Home
NS-105 User`s Manual
Contents
1. devices B Full duplex or half duplex operation Self learning for active MAC addresses Store and forward switching to ensure only good packets are forwarded Forwarding and filtering at full wire speed Supports IEEE 802 3x flow control for full duplex operation Supports back pressure flow control for half duplex operation Comprehensive LED indicators provide quick easy to read port and switch information USUS NS 108 Ver 1 1 May 2005 5 1 2 NS 105 Specifications Port 1 4 Port 5 Cables LED indicators Filtering rate Forwarding rate Filtering address RAM buffers Environment Dimensions Power Requirement Power Consumption IOBASE T 100BASE TX connectivity One MDI X RJ 45 jack IOBASE T 100BASE TX connectivity One MDI X RJ 45 MDI RJ 45 jack by Push Button setting IOBASE T Cat 3 4 5 UTP cable 100meters max 100BASE TX Cat 5 UTP cable 100meters max Power status Link Activity Speed Duplex Collision status per port 14 880pps for Ethernet 100BASE T 148 800pps for Fast Ethernet 100BASE TX 14 880pps for Ethernet 1KOBASE T 148 800pps for Fast Ethernet 100BASE TX Multicast Broadcast Unicast address 8K MAC address per unit 256KB Temperature 0 C to 60 C Relative humidity 10 to 90 non condensing 70mm x 160mm x 120mm 10 30 VDC 0 08A 24Vdc 5 arrowed Ver 1 1 May 2005 6 NS 108 Specifications Port 1 8 Cables
2. 05 11 10BASE T or 10 100BASE TX network cad UTP 1 or 5 UTP 100 meter max L7188EX afl Cut 5 UTP 100 meters max le controller with 10BASE T or 100BASE TX Ethernet port NS 108 Ver 1 1 May 2005 12 3 4 switched ports are designed as auto negotiation capable switched ports Each port can determine the speed and duplex type used automatically through an auto negotiation process with the remote connected auto negotiation device The auto negotiation process is performed when the connection is made When connecting to a non auto negotiation device each TP port also features the capability to auto sense the connection speed The following table lists the operation mode used for the switched port when it connects to different devices The operating mode includes the connection speed and duplex type Connected Device Operation Mode Used IOBASE T hub 10Mbps half duplex 100 hub 100Mbps half duplex Auto negotiation device Auto negotiation Non auto half duplex Auto speed sensing device half duplex Non auto full duplex device Not supported Non auto non auto negotiation 2 determined through auto negotiation process 3 speed is determined by auto sensing function Most of IOBASE T hubs and 100BASE TX hubs are non auto negotiation devices and operate on half duplex mode Ver 1 1 May 2005 13 4 LED Indic
3. LED indicators Filtering rate Forwarding rate Filtering address RAM buffers Environment Dimensions Power Requirement Power Consumption IOBASE T 100BASE TX connectivity One MDI X RJ 45 MDI RJ 45 jack IOBASE T Cat 3 4 5 UTP cable 100meters max 100 Cat 5 UTP cable 100meters max Power status 10 100Link Activity Speed Duplex Collision status per port 14 880pps for Ethernet 100BASE T 148 800pps for Fast Ethernet 100BASE TX 14 880pps for Ethernet 1OBASE T 148 800pps for Fast Ethernet 100BASE TX Multicast Broadcast Unicast address 1K MAC address per unit 64KB Temperature 0 C to 60 C Relative humidity 10 to 90 non condensing 70mm x 160mm x 120mm 10 30 VDC 0 24A 24Vdc 5 arrowed Ver 1 1 May 2005 7 2 Installing the Switch 2 1 Unpacking Check to see that you have everything before you start the installation Installation guide The switch unit 2 2 Checking Power Since NS 105 consume 2W power NS 108 consume 6W power make sure your power supply can meet this demand Input DC voltage range 10 30V The screw terminal of the DC power input is located on the front of the switch as shown below T m AE ZEE 33112 Front Panel NS 105 NS 108 Ver 1 1 May 2005 8 3 0 Making Network Connections 3 4 Network Switched Ports There are five eight ports on th
4. NS 105 NS 108 5 Port 8 Port Switch 10 100 Fast Ethernet Switch Installation Guide Ver 1 1 May 2005 1 1 1 1 1 2 2 1 2 2 3 3 1 3 2 3 3 3 4 4 4 1 4 2 Table of Contents TutroductionD sies ves nies RES REI phous a EORR eae bep SDEEITOdHOHS ud A E Installing the MOTT Ate INO orth amantadine Checking Making Network Connections ccccsccccssccccccccscccess Network Switched o anne OTE Cablen UT P Connections Bebe d Operating Mode ss e MUSEI LAT RR RENE LED obe avere E Vade LED Panel gsc Rt 1 1 2005 2 10 11 13 14 14 14 1 Introduction NS 105 NS 108 Industrial Switches are DIN Rail mounting and designed for industrial environments Their rugged packaging and protected circuitry keep them working under conditions that may cause office grade units to fail Industrial Ethernet applications are demanding This 5 port 8 port Fast Ethernet switch become the basic unit of the whole Ethernet network It is also the good companion of our 1 7188 and l 8000 ethernet embedded controller The NS 105 NS 108 comes with multiple ports each capable of transmitting or r
