Home

Scanning Mode Setting

image

Contents

1. Appendix 6 ASCII Table Table 3 Function Keys H P S2 keyboard USB RS 232 L 0 1 0 1 0 Null NUL DLE 1 Up Fl SOH DCI 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right F4 EOT DC4 5 PgUp F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Table 4 Chars H 2 3 4 5 6 7 0 5 0 1 1 Q a q 2 i 2 B R b r 3 3 C S 5 4 4 D T d t 5 5 E U e u 6 amp 6 F V f 7 7 w g w 8 8 H X h 9 9 I Y i y A J Z j 7 B K k C lt L D M m E gt N n F O o DEL Example ASCII 21 74 USER MANUAL Appendix 10 Parameter bar code 0 2 IIIIIIIIIIII 4 6 IIIIIIIIIIIII 8 1 3 5 7 9 B lli D TEE A C E r Finish Setting 75
2. Transmit MSI Plessey Check Digit Do Not Transmit MSI Plessey Check Digit MSI Plessey Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 4 58 USER MANUAL Code ID setting Scan Code ID 2 Digits 00 66 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 59 WIRE LESS BAR CODE SCANNER UK Plessey Check digit verification The UK Plessey has two optional check digits The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Enable Disable UK Plessey Enable Disable UK Plessey Check Digit Verification Enable Disable UK Plessey Check Digit Transmission Transmit UK Plessey Check Digit Do Not Transmit UK Plessey Check Digit UK Plessy Lenght Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting u Scan Code ID 2 Digits 00 FF 755 60 USER MANUAL Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 61 WIRE LESS BAR CODE
3. NI NNI 43 MOG usus 46 Int rl aved BAL NAA 48 Industrial 2 OF 50 Matrix 2 OF 5 voiadadeevescdededadecucedcdcdcdedaducecscxdcdedcacdavescudcdcdadadsevess d lt dcducaudeuscdedsdcdacauuevececdedccaadudeescdcdcdedecsuvecdedcdcdededuveseedes 52 Colapap S u su 54 innu 56 MIS p 58 UKP ESSE e H 60 GS1 DataBar GS1 DataBar Truncated 62 GSP DataB r Limmel 63 WIRE LESS BAR CODE SCANNER 551 DataBar Expanded saaan 64 Advanced Bar Code Data Formatting nennen nennen nennen hinten nnn n nnn nennen nne nnne erre 66 ludo dT 66 E 66 Preamble 67 ce 67 Code 67 Code ID poshin 67 Code transmission 68 Code length transmission iii err rer rere err ere err ere err ere rere eee ere er 68 COMV AA 68 Insert Str
4. 54 USER MANUAL Start End transmission Enable Disable Codarbar Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting k Scan Code ID 2 Digits 00 FF 6 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 55 WIRE LESS BAR CODE SCANNER Code 11 Enable Disable Code 11 Enable Disable Code 11 Check Digit Verification 47248157 Enable24 Js 03 Disable 248 Code 11 Check Digit Transmission Transmit 11 Check Digit Do Not Transmit Code11 Check Digit Code 11 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 4 56 USER MANUAL Code ID setting m Scan Code ID 2 Digits 00 FF 6D M Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 57 WIRE LESS BAR CODE SCANNER MSI Plessey Enable Disable MSI Plessey Enable 0 Disable MSI Plessey Check Digit Verification Enable digit Mod10 Enable 2 digit Mod10 10 Enable 2 digit Mod11 10 Disable MSI Plessey Check Digit Transmission
5. 17 WIRE LESS BAR CODE SCANNER USB CAPS Lock Override Enable Disable USB Ignore Unknown Characters Enable Disable Emulate Keypad Enable this to send all characters as ASCII sequences over the numeric keypad For example ASCII A transmits as Enable ALT make 0 6 5 ALT Break Disable Simulated Caps Lock Enable this to invert the upper and lower case characters on the scanned bar code as if the Caps Lock state is enabled on the keyboard This inversion occurs regardless of the keyboard s Caps Lock state Enable Disable USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device When enabled this allows replacing any FN 1 characters in an EAN 128 bar code with a Key Category and value chosen by the user Enable 18 USER MANUAL Disable 19 WIRE LESS BAR CODE SCANNER RS 232 Interface Baud Rate 2400 4800 96005 19200 38400 57600 Handshaking None Scan the bar code below if no Hardware Handshaking is desired None Default Standard RTS CTS Scan the bar code below to select Standard RTS CTS Hardware Handshaking Standard RTS CTS RTS CTS Option 1 When RTS CTS Option 1 is selected the scanner asserts RTS before transmitting and ignores the state of CTS The scanner de asserts RTS when the transmi
