User Manual EN V1.6
Contents
1. 4 Powering During installation your certified plumber connected the control panel of the Aqua Protec system to a 120V outlet During installation the emergency battery is also connected Solid green light figure1 indicates that the Aqua Protec is properly powered primary and emergency When the green light flashes figure2 it indicates a power failure and the compressor will be running on backup power battery and will continue to do so until the power is restored Figure 1 Figure 2 Despite the power outage the device remains fully operational for a period of one week 4 Page Rev V1 6 EN 11 08 2014 5 Battery replacement The emergency battery has an expected life of 3 4 years It can keep the system fully functional for more than a week in the event of a power outage Aqua Protec notifies you in advance when the battery no longer keeps its charge and a replacement is necessary The message REPLACEMENT REQUIRED appears on the display screen on the control panel 6 Balloon replacement Aqua Protec is a fully automated system and requires little human intervention It should protect your home at all times even in the most extreme situations In order to ensure its proper operation the RPSM has a limited recommended lifespan and must be replaced at the earliest of the following e After being deployed for a duration of more than 24 consecutive hours or e After 10 deployments of duration of more than 1 hour or e After
2. Aqua Protec will detect compressor failure slow leak and low battery This test is run without any human needs and it does NOT affect used water evacuation You can use water without any issue When test is preceded all light are turned OFF Figure 7 If Aqua Protec detects any abnormal situation it will inform you with an audible alarm sound It will display a message or an error code on the control panel screen Press the X button to mute the alarm sound Contact Aqua Protec technical support 1 877 287 7777 and we will assist you 9 Maintenance Aqua Protec is the most reliable device on the market because it is the only one that complies with IGC 283 2011 IAPMO Standard and auto test itself weekly but due to its operating environment we recommend an annual inspection by certified plumber especially if many events of sewer backup occurred It is a quick inspection that assures optimal performance of the product Contact us is you think your system need some attention 10 Precaution for your Aqua Protec To ensure optimum performance of Aqua Protec cable between control panel and the clean out must remain free at any time Do not stack any object on it Air used to inflate the balloon is circulating in the cable If the cable is pinched system may not operate properly Weekly auto test will detect and inform you if cable is pinched 8 Page Rev V1 6 EN 11 08 2014 11 Work to be done in your sewer Over ti
3. 14 11 2 Balloon insertion instructions 1 Insert the balloon into the cleanout taking care to direct probe sensors in same direction as the flow in the sewer 2 Using positioning rod slide the balloon until the anchor ring sit at the bottom of cleanout cap threads Note To ease the way down back into the cleanout silicon lubricant can be used on the balloon Do not use any other grease type Probe sensors must remain clean Make sure steel wires are going thru the anchor ring Tighten cleanout cap in place Hand tightening is enough to seal the cap Tighten cable gland to insure water tightness Hand tightening is enough to seal the cable gland 6 Repowering the system 6 1 Connect the battery terminal 6 2 Plug the power supply into the walled outlet We recommend running a full test to confirm that the system is functional If the test is not performed at this time the system will run the test during the weekly self check Sewer flow po Figure 8 10 Page Rev V1 6 EN 11 08 2014 12 Information displayed Here is a list of messages you can see on the control panel screen of Aqua Protec Messages STANDBY WATER DETECTED ALERT mode INFLATION KEEP DEFLATION SEWER FREE SEWER SEALED MANUAL CONTROL OUT OF ORDER 13 Contact Description Aqua Protec is armed Aqua Protec detects water If detection last more than 5 consecutive seconds Aqua Protec will switch in ALERT mode Sewer backup si
