Home
user manual som series mul-t-poise warm air oil fired
Contents
1. SUMMERAIRE Built Better to Last Longer USER MANUAL SOM SERIES MUL T POISE WARM AIR OIL FIRED FURNACE Save These Instructions For Reference ALL SOM SERIES FURNACES ARE AIR CONDITIONING READY NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND WHERE REQUIRED BY LAW A LICENSED TECHNICIAN NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SOM SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS2 C TJERNLUND SIDEWALL POWER VENTOR IT IS YOUR RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE SNOW AND DEBRIS FOR SERVICE CALL INSTALLATION INFORMATION Installing Contractor Telephone Number Unit Model Number Unit Serial Number Installation Date Summeraire Mfg Peterborough Ontario K9J 7B1 OCT 2007R OPERATING INSTRUCTIONS CAUTION NEVER BURN GARBAGE REFUSE OR PAPER IN THE HEATING UNIT NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE IDENTIFY THE LOCATION OF YOUR BURNER FURNACE POWER SWITCH OIL BURNER OPERATING INSTRUCTIONS e Use No 2 furnace oil ONLY Do not use gasoline crankcase oil or any oil containing gasoline Do not attempt to start the burner if excess oil has accumulated when the furnace is full of vapor or if the combustion chamber is hot Press the burner relay reset button ONLY ONCE if the burner fails to start call an Oil Burner Technician If the oil burner is to be shut off for a
2. ON position If you hear a hum from the oil burner and the motor has not started press the reset button on the burner motor once only Blown fuse tripped breaker in electrical panel Thermostat may be set below room temperature Burner relay combustion control may have to be Oil valve may be closed Oil supply may be too low Blocked flue sensor tripped If the oil burner fails to start or runs for only a few seconds call a qualified service technician reset press reset once only FAN CONTROL INFITEC Part No DFS530S8180 The Fan Control used on the Summeraire SOM series of furnaces is controlled by a Timed Relay After Burner Ignition the blower will start after 30 seconds The blower turns Off or returns to Constant Speed 3 minutes after the Oil Burner shuts OFF There is NO ADJUSTMENT on the Timed Relay DUAL AIR OPERATION This furnace is equipped with a dual two speed blower system which allows partial air distribution at all times When the thermostat calls for Heat the Oil Burner starts and the HIGH speed quickly distributes warm air throughout the home When the HIGH SPEED stops the LOW speed continues operating circulating the air to even the temperature throughout the house If the LOW speed feature is not required desired operate the small rocker switch located on the power junction box MAINTENANCE
3. OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service technician and where required by law a licensed technician CAUTION Do not use any commercially available soot remover Use extreme caution when servicing since the combustion chamber is fragile Routine cleaning of the flue passages does not require cleaning the combustion chamber If for some reason it is necessary to work in the area of the combustion chamber do not touch or alter the chamber position Before cleaning shut off electrical power supply to the furnace Note Always keep oil supply valve shut off if burner is shut down for an extended period of time The nozzle should be replaced annually handle nozzle with care so that the inside surface tip is not scratched The electrodes should be cleaned and adjusted see oil burner manual supplied with the oil burner LUBRICATION Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil port s located at either end of the burner motor Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil ports located at either end of the blower motor DO NOT OIL THE FAN BEARINGS CLEANOUTS SOM SERIES Remove smoke pipe from furnace and chimney Remove any soot that may be present Remove cleanout panel from front of unit Remove the centre cleanout panel and the round disc type cleanout covers located on either side
4. of the centre cleanout panel Remove the baffles in the secondary heat exchanger tubes Loosen soot from the tubes with a cleaning tool or brush Remove all loose soot with a vacuum cleaner suitable for this purpose Inspect passages to check for missed areas When reinstalling the cleanout cap make sure to replace the gasket Reassemble heat exchange cleanout covers and replace gaskets NOTE WE RECOMMEND THAT A QUALIFIED MECHANIC OR WHERE REQUIRED BY LAW A LICENCED MECHANIC ONLY SHOULD PERFORM ALL SERVICE AND CLEANING OF YOUR SUMMERAIRE FURNACE AIR FILTER This furnace should never be operated without filters A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the type or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace AIR FILTER SPECIFICATIONS Filter size SOM75 16 X 20 X 1 CSA or ULC Certified Approved Type Throw away disposable SOM95 16 X 20 X 1 CSA or ULC Certified Approved Type Throw away disposable SOM125 20 X 25 X 1 CSA or ULC Certified Approved Type Through away disposable USE OF FILTERS OTHER THAN THOSE SPECIFIED ABOVE CAN CAUSE DANGEROUS ELEVATION OF FURNACE TEMPERATURES THIS IS AN UNSAFE CONDITI