6. if the ID of the scanner is 15 and the output barcode data will be 101512345 NOTE The ID of a scanner can be set manually or assigned by the host automatically Every scanner work with the same Host can t be with the same ID Enable Add Scanner ID as Prefix 28 USER MANUAL Disable Add Scanner ID as Prefix Power off Interval Power Off Interval 2 Digits 00 99seconds 15seconds 4 Shut down the Scanner Immediately RF operating mode NO Store Mode Do not batch data The scanner attempts to transmit every scanned barcode If the transmission is failed the barcode data is ignored and issued a beep beep beep sound Auto store Mode The scanner starts storing barcode data when it loses its connection to a host for example when a user holding the scanner walks out of range Data transmission is triggered by reestablishing the connection with hsot for example when a user holding the scanner walks back into range Manual Transmission Mode Data transmission is triggered by scanning Start transfer Bar Code Data Auto Store Mode NO Store Mode Manual Transmission Mode Start transfer Bar Code Data for Manual Transmission Mode Wire Less Communication Inter character delay Scan Wire Less Communication Inter character delay 2 Digits 0 0 9 9seconds 0 5seconds
7. 1 Scan the Function Setting Barcode The Scanner will issue a beep sound and the Red LED is on until the program is finished Scan the parameters bar code The parameters may be one or more than one digits Scan the setting barcode Finish Setting If it is programmed successful the scanner will issue a beep beep sound but issue a beep beep beep sound when fails e g Set min code length of Code 128 to 5 chars 1 Open the manual and turn chapter code128 Scan the setting bar code Scan Min Code Length Scan Min Code Length 2 Digits 00 99 1 USER MANUAL 2 Turn to the last page of this Manual Appendix 10 Parameter bar code scan the parameter bar code 0 and 5 0 UIT 5 Finish Setting 3 Scan Finish Setting finish the setting WIRE LESS BAR CODE SCANNER Set Defaults And Information Display Set Factory Defaults If you wish to return the scanner and the host to the entire factory default settings radio communication setting is not included scan the barcode Set Defaults Set Defaults If you wish to display the firmware version or Serial number of the scanner scan the barcode below Products Information Display Scanner Information Display Scanner Serial number Display If you wish to display the firmware version or Serial number of the Host scan the barcode below Host Information Displa
8. 29 WIRE LESS BAR CODE SCANNER 30 USER MANUAL EAN 13 and ISBN ISSN Enable Disable EAN 13 Enable EAN 13 0 Disable EAN 13 EAN 13 Check Digit Verification Enable EAN 13 Check Digit Verification Disable EAN 13 Check Digit Verification EAN 13 Check Digit Transmission Transmit EAN 13 Check Digit Do Not Transmit EAN 13 Check Digit Supplement Digits 2 Digits 5 Digits 2 Digits or 5 Digits None ISBN ISSN Conversion 31 WIRE LESS BAR CODE SCANNER Convert EAN 13 to ISBN ISSN Do Not Convert EAN 13 to ISBN ISSN Code ID setting Code ID is a one or two character string used to represent the symbol upon a succeeding reading If you want application to transmit Code ID you must set Code ID transmission to be enabled Refer to the chapter of Scan Code ID 2Bit 00 FF 65 C Insert String 1 Selection Scan one digits parameter 0 6 that 0 no string insert to the barcode 1 6 insert to the barcode G1 G6 to the barcode Scan Insert String 1 CIBit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 32 USER MANUAL EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 EAN 8 Check Digit Verification Enable EAN 8 Check Digit Verification Disable EAN 8 Check Digit Verification EAN 8 Check Digit Transmission Transmit E
