Home
        SILADENT-TECHNIK GmbH - SILADENT Dr. Böhme & Schöps GmbH
         Contents
1.     To enter the password use the A or V buttons to select 2 as the first digit      Press the    button    10  Use the A or V buttons to select 5 as the second digit    11  Press the    button twice    12  Use the arrow buttons in the same fashion to enter the weight of the object being  used for calibration    13  Press the    button    14  Place the weight on the scale    15  Press the Enter button    16  The screen will display Yes or No  If yes is selected  the unit will begin to calibrate the  scale  If no is selected  the display will return to the main menu    17  Check calibration with the weight from above using Scale Mode     WHNAUAWN    Scale Mode   Scale mode will cause the unit to operate like a laboratory scale  The unit will not show a  negative weight  If needed  use the Tare button to re set the zero of the scale    1  Press the Menu button    2  Use the A or V buttons to select Special Functions    3  Press the Enter button    4  Use the A or V buttons to select Scale Mode    5  Press the Enter button  The scale can now be used to accurately weigh an object     If checking calibration   6  Place the same weight used during calibration on the scale   7  Check the weight displayed against the known weight of the object   8  If the weight displayed does not match the known weight  then repeat the calibration  process  Otherwise press Menu or Abort to return to the main menu     SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental 
2.   HO    SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar       Front View     Arm to access       hose  Distilled Expansion  water liquid  SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de    D 38644 Goslar       Back View     Scale  socket    ON   OFF g  Switch        Power cord  socket    Expansion Distilled  liquid water  SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21  37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de    D 38644 Goslar       J SILADENT    After unpacking the dispenser and all of its accessories  please follow these installation  instructions  Place the dispenser on a level surface  Position scale between the base legs of  the dispenser  shown on page 2   Align scale so that the scale cover is directly beneath the  dispensing hose  Do not allow scale chassis to contact column or feet of dispenser   this contact may result in inaccuracy     Slide scale cord between stand and water bottle and attach the scale cord to the scale socket  on the back of the unit  shown on page 3   Fill the water bottle with distilled water  secure  cap and place the bottle on the left side of the unit  Use water only  chemicals added  here may damage the internal pumps  You may use the included extension hose and  inline hose 
3.  is free of debris and crystallized particles  OR Out of Special Liq   Tightly secure the bottle cap  error   Gently pinch the end of the special liquid hose to free crystallized  particles    Replace the special liquid cap assembly    Unit hums loudly   Ensure the bottle cap is free of debris and crystallized particles    Tightly secure the bottle cap    Replace the special liquid cap assembly    Special liquid will not stop    Check that special liquid hose is uniformly seated in the pinch  i valve  see page 10     Replace the special liquid cap assembly    Castings are too large   Reduce special liquid concentration by 0 5 ml or 1  until size is  correct   Castings are too small   Increase special liquid concentration by 0 5 mL  or 1  until size is correct       SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar    Technical data   Dimensions    Weight    User Programs   Display Characters   Operational Altitude     Operation Temperature     Maximum Relative Humidity     Pollution Tolerance     Recommended Environment     Warranty     SILADENT Dr  B  hme  amp  Sch  ps GmbH    Im Klei 26  D 38644 Goslar    J SILADENT       30 cm W x 59 cm H x 33 5 cm D  200 240 VAC  50 60 Hz    15   4 lines x 20 characters   Sea level   2 000 meters  6 560 feet   130 C   419 C  550 F   105   F     80  for temperatures to 35   C  950 F  decreasing linearly to  50  relative humidity 
4. J SILADENT  LD 1    Water and expansion liquid dispenser            for dental gypsum and investments     15 memory spaces for programs of different products     eliminates handling mistakes with the liquid and water ratio    exact control of the expansion      constant and reproducible casting results    SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar    J SILADENT       Application range    The LD1 is a multifunctional dispenser unit  Automatically it adds the exact needed water or  liquid ratio to all kinds of amounts of investments or gypsums you use  Operating errors will  be avoided because of its 15 freely configurable programs  This causes a short handling time   exact expansion data and hardness which reduce reworking and achieve qualitative high end  results     BOX CONTENTS    1   Power Cord   1   User   s Manual   4   1 Liter Bottles   1   Scale   1   Scale Cover   1   4 ft  Clear Extension Hose   1   Inline Hose Connector   1   Funnel   1   Quick Start Guide   1   Water Bottle Cap and Tubing  4   Special Liquid Bottle Caps and Tubing    TABLE OF CONTENTS  Front Back View   Set Up   Programming the LD1  Running a Program    I  D    auuw  NO    Special Functions   Calibration   Scale Mode   Set Language  Erase a Program  Purge Liquid  Prime Water Hose  Maintenance  Replacing the Special Liquid Hose  Troubleshooting  Technical data    FPrWOWOMOMOOAOONN  
