1. Warning when use DMX512 to control some of picture under the edit effect may result in laser safe protection panel moving but without laser projection That is the value of channel 4 or 15 is too large or the value of channel 5 or 6 is too small Only need to adjust them to a suitable value the operation will become normal The following channels are only for channel 1 value 192 255 effect selection PR 5030A stores 256 pieces of picture combination effect which have had movement parameter and divided into 16 groups Every group has 16 picture combination effect through channel 2 to choose a group and through channel 3 to choose a picture combination effect in the group Picture combination effect is different from common picture and it is designed specially and cannot be edited CHANNEL DMX VALUE DESCRIPTION 0 15 Display picture group 1 16 31 Display picture group 2 32 47 Display picture group 3 48 63 Display picture group 4 64 79 Display picture group 5 80 95 Display picture group 6 2 96 111 Display picture group 7 Display picture 112 127 Display picture group 8 group selection 128 143 Display picture group 9 144 159 Display picture group 10 160 175 Display picture group 11 176 191 Display picture group 12 192 207 Display picture group 13 208 223 Display picture group 14 224 239 Display p
2. Laser 100 manual en doc NOTICE 1 If peripherals or cable is damaged please purchase it that is PR or LASER Company provided for change 2 This software tests normally in the environment of win98 winxp and win2000 We do not provide the function guarantees if it is not under these operation systems 3 This software does not include destructive program like wood horse virus and back door and so on Please use it securely If user s system has infected virus we do not guarantee the program can use normally 4 Please keep the projector clean excessive smoke and bad exterior ambient may degrade use life of the projector and power attenuation of the lamp PR LIGHTING LTD Ernest nm Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 020 8478 1888 FAX 020 8478 6023 P N 320030071 Last Revision 15 06 2006 21 21 Laser 100 manual_en doc
3. OPERATION FOR DATA REFRESH 1 Connect the power cord and cable of data refresh with the unit and the other end of the cable of data refresh connecting with a personal computer Note The power must be cut off before this operation 2 First turn on the computer power and then the unit s power 3 Don t run the data refresh program until the red LED near the unit s screen is blinking Set the computer s interface of COM1 or COM2 according to the cable of data refresh you have connected 4 Running LASERDANCE 5 0 software refer to user manual of relative software Note During transmitting the data the power of the unit cannot be off otherwise some components inside the unit may be damaged Wait until appear the dialog box for complete transmitting and then you turn off the unit 5 After turning off the unit s power pull the data refresh cable out of the unit Connect the DMX512 cable to the unit for operation 6 The data refresh cable is made up of DB9 M and DB9 F plugs and 3 core screened cable as shown below shield R FSE DIDI Sjef 1 6 2 3 8 4 9 5 Br FEL A MAINTENANCE Because the unit is a precise device integrated with optics mechanism and electronics please pay attention to the following points when use the unit normally 1 When use a fog machine do not eject the fog to the unit directly minimum distance is 1m It is recommended to use a fan to blow strong fog away from the unit or to u
4. RELIABILITY LAZER 150G PR 5030A This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin Road Dashi Panyu Guangzhou 511430 China http www pr lighting com INDEX MAIN FEATURES 3 SAFETY WARNING 4 SAFETY PROTECTION FUNCTIONS 5 SAFE USAGE OF THE PROJECTOR 6 INSTALLING THE PROJECTOR 7 POWER SUPPLY MAINS 7 OPERATION 8 XLR CONNECTORS AND TERMINATOR 9 DMX512 CONTROL 10 DMX CONTROL CHANNEL FUNCTIONS 11 OPERATIONS FOR DATA REFRESH 17 MAINTENANCE 17 ELECTRICAL DIAGRAM 18 NOTICE 21 Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any conseguence arising from them Every apparatus is tested completely and packed properly by the manufacturer Please make sure the packing and or the apparatus is in good condition before your installation and use Should there be any damage caused by transportation consult your dealer and do not use the apparatus Any damage caused by improper use will not be assumed by the manufacturer and
