead to ensure that it is firmly secured Loosen Tighten Screwdriver Screw Terminal Block m Signal Lead Pressure Flap When an input signal is connected and WINDAQ Acquisition software is run WINDAQ s real time display immedi ately reveals the input waveform on your computer s monitor Controls and Indicators Expansion DI 715B Models The Expansion connector may be used to access channels 9 16 by connecting either a DI 705 adds up to 8 direct
5. Signal Lead Shield Floating Signal Source Differential Amplifier Locate bias resistors as close to amplifier as possible Signal Cable and the Differential Amplifier Quick rule of thumb Any application requiring a differential amplifier also defines a need for quality signal cable Four elements combine to ensure adequate quality signal cable a twisted signal pair with low resistance stranded copper conductors surrounded by a multiple folded foil shield with a copper stranded drain wire all contained within an insulated outer jacket Insulated Outer Jacket Foil Shield Drain Wire Twisted Signal Pair Stranded Copper Conductors In applications where such signal cable is used a dramatic decrease in noise pickup will be experienced The drain wire should be considered as the shield and should be connected as described in Connecting a Differential Ampli fier on page 46 Signal cable meeting all four criteria for quality is Belden No 8641 Accessories 48 DI 710 Series and DI 715B Series Hardware Manual DI 75B Backpack for use with DI 715B models The DI 75B is an eight channel 5B module expansion device for DI 715B DI 720 and DI 730 instruments Each DI 75B accepts up to eight high performance plug in signal conditioning modules expanding the measurement capa bility of its host instrument Each DI 75B is provided with the appropriate cable to connect it to its host instrument Power is obtaine
6. 6 Click on the MAC address of your device in the list of displayed MAC addresses the MAC address of your device can be found on the silver sticker located on the bottom of your device 7 Enter the IP address your system administrator assigned to you in the New IP Address text boxes 8 Click on the Set Static button Your device will appear in the list of devices to install allowing you to continue your WINDAQ installation at Step 14 It may take more than 15 seconds for your device to appear in the list If you get a No Devices Found error after following the above instructions click the Retry button until the device appears in the list Note These instructions change the settings inside the device If you move the device to a DHCP enabled network i e where IP addresses are assigned automatically by a DHCP server or router you will need to change the device settings using the Dataq Instruments Hardware Manager See the Dataq Instruments Hardware Manager help file for complete details Installation 15 DI 710 Series and DI 715B Series Hardware Manual Installing an Ethernet Device via a Distributed Network with a DHCP Server Installation of an Ethernet device connected to a distributed network that has a DHCP server i e a DHCP router automatically assigns IP addresses to each device connected to the network requires no extra setup i e it is a plug and play device Your PC World Wide Web DI 71X E
7. Local Area Network LAN DHCP Router DI 71X E Note If you are unsure whether your network is DHCP enabled or not check with your system administrator before installing WINDAQ 1 Connect your Ethernet device to your Local Area Network 2 Apply power to the device 3 Install WINDAQ software see Installing WinDaq Software and the Dataq Instruments Hardware Manager on page 16 Installing WINDAQ Software and the Datag Instruments Hardware Manager The WINDAQ Resource CD ROM contains all the software required for use with all DI 710 and DI 715B instru ments If you have a USB device be sure to install the drivers before installing WINDAQ software See Installing the Device Drivers USB Only on page 9 Ethernet devices do not require driver installation Whether you are using the device in the field or while connected to your PC you will need to run at least one of the software components on the CD ROM This installation includes the following software WINDAQ Acquisition software WINDAQ High Speed option Trial version WINDAQ Waveform Browser playback software WINDAQ Waveform Browser for MMC Stand alone models only and the Dataq Instruments Hardware Manager Note For continued use of WINDAQ High Speed option the software must be activated see Activation of WinDaq High Speed Option below for details 1 Connect all instruments you wish to install to your Network or PC and apply power if required
8. Suppression VA O Vin 3 and 19 O Protection V EV VO Common In 5 i N Exc O 22 Isolated ES RDEN i Computer Side i Power 1 1 Backpanel l Term Block i 583 A HERREN TA MAAR __ AAW e NC l AA I I g NC i I Isolated P VC Field Side er Oscillator Power I I Power Common Ordering Information MODEL INPUTRANGE OUTPUTRANGE DI 5B40 01 10mV to 10mV OV to 5V DI 5B40 02 50mV to 50mV OV to 5V DI 5B40 03 100mV to 100mV OV to 5V DI 5B41 01 IV to 1V OV to 5V DI 5B41 02 5V to 45V OV to 5V DISB41 00 X 1OVtodO0V 0OVto 5W DI 5B41 07 20V to 20V OV to 5V DI 5B41 09 40V to 40V OV to 5V Required for DI 500 HV high voltage option CSA certification pending Accessories 64 DI 710 Series and DI 715B Series Hardware Manual DI 5B42 2 Wire Transmitter Interface Modules Each DI 5B42 2 wire transmitter interface module provides a single channel which accepts a 4 to 20 mA process cur rent input and provides a standard 1 to 5V output signal see block diagram An isolated 20VDC regulated power supply is provided to power the current transmitter This allows a 2 wire loop powered transmitter to be directly connected to the DI 5B42 without requiring an external power supply The regulated supply will provide a nominal 20VDC at a loop current of 4mA to 20mA The DI 5B42 will provide a 1500V isolation barrier
9. gt Bi DATAG INSTRUMENTS DHOO SOO OOOO OO OOOOOOOOOOOOOOOO 9 EXCITATION 4 us Tas a ne B c t S EXPANSION OUT 9 to 36 V kommen 0000000000000000000 o CE 00000000000000000000 A 0000000000000000000 o P O 0000000000000000000 0 EXPANSION IN Power AA ai POWER cr eem J Connect the appropriate end of the expansion cable to the host instrument then connect the other end of Din 1 the cable to EXPANSION IN Expansion IN and Expansion OUT connector pin out MEER E E Input Samen 5V Power 1 2 Reserved eh a En i 2 Reserved 3 4 Reserved CH 1 CH 1 30 CH 9 EX 1 29 Reserved 5 6 Reserved CH2 CH2 28 Reserved 7 8 Reserved CH 10 EX 2 27 Reserved 9 10 Reserved VER E SE R Start Stop 11 12 R Event Marks CH 3 CH 3 24 CH 11 EX 3 23 PWR GND 13 14 Reserved CH 3 CH3 22 CH 11 EX3 21 Reserved 15 16 Reserved CH4 CHA 20 DAC 1 17 18 Analog GND CH 12 EX4 19 Reserved 19 20 Reserved eu d EN he CH 16 21 22 CH8 CHS CH5 16 CH 13 EX5 15 CH 15 23 24 CH7 CH5 CH 5 14 CH 14 25 26 CH6 raum eus 12 CH 13 27 28 CH5 un enr i CH 12 29 30 CH4 CH 14 EX 6 9 CH7 CH7 8 CH 11 31 32 CH3 CH 15 EX 74 7 CH 10 33 34 CH2 CH 7 CH 7 6 CH9 35 36 CH 1 ch B ER 1 AGND 37 38 Reserved CH 16 EX 8 3 CH 8 CH 8 2 Reserved 39 40 Reserved CH 16 EX8 1 Accessories 51 DI 710 Series and DI 715B Series Hardware Manual Removable Screw Terminal Block
10. All USB devices must have their drivers installed prior to continuing installation 2 Re insert the WINDAQ Resource CD for the auto play feature to run or run the Setup application 3 In the What do you want to do window select Install Software and click OK Installation 16 DI 710 Series and DI 715B Series Hardware Manual 10 12 In the Installing Software window select Install Software for DI 148 DI 158 DI 710 and DI 715B instru ments and click OK Select the Install Software option and click OK to continue If you wish to view the hardware documentation you may do so now In the Welcome box click OK to continue Read the License Agreement If you accept the terms click Accept and Continue If you choose not to accept this will end the installation When prompted enter your registration information name and company in the appropriate text boxes and click OK Confirm your registration information before continuing When prompted specify the directory where you want to install your WINDAQ software It is recommended that you accept the default If you have already successfully installed a DI 148 DI 158 DI 710 or DI 715B instru ment be sure to install to the same folder Make sure each instrument is connected to your PC or Network and all device drivers are installed You must install two device drivers for each USB instrument Click OK to continue The DATAQ Installa
11. Allows signal connections to be made to the DI 75B The input signal connections are made along the top row while the excitation connections for those DI 5B modules that require excitation are made along the bottom row Note that this screw terminal block can be removed from the DI 75B thus making signal connections to the screw terminals easy Note also that the screw terminal block is keyed thus difficult to improperly re insert Each channel labeled CHANNEL 1 CHANNEL 2 etc on the socketed backplane has four corresponding screw terminals for your signal connections channel channel excitation and excitation These terminals satisfy all transducer inputs and provide sensor excitation when necessary POWER switch Controls power to the DI 75B 1 is on 0 is off POWER input jacks The DI 75B 7 can be powered by its host instrument through the supplied dual ended power cable Simply unplug the five pin DIN end of the power adapter cable that is currently supplying power to your host instrument and plug it into one of the DI 75B s power input jacks Now plug one end of the dual ended power cable into the remaining power jack on the DI 75B and plug the other end into the host instrument power input jack POWER status lamp Glows green when the POWER switch is in the 1 position indicating power is applied to the DI 75B POWER LOW lamp Glows red when the DI 75B cannot derive adequate power from its host instrument I
12. Expansion Connector 10K Microcontroller H Control 0 Y i SD VO Code Ground gt USB or Ethernet Interface Power 9 36 VDC Power Supply Stand Alone Models Only Block Diagram 40 DI 710 Series and DI 715B Series Hardware Manual 7 Accessories ZI BIERE E ERE ES 42 The DI 205 for use with DI 710 D models uceiras insiren nii innn i 44 DI 75B Backpack for use with DI 715B models sess 49 DIPS B Anl 54 DI 5B30 31 Analog Voltage Input Modules Narrow Bandwidth se se ee ee 54 DI 5B32 Analog Current Input Modules see se se ee Ge Ge ee Ge GR GRA ee ee ee Ge 55 DI 5B33 Isolated True RMS Input Modules esee 56 DI 5B34 Linearized 2 or 3 Wire RTD Input Modules eere 57 DI 5B35 Linearized 4 Wire RTD Input Modules see ee ee ee ee GR GRA ee ee Ge 59 DI 5B36 Potentiometer Input Modules se se se ee Ge AG Ge ee ee GR GRA ee ee Ge Ge 61 DI 5B38 Strain Gage Input Modules Narrow amp Wide Bandwidth 0 0 esse esse esse se sess 62 DI 5B40 41 Analog Voltage Input Modules Wide Bandwidth ee ee 64 DI 5B42 2 Wire Transmitter Interface Modules eee ses se eese 65 DI 5B43 Isolated DC Transducer Amplifier Input Module eee 66 DE5B45 Frequency Input Modules eisini sesse Pas terr petet nennen 68 DI 5B47 Linearized Thermocouple I
13. F to 160 C 320 F 100 at 0 C OV to 5V 0 32 C 1200 Ni a 0 00672 DI 5B34N 01 0 C 32 F to 300 C 572 F OV to 5V 0 40 C Includes conformity hysteresis and repeatability CSA certification pending Accessories 58 DI 710 Series and DI 715B Series Hardware Manual DI 5B35 Linearized 4 Wire RTD Input Modules In RTD temperature measurement applications requiring a very high level of accuracy the DI 5B35 4 Wire RTD input module offers a significant advantage over 3 wire measurement techniques see block diagram The DI 5B35 measures only the voltage dropped across the RTD and almost completely ignores the resistance or length of the RTD lead wires The DI 5B34 3 Wire RTD module provides lead resistance compensation but requires equal lead resis tances while the DI 5B35 does not require matched lead resistances Each DI 5B35 RTD input module provides a single channel of RTD input which is filtered isolated amplified lin earized and converted to a high level analog voltage output This voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output
14. channel The digital bits on a DI 715B are only accessible through a DI 705 see The DI 705 on page 42 Introduction 2 DI 710 Series and DI 715B Series Hardware Manual Software All software required to record and playback waveforms is included with the purchase of any DI 710 or DI 715B model including WINDAQ Acquisition and Playback software and the Datag Instruments Hardware Manager WINDAG Recording and Playback Software WINDAQ Acquisition and WINDAQ Waveform Browser allow you to record and playback data acquired through your instrument Whether using a Stand alone model or a PC connected instrument WINDAQ is an invaluable resource to analyzing your data A special version see WinDaq Waveform Browser for MMC on page 37 of WINDAQ Wave form Browser free is required to read waveform data recorded to a Memory Card but is easily transferred to the standard version for more analytical features WINDAQ Acquisition software can be used to record waveforms directly and continuously to disk while monitoring a real time display of the waveforms on screen It operates and displays waveform signals in real time at the full sample rate of the instrument being used There are two versions of WINDAQ Acquisition software available for use with DI 710 and DI 715B Instruments WINDAQ Lite and WINDAQ High Speed option WINDAQ Lite is free but is restricted to recording throughput rates of 1108 Hz with a DI 710 or DI 715B WINDAQ High Speed op
15. which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 Excitation for the potentiometer is provided from the module by two matched current sources When using a three wire potentiometer this method allows cancellation of the effects of lead resistances The excitation currents are very small less than 1 0mA which minimizes self heating of the potentiometer Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the other four are in the output stage After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is pro vided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 45 A special input circuit on the DI 5B36 module provides protection against accidental connection of power line volt ages u