9. Transmit Proprietary ID Transmit AIM ID Do Not Transmit Code ID Code ID position Before code data After code data 67 WIRE LESS BAR CODE SCANNER Code name transmission Transmit Code name Do Not Transmit Code name Code length transmission Transmit Code length Do Not Transmit Code length Case conversion The characters within code data or the whole output string can be set in either upper case or lower case Disable Upper data only Lower data only Upper whole string Lower whole string Insert String G1 Setting Scan Inert String GI 0 16 Chars 2 Digits Char 00 FF 004 Scan the Position of GI 2 Digits 00 99 005 68 USER MANUAL Insert String G2 Setting Scan Inert String G2 0 16 Chars 2 Digits Char 00 FF 00 Scan the Position of G2 2 Digits 00 99 004 Insert String G3 Setting G3 is also used as the string to be replaced when the replace function is enabled Scan Inert String G3 0 16 Chars 2 Digits Char 00 FF 004 Scan the Position of G3 2 Digits 00 99 004 Insert String G4 Setting G4 is also used as the string to replace G3 in a bar code data when the replace function is enabled Scan Inert String G4 0 16 Chars
10. 2 Digits Char 00 FF 004 Scan the Position of G4 2 Digits 00 99 00 FN1 substitution string setting The character Ox1D in an UCC EAN128 barcode or a Code 128 barcode or a 651 DataBar barcode can be Enable FN1 Substitution substituted with a defined string Disable FN1 Substitution Scan substitution string setting 0 4 Chars 2 Digits Char 00 FF 00 Truncate leading G5 String setting By setting G5 a defined leading character or string can be truncated G5 can also be set to be repeated Scan G5 String 0 16 Chars 2 Digits 00 FF 00 69 WIRE LESS BAR CODE SCANNER Truncate leading G5 string setting 2 Digits 00 99 01 Truncate ending G6 string setting By setting G6 a defined ending character or string can be truncated G5 can also be set to be repeated Scan G6 String 0 16 Chars 2 Digits 00 FF 00 Scan Repeat of a G6 String 2 Digits 00 99 01 Replace String Setting Replace G3 string to G4 string in barcode data Enable Disable 70 USER MANUAL Test Bar Code Ticode2010 00012345000 1234567890 8765 4325 WIRE LESS BAR CODE SCANNER Appendix 2 Default setting for eac
11. 25 WIRE LESS BAR CODE SCANNER Decode UPC EAN Only With Supplementals Enable Disable USER MANUAL Indication Volume of beeper High Middle Low Mute O Beep tone High Tone Middle Tone Low Tone 27 WIRE LESS BAR CODE SCANNER Wire Less Communication Setting Unpair the scanner from host Unpair the scanner from host Pair Scanner with Host Pairing is the process by which a scanner initiates communication with a host The scanner with the Host pairing as follows 1 Connect the scanner to the Host with the Charging Cable 2 Press the Pairing Button until the Scanner issued a beep beep sound NOTE A host is able to work with as more as 99 scanners at the same time Clear the Buffer of Scanner Scan the setting bar code below will clear the bar code data save in the scanner buffer Clear the Buffer of Scanner Wire Less Channel When there are more than one host work in the same Space every host has to work in different channel Channel is set as follows 1 Open a Notepad or other text editor 2 Press the Channel Settings button to change the channel of a host and the channel NO will be displayed in the screen Scanner ID Set the Scanner ID 2 Digits 00 99 00 Add Scanner ID as Prefix If this item is enabled the scanner will add its ID as prefix of every barcode E g When scan the bar code 12345