5. 224 239 Picture group 15 240 255 Picture group 16 0 15 Picture 1 16 31 Picture 2 32 47 Picture 3 48 63 Picture 4 64 79 Picture 5 80 95 Picture 6 3 96 111 Picture 7 Picture 112 127 Picture 8 Selection 128 143 Picture 9 16 pieces 144 159 Picture 10 160 175 Picture 11 176 191 Picture 12 192 207 Picture 13 208 223 Picture 14 224 239 Picture 15 240 255 Picture 16 Not used 0 15 Full range1 16 ol 12 21 Laser 100 manual_en doc X Range Adjust 16 31 Full range2 16 32 47 Full range3 16 48 63 Full range4 16 64 79 Full range5 16 80 95 Full range6 16 96 111 Full range7 16 112 127 Full range8 16 128 143 Full range9 16 144 159 Full range10 16 160 175 Full range11 16 176 191 Full range12 16 192 207 Full range13 16 208 223 Full range14 16 224 239 Full range15 16 240 255 Full range 10096 6 Y Range Adjust 0 15 Full range1 16 16 31 Full range2 16 32 47 Full range3 16 48 63 Full range4 16 64 79 Full range5 16 80 95 Full range6 16 96 111 Full range7 16 112 127 Full range8 16 128 143 Full range9 16 144 159 Full range10 16 160 175 Full range11 16 176 191 Full range12 16 192 207 Full range13 16 208
6. 5031 PR 5032 PR 5033 and PR 5034 and so on according to the differences of the power consumption and colour of their light source All of the product manuals in the PR 5030A series are same except the differences of the power consumption and colour 2 21 Laser 100 manual_en doc MAIN FEATURES 10 11 12 Professional optical system dustproof technique so need not periodic clean even if long time usage Uses international standard high speed vibratile lens whose scanning speed above 30K make the scanning pattern more steady and exquisite Adopts the latest laser lamp of DPSS Uses international standard DMX 512 protocol Laser pictures picture changing method and picture movement speed can be controlled via DMX 512 controller Adopts large memory of FLASH to save the pictures The memory capacity can up to 8Mbit There are 256 built in basic pictures and characters 256 pre programmed combination picture effect up to 300 000 kinds of actual light beam effects 10 set of beautiful animation and 32 user refreshable graphics Users can convert the standard ILDA format into the laser pictures compile program and refresh the 32 user refreshable graphics inside the unit The 12 bit resolution of the laser picture makes the pictures clearer Adopts BLANKING technology to produce verisimilitude images Has multi laser safety protection function and can cut off automatically if any error occurs Has 3 sound activation demo to
7. harm Note of Safety Use 5 the safety standard in every country and area is different Please contact local laser official to Know correlative regulations before actual usage of the projector 4 21 Laser 100 manual_en doc SAFETY PROTECTION FUNCTIONS The laser safety protection measures of this product LAZER 150 PR 5030A are implemented according to the relative European items These measures are as below A the cover open protection open the plastic shell if there is current flows the laser will be cut off automatically A laser key switch the laser can be switch on when key is under on circumstance the key cannot pull out at the same time A external urgent and safe switch switch off the laser manually if error occurs A laser indication device there are laser indication devices at the side of key switch and on the socket used to indicate the laser is ready A laser safety marks there are marks on the head of the unit at several places comply with the Europe standard 104410 IOAV a NOLLVIGVY YASVT UOH ONINAdO Nvag OL HNDSOdXH N DANGER GN A LASER PAD ATI ON CALSS 3B IF COVER I S PEND AND AVO D DI RECT EXPCSLFE TO BEAM Athe laser safety protection panel if the laser beam scans in a small spot may have safety hidden trouble The panel will be closed within 25 ms co
8. 223 Full range14 16 224 239 Full range15 16 240 255 Full range 10096 7 Pan Rotation on Sixteen 0 15 Pan rotation without direction change 16 31 32 47 48 63 64 79 80 95 96 111 112 127 Normal rotation from slow to fast 128 143 Pan rotation without direction change 144 159 160 175 176 191 192 207 208 223 224 239 240 255 Reverse rotation from slow to fast 8 Tilt Rotation on Sixteen 0 15 Tilt rotation without direction change 16 31 32 47 48 63 64 79 80 95 96 111 112 127 Normal rotation from slow to fast 128 143 Tilt rotation without direction change 144 159 160 175 176 191 192 207 208 223 Reverse rotation from slow to fast 13 21 Laser 100 manual_en doc 224 239 240 255 0 15 Z rotation without direction change 16 31 32 47 48 63 64 79 Normal rotation from slow to fast 80 95 9 96 111 Z Rotation 112 127 on Sixteen 128 143 Z rotation without direction change 144 159 160 175 176 191 192 207 Reverse rotation from slow to fast 208 223 224 239 240 255 10 Z Initial Angle 0 255 Anti clockwise 2 8