16. 29 for more information Instrument Controls Indicators and Connections 28 DI 710 Series and DI 715B Series Hardware Manual Mode LED Indicator Indicates what mode the instrument is currently in Use the chart on the rear panel of the instrument for quick refer ence Use the table provided below for a more detailed description of each available state State Mode Description Stand alone data logger operation Static Green Standby Instrument is powered and available for data acquisition operations Memory card may be safely removed Flashing Green Busy Indicates the instrument is busy Do Not Remove Memory Card Orange Error Possible errors include but are not limited to MMC SD removed prematurely Memory card removed before the instrument had a chance to close the data file Reinsert the card and Press the Control button to close the file When steady green memory card is closed and can be removed safely MMC SD Lock After initially pressing the Control button to begin recording data two series of blinking Orange before reverting back to Green indicates that the mem ory card is locked Use another card or unlock the current one One series of blinking Orange before reverting back to Green indicates that the memory card is incompatible for use with the instrument Use the recommended memory card available through DATAQ Instruments Inc See also Troubleshooting on page 35 Slow Flashing Rec
17. 7 through the EXPANSION OUT port Channel Selection Channels a 34 5 6 MESES deed P ENGEN in MUX A Thesearethe These are the signal the digital channel and is only signal conditioned conditioned input ible through a DI 70 input channels on channels on the DI 758 ith CABL 7 connected to the DI 715B when connected to EXPANSION OUT of the the DI 71 5B il DI 75B Click to select check or deselect Double click to select differential Click right to select digital input I MUX letters occupy the expansion inputs OK Cancel See the Dataq Instruments Hardware Manager Help files to configure channels for DI 75Bs connected to stand alone models Calibration Each 5B module has an Input and Output equivalent printed on it for calibration purposes Each channel should be calibrated for its specific 5B module Calibration for the DI 75B modules is completed exactly the same as for DI 715B modules See Calibration and Gain Settings on page 32 for more information Gain The signal conditioned or DI 5B module channels on the DI 75B output 5 volts to the host instrument Since the DI 715B is a 10 volt input device each DI 75B signal conditioned channel in use should be set to at least a gain of 2 so they have a full scale measurement range of at least 5 volts Use the same method described at Gain on page 33 to set the gain of the DI 75B signal conditioned inputs Installing Shunt
18. 715B Series Hardware Manual The DI 205 for use with DI 710 D models The DI 205 is a termination panel for general purpose input and output The DI 205 along with the supplied cable provides a convenient way to interface the Digital I O analog output and analog input signals to DI 710 Series D models see 37 pin D sub connector on page 23 Signal connection is via terminal strip for digital and analog out put signals or 5 way binding posts banana jacks for analog input signals Input Output Panel Interconnections Digital VO Analog Output Model DI 205 Digital VO Analog Output The 20 position screw terminal block labelled Digital I O Analog Output provides access to the Digital I O ports of the 37 pin D sub connector Note Digital I O connections cannot be used concurrently DIO and DOO are directly connected inside the DI 710 as are DII and DOI DI and DO2 etc The Digital VO is not available in stand alone mode See 37 pin D sub connector on page 23 for pinout DACI and DAC2 are Reserved ports and should not be used VOUT connects to the 5VPWR pin See 37 pin D sub connector on page 23 for pinout Accessories 44 DI 710 Series and DI 715B Series Hardware Manual Input Signal Configuration Each DI 205 may be configured to connect to 16 single ended or 8 differential channels In addition any combination of single ended or differential channels may be applied A differential c
19. DI 710 UL N Y N Y N N DI 710 ULS N Y N Y Y N DI 710 EH Y N Y N N N DI 710 EHS Y N Y N Y N DI 710 EL Y N N Y N N DI 710 ELS Y N N Y Y N DI 715B E Y N Y N N Y DI 715B ES Y N Y N Y Y AII DI 710 models available with a 37 pin D sub connector as opposed to two removable 16 port screw termi nal blocks Add D to the model number See 37 pin D sub connector on page 23 Features The DI 710 has the following features Multiple Hardware options USB or Ethernet Interface PGL or PGH gain settings and Stand alone data logger Operation capabilities All options available in any configuration Per channel software configurable settings Single ended or differential input input gain and calibration 4 800 samples second maximum sampling rate up to 14 400 samples second when recording to a memory card 0 048 samples second minimum sampling rate 0 0017 samples second when recording to a memory card 14 bit A D converter for high resolution measurement accuracy 16 entry input scan list allows you to scan any sequence of input channels at any available gain The Stand alone option allows the user to configure a recording session through their PC then record data in the field to a memory card SD or MMC without being connected to their PC The DI 715B has the following features Accepts up to 8 DI 5B Modules accommodating virtually any industrial signal Per channel software configurable settings input
20. EV 5 RD EN A A Isolated l Computer Side Power V I Backpanel i Term Block 1 NC 2 NC N Isolated p 9VDC V Field Side ower P Oscillator ower Power Common Accessories 59 DI 710 Series and DI 715B Series Hardware Manual Ordering Information MODEL INPUT RANGE OUTPUT RANGE ACCURACY 100Q Pt o 0 00385 DI 5B35 01 100 C 148 F to 100 C 212 F OV to 5V 0 46 C DI 5B35 02 0 C 32 F to 100 C 212 F OV to 5V 0 36 C DI 5B35 03 0 C 32 F to 200 C 392 F OV to 5V 0 46 C DI 5B35 04 0 C 32 F to 600 C 1112 F OV to 5V 0 88 C 10Q Cu a 0 004274 DI 5B35C 01 0 C 32 F to 120 C 248 F 100 at 0 C OV to 5V 0 23 C DI 5B35C 02DI 0 C 32 F to 120 C 248 F 10Q at 25 C OV to 5V 0 23 C 5B35C 03 0 C 32 F to 160 C 320 F 10Q at 0 C OV to 5V 0 32 C 1200 Ni a 0 00672 DI 5B35N 01 0 C 32 F to 300 C 572 F OV to 5V 0 40 C Includes conformity hysteresis and repeatability CSA certification pending Accessories 60 DI 710 Series and DI 715B Series Hardware Manual DI 5B36 Potentiometer Input Modules Each DI 5B36 Potentiometer input module provides a single channel of Potentiometer input which is filtered iso lated amplified and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled
21. Help menu item or by pressing the Fl key to access context sensitive help Installation 19 DI 710 Series and DI 715B Series Hardware Manual 4 nstrument Controls Indicators and Connections Connecting the DI 710 to Ground IMPORTANT The ground connection on the I O terminal strip should always be connected to a signal ground if one is not inher ently made through analog or digital signal connections Without this connection the front end of the DI 710 does not have a return path which could lead to inaccurate measurements Under no circumstances should the DI 710 be used in a measurement situation where it will experience common mode voltages in excess of 430 VDC or peak AC the device s full scale range without damage The ground lug at the rear of the DI 710 should always be connected to a solid chassis or earth ground This connec tion is mandatory for the unit to meet CE guidelines Analog Inputs gt Digital VO To signal ground Solid Chassis or if not inherently Earth Ground made through Connection analog or digital connections Interface USB Ethernet Front End Rear Panel Ground Lug ZO 3 gt Fr00 Analog Ground Connection Two Critical DI 710 Ground Connections Instrument Controls Indicators and Connections 21 DI 710 Series and DI 715B Series Hardware Manual Instrument Front Panel DI 710 Models The 32 port screw terminal access connector is used to interface analog inp
22. LED turns off and release If LED is orange press it again When LED turns green reformat your memory card When memory card is inserted into a reader a not formatted error is seen Dependent upon the reader being used Sometimes the driver for an SD card reader appears dead Reboot your PC When attempting to read the mem ory card using a card reader the PC takes an interminably long time to open the data Dependent upon the memory card card reader and the PC you are using The amount of time it takes to open the card will vary Using the Lock feature on an SD could speed up the process Be sure to try that before purchasing new equipment After viewing data files through a card reader upon initiating a recording session the LED blinks orange then turns green The instrument has a unique file sys tem When the data on the memory card opens in Windows sometimes Windows will modify the file system You must reformat the card To prevent further instances of this error use the Lock provided on your SD card If you have an MMC you will have to reformat the card with each subsequent use When attempting to read the mem ory card using a card reader the data file is huge completely fills up the memory card and the actual waveform data is difficult to find The instrument did not have a chance to properly close the file If you have not started using the instrument
23. Software License Agreement can be found in the WINDAO Software manual or in the WINDAQ program group License txt The WINDAQ HS may be activated through the Help menu by clicking on Unlock WINDAQ HS or by waiting for the trial version to expire Trial versions are good for 40 High Speed over 1108 Hz throughput recording sessions The High Speed version may be purchased after the trial period expires through our online store or by phone For help or for questions regarding Activation and or the Software License Agreement contact DATAQ Instruments Customer Support Dataq Instruments Hardware Manager The Dataq Instruments Hardware Manager is installed when installing any DI 710 or DI 715B instrument This soft ware allows you to effectively manage and run multiple instruments installed and connected to your PC or your Net Installation 18 DI 710 Series and DI 715B Series Hardware Manual work or even over the internet WINDAQ Data Acquisition Software and the Stand alone Set Up program are both accessed through the Dataq Instruments Hardware Manager The Dataq Instruments Hardware Manager may be accessed through the Windows Program Manager Group as specified during installation default is Start gt Programs gt WINDAQ gt Dataq Instruments Hardware Manager All available devices will automatically appear in the list box when you run the software For help with the Dataq Instruments Hardware Manager access the Help Files using either the
24. a single channel of RTD input which is filtered isolated amplified lin earized and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplex ers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 RTD excitation is provided from the module by two matched current sources When using a three wire RTD this method allows an equal current to flow in each RTD lead which cancels the effects of lead resistances The excitation currents are very small 0 25mA for 1000 Pt and 1200 Ni and 1 0mA for 100 Cu which minimizes self heating of the RTD Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the other four are on the com puter side After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a
25. eiie kst hust eet a nern etd det oda 28 Sie ese AR te aee e Ha ME EE ate 28 Formatting the Memory Card oo ees esse se see ee Ge RA GR ee Ge Ge a E ee Ge RA ee ee 28 Rec nfisure Instrument Eie Ee disidencia Pit eye Sk E p eb 28 Ste ke C 28 ER ESE PET es oo 4 2 EE EE ea ia EE 29 Removable Storage Slot MMC Stand alone Models sese 29 Installing a Shunt Resistor in DI 715B Models iese ese ese Re ee Ge RA ee ee rennen 29 Sl 0 1073 ELE EA 31 PCzconnected AG RR RE ER KEER ER ENE EE N 31 Enabling Disabling the Digital VO and Remote Control sesse eee 31 Channel Configuration for the DI 715B se se ee Ge Ge Re Se ee RA nennen nens 31 Enabling Channels iS Er et redo ites SR Re ERE Eee Rr P red Doe cotone cid 31 Calibration and Gain Settings 1 ies see ee es ke soe Be SE AG Ek Se AE GEE tnt tet tente aeneo de Se Ge de Ge E ee 32 High Low Calibration RE t fete ee RE EE N EE ER N 32 Fixed Calibration sitial n aid 32 GAM RE RE RA 33 Stand alone Models sci fice 2 2 2 sd Ra RE In 33 PC connected operation 2 et eae eee nite te Dec toni Renee 34 Networked operation as a data acquisition server DI 710 ELS DI 710 EHS and DI 715B ES models pr TREE NE 34 Stand alone data logger operation iese ee ese se ee Ge Ge Ge ee ee RA RA Ge ee ee erret enne 34 The Stand alone Set Up Panel cuneta tee E t tie Pic Fest Ue ple Rete gek hastens 34 Operation iR eed uen t
26. for non isolated 2 wire field transmitters It can also be used when additional isolation is required between an isolated 2 wire transmitter and the input stage of the control room computer The voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 A precision 20Q current conversion resistor is supplied with the module All field inputs are fully protected from accidental connection of power line voltages up to 240VAC The module has a 3dB bandwidth of 100Hz Signal fil tering is accomplished with a six pole filter with two poles on the field side of the isolation barrier and the other four on the computer side 2 Wire Transmitter Isolation Barrier I EXC LPF Isochopper 20 4 Amplifier gt Vour tin Q Surge Pat Pending Suppression 3 and 19 O Protection 2 VO Common In 2 V V WY 22 ae Isolated n n 5 RD EN 2 1 Excitation Source Isolat
27. four are on the com puter side After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 5 A special input circuit on the DI 5B32 modules provides protection against accidental connection of power line volt ages up to 240VAC Ordering Information MODEL INPUT RANGE OUTPUT RANGE DI 5B32 01 4mA to 20mA OV to 5V DI 5B32 02 OmA to 20mA OV to 5V Accessories 55 DI 710 Series and DI 715B Series Hardware Manual DI 5B33 Isolated True RMS Input Modules Each DI 5B33 True RMS input module provides a single channel of AC input which is converted to its True RMS dc value filtered isolated amplified and converted to a standard process voltage or current output see block diagram The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 The field voltage or current input signal is processed through a pre amplifier and RMS converter on the field side o