5. arm  Allow the hose to extend  approx  1 inch below the opening        Fig  3  Place your thumb on the hose nearest the white pinch valve and  hold with direct pressure     Fig  4   Stretch the hose and slide into the pinch valve  The hose should  Slide in easily  if not  stretch the hose further  Thread the other  end of the hose through the opening in the outer  rear    of the swing arm  assuring there are no kinks in the hose  Place  the hose onto the center nodule on the cap        SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar    J SILADENT       TROUBLESHOOTING    Screen lights up  but no    Check the scale cable connection  words are displayed    Will not dispense water   Ensure there is sufficient water in the container  Or Out of Water error   Ensure the clear hose is fully seated on the center of the bottle  cap    Remove excess air from the hose by running the Prime Water  Hose cycle    Be sure dispensing is completed before removing bowl from scale    Dispensed too much Make sure the bowl finished the Tara before adding the powder   water    Water and or special   Since the unit weighs the amount of water  special liquid in the  liquid splashed from bowl   bowl  this will not affect accuracy    Check alignment of scale    Excessive clicking or will    Ensure there is sufficient liquid in the bottle  not dispense special liquid    Ensure the bottle cap
6. at 35   C  104   F     Level 2  in accordance with IEC 664   Vertical position  indoors within operational parameters     2 years parts and labor    Tel    49  0  53 21 37 79 0  Fax   49  0  53 21   38 96 32    info sbs dental de  www sbs dental de    
7. connector to allow the use of a larger container  such as a one gallon jug  Insert  the connector end into the clear tubing from the unit and place the hose directly into a  container     The special liquid bottle can be filled with investment liquid or die stone additive  Fill the  special liquid bottle with liquid  secure cap by holding the cap and turning the bottle until  tight  Place the bottle on the right side of the unit  The special liquid bottle is pressurized  during operation  If the cap is not tightly secured  air will escape and the liquid will  not flow properly     Insert the power cord into the socket on the back of the unit  see page 3  and plug the power  cord into an outlet  Turn the unit on using the switch located on the back of the unit     CAUTION  Do not interchange the bottle caps  The gray cap is for the special liquid side only   and the blue cap is for the water side only     PROGRAMMING THE LD       Programs can be added or edited in two ways  The first method is g ml  a program based on  grams of powder and mL of water and or liquid  i e  100 grams of powder   18 mL special  liquid and 5 mL water   The second method is by grams of powder and percentage     of  special liquid  i e  100 grams of powder   80  special liquid and 20  water   Your current  lab method or manufacturer   s documentation may dictate which programming method to use     Note  The unit will dispense water and  or special liquid accurately for up to 1200  grams of powder  eve
8. de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar          SILADENT  Set Language       Use the A or V buttons to move the cursor to the desired language    The unit can display in English  French  German  Italian and Spanish    Press the enter Key    The unit will prompt for confirmation  Press Enter to confirm  or press the Abort to  abort and return to main menu     Bal ea    Erase a Program    Press the Menu button    Use the A or V buttons to select Special Functions    Press the Enter button    Use the A or V buttons to select Erase a Program    Press the Enter button    Use the A or V buttons to select the program number  1 15  to erase    Press the Enter button    Press the Enter button again to erase the program or press the Abort button to return  to the main menu without erasing the program     SS OV OT Si    Purge Liquid   This function allows you to flush the special liquid hose  This may be useful if changing  between bottles that contain differing liquids  while using the same cap and hose assembly     Press the Menu button    Use the A or V buttons to select Special Functions    Press the Enter button    Use the A or V button to select Purge Liquid    With a container on the scale  press the Start button    After the first few drops fall from the hose  press Abort to end     a   W    Prime Water Hose   Use this function if you encounter an Out of Water error and there is water visible in the  bottle  or other container      1  Pres