12. SCANNER GS1 DataBar GS1 DataBar Truncated GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format except its height is reduced to a 13 modules minimum while GS1 DataBar should have a height greaterthan or equal to 33 modules Enable Disable GS1 DataBar Enable Disable Conversion Convert GS1 DataBar to UCC EAN 128 Convert GS1 DataBar to UPC A or EAN 13 Disable Conversion Code ID setting r Scan Code ID 2 Digits 00 FF 724 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 62 USER MANUAL GS1 DataBar Limited Enable Disable GS1 DataBar Limited Enable Disable Conversion Convert GS1 DataBar Limited UCC EAN 128 Convert GS1 DataBar Limited 13 Disable Conversion Code ID setting 587 Scan Code ID 2 Digits 00 73 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 63 WIRE LESS BAR CODE SCANNER GS1 DataBar Expanded Enable Disable GS1 DataBar Expanded Enable Disable Conversion Convert GS1 DataBar Expanded UCC E
13. Scanning Mode Click Scanning Mode When the button is click the scanner will keep scanning the barcode until the barcode is Click Scanning Mode Continuous Scanning mode the scan engine is always scanning and decoding The module will read the reader or the Stand by duration elapsed barcode which gets into the scanning area automatically Only when the barcode that has been read gets out of the scanning area the module can read the next barcode Select Continuous Scanning mode Auto Continue mode The scanner will start continuous scan Automatically if any object enter the scan area When there is no bar code is read for half a minute the scanner shutdown the laser line and exit continuous scanning mode Auto Continue mode 12 USER MANUAL Keyboard wedge Keyboard type AT PS 2 Other Reserved Keyboard layout USA Italian French Turkish F Turkish Q Clock period According to the PS2 protocol the clock is provided by the device e g keyboard or scanner with the period between 60us to 200us 100 uS 200 uS 60 us 80 uS 13 WIRE LESS BAR CODE SCANNER Delay after compound key In some rare occasions machine with low speed PS2 communication portwould require a free time gap following the press release of the compound key Shift Ctrl or Alt 0 mS 10 mS 20
14. Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 47 WIRE LESS BAR CODE SCANNER Interleaved 2 of 5 Interleaved 2 of 52 of 5 Data digits Variable eCheck digit one bit optional Enable Disable Format of Interleaved Enable Disable Interleaved 2 of 5 Check Digit Verification Enable Disable Interleaved 2 of 5 Check Digit Transmission Transmit Interleaved 2 of 5 Check Digit Do Not Transmit Interleaved 2 of 5 Check Digit Interleaved 2 of 5 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 48 USER MANUAL Code ID setting i Scan Code ID 2 Digits 00 69 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 49 WIRE LESS BAR CODE SCANNER Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Disable Industrial 2 of 5 Check Digit Verification Enable Disable Industrial 2 of 5 Check Digit Transmission Transmit Industrial 2 of 5 Check Digit Do Not Transmit Industrial 2 of 5 Check Digit Industrial 2 of 5 Length Scan Max Code Length 2 Digits 00 9
15. mS 40 mS 80 mS Numeric key Alphabetic key Numeric keypad Alt keypad Power on simulation All of the PCs check the keyboard status during power on self test It simulates keyboard timing and passes keyboard present status to the PC during power on Enable Disable Inter character delay This delay is inserted after each data character transmitted 0 mS 14 USER MANUAL 5 5 10 mS 20 mS 40 mS 80 mS Inter byte delay This delay is inserted after each byte transmitted Normally a character is comprised of three or above bytes 1 mS 2mS 4 mS 8 mS Caps Lock reversion By setting enable the status of Caps Lock key i e being pressed ON or OFF on the keyboard is simulated in a reversion status Enable Caps Lock Disable Caps Lock Caps Lock override 15 WIRE LESS BAR CODE SCANNER If this function is enabled on AT or AT notebook hosts the keyboard ignores the state of the Caps Lock key Therefore an A in the bar code is sent as an A no matter what the state of the keyboard s Caps Lock key Enable Disable 16 USER MANUAL USB interface USB device type HID Keyboard Virtual RS232 Port reserved IBM Table Top USB IBM Hand Held USB USB OPOS Hand Held USB Keyboard layout USA German French Other USB Keystroke Delay No Delay 20mS 40mS