28. magnetic pickup or contact closure type sensors The excitation is avail able on pin 1 EXC and the excitation common is pin 3 In The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 A special circuit in the input stage of the module provides protection against accidental connection of power line voltages up to 240VAC Threshold 68 Zero Crossing Comparator Isolation Barrier inputs EXC o we p Signal TEES 20 y In Surge Isolation OUT Z TTL Suppression 1 NS d i BA Inputs o PN iV E M CAS VO Common nj 2 i i i Va EXC Y Isolated 77 5 RD EN 1 Computer Side sv Power N Backpanel Term Block wc nc Tw Isolated E Field Side dea Power Oscillator Ordering Information MODEL INPUT RANGE OUTPUT RANGE EXCITATION DI 5B45 01 0 to 500Hz 0 to 5V 5 1Vdc E 8mA DI 5B45 02 0 to 1kHz 0 to 5V 5 1Vdc E 8mA DI 5B45 03 0 to 3kHz 0 to 5V 5 1Vdc E 8mA DI 5B45 04 0 to 5kHz 0 to 5V 5 1Vdc 8mA DI 5B45 05 0 to 10kHz Oto 5V 5 1Vdc 8mA DI 5B45 06 0 to 25kHz 0
29. proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5VDC 45 A special input circuit on the DI 5B34 modules provides protection against accidental connection of power line volt ages up to 240VAC 3 and 4 Wire 2 Wire Isolation Barrier 20 Vour Linearizer I I LPF N IsochopperTM Amplifier 19 i x Surge Pat Pending gt VO Common uppression RTD EI and Y 22 Protection N Lag RD EN A I Isolated Computer Side 4 Wire Power VA Backpanel Term Block 1 NC sg 5VDC X Isolated NOTE 1 4 wire sensors may be Field Side Power used with this module However Power Oscillator for true 4 wire measurement use 5B35 Power Common Accessories 57 DI 710 Series and DI 715B Series Hardware Manual Ordering Information MODEL INPUT RANGE OUTPUT RANGE ACCURACY 1000 Pt a 0 00385 DI 5B34 01 100 C 148 F to 100 C 212 F OV to 5V 0 46 C DI 5B34 02 0 C 32 F to 100 C 212 F OV to 5V 0 36 C DI 5B34 03 0 C 32 F to 200 C 392 F OV to 5V 0 46 C DI 5B34 04 0 C 32 F to 600 C 1112 F OV to 5V 0 88 C 10Q Cu a 0 004274 DI 5B34C 01 0 C 32 F to 120 C 248 F 100 at 0 C OV to 5V 0 23 C DI 5B34C 02 0 C 32 F to 120 C 248 F 100 at 25 C OV to 5V 0 23 C DI 5B34C 03 0 C 32
30. slots Input connectors Operating Environment Enclosure Dimensions Weight Power Requirements Three color LED indicating Record Standby and Error conditions Power LED up to 4 800 samples per second up to 2 400 samples per second Mode LED Control push button Stand alone models Accepts MMC SD type flash memory DI 710 Two removable sixteen position terminal blocks DI 715B One removable 32 port screw terminal block 0 C to 70 C DI 710 Aluminum base with steel wrap around Aluminum end panels with plastic bezels DI 715B Aluminum base with steel wrap around Clear acrylic front panel DI 710 5 4 Dx 4 1 W x 1 5 Hin 13 81D x 10 48W x 3 81H cm DI 715B 9 D x 7 29 W x 2 7 H in 22 86D x 18 52W x 6 86H cm DI 710 14 oz 397 grams DI 715B 3 lbs 1 36 kg DI 710 USB products 9 to 36 VDC 2 watts maximum DI 710 Ethernet products 9 to 36 VDC 2 5 watts maximum DI 715B USB products 9 to 36 VDC 2 watts 5B modules DI 715B Ethernet products 9 to 36 VDC 2 5 watts 5B modules Specifications 7 DI 710 Series and DI 715B Series Hardware Manual 3 Installation Unpacking The following items are included with each instrument Verify that you have the following e DI 710 Series or DI 715B Series Instrument Communications cable USB ONLY Ethernet models do not come with an Ethernet cable e Power cable except DI 710 UL and DI 710 UH The WINDAO Resource CD ROM e DATAQ
31. switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 RTD excitation is provided from the module by a precision current source The excitation current is available on two leads which are separate from the two input signal measuring leads The excitation current does not flow in the input signal leads which allows RTD measurement to be totally independent of lead resistance The excitation current is very small 0 25mA for 1000 Pt and 1200 Ni and 1 0mA for 10Q Cu which minimizes self heating of the RTD Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the other four are on the com puter side After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5VDC 5 A special input circuit on the DI 5B35 modules provides protection against accidental connection of power line volt ages up to 240VAC Isolation Barrier IsochopperTM Amplifier 19 Pat Pending gt 1 0 Common Surge I I I I I Suppression and v 22 I Protection V
32. with a different mem ory card reinsert the card and press the LED for about 1 second until LED turns off and release The LED should be green indicat ing the file is closed and can be read If you have already configured and used the instrument again the file can no longer be closed and you will have to search for it and cut paste the data into a new file If power down occurs unexpectedly while recording to MMC SD The Stand alone models have a built in file protection feature If power is lost while recording all data prior to up to 255 samples from the power failure is available If power is lost for any reason the data file will be closed and saved and a new data file will be started when power is restored Mode LED will flash red 1 Hz if that option is selected in the Hardware Manager Stand alone setup Operation 36 DI 710 Series and DI 715B Series Hardware Manual If the memory card is full the Mode LED will quickly flash orange and then green and will not record new data until reformatted Circular memory configuration may still be used if the memory card has not started to wrap the data i e as long as the card is not full and will only wrap data in the available space When recording at low sample rates be aware that the memory card must acquire 256 samples before it actually com mits them to memory For example if you are recording one channel at 1 sample per second and power down occurs unexpecte
33. 47MQ resistor 20 tolerance between screw terminals 1 and 3 Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the other four are on the com puter side After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 5 A special circuit in the input stage of the module provides protection against accidental connection of power line voltages up to 240VAC 2 5V 100MQ Isolation Barrier I Linearizer 20 gt Vour E Power Common 4 EXC Ne Isochopper 4 Amplifier 19 In D 6 Surge Pat Pending S VO Common Thermocouple 3 Suppression 5 and 22 D I lt Protection Loy ET gt RD EN nj z AA d 2 BE T i Isolated 1 Precision Reference Computer Side l Power 1 I Backpanel Term Block CJC N SESSE 1 a 2 I 1 Temp Isolated p 5VDC Sensor Field Side o Oscillator Power I 69 Accessories DI 710 Series and DI 715B Series Hardware Manual Ordering Information MODEL TYPE INPUT RANGE ACCURACY DI 5B47
34. DAQ Software Manual for directions on using the WINDAQ software pack age Note If your USB module experiences frequent lock ups connect the Ground Lug to your PC ground If the prob lem persists please contact Technical Support Enabling Disabling the Digital VO and Remote Control To use the Remote Control features in WINDAQ Acquisition Software Channel 1 or Channel 17 must be enabled as the Digital Input channel In order to use all 16 analog input channels Channel 17 may be enabled for general pur pose digital I O functions The direction of the digital bits must be set in the DATAQ Instruments Hardware Manager using the Digital I O Setup command The default state from the factory is that all digital bits are set as Inputs with a High signal 5V Channel Configuration for the DI 715B Enabling and configuring channels with the DI 715B in WINDAQ Acquisition software is different than enabling channels with other instruments and is not covered in the Help Files Enabling Channels Use the Channel Selection grid to enable and configure channels Access the channel selection grid by selecting Channels in the Edit menu in the SET UP operating mode of WINDAQ software Each box in this grid represents an input channel An input channel is enabled by clicking in its channel box The following channel selection grid is typical for a DI 715B Channels to 8 are the signal conditioned inputs Channels 9 to 16 are direct inputs accessible only us
35. Distributed Network Without a DHCP Server Installation of an Ethernet device connected to a distributed network that does not have a DHCP server or where the DHCP server is turned off requires you to obtain an IP address from your system administrator DI 71X E More Nodes As Needed CAT 5 Cable eoo 100M Max N Your PC PC Note In the illustration above the Hubs could instead be routers with DHCP turned off i e a static IP assigned net work Contact your system administrator for details about your network 1 2 Have the system administrator designate an IP address for your device Plug the device into your network and apply power Install WinDaq software see Installing WinDaq Software and the Dataq Instruments Hardware Manager on page 16 up to Step 13 At Step 13 the installation software will not see your device If it is the first Dataq Instruments device installed to your network you will see the No Devices Found dialog box Pi No Devices Found No DATAG Instruments devices found Retry Help Installation 14 DI 710 Series and DI 715B Series Hardware Manual 5 Click on the Add IP button either in the No Devices Found dialog box or in the main Datag Instruments Instal lation dialog box This will display the Manage IP Addresses dialog box B Manage IP Addresses MAC Address 00 20 44 86 44 B5 169 254 231 211 New IP Address 192 168 o mM Add Remote Cancel
36. J 01 Type J 0 C to 760 C 32 F to 1400 F 0 61 C DI 5B47J 02 Type J 100 C to 300 C 148 F to 572 F 0 32 C DI 5B47J 03 Type J 0 C to 500 C 32 F to 932 F 0 36 C DI 5B47J 12 Type 100 C to 760 C 148 F to 1400 F 0 70 C DI 5B47K 04 Type K 0 C to 1000 C 32 F to 1832 F 0 80 C DI 5B47K 05 Type K 0 C to 500 C 32 F to 932 F 0 38 C DI 5BA7K 13 Type K 100 C to 1350 C 148 F to 2462 F 1 20 C DI 5B47K 14 Type K 0 C to 1200 C 32 F to 2192 F 0 96 C Includes conformity hysteresis and repeatability Does not include CJC accuracy Accessories 70 CSA certification pending DI 710 Series and DI 715B Series Hardware Manual DI 5B48 Accelerometer Input Modules The DI 5B48 provides excitation to piezoelectric sensors with built in microelectronic amplifiers commonly known as ICP or IEPE or LIVM sensors The module provides a constant current excitation to the sensor then isolates filters and amplifies the sensor output yielding a high level analog voltage output The excitation current signal gain and filter high pass and low pass cutoff frequencies are field configurable through a set of slide switches Six poles of signal filtering in the DI 5B48 module result in greater than 100dB of normal mode rejection for signal frequencies above the cutoff frequency One pole of filtering is on the field side of the isolation barrier for anti alias ing purpo
37. NE N EP 34 TroubleshOOLBfg seek Chee ee tte tec iere a Oen ae ee 35 If power down occurs unexpectedly while recording to MMC SD eee 36 WinDaq Waveform Browser for MMC sees nennen nennen enne 37 6 Block Diagram GE OE sts 39 DESTOM ElS assist eee A EE OE eid 39 BE Ys Models st EE EE RE EE HE EE 40 Ts Teu E DEE DEE N DE LE AT OE N DEE N 41 The DEIN ER iden ee pe AE EE OE AE 42 Using the DI 705 with DI 710 D Models see se ee ee Ge Ge AR Re ee ee Ge ee ee 42 Using the DI 705 with DI 715B Instruments eese GR Re Ge Ge ke ee 43 The DI 205 for use with DI 710 D models ees ee essere 44 Input Output Panel Interconnections 200 eee se se ee ee RA GRA Ge ee Ge GRA ee renn 44 Digital VO Analog Output ENS hii RES GE iii 44 Input Signal Configuration axes Eee Hte eet Re arm shes aves RER seta 45 Connecting a Single ended Amplifier iese sees see ee Ge Ge Ge ee GR RA ee Ge Ge ke ee 45 Connecting a Differential Amplifier see ee Ge GR Ge ee ee GR GR ee Ge rennen 46 Ground referenced Signal Sources eerte 46 Isolated Signal Sources i ene Ue EE OE EN 48 Signal Cable and the Differential Amplifier esee 48 DI 75B Backpack for use with DI 715B models eese eere enne 49 Table of Contents viii DI 710 Series and DI 715B Series Hardware Manual C
38. O2 etc Refer to 7 Accessories for accessories that can be used with the 37 pin D sub connector Instrument Controls Indicators and Connections 23 DI 710 Series and DI 715B Series Hardware Manual DI 715B Models The clear acrylic front panel allows easy identification of all installed DI 5B modules To access the 5B backplane remove the front panel and bezel by removing the two outside screws When reattaching the front panel be sure not to overtighten the screws 1 Remove front panel and bezel by removing the two screws 2 DI 5B Modules are installed to the 5B backplane using the set screw DI 715B praeci DO g TANNVHO OOOO 1 TANNVHO 1ANNVHO 0000 S ooo oooo OOOO 0000 o I gt rd z m r o amp DI 5B modules are installed on or removed from the socketed 5B backplane and are secured with a non removable mounting screw Each channel position is labeled CHANNEL 1 CHANNEL 2 etc on the socketed backplane The DI 5B modules can be mixed or matched in any combination suitable for the application and are identical in pinout and size so it doesn t matter which module gets plugged into which channel position Instrument Controls Indicators and Connections 24 DI 710 Series and DI 715B Series Hardware Manual Instrument Rear Panel DI 710 models The Rear panel of your DI 710 Model can vary depending on your model Stand alone models ad
39. Resistors To use the Current Input Modules DI 5B32 and DI 5B42 you must install a shunt resistor provided with purchase of 5B module for accurate readings Instructions for the DI 75B are the same as instructions for the DI 715B See Installing a Shunt Resistor in DI 715B Models on page 29 for instructions on installation of shunt resistors Accessories 53 DI 710 Series and DI 715B Series Hardware Manual DI 5B Modules DI 5B30 31 Analog Voltage Input Modules Narrow Bandwidth Each DI 5B30 and DI 5B31 voltage input module provides a single channel of analog input which is filtered iso lated amplified and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled allowing these modules to share a common analog bus without the requirement of external multi plexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the othe
40. S NOT COVERED BY THE PRODUCT S WARRANTY Please read the following carefully before deploying the product Contact DATAQ Instruments Support at 330 668 1444 for all questions If you have purchased a DI 715B you do not need to follow these instructions This product can tolerate a maximum applied voltage of only 20V peak without damage Although you may be cer tain that the signal you want to measure is lower than this level a common mode voltage CMV with an unknown value may combine with your signal of interest to exceed this 20V limit In such instances the product will be dam aged Verify a CMV does not exist before connecting signals and acquiring data with your device Use the following procedure to check for CMV 1 DO NOT connect your data acquisition device to the device under test If the device under test is connected to your data acquisition device disconnect it 2 Connect your data acquisition device to the appropriate interface on your PC USB Ethernet RS 232 Serial or Parallel Printer Port 3 Apply power to your data acquisition device your PC and the device under test 4 Use a digital voltmeter to make the following measurements a Measure the voltage both the AC and DC range between the ground terminal of your data acquisition device and Signal of the device under test This measurement should not exceed the Full Scale Range of your data acquisition device b Measure the voltage both the AC and DC range be