9. DMX out socket PIN3 on the last unit in the chain GN N PIN2 DMX512 CONTROL Each LAZER 150 must be given a DMX start address so that the correct projector responds to the correct control signals This DMX start address is the channel number from which the projector starts to listen to the digital control information being sent out from the controller The LAZER 150 has 16 channels so set the No 1 projector s address 001 No 2 projector s address 017 No 3 projector s address 033 No 4 projector s address 049 and so on Certainly you may use formulation address channels x projector No 1 1 For example for the No 5 projector s start address you should calculate according to formulation 16 x 5 1 1 65 so you set the No 5 projector start address 065 How to set DMX start address please refer to Operation section Connect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input The rest may be deduced by analogy Eventually connect the last fixture s output to a DMX terminator as shown in the figure below g jii ac HIR 10 21 Laser 100 manual_en doc DMX CONTROL CHANNEL FUNCTIONS The LAZER 150 uses 16 DMX channels They are listed in the following table CHANNEL DMX VALUE DESCRIPTION Unit OFF 38 74 Unit ON animation 4 75 110 Unit ON geometric pict
10. achieve impact effect single projector can run under sound activation without controller TECHNICAL DATA Power supply 90 220V AC 50Hz wide voltage Power consumption 100W 220V Output power 150mW Beam length 532nm Green Interface Control DMX 512 Refresh data RS 232 Channels 16 Dimensions 411mm LONG x 261mm WIDE x 150mm HIGH Net weight 16kg 3 21 Laser 100 manual_en doc PR 5030A OUTLOOK SAFETY WARNING The LAZER 150 PR 5030A belongs to the CLASS III B laser product the laser lamp parameter is as follows Maximum output power 150 mW Beam length 532 nm green therefore Light spot size lt 1 2mm Note of Safety Use 1 because the energy of this kind of laser is strong enough to result in the permanence injury to persons eyes must avoid see the laser beam directly in use process especially the laser beam stops at aspot can cause eye burns seriously Note of Safety Use 2 inside of the projector has automatic laser safety protection circuitry However for your safety it is recommended that install the Laser urgency switch in place you can control conveniently so that you can turn off the laser manually in case of emergency Note of Safety Use 3 for your safety please do not run the projector when cover is open Note of Safety Use 4 please take off the laser key if non use in case of other people unfamiliar with the projector turn it on and then lead to
11. degrees when move 2 DMX value 0 15 Zoon in and out without change 16 31 32 47 48 63 64 79 Zoon in range from small to large 80 95 41 96 111 Zoom In and Out EEE i on Sixteen 128 143 Zoon in and out without change 144 159 160 175 176 191 192 207 Zoon out range from small to large 208 223 224 239 240 255 12 0 127 Normal movement increment increases Pan Movement on 128 128 255 Reverse movement increment decreases 13 0 127 Normal movement increment increases Tilt Movement on 128 128 255 Reverse movement increment decreases 14 0 85 Rotate and zoom in out round the figure centre Rotation Centre Write 86 171 Rotate and zoom in out round the picture centre 3 172 255 Under write circumstance 0 15 Scanning speed is 24K 16 31 Scanning speed is 23K 32 47 Scanning speed is 22K 48 63 Scanning speed is 21K 64 79 Scanning speed is 20K 80 95 Scanning speed is 19K 15 gt pe scanning speed is LEK 112 canning speed is Scanning speed 128 143 Scanning speed is 16K 144 159 Scanning speed is 15K 160 175 Scanning speed is 14K 176 191 Scanning speed is 13K 192 207 Scanning speed is 12K 208 223 Scanning speed is 11K 224 239 Scanning speed is 10K 240 255 Scanning speed is 9K 16 0 25 Strobe closed Strobe 26 51 Strobe 1 slow 52 77 Strobe 2 14 21 Laser 100 manual_en doc 78 103 Strobe 3 104 129 Strobe 4 130 155 Strobe 5 156 181 Strobe 6 182 207 Strobe 7 208 233 Strobe 8 234 255 Strobe 9 fast