5. ators 4 1 LED Panel The NS 105 amp NS 108 switch provides comprehensive LED indicators for diagnosing and monitoring the operation of the unit as shown below power O Ox xO Q xO gt m X p NS 105 NS 108 4 2 Interpretation for LED functions Standard RJ45 female connectors are provided A standard RJ45 plug cable is all that is necessary to connect your device to the unit since switch that supports auto crossover Table 1 shows the LED indicator functions for NS 105 Table 2 shows the LED indicator functions for NS 108 ES 105 EROS 108 Power is On Power is On Power Power Power is Off Power is Off Green On Full duplex Red On Link Act Ethernet Ethernet Red Off Not Networking Red On Half duplex Port Port Green On Link to 100 Mbps Green Red Traffic Collisions Green Off Link to 10 Mbps Ver 1 1 May 2005 14
6. crossover UTP cable RJ 45 plug RJ 45 plug 1 Straight through UTP 1 2 2 3 3 6 6 RJ 45 plug RJ 45 plug 1 Crossover UTP 1 2 2 3 6 6 It is suggested to use straight through UTP cables for all UTP connections The maximum length and UTP cable categories used for the connections to a device and 100BASE TX device are CONNECTED DEVICE UTP CABLE USED amp MAXIMUM LENGTH IOBASE T device Cat 3 4 5 UTP 100meters 100BASE TX device Cat 5 UTP 100meters Ver 1 1 May 2005 10 3 3 UTP Connections The NS 105 NS 108 switch can support connections to the following devices 10BASE T network cards 10 100BASE TX network cards 10BASE T hub ports 100BASE TX hub ports 10 100BASE TX dual speed hub ports 10 100BASE TX switch ports Ethernet devices Ethernet Embedded controller such as 1 7188 1 7188 8430 1 8431 1 8830 1 8831 1 8437 1 8837 1 8438 I 8838 The following figure shows some connection examples and also specifies the maximum distance of each connections 10BASE T hub UTP cable 100 meters max MDI MDI X 10BASE T URN network card LT LN UTP cable Cat 3 1 or 5 UTP 100 meters max 1 7188EX Cat 5 UTP 100 meters max Programable controller with 10BASE T or 100BASE TX Ethernet port NS 105 Ver 1 1 May 20
7. e switch for connection to five eight LAN segments Each segment is an independent shared network in one collision domain MDI X 789 am MDI si For Port 5 Only TP Port 1 4 MDI X jacks NS 105 NS 108 Five Eight 10 100BASE TX switched ports Each port consists of one RJ 45 connector and is used for connection to either IOBASE T or 100BASE TX device The RJ 45 connectors are fixed MDI X jacks which are designed with internal crossover function It allows a connection to an end station using straight through UTP cable MODI Jack support for Port 5 for NS 105 One additional push button is provided for Port 5 to switch MDI X or MDI It is useful when using Port 5 as an uplink port and using straight through UTP cable for the connection to any device NS 105 NS 105 Pin Definition Port 1 4 Port 5 RJ 45 Push Button Setting 1 RX 2 RX v v MDI X 3 6 TX 45 758 NC 1 2 TX v MDI 3 RX N A 6 RX 4 5 7 8 Ver 1 1 2005 9 NS 108 RJ 45 Pin Definition Port 1 8 1 RX 2 RX v MDI X 3 TX 6 TX 4 5 7 8 NC 1 2 TX v MDI 3 RX 6 RX 4 5 7 8 NC 3 2 UTP Cable When making a connection to another device using straight through UTP cable make sure MDI X to MDI connection rule 15 followed The following figure illustrates the pin assignments of a straight through UTP and a
8. eceiving information simultaneously at full wire speed to control and allocate the network bandwidth Besides that the NS 105 NS 108 Industrial Ethernet Switch automatically determines and remembers where an Ethernet device is located and routes the messages only through the appropriate port This minimizes network loading and enables true deterministic communications over Ethernet Front Panel Rear Panel NS 105 Ver 1 1 May 2005 3 Front Panel Rear Panel NS 108 The key features of this switch unit are Optimized Bandwidth Combining five eight 10 100Mbps based Fast Ethernet switched ports the switch delivers a high network bandwidth for your Fast Ethernet network Easy Migration With IOBASE T support on each port the switch provides a non disruptive and smooth migration path from Ethernet to a Fast Ethernet network Installation With the functions of auto speed sensing and auto negotiation on each port the switch supports plug and play installation which eliminates configuration problems Ver 1 1 May 2005 4 11 Features IEEE 802 3 IOBASE T 2 802 100BASE TX and IEEE 802 3x flow control standards Five Eight 10 100BASE TX auto negotiation switched ports for flexible connections to desktop PCs servers and Ethernet hubs The 10 100BASE TX switched support Auto speed sensing for 100Mbps or 10Mbps connection B Auto Configuration with auto negotiation