16. 9 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting j Scan Code ID 2 Digits 00 FF 6A 50 USER MANUAL Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 51 WIRE LESS BAR CODE SCANNER Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Disable Matrix 2 of 5 Check Digit Verification Enable Disable Matrix 2 of 5 Check Digit Transmission Transmit Matrix 2 of 5 Check Digit Do Not Transmit Matrix 2 of 5 Check Digit Matrix 2 of 5 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting x Scan Code ID 2 Digits 00 FF 785 52 USER MANUAL Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 53 WIRE LESS BAR CODE SCANNER Codabar Enable Disable Codabar Enable Disable Codabar Check Digit Verification Enable Disable Codabar Check Digit Transmission Transmit Codabar Check Digit Do Not Transmit Codabar Check Digit Start End type ABCD ABCD abcd abcd ABCD TN E abcd tn e
17. AN 128 Disable Conversion GS1 DataBar Expanded Lenght Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting p Scan Code ID 2 Digits 00 FF 70 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection 64 USER MANUAL Scan Insert String 2 1 Digit 0 6 0 65 WIRE LESS BAR CODE SCANNER Advanced Bar Code Data Formatting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Suffix Quick Setup CR L0 LF CR amp LF Prefix Transmit Prefix Do Not Transmit Prefix Scan Prefix 0 16 Chars 2 Digits Char 00 00 Suffix The default Suffix is CR Transmit Suffix Do Not Transmit Suffix Scan Suffix 0 22 Chars 2 Digits Char 00 FF 00 66 USER MANUAL Preamble Transmit Preamble Do Not Transmit Preamble Scan preamble 0 16 Chars 2 Digits Char 00 FF 00 Postamble Transmit Postamble Do Not Transmit Postamble Scan Postamble 0 16 Chars 2 Digits Char 00 00 Code ID
18. AN 8 Check Digit L Do Not Transmit EAN 8 Check Digit Supplement Digits 2 Digits 5 Digits 2 Digits or 5 Digits None Expand EAN 8 to EAN 13 Expand EAN 8 to EAN 13 33 WIRE LESS BAR CODE SCANNER Do Not Convert EAN 8 to EAN 13 Code ID setting d Scan Code ID 2 Digits 00 FF 64 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 34 USER MANUAL UPC A Enable Disable UPC A Enable UPC A 0 Disable UPC A UPC A Check Digit Verification Enable UPC A Check Digit Verification Disable UPC A Check Digit Verification UPC A Check Digit Transmission Transmit UPC A Check Digit Do Not Transmit UPC A Check Digit Supplement Digits 2 Digits 5 Digits 2 Digits or 5 Digits None 35 WIRE LESS BAR CODE SCANNER UPC A Truncation Expansion Expand UPC A to EAN 13 Truncate leading zeros None Code ID setting b Scan Code ID 2 Digits 00 FF 624 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 36 USER MANUAL UPC E Enable Disable UPC E Enabl
19. Wireless Barcode Scanner User Manual WIRE LESS BAR CODE SCANNER Notice 1 Please carefully read the User Manual before using the barcode the scanner 2 All software including firmware furnished to the user is on a licensed basis 2 The right is reserved to make changes to any software or product to improve reliability function or design 3 The material in this manual is subject to change without notice USER MANUAL Contents I 2 ui S 1 Parts ot tbe scanner and Host ui 3 Parts of the SCaBD rt iiie usu aaa 3 Panels of HOSt sm 3 4 Installation 4 6 O 7 Programming MSW tenet 8 Programming without ANAND NADAANAN NANANA Es 8 Programming with Parameter scccicscccccccscccccccscacccccscccccccscccccccscccccccscccscccscccscccscccsaccscccscccscccscccscccsaccscccsacescccseccsaeses 8 Set Defaults And Information Display t