4. 5 years of service The control panel will inform you when the balloon requires to be replaced 7 How to navigate your Aqua Protec Your certified plumber configured your Aqua Protec You can access to the menu by pressing the CHECK y button The display will list followed options 1 LANGAUGE 1 VERSION 2 HISTORY 3 TECHNICIAN 7 1 How to change language You can modify the displayed language To select a new language 1 Press the CHECK v button 2 With up and down arrows 7 navigate until you reach LANGUAGE line 3 Use RIGHT arrow gt to select LANGUAGE menu 4 Different LANGUAGE are listed Use up and down arrows f to navigate 5 Use RIGHT arrow gt to confirm the desired LANGUAGE 6 Use LEFT arrow to return to previous menu 5 Page Rev V1 6 EN 11 08 2014 7 2 Software release You can validate on which release your Aqua Protec operates 1 Press the CHECK v button 2 With up and down arrows navigate until you reach VERSION line 3 Use RIGHT arrow gt to see software information 4 You should see release V2 0_C11 or higher 5 Use LEFT arrow to return to previous menu 7 3 Aqua Protec history Aqua Protec will protect your property from all sewer backup situations and list and record any incidents when the system is deployed in this menu It will indicate the date hour and how long the event occurred You will have the information on how many times Aqua Prot
5. User Manual INNER 2 3 A To A Y ON PROTEC MANUFACTURED BY Inflotrolix 1 Page Rev V1 6 EN 11 08 2014 2 Page Copyright Disclaimer Trademarks and patents Intended use Contact info O 2011 Inflotrolix Inc This document may not be copied in whole or in part or otherwise reproduced without prior written consent from Inflotrolix Inc except where specifically permitted under Canadian US and international copyright law The information in this document is subject to change without notice Inflotrolix Inc Inflotrolix assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest documentation contact your local supplier or visit us online at www aqua protec com This publication may contain examples of screen captures and reports used in daily operations Aqua Protec is a registered trademark and is patent pending in Canada and the United States Use this product only for the purpose it was designed for refer to the data sheet and user documentation for details For the latest product information contact your local supplier or visit us online at www aqua protec com For contact information see our Web site www aqua protec com en Rev V1 6 EN 11 08 2014 Table of Content
6. ec protected your home If nothing is listed it s means that no sewer backup occurred 2 Press the CHECK y button 3 With up and down arrows 1 navigate until you reach HISTORY line 4 Use RIGHT arrow gt to see history information 5 Use LEFT arrow to return to previous menu 7 4 Technician menu This menu is intended to be used only by the certified plumber for periodic maintenance or inspection of Aqua Protec It requires a password 8 Operation modes Once your Aqua Protec is fully installed and configured it can be in 3 different status modes STANDBY mode ALERT mode WEEKLY SELF TESTING mode 6 Page Rev V1 6 EN 11 08 2014 8 1 STANDBY mode Under normal conditions the display is showing STANDBY and solid green light is on figure3 The Aqua Protec is working properly and ready to react to protect your home from a sewer backup situation Figure 3 8 2 ALERT mode During a sewer backup situation Aqua Protec is in ALERT mode An audible alarm will be heard ALERT mode is displayed green light is OFF solid yellow light is ON water detection figure4 and solid red light is ON sewer sealed figure5 Aqua Protec will display WATER DETECTED and SEWER SEALED After a detection of 5 consecutive seconds system will switch to Alert Mode and will seal the drain Figure 4 Figure 5 Press the X button to mute the alarm s
7. me your sewer may require to be inspected unclog repaired or clean The clean out will be used to execute the work by your licensed plumber Aqua Protec can easily be removed to do the work In this situation you need to inform the plumber that an Aqua Protec is installed in the clean out If the plumber in not familiar with Aqua Protec he can refer to Balloon removal instruction in the user manual 11 1 Balloon removal instructions Attention Before beginning balloon removal make sure the system in not running its weekly auto test 1 Turn off the power 1 1 Unplug the power supply from the walled outlet 1 2 Disconnect one terminal of the battery 2 Loosen the cable gland of the cleanout cap Loosen and remove cleanout cap from the cleanout 4 Keeping the anchor ring attached carefully pull on the installation rod and the steel extraction cables until the balloon is retracted out of the clean out Lubricate with water and soap as required 5 Place the balloon on a clean surface During installation the balloon was covered with a silicone lubricant to ensure easy positioning and sealing Accumulated residue on the balloon may affect the ease to reposition of the balloon into the cleanout Once the work is completed Aqua Protec can be reinserted in the cleanout Repositioned correctly it will once more protect your basement from sewage backups See insert procedures in this manual 9 Page Rev V1 6 EN 11 08 20