41. ardware Manual Ordering Information MODEL MAXIMUM INPUT EXCITATION DI 5B43 01 1V 10 0Vde 40mA DI 5B43 02A 2V 10 0Vde 40mA DI 5B43 03 3V 10 0Vde E 40mA DI 5B43 04A 4V 10 0Vde 40mA DI 5B43 05 5V 10 0Vde 40mA DI 5B43 06 6V 10 0Vde 40mA DI 5B43 07A 7V 10 0Vde 40mA DI 5B43 08A 8V 10 0Vde 40mA DI 5B43 09 9V 10 0Vde 40mA DI 5B43 10 10V 10 0Vde 40mA CSA certification pending Accessories 67 DI 710 Series and DI 715B Series Hardware Manual DI 5B45 Frequency Input Modules Each DI 5B45 frequency input module provides a single channel of frequency input which is isolated and converted to a high level analog voltage output This voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers see block diagram The frequency input signal can be a TTL level signal or a zero crossing signal Terminal 3 In on the field side ter minal block is the common or ground connection for input signals A TTL signal is connected from terminal 2 In to terminal 3 In while a zero crossing signal is connected from terminal 4 EXC to terminal 3 In Input cir cuitry for each of the signal types has hysteresis built in An input signal must cross entirely through the hysteresis region in order to trigger the threshold comparator A 5 1V excitation is available for use with
42. circumstance The Control Button is inoperable while running WINDAQ Acquisition software Start Recording To Start recording data to your memory card the Instrument must be in Standby Mode Mode LED is Green Press and hold the Control Button until the Mode LED turns off about 1 second Release the Control Button The Mode LED will rapidly blink green to indicate the instrument is creating a new file When the Mode LED slowly blinks red data is being recorded Each subsequent recording session creates a new file numbered sequentially Stop Recording To Stop recording data to your memory card the Instrument must be in Record mode Mode LED is flashing red 1 Hz Press and hold the Control Button until the Mode LED turns off about 1 second Release the Control Button Mode LED will rapidly blink red to indicate the instrument is closing the data file for use with playback and or anal ysis software Do not remove the memory card before the instrument completely closes the file When Mode LED turns green the memory card may be removed Removing the card before completion will cause Error Mode Mode LED is orange Note SD cards should be locked before inserting into a card reader Your PC may try to change the flash card format whenever it reads the data on your MMC or SD card if not locked causing it to lose the unique formatting required for DI 710 and DI 715B use If the unique format used by the DI 710 or DI 715B is modified the data lo
43. d a removable stor age slot the LED Mode table and a Control Button Rear Panel of DI 710 Fol pe Interface Rear Panel of DI 710 Stand alone Models Modes Static Cc Red N A Green Stby Orange 9 36 VDC eo OO Power Control Mode n Interface o Removable Storage MMC See Controls and Indicators on page 27 for a full explanation of each component Instrument Controls Indicators and Connections 25 DI 710 Series and DI 715B Series Hardware Manual DI 715B Models The Rear panel of your instrument can vary depending on your DI 715B model DI 715B stand alone models add a removable storage slot the LED Mode table and a Control Button Rear Panel PC connected N BjPATAQ 1 2 3 4 5 6 7 8 CE INSTRUMENTS CWANNEDS q b 2 EXCITATION Expansion O O 4 1 42 49 40 A57 460 7 8 9 36V 3A MAX C O Q O o O O A Interface Mode es daa Power V y Rear Panel Stand alone BjDATAQ 1 2 3 4 5 6 7 8 CE INSTRUMENTS CHANNELS P Expansion EXCITATION 1 2 3 4 5 6 7 8 of le Modes Static Slow Fast Red Record Close IN Green Standby Busy Orange Error Error 9 36V i 3A MAX Removable Memory O O O O O Ar Interface MMC SD Control Mode N BEDE comme Power O iu
44. d from the host instrument through the supplied dual ended power cable Each DI 75B channel consumes one channel from its host instrument in return for the isolated signal conditioned input it provides A maximum of one DI 75B instrument may be connected to any DI 715B instrument to get a total of 16 5B conditioned input channels Signal connections are made to the DI 75B through a removable screw termi nal block located on the back panel of the instrument Connecting the DI 75B to the Host Instrument NOTE The dual ended power cable is sized to fit when the DI 75B is stacked on top of the host instrument If these instruments are not in a stacked configuration do so before proceeding 1 Connect the appropriate end of the included expansion signal cable to EXPANSION on the rear panel of the host instrument 2 Connect the other end of the expansion cable to EXPANSION IN on the rear panel of the DI 75B Applying Power to the DI 75B A separate power supply is not required Power is obtained from the host instrument through the dual ended power cable supplied with the DI 75B Apply power using the following procedure 1 Unplug the five pin DIN end of the power adapter cable that is currently supplying power to your host instru ment and plug it into one of the DI 75B s power input jacks 2 Now plug one end of the dual ended power cable into the remaining power jack on the DI 75B and plug the other end into the host instrument power input
45. dly you could lose up to 255 seconds 4 minutes and 15 seconds of data 255 samples Use the following formula to determine the maximum amount of data loss at power failure 255 Seconds of data that COULD be lost Throughput Rate Note Switching memory cards before power is restored is not suggested because the data logger will automatically attempt to close the file Leave the memory card in until power is restored then allow the instrument to close the data file After a new file has begun stop recording The memory card may now be removed and read for analysis WiNDAQ Waveform Browser for MMC All files recorded in Stand alone data logger operating mode data saved to MMC or SD wdc files must be reviewed in WINDAQ Waveform Browser for MMC Data files recorded using WINDAQ Acquisition software PC operation wdq files must be reviewed in the standard WINDAQ Waveform Browser Even if connected to a PC WINDAO Waveform Browser cannot eavesdrop on the data being recorded to your memory card Recording must be stopped and the file must be closed to review the data DI 710 and DI 715B stand alone data loggers place 256 equally spaced event markers into all data files when record ing to MMC or SD This allows easier navigation through larger files Click on Event Markers in the View menu to access and jump to each of these event markers The Calculate command in the File menu is unavailable in WINDAQ Waveform Browser for MMC Use
46. dules se se se ee Ge AG Ge ee ee GR GRA ee ee ee Ge 61 DI 5B38 Strain Gage Input Modules Narrow amp Wide Bandwidth sess 62 DI 5B40 41 Analog Voltage Input Modules Wide Bandwidth Ge ee 64 DI 5B42 2 Wire Transmitter Interface Modules se ee ed Ge Ge ee eren 65 DI 5B43 Isolated DC Transducer Amplifier Input Module eee 66 DI 5B45 Frequency Input Modules i s iss 22 tete pep hei estre ti reri 68 DI 5B47 Linearized Thermocouple Input Modules eere 69 DI 5B48 Accelerometer Input Modules see se ee GR ee ee GR nnne 71 Table of Contents 1X DI 710 Series and DI 715B Series Hardware Manual 1 Introduction Congratulations on your purchase of the DI 710 or DI 715B data logger data acquisition system DI 710 and DI 715B Instruments feature a variety of options each explained fully in this manual Options include a USB or Ether net Interface PGL or PGH gain settings Stand alone capability and for DI 715B instruments thermocouple temper ature measurment capability using DI 5B47 modules DI 715B models accept DI 5B Industrial Signal Conditioning Modules Use the table below to determine the options included with your Instrument Options Model No Ethernet USB H Gain L Gain Stand alone Accepts 5B Modules DI 710 UH N Y Y N N N DI 710 UHS N Y Y N Y N
47. e Read Enable pin to I O Common pin 19 The DI 5B38 can interface to full or half bridge transducers with a nominal resistance of 1000 to 10kQ A matched pair of bridge completion resistors to 1mV at 10V excitation allows use of low cost half or quarter bridge trans ducers On wide bandwidth modules the 10kHz bandwidth allows measurement of high speed processes such as vibration analysis Strain Gage excitation is provided from the module by a very stable 10V or 3 333V source The excitation supply is fully isolated allowing the amplifier inputs to operate over the full range of the excitation voltage Full scale sensitiv ities of 2mV V 3mV V or 10mV V are offered With 10V excitation this results in a 20mV 30mV or 100mV full scale input range On wide bandwidth modules the input signal is processed through a preamplifier on the field side of the isolation barrier This preamplifier has a gain bandwidth product of 5MHz and is bandwidth limited to 10kHz On all modules after initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 5 Special input circuits on the DI 5B38 module provide protection of the signal inputs and the isolated excitation sup ply up to 240VAC Isolation Barrier
48. e area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity 5 Click on the General tab 6 Select the radio button Use the following IP address 7 Enter 169 254 0 1 in the space provided for the IP address Installation 12 DI 710 Series and DI 715B Series Hardware Manual 8 Enter 255 255 0 0 in the space provided for the Subnet mask Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 169 254 0 Subnet mask 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Altemate DNS server 9 Click on the OK button to close the Internet Protocol TCP IP Properties dialog box then click on the OK but ton in the Local Area Connection Properties dialog box for the changes to take effect 10 Install WINDAQ software see Installing WinDaq Software and the Dataq Instruments Hardware Manager on page 16 Installation 13 DI 710 Series and DI 715B Series Hardware Manual Installing an Ethernet Device via a
49. e see esee nennen 3 The DATAQ Instruments Hardware Manager eese ee ee ee ee Ge 3 FEL py cn E a sita cer ces AE lade 3 I ve 1610 UIE EE EE EE EE KO 5 Analog Inputs 22 RE Ere RR EE ARE OR OE EE EEN 5 Dieital IO OE EE EE N eee aia ae nie OE de 5 A T Characteristics stika titer A AS 6 Scanning Characters een ertet pee Ee Pa beet em oe ESE tn 6 Calibration eM 6 USB Interface 2 EE EE EE neut 6 Eth rn t Interface e rn astitit trip re e e ee eed 6 Removable Memory Stand alone Models only eese nennen 6 Real Time Clock tute RE EE EE ER ME OER 6 Controls Stand alone Models only ee ee RA RA AA Ge AA Re AR E Ge nana nc ee ee ee ee Ea 6 Indicators 5 NE OO VEE EE ME N EA 7 Transfer Rate 10 PC er ada de 7 Generale WEE OE eren eta rir repe EO OE ec OE EE 7 3 Installation nee EL N EE NE AE EE N ON S 9 sl ai RE EE M 9 Installing the Device Drivers USB Only see ee se GR ee ee GRA Ge ee Ge Ge RA ee ee ee 9 Installing an Ethernet Device Directly Connected to your PC or Connected via a Hub or Switch Where ONLY DI 71x Products are Installed er 228 ea st Ban BE se nn 11 Installing an Ethernet Device via a Distributed Network Without a DHCP Server 14 Installing an Ethernet Device via a Distributed Network with a DHCP Server 16 Installing WinDag Software and the Dataq Instruments Hardware Manager
50. ed Installation of an Ethernet device directly connected to the network card on your computer requires you to change the IP address of your network card I 71X Your PC DI IKE Note When installing an Ethernet device directly connected to your PC you MUST use a crossover cable provided Installation of an Ethernet device via an Ethernet hub switch containing ONLY DI 71x products also requires you to change the IP address of your network card DI 71X E DI 71X E Note For hubs that do not have an auto switching sensor usually older hubs you must not use a crossover cable 1 Find the Network Connections on your computer usually in the Control Panel 2 Double click on the Local Area Connection icon Local Area Connection Connected Firewalled LC A Intel R PRO 100 VE Network 3 Click on the Properties button Installation 11 DI 710 Series and DI 715B Series Hardware Manual 4 Select Internet Protocol TCP IP in the This connection uses the following items window and click on the Properties button Local Area Connection Properties General Authentication Connect using S9 Intel R PRO 100 VE Network Conne This connection uses the following items El Client for Microsoft Networks e File and Printer Sharing for Microsoft Networks il QoS Packet Scheduler v Intemet Protocol TCP IP Description Transmission Control Protocol Intemet Protocol The default wid
51. ed 0 Nui Computer Side SCMXR1 FUN 7v Backpanel Term Block 1 lt ne aaa 2 NC Isolated z 5VDC Field Side Power Power Oscillator n Power z Common Ordering Information MODEL INPUT RANGE OUTPUT RANGE DI 5B42 01 4mA to 20mA 1V to 45V Accessories 65 DI 710 Series and DI 715B Series Hardware Manual DI 5B43 Isolated DC Transducer Amplifier Input Module Each DI 5B43 displacement transducer module provides a single channel of displacement transducer input which is filtered isolated scaled and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 The DI 5B43 can interface to DC displacement transducers and other devices which require a precision 10VDC sup ply and produce a high level output The 1kHz bandwidth significantly reduces ripple and noise inherent in these devices Transducer excitation is provided from the module by a very stable 10V