9. e the program  Press  the  gt  button to advance to the next position  Press the  lt  button to move back to the  previous space    7  Once the name is complete  press the Enter button to move to the next screen    8  Use the A or V buttons to enter the total liquid required  in mL  and powder  in    grams   Note  Total liquid required is total volume of both water and special  liquid in ml    9  Use the A or V buttons to indicate the special liquid concentration  This is the percent  of the special liquid only to be dispensed  0  dispenses only water  100  dispenses  only special liquid  You will not be required to enter the percent of water  i e  if you  enter 80  special liquid concentration  the unit assumes 20  water     10  Press the Enter button    11  The screen should display Program Saved     RUNNING A PROGRAM  Before running a program  check that the special liquid hose end is not clogged and will allow  special liquid to flow  see the Maintenance section on page 9 for more details      From the Main Menu    Use the A or V buttons and select Run Program    Press the Enter button    Use the A or V buttons to select the number of the program you wish to run  1 15    Place an empty bowl on the scale    Press the Tare button    Remove the bowl from the scale and place the desired powder into the bowl    Return the bowl to the scale   Press the Start button     Soe a ee    The dispenser will begin to dispense the liquids separately  beginning with water and finishing  w
10. ith special liquid  The display will indicate when the program is finished and the unit will  beep until the bowl is removed from the scale     Note  If the dispenser tries to dispense from either side for 30 seconds  15 seconds for the  water only unit  and the weight on the scale does not increase  it will give an error  Usually    SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar    J SILADENT    this means it is out of water  special liquid or the special liquid hose may be clogged  see  Maintenance section on page 9 for more details   Due to set time we suggest that the failed  batch be thrown away  Refill the empty bottle and then re run the program with fresh  investment or stone        SPECIAL FUNCTIONS MENU    Calibration    The scale arrives calibrated from the factory  The calibration information is stored in the  scale  so changing scales will not necessitate a recalibration  The scale should rarely  if ever   need to be calibrated     1  Obtain a 500 g to 1200 g known weight  If needed  weigh an object on a separate   scale in order to calibrate the dispenser    Be sure the rubber scale cover is clean    Press the Menu button    Use the A or V arrow buttons to select Special Functions    Press the Enter button    Use the A or V arrow buttons to select Calibration    Press the Enter button  The display will read    Enter Password     The password is 250 
11. n if the program entered is based only on 100 grams of  powder  g mL program add edit mode    1  Press the Menu button    2  Use the arrow buttons to select Edit Program by mL g    3  Press the Enter button    4  Use the A or V buttons to select a program number  1 15     5  Press the Enter button    6  Use the A or V buttons to select the numbers or letters to name the program  Press  the  gt  button to advance to the next position  Press the  lt  button to move back to the  previous space    7  Once the name is complete  press the Enter button to move to the next screen    8  Use the A or V buttons to enter the amount of powder  in grams     SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de    D 38644 Goslar    J SILADENT    9  Use the A or V buttons to indicate the amount  mL  of Special Liquid to dispense per  the given powder weight above    10  Press the Enter button    11  Use the A or V buttons to indicate the amount  mL  of Water to dispense to complete  the total ratio  in ml     12  Press the Enter button when complete    13  The screen should display Program Saved          program add edit mode    1  Press the Menu button    2  Use the A or V arrow buttons to select Edit Program by      3  Press the Enter button    4  Use the A or V buttons to select a program number  1 15     5  Press the Enter button    6  Use the A or V buttons to select the numbers or letters to nam
12. s the Menu button    2  Use the A or V buttons to select Special Functions    3  Press the Enter button    4  Use the A or V button to select Prime Water Hose    5  With a container on the scale  press the Start button    6  After air is removed from hose  press Abort to end   MAINTENANCE    Note  Some special liquids crystallize when exposed to air  and may impede dispensing of  special liquid  Daily maintenance is required     SILADENT Dr  B  hme  amp  Sch  ps GmbH Tel    49  0  53 21 37 79 0 info sbs dental de  Im Klei 26 Fax   49  0  53 21   38 96 32 www sbs dental de  D 38644 Goslar          SILADENT    With a damp paper towel  gently pinch the tip of the Special Liquid hose to free crystallized  particles  This should be done each morning before use and any time the dispenser has not  been used for several hours     As needed   1  Wipe down the unit with a damp cloth   2  Remove the scale cover and clean   3  If the special liquid hose develops a clog that is not near the open end  replace it     Replacing the Special Liquid Hose     Fig  1   To replace the special liquid hose  losen the LD1 bottle cap to  depressurize the bottle and swing open the arm as shown   Remove the white hose from the center nodule of the cap  place  your thumb on the hose nearest the white pinch valve  Fig  3    stretch the hose  Fig  4  and remove the hose from the pinch  valve     Fig  2   Insert the end of a new  white special liquid hose into the round  opening on the inside  left  of the 
    