20. arity bit is always 1 Mart Select Space parity and the parity bit is always 0 Space Inter character Delay This parameter specifies the inter character delay inserted between character transmissions OmS 5mS 25mS 50mS 75mS 99mS 23 WIRE LESS BAR CODE SCANNER Global Settings Element amendment Enable Element amendment Disable Element amendment Printable character Output only Enable Disable Decoder optimization Enable Decoder optimization Disable Decoder optimization Save Power Enable Disable Standby duration 2 second 5 second 10 second 24 USER MANUAL 20 second Double confirm Disable Double confirm 2 Times 5 Times 10 Times Same barcode delay time If a barcode has been scanned and output once successfully the laser beam must be off or moved away from the barcode beyond delay time to active scanning the same barcode When this feature is set to be OxFF then the delay time is indefinite Same barcode delay time 2 Digits 00 99 00 Global Max Min code length Global Max code length 2 Digits 00 99 99 Global Min code length 2 Digits 00 99 XX Global G1 G6 string selection Global Insert String 1 1 Digits 0 6 0 Global Insert String 2 1 Digits 0 6 0
21. ble Convert Code 39 to Code 32 Disable Convert Code 39 to Code 32 Code 32 Prefix A transmission Enable Code 32 Prefix A transmission Disable Code 32 Prefix A transmission as data character Enable Disable Code39 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting a Scan Code ID 2 Digits 00 FF 61 44 USER MANUAL Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 45 WIRE LESS BAR CODE SCANNER Code 93 Enable Disable Code 93 Enable Disable Code 93 Check Digit Verification Enable Code 93 Check Digit Verification Disable Code 93 Check Digit Verification Code 93 Check Digit Transmission Transmit Code 93 Check Digit Do Not Transmit Code 93 Check Digit Code 93 Full ASCII Conversion Enable Code 93 Full ASCII Disable Code 93 Full ASCII Code 93 Length Scan Max Code Length 2 Digits 00 99 99 46 USER MANUAL Scan Min Code Length 2 Digits 00 99 1 Code ID setting h Scan Code ID 2 Digits 00 FF 68 Insert String 1
22. e UPC E Disable UPC E UPC E Check Digit Verification Enable UPC E Check Digit Verification Disable UPC E Check Digit Verification UPC E Check Digit Transmission Transmit UPC E Check Digit Do Not Transmit UPC E Check Digit Supplement Digits 2 Digits 5 Digits 2 Digits or 5 Digits None 37 WIRE LESS BAR CODE SCANNER UPC E Truncation Expansion Truncate leading zeros Expand UPC E to EAN 13 Expand UPC E to UPC A None Code ID setting c Scan Code ID 2 Digits 00 FF 63 Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 38 USER MANUAL Code128 C Enable Disable Code128 Enable Code 128 0 Disable Code 128 Code128 Check Digit Verification Enable Code 128 Check Digit Verification Disable Code 128 Check Digit Verification Code 128 Check Digit Transmission Transmit Code 128 Check Digit Do Not Transmit Code 128 Check Digit Code128 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID Scan Code ID 2 Digits 00 FF 675 39 WIRE LESS BAR CODE SCANNER I
23. e data The host must transmit an ENQ character at least every Host Serial Response Time out to prevent transmission errors NQ E ACK NAK with This combines the two previous options For re transmissions of data due to a NAK from the host an additional ENQ is not required ACK NCK with ENQ XON XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character There are two situations for XON XOFF XOFF is received before the scanner has data to send When the scanner has data to send it waits up to Host Serial Response Time out for an XON character before transmission If the XON is not received within this time the scanner issues an error indication and discards the data XOFF is received during a transmission Data transmission then stops after sending the current byte When the scanner receives an XON character it sends the rest of the data message The scanner waits up to 30 seconds for the XON XON XOFF RTS Line State Host Low RTS Default Host High RTS amp RH 21 WIRE LESS BAR CODE SCANNER Host Serial Response Time out 2sec Default 5 sec 7 5 sec 10 sec Data Bits 7 Bit 8 Bit Default Stop Bit Select 1 Stop Bit Default 2 Stop Bit Parity None Default Odd Even 22 USER MANUAL Select Mark parity and the p