52. ed properly WRONG APPROACH Circulating currents in signal shield induce noise on signal of interest DI 205 terminal strip Differential Amplifier Signal Source Ground loop caused by circulating currents The most common error made in connecting differential amplifiers is the tendency to ground both ends of a signal shield This causes current to flow through the shield and induces noise on the signal to be measured Ensuring that only one ground exists on the signal circuit eliminates this problem RIGHT APPROACH One ground on the signal circuit eliminates noise inducing ground loops DI 205 terminal strip Differential Amplifier Signal Source Potential difference no path for current to circulate Accessories 47 DI 710 Series and DI 715B Series Hardware Manual Isolated Signal Sources There are two considerations when connecting a differential amplifier to an isolated signal source The elimination of ground loops as described above and the use of bias resistors to provide bias current for the differential amplifier s positive and negative inputs The bias resistors should be chosen to be as low as possible but the value you use is dependent upon the output impedance of your signal source Generally the value of the bias resistor should be 10 times the output impedance of your signal source or higher Bias resistors greater than 1MO are not recommended DI 205 terminal strip
53. eet When in a differential operating mode the instrument sees the difference in voltage between the high and low inputs Differential amplifiers have the advantage of reducing common mode voltages those appear ing simultaneously and in phase on both inputs This capability may be leveraged to greatly reduce noise riding on a signal of interest Two signal measurement conditions govern the configuration of a differential channel input The signal to be mea sured is ground referenced or the signal to be measured is isolated from ground Ground referenced Signal Sources A ground referenced signal source is one with a local ground that may not be and probably is not at the same poten tial as the computer s ground This potential difference between signal ground and computer ground is referred to as a common mode voltage and is caused by a number of different factors Computer Signal Ground Source Ground Potential Difference Common Mode Voltage The most common of these is different physical locations of the computer and signal ground points Since wire is not a perfect conductor exhibiting zero resistance regardless of length a voltage drop however small will always be Accessories 46 DI 710 Series and DI 715B Series Hardware Manual present The differential amplifier is unique in its ability to measure signals originating from sources with different ground potentials relative to the computer provided it is connect
54. f the isolation barrier The converted dc signal is then chopped by a proprietary chopper circuit and transferred across the transformer isolation barrier suppressing transmission of common mode spikes and surges The computer side circuitry reconstructs filters and converts the signal to industry standard outputs Modules are powered from 5VDC 15 For current output models an external loop supply is required having a compliance voltage of 14 to 48VDC Connec tion with series load is between Pin 20 and Pin 19 Isolation Barrier Conversion lsochopper EXC 20 gt V or AC Source In Ter Amplifier Pat Pending Surge l i 1 Suppression i NZ In and 19 mm Protection V V 1 0 Common de I A l 22 EXC Isolated 5 RD EN i Computer Side Power 1 Backpanel Term Block i rue seed Lua LLL 1 rm 1 I e Isolated P 2 Field Side pd Current Input Models Only Power Oscillator Add Jumpers for Current Input Modules e 1 provided with 5B33 06 07 Ordering Information MODEL INPUT RANGE OUTPUT RANGE DI 5B33 01 100mV OV to 5V DI 5B33 02 1V OV to 5V DI 5B33 03 10V OV to 5V DI 5B33 04 150V OV to 5V DI 5B33 05 300V OV to 5V Accessories 56 DI 710 Series and DI 715B Series Hardware Manual DI 5B34 Linearized 2 or 3 Wire RTD Input Modules Each DI 5B34 RTD input module provides
55. file It could take up to 30 seconds to close the file depending on the memory card used For Ethernet models you may also use the Stop Recording to SD Mem ory command in the DATAQ Instruments Hardware Manager See also Stop Recording on page 28 Access MMC SD data using the uploader software provided in installation Ethernet models or by removing the memory card and using a card reader Data files open in WINDAQ Waveform Browser for MMC see WinDaq Waveform Browser for MMC on page 37 Note To read the data files SDs should be locked before inserting into a card reader If the SD is not locked Windows may modify the file system and the SD will be unreadable to your instrument requiring you to reformat the card MMCs may require you to reformat every time you review the data Troubleshooting Use the following chart for errors and resolution Problem Possible Cause s Resolution When attempting to initiate a recording session the LED blinks green for about 5 10 seconds then quickly blinks orange then back to green Memory card not inserted Press memory card firmly into the slot until you hear a slight click to indicate proper insertion When attempting to initiate a recording session LED blinks orange then turns green SD is locked write protected Unlock the SD Card Memory card is full Reformat the memory card Memory card is unusable or damaged You need a new memo
56. gain settings of 1 2 4 8 calibration 4 800 Hz maximum sampling rate up to 14 400 Hz when in Stand alone data logger operating mode 0 048 samples second minimum sampling rate 0 0017 samples second when recording to a memory card Introduction 1 DI 710 Series and DI 715B Series Hardware Manual e 14 bit A D converter for high resolution measurement accuracy e 16 entry input scan list allows you to scan any sequence of input channels at any available gain e The Stand alone option allows the user to configure a recording session through their PC then record data in the field to an SD card without being connected to their PC Analog Inputs DI 710 models provide 16 single ended or 8 differential analog inputs programmable per channel that allow your analog signals to be converted into 14 bit digital data via an on board A D converter Two removable 16 position ter minal blocks allow you to easily connect and record signals The DI 710 features the following software programma ble input measurement ranges L Models H Models 10V full scale measurement range at a gain of 1 10V full scale measurement range at a gain of 1 1V full scale measurement range at a gain of 10 5V full scale measurement range at a gain of 2 100mV full scale measurement range at a gain of 100 2 5V full scale measurement range at a gain of 4 10mV full scale measurement range at a gain of 1000 1 25V full scale measurement ran
57. ge at a gain of 8 Gains of 100 and 1000 are limited to max throughput of 7200 and 900 Hz respectively when acquiring more than one channel of data DI 715B models provide 16 fixed single ended analog inputs that allow your analog signals to be converted into 14 bit digital data via an on board A D converter Differential input is not supported Channels 9 16 are accessible through use of a DI 705 see The DI 705 on page 42 The DI 715B features the following software programmable input measurement ranges Measurement Range Gain Setting 10V full scale 1 5V full scale 2 2 5V full scale 4 1 25V full scale 8 Digital Input and Output All DI 710 and DI 715B models contain 8 software programmable digital lines bits for input output operations These lines provide an interface for the transfer of data between user memory and a peripheral device connected to the instrument Digital inputs can monitor alarms or sensors with TTL outputs while digital outputs can drive TTL inputs on control or measurement equipment Remote control can be utilized with bits 0 and 1 and is easily accessed using WINDAQ Acquisition software or for stand alone models in the stand alone setup panel To avoid using an analog input channel for Digital I O Channel 17 may be enabled as the digital channel To use the Remote Control features in WINDAQ Acquisition software either Channel 1 or Channel 17 must be configured as the Digital Input
58. gger may require you to reformat the memory card Formatting the Memory Card Formatting the card completely removes all data To format your memory card the instrument must be in Standby Mode Mode LED is Green Press and hold the Control Button until the Mode LED turns red about 5 seconds Release the Control Button The Mode LED will blink red to indicate the Instrument is formatting the card When the Mode LED changes back to green formatting is complete Mode LED should be green to indicate successful comple tion Formatting is for use with the instrument used to format the card To use a memory card with a different instru ment you will have to reformat the card Reconfigure Instrument To configure your instrument to the default factory data acquisition session settings press and hold the Control Button during power up i e while plugging the instrument in Mode LED will flash bright green then dim to indicate that the instrument is configured Release the Control Button The default settings are 16 channels enabled as single ended inputs 300 samples per second per channel sample rate gain setting of 1 for each channel Fix Errors The Control Button can also be used to fix some common operating errors When the instrument is in Error mode some action must be taken to fix the error before you can use it Generally the Control Button can be used to make the instrument operational See the Error mode in Mode LED Indicator on page
59. hannel is configured by using two single ended inputs Use the following illustration for input connections S GND S GND input Signal Leads CHAN 1 HAN 1 input O Signal Leads CHAN 9 1 CHAN 9 1 S GND S GND Channel 1 configured Channel 1 configured for single ended input for differential input Note that when an input channel is configured for differential operation the binding post associated with that chan nel s high input assumes the channel number Connecting a Single ended Amplifier A single ended amplifier is the most straightforward approach to connecting signals to the DI 205 However to derive adequate performance the use of a single ended amplifier requires that the signal to be measured is relatively high level greater than or equal to 1V full scale and the distance from the signal source to the DI 205 is relatively short less than 15 feet Assuming these conditions exist a single ended amplifier may be connected according to the diagram below DI 205 Terminal Strip yo 1 of 16 analog inputs Signal Source 1 of 16 analog grounds Accessories 45 DI 710 Series and DI 715B Series Hardware Manual Connecting a Differential Amplifier A differential channel configuration is a special case approach to signal measurement that should be used with all low level measurements less than 1v or when the signal to be measured is located far away from the DI 205 greater than 15 f
60. hannel of analog input which is filtered isolated amplified and converted to a high level analog voltage output see block diagram This voltage output is logic switch con trolled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 A precision 20 current conversion resistor is supplied with the DI 5B32 module see block diagram for installation details Isolation Barrier 1 I EXC Isochopper 20 Amplifier gt Vour Surge Pat Pending Suppression lin and 19 Protection I V V 3 1 0 Common Eod Y EXC 22 Isolated 5 RD EN Computer Side l Power 0 1 plug in i I 1 Backpanel Term Block I 1 La ET iy E am E NC 2 NC Isolated p Field Side oust P Oscillator ower Signal filtering is accomplished with a six pole filter which provides 95dB of normal mode rejection at 60Hz and 90dB at 50Hz Two poles of this filter are on the field side of the isolation barrier and the other
61. ifferential programmable per channel DI 715B Fixed single ended IMQ 1MQ each input to common 10uA for a 10V input single channel Auto zero 2nA single channel 30V DC or peak AC 30V DC or peak AC 80db gain 1 1KQ unbalance 75db 100Q unbalance 50ppm C 0 25uV C PC connected models Conditional over sampling Stand alone models None Analog measurement range software selectable per channel Accuracy and Resolution DI 710 L Models DI 710 H and DI 715B Models Gain Range Accuracy Resolution Gain Range Accuracy Resolution 1 10V 05 FSR S0uV 1 22mV 1 10V 05 FSR 50uV 1 22mV 10 1V 05 FSR 50uV 122uV 2 5V 05 FSR 50uV 6l0uV 100 100mV 05 FSR 450uV 12 2uV 4 2 5V 05 FSR 50uV 305uV 1000 10mV 05 FSR 50uV 122uV 8 1 25V 05 FSR 50uV 1534 V DI 715B Models These specifications are for the unit itself excluding DI 5B module s Test Condition Single channel 100 S s Digital VO Channels Configuration Output voltage levels Output current Input voltage levels averaging mode For DI 715B this spec doesn t include 5B or CJC error 8 bi directional bits Each bit is programmable as an input or output Minimum 1 3V E 2 5mA sourcing Maximum 0 0 4V E 2 5mA sinking Maximum source 2 5mA Maximum sink 2 5mA Minimum required 1 2V Maximum allowed 0 0 8V Specificati
62. ing a DI 705 Channel 17 may be enabled as Digital but must be accessed using a DI 705 as well see also The DI 705 on page 42 To use the Remote Control Functions of WINDAQ Acquisition software Channel 17 or Channel 1 must be enabled as the Digital Input Channel Channel Selection Channels 1 23456 8 90 as the digital channel and is only accessible through a DI 705 with CABL 7 Click to select check or deselect Double click to select differential Click right to select digital input 1 MUX letters occupy the expansion inputs OK Cancel Operation 31 DI 710 Series and DI 715B Series Hardware Manual Calibration and Gain Settings Each DI 5B module has a sticker on it with information regarding Input Units and Output Volts This information should be used for calibration For example if using a DI 5B47K 13 the Input is 100 C to 1350 C and the Output is OV to 5V High Low Calibration Use the following diagram as a guideline for the High Low calibration method Channel 1 Low Calibration Input Level 0 Volt TU Low Cal Value H 00 Engr Units degC Cancel Channel 1 High Calibration Input Calibrator Engr Calibrator Input Level Units Value Units Low 000 Volt 100 000 degC High 5 Volt n 350 degC Cancel Gain should be set to 2 4 or 8 for better resolution depending on your actual input range Note that the Low Calibra tion information is included in the High Calibrati