5. ON DO NOT USE INSTALL PLEATED TYPE AIR FILTERS IN THIS FURNACE WARNING Your furnace requires Combustion Air DO NOT close off furnace room or enclose furnace this will starve to furnace oil burner for air necessary for combustion and could result in a dangerous situation NOTE IF YOUR SUMMERAIRE FURNACE IS INSTALLED WITH A SS2 C TJERNLUND SIDEWALL POWER VENTOR IT IS THE USERS HOMEOWNERS RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE SNOW AND DEBRIS WARRANTY Summeraire Mfg warrants that it will supply to the owner of a Summeraire Oil furnace that has been installed in Canada a replacement Heat Exchanger Heat Element free of charge F O B Factory Peterborough Ontario Canada If the said Heat Exchanger wears out or fails under normal use and service due to a defect in material or workmanship during the first Twenty 20 years after the date of installation and only if the following conditions have been met 1 The furnace has been installed and maintained in accordance with accepted practices as recom mended from time to time by the Heating Refrigeration and Air Conditioning Institute of Canada The National Building Code or CSA standard B139 by a qualified installer 2 The furnace has been operated with an input rate not in excess of the rating and fuel as specified on the rating plate attached to the furnace 3 The furnace has not been operated with out the use of the proper automatic lim
6. by acceptance of this Equipment assumes all liability for the consequence of its use or misuse by the purchaser his employee or others This Warranty is for the benefit of the owner of the furnace and terminates in the event of any altera tions not specified by Summeraire Mfg and other than herein provided No further or other warranty express or implied is granted by this warranty and no liability shall accrue for any consequential dam age resulting from alleged defects in the Heat Exchanger or its component parts Mechanical components for this furnace are covered under a five 5 year warranty If these components fail under normal use and service within five 5 years from date of installation the defective part will be replaced free of charge F O B our factory in Peterborough Ontario The Model Number and Serial Number of your Summeraire Furnace must accompany all claims for warranty 6 F SOM USMAN EN REV4
7. it control on the maximum warm air temperature 4 That the furnace has not been operated without adequate air circulation over it 5 Proof satisfactory to Summeraire Mfg that the defect claimed has not been caused by damage to or destruction of the furnace 6 The furnace has remained at all times in the place of initial installation 7 Written notification of the failure under terms and conditions of this warranty are provided no later than thirty 30 days after the expiration of this warranty whichever shall first occur 8 No mechanically cooled air Originating in the return air duct shall be circulated over the heat exchanger of the furnace 9 The owner must provide proof that the appliance has been serviced annually including annual cleaning of the complete furnace and inspection of the heat exchanger 10 The unit must not be installed in any structure where a corrosive atmosphere exists as may be found in dry cleaning establishments Laundromats Beauty Salons etc 11 Summeraire Mfg shall not be responsible for any failure due to water damage and or Acts of God 12 No Air Conditioning or Heat pump coil may be installed on the return air side of this furnace This warranty expressly supersedes all other warranties and obligations of Summeraire Mfg No person has authority to alter or modify the terms of this warranty in any manner Summeraire Mfg assumes no liability for consequential damages of any kind and the purchaser
8. ny period of time shut the oil valve OFF at the oil tank Do not adjust or tamper with the furnace or any of the controls Do not burn garbage or paper in this unit e Never leave paper rags or other combustibles around the furnace Only qualified or where required by law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close all oil supply valves The heating system should be checked and cleaned if necessary RESTARTING BURNER AFTER EXTENDED SHUT DOWN The complete oil burner should be checked and serviced by a qualified technician Check oil pump strainer Replace oil filter cartridge Check electrodes Oil burner motor see lubrication section Restart burner by following instructions in STARTING THE OIL BURNER section If your furnace has been shut off for an extended period contact your qualified service technician for start up BURNER FAILS TO OPERATE Always call a qualified technician The trouble may be Raise your thermostat to 5 C 10 F above present room temperature Make sure your Oil Burner power switch is in the
Download Pdf Manuals
Related Search
Related Contents
TECHNICAL DATA & SERVICE MANUAL SPLIT 工事説明書 - 長府工産株式会社 埼玉県食肉衛生検査センター Termómetro electrónico - edUTecNe Biofixe agréée Biofixe Agréée MOVIMOT® MM..B Kit de montaje / Manual de instrucciones / 2001-11 Philips SA2120 2GB* Flash audio player Adjust-A-Gate AG60-3 Instructions / Assembly Copyright © All rights reserved.