24. h barcode Table 2 Default setting for each barcode Code type Read Check digit Check digit Min code Proprietary AIM enable verification transmission length code ID EAN 13 Y Y Y 13 e Em EAN 8 Y Y 8 d Em ISBN ISSN1 V Y Y 13 e Em UPC A Y V Y 12 b Em UPC E V Y Y 8 c Em Code 128 5 1 g Cm UCC EAN 128 y 1 q Cm Code 93 Y Y 1 h Gm Code 39 Y 5 l a Am Code 11 Y 4 m Interleaved 2 of 5 6 i Industrial 2 of 5 4 j Im Matrix 2 of 5 Y 6 x China Post 11 y Codabar 5 k Em MSI Plessey 4 f Mm UK Plessey 1 u Mm GS1 DataBar 16 r Jem GS1 DataBar Truncated3 N 16 r Jem GS1 DataBar Limited 16 8 em GS1 DataBar Expanded V 1 p em PDF417 1 n Lm MicroPDF417 1 w Lm NOTE 1 The settings for ISBN ISSN and EAN 13 must be the same 2 Fixed length barcodes 3 The settings for GS1 DataBar Truncated and GS1 DataBar must be the same 72 USER MANUAL Appendix 4 Decode zone High Density series 300mm 200mm 100mm 218 Omm 100mm 3mil 200mm 5mm 50mm 10mil i4 85mm 300mm 10mm y j 150mm 25mm amp 9 oa 165mm 46mm _ 296mm Long Range series 100mm 200mm 300mm 400mm 500mm 600mm 700mm 73 WIRE LESS BAR CODE SCANNER
25. harging When the green LED keeps flashing or the Scanner shut down immediately after powered up these mean the battery of Scanner runs out and need Charging Connect the scanner to the Host with the Charging Cable to charge Scanner The green LED keeps flashing when the Scanner is charging until this operation is finished Charging USER MANUAL Scanning When the scanner is scanning ensure the scan line crosses every bar and space of the bar code RIGHT RIGHT 012345 012345 WRONG 012345 the Scan Line on the code WIRE LESS BAR CODE SCANNER Programming instruction The scanner is programmed by scanning the setting barcode in the Manual There are two kinds of Programming instructions One of them programmed with Parameter and the other one of them without Parameter Programming without Parameter When programming without parameter only one setting barcode is need to be scanned For example shut down the beeper of the scanner just scan the bar code directly When it is programmed successful the scanner issue a beep beep sound but issue a beep beep beep sounds when programmed fails Mute NOTE the factory default settings are indicated with asterisks Programming with Parameter It is need to scan more than one setting barcode to program the scanner with parameter Default parameters Range of parameters Setting Barcode Program Parameters The steps of programming are
26. ing GT Setting AA 68 Insert String G2 Setting 69 Insert String G3 Setting 222222228484484 69 G4 ARA AA i 69 50050101 string setting III 69 Truncate leading G5 String setting 69 Truncate ending string setting 70 Replace TANG NAA AA AA 70 Bar Code M 71 Appendix 2 Default setting for each barcode l u 72 Appendix 4 Decoue ZOME EE 73 Appendix G ASCH 5 Su cence 74 Appendix 10 Parameter bar code 75 USER MANUAL Parts of the scanner and Host Parts of the scanner D Exit window LED Trigger Cable interface port charging port Release hole of the cable Panels of Host 1 e 1 Host Port 2 6 4 Channel Settings 2 Power Port button 3 Reserved 5 Pairing Button 3 Charging Port 6 LED WIRE LESS BAR CODE SCANNER Introduction to installation Installation Host 1 Switch off the host 2 Refer to the below pictures connect the PC with the scanner based on different cables 3 Ensure that all connections are secure 4 Switch on the host system If installation is successful the beeper will beep and LED will light USB cable PS2 cable USER MANUAL RS232 cable WIRE LESS BAR CODE SCANNER C