12. e 12 16 192 207 Full range13 16 208 223 Full range14 16 224 239 Full range15 16 240 255 Full range 100 11 21 Laser 100 manual_en doc 0 15 Full range1 16 16 31 Full range2 16 32 47 Full range3 16 48 63 Full range4 16 64 79 Full range5 16 80 95 Full range6 16 96 111 Full range7 16 6 112 127 Full range8 16 Y Range adjust 128 143 Full range9 16 144 159 Full range10 16 160 175 Full range11 16 176 191 Full range12 16 192 207 Full range13 16 208 223 Full range14 16 224 239 Full range15 16 240 255 Full range 10096 The following channels are only for channel 1 value 128 191 geometric picture PR 5030A stores 256 static pictures that divided into 16 groups through channel 2 to choose the group number every group is made up of 16 pictures and through channel 3 to choose a picture and through other channel to edit dynamic effect such as zoom in rotate move write etc You can also edit static effect such as corner CHANNEL DMX VALUE DESCRIPTION 0 15 Picture group 1 16 31 Picture group 2 32 47 Picture group 3 48 63 Picture group 4 64 79 Picture group 5 80 95 Picture group 6 2 96 111 Picture group 7 Picture Group 112 127 Picture group 8 Selection 128 143 Picture group 9 16 groups 144 159 Picture group 10 160 175 Picture group 11 176 191 Picture group 12 192 207 Picture group 13 208 223 Picture group 14
13. e 9 PIN l 8 o ep o o o SCAN DI REV4 1A DMX QUT DMX IN NEN Q J6 J35 JOE o pg ete 2 Ja o PN l 2 Je V1 Ke Pe JL le 3 13 E J3 ZK4 0 Je 5 Je o SIE o o 5 LASER SAFE VII O 2 16s 16700 MER Tee Fe Na o mo L N El A EGG N 2 ape i 1 Jt SZ4 0 Bar re j4 T Bg ce o o e e o Her 5 o el el ll o Jean js Ei Si Hs 4 2 J3 SAFE LOCK vi2 3 Ve cr Jt e me y o Ad 10 047 mM E ey b PR 5030A shape 18 21 Laser 100 manual_en doc c PR 5030A assemblage d PR 5030A back nog Laser 100 manual_en doc 19 21 Assembly Spec Item Name Description 1 Main board ZK4 02 V1 0 2 Reed Switch amp Magnet 50V 1A 3 Safe board LASER SAFE V1 1 4 X scanner moto 5 Y scanner moto 6 X scanner serve amplifier SCAN D1 V4 1A board 7 Y scanner serve amplifier SCAN D1 V4 1A board 8 Multi outputs switching INJAC85 250V OUT regulator 24V 1A 5V 1A 9 Inter lock board SAFE LOCK V1 2 10 Laser power 11 laser 532nm 150mw 12 EMI Filter 115 250VAC 1A 13 Potentiometer 10KO O 5WU gain adjust 14 Panel socket 3 poles 15 Panel plug 3 poles 16 Key Switch 17 Laser Emergency Stop connector 18 Laser Standby Red 193 LED 19 Fan DC 24V 0 15A 20 Data Port DB9 M 21 Display board SZ4 02 V1 0 20 21
14. icture group 15 240 255 Display picture group 16 0 15 Display picture 1 16 31 Display picture 2 32 47 Display picture 3 48 63 Display picture 4 64 79 Display picture 5 80 95 Display picture 6 3 96 111 Display picture 7 Display picture 112 127 Display picture 8 selection 128 143 Display picture 9 144 159 Display picture 10 160 175 Display picture 11 176 191 Display picture 12 192 207 Display picture 13 208 223 Display picture 14 224 239 Display picture 15 240 255 Display picture 16 15 21 Laser 100 manual_en doc Not used 0 15 Full range1 16 16 31 Full range2 16 32 47 Full range3 16 48 63 Full range4 16 64 79 Full range5 16 80 95 Full range6 16 96 111 Full range7 16 5 112 127 Full range8 16 X Range Adjust 128 143 Full range9 16 144 159 Full range10 16 160 175 Full range11 16 176 191 Full range12 16 192 207 Full range13 16 208 223 Full range14 16 224 239 Full range15 16 240 255 Full range 100 0 15 Full range1 16 16 31 Full range2 16 32 47 Full range3 16 48 63 Full range4 16 64 79 Full range5 16 80 95 Full range6 16 96 111 Full range7 16 6 112 127 Full range8 16 Y Range Adjust 128 143 Full range9 16 144 159 Full range10 16 160 175 Full range11 16 176 191 Full range12 16 192 207 Full range13 16 208 223 Full range14 16 224 239 Full range15 16 240 255 Full range 10096 16 21 Laser 100 manual_en doc
15. mpulsorily SAFE USAGE OF THE PROJECTOR KEY WORD LASER SAFETY USAGE 5 21 Laser 100 manual_en doc The following points are important for safety as well as for the smooth installation and performance of the unit When unpacking and before disposing of the carton check there is no transportation damage before using the projector Keep the carton well for future possible transportation Should there be any damage caused by transportation consult your dealer and do not use the apparatus The projector is for Indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects The projector is not designed or intended to be mounted directly on to inflammable surfaces X The projector is only intended for installation operation and maintenance by qualified personnel The projector must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Do not project the beam onto inflammable surfaces minimum distance is 3m 3m E Avoid direct exposure to the light from the lamp The light is harmful to the eye Do not attempt to dismantle and or modify the projector in any way Electrical connection must only be carried out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the