63. inputs or a DI 75B adds up to 8 5B signal conditioned inputs The Digital I O may also be accessed through the Expansion connector using a DI 705 See The DI 705 on page 42 for more information Power Input Jack For Ethernet models and Stand alone models Power must be applied with the included power adapter or with an alternate appropriate source 9 36 VDC 2 watts max External power is not required for DI 710 UH and DI 710 UL models Power is derived through one of your PC s USB ports or through a powered USB hub If using an alternate power source with the DI 715B refer to the following for pin out VEN V Common Power Switch DI 715B Models Switches power on off If power is on the Mode LED will be on Ground This ground lug should always be connected to a solid chassis or earth ground This connection is mandatory for the unit to meet CE guidelines Instrument Controls Indicators and Connections 27 DI 710 Series and DI 715B Series Hardware Manual Interface Port The Interface port allows you to connect the instrument to your PC via USB or Ethernet cable Control Button Stand alone Models The Control Button can be used to stop or start recording data to your memory card MMC or SD when using the instrument as a stand alone data logger The Control Button can also be used to reconfigure the instrument to factory default settings and to re format memory card files left open due to power failure or other
64. j DATAQ INSTRUMENTS The way PC based instrumentation should be DI 710 Series 16 Channel USB or Ethernet data logger DI 715B Series Ethernet Data Logger with Signal Conditioned Inputs User s Manual Manual Revision S Copyright 2009 by DATAQ Instruments Inc The Information contained herein is the exclusive property of DATAQ Instruments Inc except as otherwise indicated and shall not be reproduced transmitted transcribed stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ Instruments hardware and software products are not designed to be used in the diagnosis and treatment of humans nor are they to be used as critical components in any life support systems whose failure to perform can rea sonably be expected to cause significant injury to humans DATAQ the DATAO logo and WINDAQ are registered trademarks of DATAQ Instruments Inc All rights reserved DATAQ nz J INSTRUMENTS Designed and manufactured in the United States of America M 100762 Warranty and Service Policy Product Warranty DATAQ Instruments Inc warrants that this hardware will be free from defects in materials and workmanship under no
65. jack Accessories 49 DI 710 Series and DI 715B Series Hardware Manual Features Controls and Indicators DI 75B Front Panel The clear acrylic front panel allows easy identification of all installed DI 5B modules To access the 5B backplane remove the front panel and bezel by removing the two outside screws 1 Remove front panel and bezel by removing the two screws 2 DI 5B Modules are installed to the 5B backplane using the set screw 5 DATAQ INSTRUMENTS g 13NNVHO 1 19NNVHO e o gt z z m r o O Q O O O o O o o o 0000 G TINNVHI 0000 DI 5B modules are installed on or removed from the socketed 5B backplane and are secured with a non removable mounting screw Each channel position is labeled CHANNEL 1 CHANNEL 2 etc on the socketed backplane The DI 5B modules can be mixed or matched in any combination suitable for the application and are identical in pinout and size so it doesn t matter which module gets plugged into which channel position Channels 1 through 8 of the DI 75B are designated Channels 9 through 16 consecutively on the DI 715B Note When reattaching the front panel be sure not to overtighten the screws Accessories 50 DI 710 Series and DI 715B Series Hardware Manual DI 75B Rear Panel EXPANSION OUT can be used to access the Digital VO of the DI 715B using a DI 705 and CABL 7 CHANNELS 1 42 49 44 49 48 af e 38
66. n this case an alternate power source is required Any suitable power source 9 to 36 volts DC at 3A maximum may be connected to either power input jack to provide the necessary power EXPANSION OUT connector Used to connect to a DI 705 in order to access the Digital I O of the DI 715B Connect the appropriate end of a CABL 7 to this connector and connect the other end of the cable to the DI 705 See The DI 705 on page 42 for more information EXPANSION IN connector Connects the DI 75B to its host instrument Configuring Channels for the DI 75B In WINDAQ Acquisition software channels are enabled or configured for acquisition with the channel selection grid The channel selection grid is accessed by selecting Edit gt Channels in the SET UP operating mode of WINDAQ software Each box in this grid potentially represents an input channel An input channel is enabled by clicking the desired box Which box you click which mouse button you click with and how many times you click the mouse button deter mines whether the input channel is enabled for single ended operation or operation defined by the DI 5B module Accessories 52 DI 710 Series and DI 715B Series Hardware Manual The following channel selection grid is typical when a DI 75B is used with a DI 715B A total of sixteen signal con ditioned inputs are available for data acguisition Channel 17 may be enabled as Digital but must be accessed using a DI 705 with CABL
67. nections 22 DI 710 Series and DI 715B Series Hardware Manual Differential inputs occupy two channels with the lowest numbered channel in the pair assuming the positive input and the channel number Refer to the following for differential pairs differential pairs positive differential channels negative differential channels For example to configure Channel as a differential input Connect Channel as the positive input and channel 9 as the negative input the pair is referred to as channel 1 differential The following illustration shows chan nels 1 and 9 configured as channel 1 differential Signal Optional Ground shield Signal Digital Input Output DG 5V RY AG Analog Channels 0 1 3 2 D Yee 4 5 7 10 Channel 1 configured for differential input 37 pin D sub connector The two removable 16 port screw terminal blocks may be replaced by a 37 pin D Sub Connector for all DATAQ Instruments DI 710 Series products add a D to the model number Refer to the following diagram for pin out wt e e g EN Soe o OP Nr D NP N S o ae qu ge g Ps PES aoo SH Ny 5 AO 9 DAN NON ed DO 00000000000000000090 NM AS A ad WV 65 ab ES Vv VV VV VO VV wm WIN Y b DT OD A A DA o9 o O Ob o OV ON E MMP PF T R ES Note Digital I O connections cannot be used concurrently DIO and DOO are directly connected inside the DI 710 as are DII and DOI DI2 and D
68. nput Modules eene 69 DI 5B48 Accelerometer Input Modules see se ek Ge ee ee RA ee ee Ge Ge ee ee ed en 71 Accessories 41 DI 710 Series and DI 715B Series Hardware Manual The DI 705 The DI 705 can be used with DI 710 D models see 37 pin D sub connector on page 23 and with DI 715B instruments Using the DI 705 with DI 710 D Models The DI 705 plugs into the 37 pin D sub connector of the front panel of DI 710 D models and provides convenient screw terminal access to analog inputs analog outputs and the Digital I O Note The digital I O is not available in stand alone mode The screw terminals accept 16 22 gauge wire and each is silk screened with the corresponding D connector pin number see 37 pin D sub connector on page 23 The DI 705 also features a 37 pin male pass through connector which allows you to connect our BNC cable model number CABL 4 or our 5B back plane cable model number CABLE 1 or any 37 pin DAS 16 compatible cable to the DI 710 while still allowing screw terminal access Pass through connector Signal connections are made Plugs directly into DI 710 D models to the screw terminals Any combination of single ended or differential channels may be connected to the DI 705 but keep in mind a differ ential channel uses two analog inputs Configure single ended and differential channels on the DI 705 the
69. o a PC data recording sessions may be configured and data may be acquired using WINDAQ Acquisition software just the same as if the model were a PC based instrument This makes all the features of WINDAQ Acquisition software available including triggering user annotation user commented event markers appending and stop pause data recording stand alone data logger operation does not support these features When taking your stand alone model out into the field to use as a stand alone data logger you can record data to an MMC or SD without the use of a PC Data sessions can be configured for a specific job using the included configura tion software installed when WINDAQ is installed All data recorded to the memory card is fully WINDAQ compati ble and can be converted then reviewed and analyzed with WINDAQ Playback software Operation 33 DI 710 Series and DI 715B Series Hardware Manual PC connected operation The DI 710 or DI 715B Instrument enters PC Operation Mode when the instrument is connected to the PC and the user initiates WINDAQ Acquisition software As soon as PC Operation Mode is entered the Control button is deacti vated and all the features of WINDAQ Acquisition Software are accessible Consult the context sensitive help files or your Fast Start WINDAQ Software Manual for directions on using the WINDAQ software package Note When running WINDAQ Acquisition software over the internet unpredictable latencies may occur e
70. o continue installation Click Cancel to exit without installing 14 When prompted to Select a Program Manager Group specify a destination or group window in the Start Menu for WINDAQ software icons It is recommended that you accept the default 15 In the Installation Option Dialog box specify whether you want all users to have access to WinDaq software or just the current User Click Yes to allow all users to have access click No to allow just the current user to have access 16 After WINDAQ Software installs you will prompted to install WINDAQ XL Trial Version and Advanced CODAS Analysis software If you wish to install either software click on Yes in the appropriate dialog box Follow the on screen prompts to complete installation 17 Installation is complete you will now see a Successful Installation box click on OK to exit WINDAQ Installa tion If you purchase more devices at a later date you must run the installation again with all devices old and new plugged in 18 To run WINDAQ Data Acquisition software or the Stand alone Set Up software go to the appropriate program group specified above default is Start Programs WINDAQ and click on Dataq Instruments Hardware Manager All DATAQ Instruments software is located in the same program group Activation of WINDAQ High Speed Option Activation is required for continued use of WINDAQ HS High Speed option to ensure compliance with the Software License Agreement The
71. on dialog box for easy reference If the High Calibration is entered first that information would appear in the Low Calibration dialog box Fixed Calibration Use the following diagram as a guideline for the Fixed calibration method Channel 1 Fixed Calibration High Calibrator C Baseli Full Scale Engr Value 1 350 Low Calibrator f Baseline Full Scale Engr Value j 00 Engr Units degC yoa cvs coent Operation 32 DI 710 Series and DI 715B Series Hardware Manual Since the Lowest end of the input range is 0 Volts select the Baseline option for the Low Calibrator Gain should be set to 2 4 or 8 for better resolution depending on your actual input range Gain DI 5B Modules generally output between 5 and 5 Volts The DI 715B is designed to accept 10 Volt signals A Gain of at least 2 should be set to each signal conditioned input to get the most accurate readings To change the Gain click on Channel Settings in the Edit menu elected Channel Channel 1 Settings Gain FS Volt FS Volt Acguisition Method 10 000 5 0000 2 5000 1 2500 Average Last Point Maximum Click here to set gain to 2 RMS r r C Minimum C r Frequency Input Type Linear C C E r Reset Cal Cancel Next Stand alone Models Stand alone Models can record data directly to a MultiMedia Memory Card MMC or a Secure Digital Card SD as well as record data to a PC When connected t
72. onnecting the DI 75B to the Host Instrument 0 sesse ee se ee Ge ee ee Ge GR Ge ee ee Ge 49 Applying Power to the DI 75B sei in 49 Features Controls and Indicators esse ee ee ee ee Ee ee Re Re Re ee e ee ee ee ee ee ee ee ee ee 50 DE75B Fi nt Panel ss sal ra 50 DESB Rear Panel 2 se ar aa A a 51 Removable Screw Terminal Block se ee ee Ge Ge ee RA Ge ee ee Ge 52 POWER uie N OE ER OU OR EE ER o 52 POWER unput Jacks cuina NE MA EE N 52 POWER status lamp ee devs Se sas Vee ee te be a Ee RUHR 52 POWER EOW lamp susi shies be sap ite ep de De ais hia sa eb ea ees Ee she 32 EXPANSION OUT connector ereenn sede see ss es se ee be ee Ee eere ee See a innere Se se Ee Ee e 52 EXPANSION IN connector metida de reete etario italia 52 Configuring Channels for the DI 75B sees Ge renna 52 Calibration 44e tee te e euet Re batte dias 53 GA N N OE RE AE 53 Installing Shunt Resisters au EE peer ie RE EE EE Det pep ced 53 DESB Modules OE RE AE EO io 54 DI 5B30 31 Analog Voltage Input Modules Narrow Bandwidth ss 54 DI 5B32 Analog Current Input Modules se se ee ee Ge Ge ee enne nennen 55 DI 5B33 Isolated True RMS Input Modules esee 56 DI 5B34 Linearized 2 or 3 Wire RTD Input Modules eene 57 DI 5B35 Linearized 4 Wire RTD Input Modules 20 0 0 eee se ee ek Ge ee ee RA GRA nnne 59 DI 5B36 Potentiometer Input Mo
73. ons 5 DI 710 Series and DI 715B Series Hardware Manual A D Characteristics Type Resolution Monotonicity Conversion Time Scanning Characteristics Maximum sample throughput rate When acquiring more than one channel at a gain of 100 max throughput is 7200 Hz When acquiring more than one channel at a gain of 1000 max throughput is 900 Hz Successive Approximation 14 bit 2 LSB 69us PC connected 4 800 Hz Stand alone 14 400 Hz Assumes SD memory latencies of 80 milliseconds or less Minimum sample throughput rate Maximum scan list size Sample buffer size Calibration Calibration Cycle USB Interface Connector Protocol Ethernet Interface Type Connector Protocol Server Type PC connected 0 0034 Hz Stand alone 0 0017 Hz 17 entries 2kb One year USB USB 1 1 10 100Base T RJ 45 TCP IP DHCP Removable Memory Stand alone Models only Type Capacity Real Time Clock Type Resolution Accuracy Secure Digital SD 16MB to 2GB Date hour minute second 1 second 20 ppm Controls Stand alone Models only Single push button Provides manual control over Record and Standby modes Specifications 6 DI 710 Series and DI 715B Series Hardware Manual Indicators Stand alone models PC connected models Transfer Rate to PC Real Time From MMC or SD Memory Ethernet models only General Panel Indicators Panel Controls Panel