27. nsert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 40 UCC EAN 128 Enable Disable UCC EAN 128 Enable Disable UCC EAN 128 Check Digit Verification Enable Disable UCC EAN 128 Check Digit Transmission Transmit UCC EAN 128 Check Digit Do Not Transmit UCC EAN 128 Check Digit UCC EAN 128 Length Scan Max Code Length 2 Digits 00 99 99 Scan Min Code Length 2 Digits 00 99 1 Code ID setting g Scan Code ID 2 Digits 00 675 WIRE LESS BAR CODE SCANNER Insert String 1 Selection Scan Insert String 1 1 Digit 0 6 0 Insert String 2 Selection Scan Insert String 2 1 Digit 0 6 0 42 USER MANUAL Code 39 Enable Disable Code 39 Enable 0 Disable Code 39 Check Digit Verification Enable Disable Code 39 Check Digit Transmission Transmit Code 39 Check Digit Do Not Transmit Code 39 Check Digit Code 39 Full ASCII Conversion Enable Code 39 Full ASCII Disable Code 39 Full ASCII Start End transmission Enable Code 39 Start End transmission 43 WIRE LESS BAR CODE SCANNER Disable Enable Code 39 Start End transmission Convert Code 39 to Code 32 Ena
28. onno u 10 sel Factory TG 10 Products Information Dis play eccsssncnrnrnin n n 10 Communication Information and Battery Power Display 10 11 Sewage 12 Keyboard 22222242224222422222 02124222 13 USB 17 RS 232 XR RR RENE RR RR RENE RR RR RR RR RR RR RR RR RR RR RR RR RR RR RR RR RR RR REA 20 Global 24 MSNA CATION c 27 Wire Less Communication 1 aer d a E ER HERE ER EE ER EAE EE ER RR ER RR ER RR RR RR RR RR RR RR RR RR RR RR RR RR RR RR 06 RR RR RR A 28 EAN 13 and ISBN ISSN e 31 BAN E EE 33 35 181 105 37 128 o 39
29. ssion is complete RTS CTS Option 1 RTS CTS Option 2 When Option 2 is selected RTS is always high or low user programmed logic level However the scanner waits for CTS to be asserted before transmitting data If CTS is not asserted within Host Serial Response Time out the scanner issues an error indication and discards the data RTS CTS Option 2 20 USER MANUAL RTS CTS Option 3 When Option 3 is selected the scanner asserts RTS prior to any data transmission regardless of the state of CTS The scanner waits up to Host Serial Response Time out for CTS to be asserted If CTS is not asserted during this time the scanner issues an error indication and discards the data The scanner de asserts RTS when transmission is complete RTS CTS Option 3 ACK NAK When this option is selected after transmitting data the scanner expects either an ACK or NAK response from the host When a NAK is received the scanner transmits the same data again and waits for either an ACK or NAK After three unsuccessful attempts to send data when NAKs are received the scanner issues an error indication and discards the data ACK NCK ENQ When this option is selected the scanner waits for an ENQ character from the host before transmitting data If an ENQ is not received within the Host Serial Response Time out the scanner issues an error indication and discards th
30. y Host Serial number Display Communication Information and Battery Power Display Battery Power Display Communication Channel and ID Number or Scanner Display 10 USER MANUAL Interface selection This scanner supports interfaces such as keyboard wedge RS 232 serial wedge and USB interface Typically host is able to identify the host port type automatically In extreme cases host port may need setting manually if the host fails to identify it Automatic Identification USB PS 2 Key Board RS232 11 WIRE LESS BAR CODE SCANNER Scanning Mode Setting Good read off scanning Mode The trigger button must be pressed once to activate scanning The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand by duration elapsed Select Good read off scanning Mode Auto detection scanning Mode The scanner will start scan Automatically if any object enter the scan area The laser light of scanner stops scanning when there is a successful reading or no code is decoded after the Stand by duration elapsed Once the laser light stops scanning the present object must be remove away from the scan area to enable Auto detect sensor Select Auto detection scan Press Scanning Mode It can continue scan barcode when the button is continuing pressed Press