16. ns ON or no means OFF N NO Y YES Press the key ENTER to save the selected function and configuration If the display is showing y then the setting has been enabled In the same way if it was showing n when you pressed ENTER the option has been disabled The Red LED will flash during this operation ENTER During function set operation Green LED will flash one time when press to indicate the set is valid The Red LED will be lit when DMX512 signal is normal Note 1 The codes 3 4 and 5 should be set no When operation 2 When under sound activation can use controller to adjust or set 3 Y condition 3 When use DMX512 controller codes 4 5 and 6 should be set no 4 Adjust 1 Y and 2 Y to select suitable display direction according to the actual installation direction XLR CONNECTORS AND TERMINATOR XLR CONNECTORS DMX IN DMX OUT DMX512 JE R iy 2 y N 27 AA PIN FUNCTION a 7 i I GH 2 DATA 3 3 DATA Connection between controller and projector and between one projector and another must be made with 2 core screened cable with each core having at least a 0 5mm diameter Connection to and from the projector is via cannon 3 pin XLR plugs and sockets which are included with the projector The XLRs are connected as shown in the figure above Note care should be taken to ensure that none of the connections touches the body
17. of the plug or each other The body of the plug is not connected in any way The LAZER 150 accepts digital control signals in standard DMX512 1990 format 5 PIN AND 3 PIN CONVERSION LAZER 150 uses 3 pin XLR plug socket If your controller uses 5 pin XLR plug socket you should convert 5 pin plug socket into 3 pin socket plug as shown below 5 PIN SOCKET Pin 1 GND Screen Pin 2 Signal data Pin 3 Signal data Pin 4 N C Pin 5 N C 3 PIN PLUG Pin 1 GND Screen Pin 2 Signal data Pin 3 Signal data m mxul l _ T 9 21 5 PIN PLUG Pin 1 GND Screen Pin 2 Signal data Pin 3 Signal data Pin 4 N C Pin 5 N C 3 PIN SOCKET Pin 1 GND Screen Pin 2 Signal data Pin 3 Signal data Dm u I Laser 100 manual_en doc DMX TERMINATOR In the Controller mode or Master Slave mode the DMX output has to be connected with a DMX terminator at the last fixture in the chain This prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 1200 ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in the chain The connections are illustrated below DMX TERMINATOR CONNECTION Connect a 120 OHM resistor across pins 2 and 3 in an XLR plug and insert into the
18. or dealer ACCESSORIES THESE ITEMS ARE PACKED TOGETHER WITH THE PROJECTOR Power cord 1 PCS XLR cable with 3 pin plug and socket 1 PCS Cable of data refreshes 1 PCS CD included this manual 1 PCS Laser key 2 PCS Urgency laser safety switch Connector 1 set INTRODUCTION Thank you for purchasing our product LAZER 150 PR 5030A series This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference The LAZER 150 is an innovative projector with an elegant housing which is made from high intensity and heat resistant complex plastic LAZER 150 complies with CE norms and standards and uses international protocol DMX 512 The LAZER 150 uses 16 DMX channels Through DMX 512 controller you can select the pictures and their movement changing methods so you can get charming and dreamful effect of the various laser pictures The projector has 3 group of sound activation demo so makes light and sound uniformity come true You can get impact effect using the music together The unit has reliable safety equipments Once the errors occur the unit will be cut off automatically It is suitable for application in TV station discotheque singing and dancing stage nightclub bar press conference exhibition etc The projector uses green solid laser lamp for light source This series also has PR
19. power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any dimmer pack Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the plug Never pull out the plug by tugging the power cord The projector should always be installed with a secondary safety fixing A safety cord is supplied for this and it should be attached as shown in installing the projector section There are no user serviceable parts inside the projector Please do not open the housing and never operate the projector with the covers removed Always disconnect from the mains when the device is not in use or before cleaning it or before attempting any maintenance work If you have any questions do not hesitate to consult your dealer or manufacturer 6 21 Laser 100 manual_en doc INSTALLING THE PROJECTOR 226 151 205 Um 261 248 Always ensure that the projector is firmly anchored to avoid vibration and slipping whilst functioning Always ensure that the structure to which you are attaching the projector is sec