8. ound CAUTION During sewer backup situation Aqua Protec seals the sewer pipe Used water can NOT be evacuated To avoid flooding do NOT use water in the house Do NOT flush ANY toilets stop using the shower Stop in progress water using appliances such as dishwashers and washing machines Note Aqua Protec can be connected to Nowa which is an automatic water shutoff valve to prevent water usage Visit www nowasystems com for more information Aqua Protec can also be linked to your home alarm monitoring system To be sure that the sewer backup situation is over and the water level is back to a safe level Aqua Protec will remain in ALERT mode for 30 minutes It is normal to see the solid red light ON and yellow light OFF figure6 Time left to free the sewer is displayed on the control panel Audible alarm will inform you when the sewer will be free Sound will last for 10 consecutive minutes and then 10 seconds per minutes until you press the X button Aqua Protec wants to make sure you are aware of the event Even if no one is home during the event you will be informed upon your return 7 Page Rev V1 6 EN 11 08 2014 Figure 6 Press the X button to mute the alarm sound 8 3 Weekly self testing mode The reliability of Aqua Protec is assured by its weekly auto testing Once a week Aqua Protec is self checking the system The control panel partially inflates the RPSM and maintains the pressure during 15 minutes
9. s Us Ma A aa On Aia iia 1 1 Introduction to Aqua ProteC cios a a A a Ea 4 2 Intent OP USC acid 4 3 HOW IE WORKS stat Be A a E daa 4 4 POWER a a demu AN EA DEE TANA 4 5 Battery replacement isinara a ao td a dhe 5 6 BalloOn FeplaCe Mi a e coddagieueekinst coc cae EE a 5 7 How to navigate your Aqua PrOteC oooccnccncnconcnncnnnnancnnanannnnranenan nn nrnnr narra rrnnr narra nannns 5 7 1 How to change lag ii a tagdaden dienes 5 Z 24 SoftWare TELASC ek sic ievinePacdee a a a E A EEE a savin tad dodea ie iTi 6 7 3 Aqua Protec SOY popisi nia A iaa 6 7 4 TECHNICIAN MONUW s oeni e a a ntact eal aaa eve uated adaa ei 6 8 Operation MOdES eea e neue av dd Gran 6 8 1 STANDBY MOG Parara aee E a E a aa tans 7 8 2 ALERT MOTE sraa aa a A E lela hank 7 8 3 Weekly Self teSting MOdC noni anA aE arn PAEAN ANAE AEE KANEA dente 8 9 Manten ANGE wii erna eA AA as 8 10 Precaution for your Aqua Prot Ciis esineen ee ee re eee ee E E Ea E 8 11 Work to be done in YOUr SQWEP ceeeeeeece eee erent eee eee ener renee nena eens es aaea 9 11 1 Balloon removal instruction a Fa iaa 9 11 2 Insert the balloon in the cleanout ssrin niaaa aana aTi Taa 10 12 Information displayed comia a a a oo 11 13 A ere vintagsdd ete waned atenteus epbecegysdnadedYeteueces eae ates ee edee eet andeddetanateleaenteds eae 11 14 Certificates and Patent iaiiia a chee ec aveauh dian A dese thea aaa veer teas 11 3 Page Rev V1 6 EN 11 08 2014 1 Introduction to Aq
10. tuation is occurring Aqua Protec inflates the RPSM RPSM is sealing the sewer Do NOT use water services Aqua Protec deflates the RPSM RPSM is retracted and sewer is free SEWER is sealed DO NOT used any water services toilet dishwasher washing machine shower etc Aqua Protec is in manual mode and will NOT detect water Technician forgot to return to automatic mode Call back the installer or technical support 1 877 287 7777 Aqua Protec faced an abnormal situation and need assistance from a certified technician Call your local supplier or our technical support 1 877 287 7777 Aqua Protec is made in Canada by Inflotrolix Inc You can contact our customer service at 1 877 287 7777 You can visit us thru our web site www aqua protec com 14 Certificates and Patent SP C US 247603 11 Page Enw Patent Pending D US2011005615A1 IGC 283 2011 Rev V1 6 EN 11 08 2014
11. ua Protec Aqua Protec is design to protect you your family and all your possessions stored in the basement Aqua Protec is an automatic electro pneumatic device to protect you against back water situation Unlike conventional mechanical valves the Aqua Protec system is completely automated and reliable It is composed of a control panel a 17 umbilical cord and a Retractable Pneumatic Sealing Module RPSM or the balloon The RPSM is equipped with sensors which in case of municipal sewer backups are triggered sending a signal to the onboard compressor to deploy the RPSM by filling it with 11 5 PSI of air pressure causing the RPSM to expand firmly into the 4 sewage drain pipe This manual gives directions on how to use your Aqua Protec 2 Intent of use Aqua Protec is a device used to minimize the risk of sewer backup in a single family residence It is fully automatic so it requires very little intervention on your part It will protect your home at all times even in the most severe situations 3 How it works In case of sewer backup sensors will detect the high level of water in just few seconds and communicate to the control panel Air will be compressed into the balloon which will seal the sewer pipe and protect your residence It will remain inflated until the retraction of water from the sewer pipe When Aqua Protec no longer detects water it will deflate and automatically return to standby mode until the next event