74. ord Indicates the instrument is acquiring and recording data to your memory card Do Not Red 1Hz Remove Memory Card Fast Flashing Close Indicates the instrument is closing the recording session Do Not Remove Memory Red Card Each recording session must be completed before removing the card PC connected operation Slow Flashing Record Indicates the instrument is running and acquiring data for display and or recording to Red O 1Hz disk Occurs when WINDAQ Acquisition is running Green Standby Indicates WINDAQ has been deactivated and the instrument is in Standby Mode The Mode LED Indicator will also flash green just before recording to disk to indicate ini tialization Removable Storage Slot MMC Stand alone Models Use any MultiMedia Card MMC or Secure Digital Card SD from 16MB to 2GB Push card completely into slot Press to release eject memory card when recording is complete Recommended Flash Card Lexar Professional 133X 2 Gigabyte Secure Digital Flash Memory model 101014 2G tested and configured specifically for DI 710 and DI 715B use by DATAQ Instruments Inc Some memory cards may not be fast enough for the instrument Lexar memory cards are available through the DATAQ web site www dataq com as are SD card readers manufacturer varies Installing a Shunt Resistor in DI 715B Models To use the Current Input Modules DI 5B32 and DI 5B42 you must install a shunt resistor provided wi
75. ot passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway XP warning amp Windows can t verify the publisher of this driver software gt Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information i v See details Vista Warning 6 After the Drivers are installed click Finish to close the Found New Hardware Wizard Windows should prompt you that the device has been installed properly 7 Repeat this process for each instrument After all device drivers have been installed install WINDAQ software see Installing WinDaq Software and the Dataq Instruments Hardware Manager on page 16 Installation 10 DI 710 Series and DI 715B Series Hardware Manual Installing an Ethernet Device Directly Connected to your PC or Connected via a Hub or Switch Where ONLY DI 71x Products are Install
76. p to 240VAC 3 Wire Potentiometer i 2 Isolation Barrier IsochopperTM 4 4 Amplifier 20 gt Vour Surge Pat Pending Suppression 3 and 19 D Protection V Y VO Common 2 Wire i A Ms Slidewire Isolated 75 RD EN Computer Side Power Backpanel Term Block Isolated Field Side Power Oscillator Power Common Ordering Information MODEL INPUT RANGE OUTPUT RANGE DI 5B36 01 0 to 1000 OV to 5V DI 5B36 02 0 to 500Q OV to 5V DI 5B36 03 0 to 1kQ OV to 5V DI 5B36 04 0 to 10kQ OV to 5V Accessories 61 DI 710 Series and DI 715B Series Hardware Manual DI 5B38 Strain Gage Input Modules Narrow amp Wide Bandwidth Each DI 5B38 Strain Gage input module provides a single channel of Strain Gage input which is filtered isolated amplified and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 th
77. r four are on the com puter side After the initial field side filtering the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5VDC 5 A special input circuit on the DI 5B30 and DI 5B31 modules provides protection against accidental connection of power line voltages up to 240VAC Isolation Barrier EXC Y Isochopper 20 4 Amplifier gt Vout In O Surge Pat Pending Suppression Vin 3 and 19 Q Protection V RV S VO Common 702 I A SZ 22 Exc Y Isolated LS RD EN 1 Computer Side Power V I Backpanel Term Block LAAN 1 E NC 2 E ne Isolated p DE Field Side ue Power Oscillator Power Common Ordering Information MODEL INPUT RANGE OUTPUT RANGE DI 5B30 01 TOmV to 10mV 5V to 45V DI 5B30 02 50mV to 50mV 5V to 45V DI 5B30 03 100mV to 100mV 5V to 45V DI 5B31 01 IV to 1V 5V to 5V DI 5B31 02 5V to 45V 5V to 5V DI 5B31 03 TOV to 10V 5V to 45V DI 5B31 07 20V to 20V 5V to 45V DI 5B31 09 40V to 40V 5V to 45V CSA certification pending Accessories 54 DI 710 Series and DI 715B Series Hardware Manual DI 5B32 Analog Current Input Modules Each DI 5B32 current input module provides a single c
78. rmal use and service for a period of one year from the date of shipment DATAQ Instruments obligations under this warranty shall not arise until the defective material is shipped freight prepaid to DATAQ Instruments The only responsibility of DATAQ Instruments under this warranty is to repair or replace at its discretion and on a free of charge basis the defective material This warranty does not extend to products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instruments shall have no liability for incidental or consequential damages of any kind arising out of the sale installation or use of its products Service Policy 1 All products returned to DATAQ Instruments for service regardless of warranty status must be on a freight pre paid basis 2 DATAQ Instruments will repair or replace any defective product within 5 days of its receipt 3 For in warranty repairs DATAQ Instruments will return repaired items to the buyer freight prepaid Out of war ranty repairs will be returned with freight prepaid and added to the service invoice READ BEFORE CONNECTING INPUT SIGNALS TO YOUR DI 710 The DI 710 data acguisition device you have purchased and are about to use is NOT an ISOLATED product This means that it is susceptible to common mode voltages that could cause damage to the device SUCH DAMAGE I
79. ry card Recording is initiated but only runs for a short time when LED blinks orange and stays orange Memory card read write speed in SPI mode is too slow to record data as specified Recording is initiated in Circular Memory configuration but when the file attempts to wrap the LED blinks orange and stays orange Memory card read write speed in SPI mode is too slow to record data in cir cular memory configuration Try lowering the sample rate first If problem persists purchase a new card recommended Lexar Profes sional 133X 2 Gigabyte Secure Digital Flash Memory Operation 35 DI 710 Series and DI 715B Series Hardware Manual LED is green but I cannot format a memory card The instrument is looking for a file that has not been closed possible due to power failure Reinsert the correct memory card and press the control button for about 1 second until LED turns off and release The instrument gives you three chances to find the correct file if it does not you must format whatever card is there to begin a new recording session Mode LED will not change from error state orange This can be caused by switching memory cards during a power failure without giving the instrument a chance to close the data file Remove the memory card and unplug the device Restore power to the device LED should turn green Press and hold the control button for about 1 second until
80. same way as on the DI 710 See Instrument Front Panel on page 22 for more information Accessories 42 DI 710 Series and DI 715B Series Hardware Manual Using the DI 705 with DI 715B Instruments Plug the DI 705 into CABL 7 and connect CABL 7 to the EXPANSION port on the rear panel of the DI 715B to access the Digital I O and analog channels 9 16 Digital I O may also be accessed through a DI 75B channel expander using the EXPANSION OUT port on the rear panel of the DI 75B 7 The screw terminals accept 16 22 gauge wire and each is silk screened with a pin number below Signal connections are made to the screw terminals Connect to EXPANSION on DI 715B or EXPANSION OUT on DI 75B The DI 715B accepts single ended inputs only The Digital I O may be enabled as Channel 17 Note The Digital I O is not available in stand alone mode Pinout for the DI 705 is as follows screw terminal in bold 1 N C 11 CH8 21 DI6 31 CHI5 2 DI5 12 CH7 22 DO2 32 CH14 3 DO3 13 CH6 23 DOO 33 CH13 4 DOI 14 CH5 24 DL 34 CH12 5 DD 15 CH4 25 DIO 35 CHII 6 DII 16 CH3 26 DO4 36 CH10 7 Power GND 17 CH2 27 DO7 37 CH9 8 DO6 18 CH1 28 AGD 9 N C 19 AGD 29 DI7 10 DO 5 20 DI4 30 CH16 Note Digital VO connections cannot be used concurrently DIO and DOO are directly connected inside the DI 715B as are DIT and DO1 DR and DO2 etc Accessories 43 DI 710 Series and DI
81. screwdriver for connecting signal leads to the screw terminal s e Installation Guide pamphlet included in CD case If an item is missing or damaged call DATAQ Instruments at 330 668 1444 We will guide you through the appropri ate steps for replacing missing or damaged items Save the original packing material in the unlikely event that your unit must for any reason be sent back to DATAQ Instruments Installing the Device Drivers USB Only These USB devices require two drivers to be installed a Serial Port and a USB driver Ethernet models do not require any drivers to be installed See Installing WinDaq Software and the Dataq Instruments Hardware Manager on page 16 to install Ethernet products 1 Ifprovided plug the appropriate end of the power cable into the instrument jack labeled Power and the other end into a standard outlet DI 710 UL and DI 710 UH models do not require an external power source Power is derived from the PC through the USB interface For DI 715B models turn on the power using the Power Switch The Mode LED will be on when power is applied 2 With your computer powered Windows running and all other applications closed plug the appropriate end of the supplied USB communications cable into the USB port labeled Interface on the rear panel of the instru ment Connect the other end of this cable to one of your computer s USB ports Note If using a USB hub with a DI 710 UH or DI 710 UL use a powered USB h
82. ses and the remaining five pole programmable Bessel filter is located on the system side High pass filter ing is achieved through a second order passive filter located on the field side If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 The DI 5B48 offers the option of setting the constant current source for sensor excitation to common values of 4mA or 9mA with a compliance voltage of 24VDC Programmable gains of 1 10 and 100 are selectable and the module offers a 10V output The required supply level is 5VDC 5 To ensure protection of expensive data acquisition equipment the DI 5B48 module signal inputs and sensor excita tion outputs are protected against accidental connection of voltages up to 240Vrms Isolation Barrier IsochopperTM n 20 Amplifier Program Vour Pat Pending LPF 19 V V m V O Common ICP or IEPE or LIVM Sensor NV 5 RD EN Isolated Computer Side Power Program Gain Stage n Backpanel O ra Term Block Li AAA 1 1 1 a Isolated Excitation Source E NC i 1 2 1 NC E V Ys svoe l li 1 Isolated P V Field Side ona Oscillator Power 16 y pum don Common rdering Information MODEL INPUT RANGE OUTPUT RANGE BANDWIDTH ISOLATION VOLTAGE DI 5B48 01 10V max 10V 2 5kHz to 20kHz 1500
83. sis and review features See WinDag Waveform Browser for MMC on page 37 for more information regard ing WINDAQ Waveform Browser for MMC software Data may be recorded using a circular FIFO memory configuration allowing you to record data nearly indefinitely or in a non circular configuration allowing you to stop recording when your memory card is full Select the desired memory configuration using the Stand alone Set Up software inside the Dataq Instruments Hardware Manager Note SanDisk MMC SD memory cards have a lifetime expectancy of about 100 000 write actions Each time data wraps you will use one write action each singular data file uses two write actions start and stop If used properly a memory card will last years See your memory card s specifications to determine lifetime expectancy The Stand alone Set Up Panel The Stand alone Set Up software installed with WINDAQ accessible in the WINDAQ program group through the Dataq Instruments Hardware Manager allows you to customize each data recording session before taking the instru ment out into the field The default settings i e if you do not configure the instrument are 16 single ended channels enabled at 300Hz sample rate and a gain of 1 The default configuration can be reset at any time on the instrument by holding the Control button in when applying power Context sensitive Help is provided within the configuration soft ware Press F1 to access Help topics related to the c
84. source The excitation supply is fully iso lated allowing the amplifier inputs to operate over the full range of the excitation voltage This feature offers signifi cant flexibility in real world applications Ten full scale input ranges are provided from 1V to 10V producing 5V full scale output The input signal is processed through a preamplifier on the field side of the isolation barrier This preamplifier has a gain bandwidth product of 5MHz and is bandwidth limited to 1kHz After amplification the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 45 Special input circuits on the DI 5B43 module provide protection of the signal inputs and the isolated excitation supply up to 240VAC Isolation Barrier 1 1 Amplifier SS vour Surge Pat Pending DC LVDT Suppression or Other and N 19 Transducer Protection el ay E S VO Common Isolated A A RF Excitation 22 s Isolated RD EN ource Computer Side i Power WY LA U en I 1 Backpanel Term Block NN rs 1 rn lt NC 2 NC I V Isolated e E 5VDC V Field Side AE Power scillator Power I Common Accessories 66 DI 710 Series and DI 715B Series H
85. specially at higher sample rates The unit generally will continue to acquire data after a latency but there will be gaps in your data Networked operation as a data acquisition server The Ethernet option allows data access from anywhere on a local area network LAN or DHCP server A DI 710 or DI 715B configured for Stand alone operation and an Ethernet interface transparently becomes like any other com puter on the network able to share data whenever and wherever it is needed This can be over the LAN to a PC on the other side of the facility or over the Internet to a PC on the other side of the world Furthermore Stand alone instru ments can be easily added to existing networks Its server functionality means that it does not require a dedicated net work to operate efficiently Data is locally stored to MMC SD memory where it is available for upload using the Uploader software only on demand and as network bandwidth permits In this manner Stand alone instruments with Ethernet interfaces are fully compatible with the intrinsic non preemptive nature of Ethernet networks Stand alone data logger operation Use your Stand alone model as a stand alone data logger to record a WINDAQ compatible waveform file onto a Mul tiMedia Card MMC or Secure Digital Card SD After recording insert the memory card into your card reader to access the data file The data file can then be opened with WINDAQ Waveform Browser Software for MMC allowing analy