20. se a dry ice machine to produce the fog 2 Please use the special cleaning products in cleaning the optics inside the unit The operation must be completed by qualified personnel 3 The scanner drive PCB and scan head inside the unit are used by couple They must be changed together The operation must be completed by qualified personnel 17 21 Laser 100 manual_en doc ELECTRICAL DIAGRAM a PR 5030A circuit diagram eU cf GA a S CEN ME Ty al a Y o O E RED BLACK SCAN DI REV4 1A Jl oO X MOTO NL i f gt D
21. set the DMX start address The display will show the latest setting each time the projector is powered up To control the projector with a DMX controller the DMX start address must be set Ensure that none of the Stand Alone options is set or they will interfere with correct DMX operation SETUP OPTIONS PROJECTOR CONFIGURATION To browse through the various Setup Options press the FUNC button consecutively There are 11 Option codes 1 B and each code has a specific function The functions provided are listed in the following table SETUP OPTIONS CODE CHOICE FUNCTION 4 No pan mirror Pan mirror No tilt mirror Tilt mirror Run sound activation demo 1 Run sound activation demo 2 Run sound activation demo 3 Stop sound activation demo Self test enable Self test disable Without DMX512 built in DEMO program enable Connect DMX512 Run sound activation demo 1 2 3 and built in DEMO program according to music Built in DEMO program disable Not used Not used Not used Not used Not used Not used 2 z lt z o m lt z lt lt Z u gt o o S When under functional operation the display format of the digital display screen is 8 21 Laser 100 manual_en doc x PBE BER 1 ak n Once you have selected the desired operation code press the key JUP or DOWN to select y mea
22. ure 3 111 147 Unit ON effect ENILONIOFP 148 184 Unit ON sound activation 1 185 221 Unit ON sound activation 2 222 255 Unit ON sound activation 3 Term explanation Animation a program made by a group of constant pattern Geometric picture static picture users can edit moving effect via DMX512 controller Effect pictures have had movement parameters users cannot edit The following channels are only for channel 1 value 64 127 animation CHANNEL DMX VALUE DESCRIPTION 0 25 Animation 1 26 51 Animation 2 51 76 Animation 3 76 102 Animation 4 Ei ER 102 127 Animation 5 Selection 127 153 Animation 6 153 178 Animation 7 178 204 Animation 8 204 229 Animation 9 229 255 Animation 10 3 Not used 0 25 Animation movement 1 fastest 26 51 Animation movement 2 52 77 Animation movement 3 78 103 Animation movement 4 4 104 129 Animation movement 5 Animation movement 130 155 Animation movement 6 156 181 Animation movement 7 182 207 Animation movement 8 208 233 Animation movement 9 234 255 Animation movement 10 slowest 0 15 Full range 1 16 16 31 Full range 2 16 32 47 Full range 3 16 48 63 Full range 4 16 64 79 Full range 5 16 80 95 Full range 6 16 96 111 Full range 7 16 5 112 127 Full range 8 16 X Range adjust 128 143 Full range 9 16 144 159 Full range 10 16 160 175 Full range 11 16 176 191 Full rang
23. ure and is able to support a weight of LAZER 150 For safety the projector should have a secondary fixing with a safety chain through the holes on the underside of the unit WARNING The projector should NEVER be lifted or carried by the yoke POWER SUPPLY MAINS Use the plug provided to connect the mains power to the projector paying attention to the voltage and frequency marked on the panel of the projector It is recommended that each projector be supplied separately so that they may be individually switched on and off L 58 Ay sl E FR ls f z NGS FUSE F 1 A 250V om IMPORTANT It is essential that each projector is correctly earthed otherwise hardware inside the projector may cause unexpected damage 7 21 Laser 100 manual_en doc OPERATION The unit uses standard DMX 512 controller With the touch switches and the digital display screen DMX start GREENLED RED LED address can be easily set and the various setup options y I 2 may be configured i Zus The display shows the DMX start address after the projector is switched on if you have already set the DMX start address and saved it the screen will display w Mx the last setting FUNC DOWN ENTER TO SET THE DMX START ADDRESS Press the JUP or DOWN I buttons and the display will show the DMX start address Confirm your choice by pressing the ENTER button this will save and