86. th purchase of 5B module for accurate readings To install a shunt resistor 1 Remove the clear front panel and bezel by removing the two screws Instrument Controls Indicators and Connections 29 DI 710 Series and DI 715B Series Hardware Manual 2 Pull the casing apart from the rear panel until the shunt resistor receptacles are exposed 3 Insert the shunt resistor to its receptacle by lining up the pegs and pressing it onto the circuit board firmly The shunt resistor receptacle for each channel is directly behind the slot on the 5B backplane for that channel 4 Reassemble the DI 715B Do not overtighten the front panel screws Insert pins into the holes pro vided Press resistor firmly onto the circuit board DI 5B Backplane Install Shunt Resistor for Channel 1 Here Casing Rear Panel Instrument Controls Indicators and Connections 30 DI 710 Series and DI 715B Series Hardware Manual 5 Operation PC connected Models PC based models non Stand alone are operated and controlled using WINDAQ Software To begin displaying data on your monitor make sure all wires and cables are properly connected and start WINDAQ Acquisition by pressing the Start WINDAQ button in the Dataq Instruments Hardware Manager see Dataq Instruments Hardware Man ager on page 18 After data is recorded use WINDAQ Waveform Browser to review your data Consult the context sensitive help files or your Fast Start WIN
87. the Save As command in the File menu to save data to another format in order to perform Advanced CODAS calculations File gt Save As gt option 8 CALC is still available Converting data from a wdc format to a wdq format is also possible with File gt Save As Choose option 2 Binary with CODAS header and enter a file name with wdq as the extension For more information regarding the Save As function consult your WINDAQ Waveform Browser Help File A stand alone data file acquired with remote events or storage enabled displays an hourglass when opening while it scans for event marks and timestamps in order to construct an Event Marker table Use File Save or the Save AII button when changing files or exiting to write the Event Marker table to the file and avoid a delay when the file is opened again Operation 37 DI 710 Series and DI 715B Series Hardware Manual 6 Block Diagram DI 710 Models Dual Removable 16 Position Screw Terminals gt 1 2 4 8 OR 1 10 100 1000 Analog MUX In o o o o c Control Data Digital VO 2 Status Sample ae Buffer Microcontroller 2 Control Interface SD I Code Code Common I USB or Ethernet Interface Isolation V Power Power Suppl 4 9 36 VDC ppy 2 watts max Stand Alone Models Only Block Diagram 39 DI 710 Series and DI 715B Series Hardware Manual DI 715B Models Auto Zero Ly id Status
88. the WINDAQ program group called Dataq Instruments Hardware Manager Access WINDAQ Acquisition software Upload data from your memory card check the Status of your memory card Format your memory card configure a Stand alone data acquisition session setup the Digital I O and more in this easy to use point and click environment View the Help files by clicking on View Help in the Help menu or by pressing F1 Help All WINDAQ software utilizes context sensitive help Help may be accessed through the Help menu or by pressing the Fl key with any feature selected This will take you directly to the Help topic most relevant to that particular function or feature Help topics discuss in detail each function available in the software Introduction 3 DI 710 Series and DI 715B Series Hardware Manual 2 Specifications Unless otherwise noted specifications are for all DI 710 and all DI 715B instruments Analog Inputs Number of Channels Channel Configuration Input Impedance single ended Input Impedance differential Input bias current Input offset voltage Input offset current Maximum normal mode voltage DI 710 Maximum common mode voltage Common mode rejection DI 710 Channel to Channel crosstalk rejection Gain temperature coefficient Offset temperature coefficient Digital Filtering DI 710 16 DI 715B 8 configured for signal conditioned inputs and 8 direct con nections DI 710 16 single ended 8 d
89. tion Manager runs A Windows Security Alert may pop up asking if you would like to Block the software from installation Windows Security Alert ES N To help protect your computer Windows Firewall has blocked some features of this program Do you want to keep blocking this program Bi Mame InstallManager Publisher Dataq Instruments Inc Keep Blocking Unblock Ask Me Later Windows Firewall has blocked this program from accepting connections from the Internet or a network If vou recognize the program or trust the publisher you can unblock it When should unblock a program Click the Unblock button to continue with installation The DATAQ Installation Manager shows all DI 148 DI 158 DI 710 and DI 715B devices currently connected via USB or Ethernet to your PC Remote Ethernet models not connected to your PC or Network may require a Installation 17 DI 710 Series and DI 715B Series Hardware Manual further step for installation Add IP Click on the Help button for a description of all the functions in the instal lation software DATAQ Instruments Installation Allow 15 seconds for devices to appear Description Model Type SerialH IP Address Port 41FSEBAb DI 148 U USB 41F8EBAB N A N A 41272243 DI 158 UP USB 41272243 N A N A 41F691D0 DI 710 ELS Ethernet 41F691D0 192 168 0 17 10001 OK Add IP Remove IP Help Cancel 13 When all desired devices are showing up in the list click on the OK button t
90. tion is an extra cost option allowing you to record data at the speed of your data acquisition system When you install the software a trial version of WINDAQ High Speed is automatically installed allowing you to run the software for a limited time Activa tion is required for continued use to ensure compliance with the Software License Agreement This software is accessed through the Dataq Instruments Hardware Manager which can be found in the Start menu under the WINDAQ program group called Dataq Instruments Hardware Manager WINDAQ Waveform Browser playback software also known as WWB offers an easy way to review and analyze acquired waveforms A built in data file translator allows the user to display multiple waveforms acquired by WINDAQ Acquisition software or any of a wide range of data acquisition packages The software s disk streaming design allows data files of any length to be graphically displayed rapidly in normal or reverse time directions Seven standard cursor based measurements frequency domain and statistical analysis functions help simplify waveform analysis and interpretation WINDAQ Waveform Browser is free and installed when installing WINDAQ Software The DATAQ Instruments Hardware Manager The DATAQ Instruments Hardware Manager allows you to effectively manage and run multiple instruments installed and connected to your PC or your Network or even over the internet This software can be found in the Start menu under
91. to 5V 5 1Vdc 8mA DI 5B45 07 0 to 50kHz Oto 5V 5 1Vdc E 8mA DI 5B45 08 0 to 100kHz 0 to 5V 5 1Vdc E 8mA Accessories DI 710 Series and DI 715B Series Hardware Manual DI 5B47 Linearized Thermocouple Input Modules Each DI 5B47 thermocouple input module provides a single channel of thermocouple input which is filtered iso lated amplified linearized and converted to a high level analog voltage output see block diagram This voltage out put is logic switch controlled which allows these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 The DI 5B47 can interface to eight industry standard thermocouple types J K T E R S N and B Its correspond ing output signal operates over a 0 to 5V range Each module is cold junction compensated to correct for parasitic thermocouples formed by the thermocouple wire and screw terminals on the mounting hardware Upscale open ther mocouple detect is provided by an internal pull up resistor Downscale indication can be implemented by installing an external
92. tween the ground terminal of your data acquisition device and Signal of the device under test This measurement should be at or very near 0 Volts c Measure the voltage both the AC and DC range between the ground terminal of your data acquisition device and Common of the device under test This measurement should be at or very near O Volts 5 Should ANY of these measurements exceed their recommendation DO NOT CONNECT SIGNALS to the data acquisition device A common mode voltage may exist that could destroy the instrument You MUST determine the source of the CMV and eliminate it before taking any measurements Digital Voltmeter Device gt Ground Under i inilio Test Data Acquisition Te PC Device Measured signal is not to exceed the Full Scale Range of your data acquisition device 2Measured signal must be at or very near 0 volts 3Measured signal must be at or very near 0 volts Connect to AGnd Analog Ground port on DI 710 instruments DI 710 Series and DI 715B Series Hardware Manual Table of Contents Warranty and Service Policy ies sessies eende eo er io ea cvsctcsonssosccvsssedensstevensdsnsccosteseaacseseesssesscessesccsssedeseteds iii CAUTI N ME N v iP alle eem Tm 1 Features MEI 1 Analog Inputs EE 222 EE ees ea eB A as A ee de 2 Digital Input and Output nie entere act eee te dee ints a aa 2 SOM WANG EER EE 3 WinDag Recording and Playback Software esse ess
93. ub non powered USB hubs may not have sufficient power to run the instrument 3 The addition of this new piece of hardware will be sensed by Windows and the Found New Hardware Wiz ard will automatically be launched anticipating the installation of a device driver for the new hardware If the Wizard asks Can Windows connect to Windows Update to search for software select No not this time and click on the Next button 4 Insert The WINDAQ Resource CD ROM into your CD ROM drive It contains the device drivers for the DI 710 and DI 715B If your Windows auto play feature is enabled the WINDAQ Software Installation will start Click on the Exit button to leave the installation 5 Click through the defaults When completed the Found New Hardware Wizard will run again and again you should click through the defaults until you exit the Wizard The DI 710 and DI 715B USB models require two drivers to be installed a Serial Port and a USB driver This will look like two instruments are installed when there is only one Installation 9 DI 710 Series and DI 715B Series Hardware Manual Note If you receive the Microsoft issued warning that the software has not passed Windows Logo testing click Continue Anyway to continue with installation You will see this warning twice once for each driver USB and Serial Port Hardware Installation N The software you are installing for this hardware DATAQ DI has n
94. urrently displayed feature You must run the software with the device properly installed and connected to your PC Operation To use your instrument as a stand alone data logger follow these steps 1 Configure the Instrument using the Set Up software or by re setting to the default See The Stand alone Set Up Panel above 2 Connect signal leads See 4 Instrument Controls Indicators and Connections on page 21 3 Apply Power to the instrument using the supplied Power Cable Operation 34 DI 710 Series and DI 715B Series Hardware Manual Insert the MultiMedia Card MMC or Secure Digital Card SD into the Removable Storage Slot If the memory card has not been used with your instrument format the memory card to begin recording data See Formatting the Memory Card on page 28 To Record Data to memory card Press and hold the Control Button until the LED light turns off release the Con trol button to initiate the recording session initialization could last up to 30 seconds depending on memory card used For Ethernet models you may also use the Start Recording to SD Memory command in the DATAQ Instru ments Hardware Manager This creates a new file numbered sequentially on the memory card See also Start Recording on page 28 To Stop Recording Data to memory card Press and hold the Control Button until the LED light turns off release the Control button to end the recording session and close the data
95. ut channels 1 through 16 and the eight dig ital bits Use the sticker located on the top of your instrument for quick reference to terminal access port designations Designations are explained in full detail here Front Panel DI 710 5 DATAQ INSTRUMENTS These two ports These two ports are designated are Reserved Digital Grounds Analog Channels 4 5 o 13 x The 8 digital bits may be accessed These two ports These two 16 Analog Channel ports 8 differential for analog input through these ports Each port is are designated ports are The top row of channels 1 8 are designated positive programmable as Digital In or Digital 5V Power designated differential and the bottom row of channels 9 16 are their Out Use Digital port 0 for Remote Max Current Analog negative counterparts Start Stop and Digital port 1 for 100mA Grounds Remote Event Markers DI 710 Series instruments can accept 16 analog inputs in single ended configuration or 8 analog inputs in differential configuration Single ended inputs are configured by connecting one signal lead to the desired channel and the other signal lead to analog ground AG Be sure to read CAUTION on page v before connecting input signals Signal Ground Signal Digital Input Output DGnd 5V R Analog Channels 1 e 5 Channel 1 configured for single ended input Instrument Controls Indicators and Con
96. voltage input module provides a single channel of analog input which is amplified isolated and converted to a high level analog voltage output see block diagram This voltage output is logic switch controlled allowing these modules to share a common analog bus without the requirement of external multiplexers The DI 5B modules are designed with a completely isolated computer side circuit which can be floated to 50V from Power Common pin 16 This complete isolation means that no connection is required between I O Common and Power Common for proper operation of the output switch If desired the output switch can be turned on continuously by simply connecting pin 22 the Read Enable pin to I O Common pin 19 The input signal is processed through a preamplifier on the field side of the isolation barrier This preamplifier has a gain bandwidth product of 5MHz and is bandwidth limited to 10kHz After amplification the input signal is chopped by a proprietary chopper circuit Isolation is provided by transformer coupling again using a proprietary technique to suppress transmission of common mode spikes or surges The module is powered from 5 VDC 45 A special input circuit on the DI 5B40 and DI 5B41 modules provides protection against accidental connection of power line voltages up to 240VAC Isolation Barrier excl o Anti Aliasing i TOR ES i 1 Isochopper 4 ar Amplifier u In Pat Pending 5
Download Pdf Manuals
Related Search
Related Contents
Omnimount 30.0 WA User's Manual A4 対応 型裁断機取扱説明書 工事事務監査結果報告書(PDFデータ:176K) guide de l`avant thèse de l`école doctorale sicma USER`S MANUAL ELECTRIC TRICYCLE E-132 Spirit XE295 User's Manual MAS-1B User`s Manual - English - 3.0B Franke FCT 300 AS BD L A++ User Guide - Nightingale Care Beds Ltd PDFファイル Copyright © All rights reserved.