1. Cl ity Laser Measurement Acuity Touch Panel Display User s Manual Model ARZIOSO 0 8942 Manual p n LLL009010 Rev 2 0 For use with Acuity products June 29 2009 Acuity A product line of Schmitt Industries Inc 2765 NW Nicolai St Portland OR 97210 www acuitylaser com Limited Use License Agreement YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE OPENING THE PACKAGE CONTAINING THE COMPUTER SOFTWARE AND HARDWARE LICENSED HEREUNDER CONNECTING POWER TO THE MICROPROCESSOR CONTROL UNIT INDICATES YOUR ACCEPTANCE OF THESE TERMS AND CONDITIONS IF YOU DO NOT AGREE WITH THEM YOU SHOULD PROMPTLY RETURN THE UNIT WITH POWER SEAL INTACT TO THE PERSON FROM WHOM IT WAS PURCHASED WITHIN FIFTEEN DAYS FROM DATE OF PURCHASE AND YOUR MONEY WILL BE REFUNDED BY THAT PERSON IF THE PERSON FROM WHOM YOU PURCHASED THIS PRODUCT FAILS TO REFUND YOUR MONEY CONTACT SCHMITT INDUSTRIES INCORPORATED IMMEDIATELY AT THE ADDRESS SET OUT BELOW Schmitt Industries Incorporated provides the hardware and computer software program contained in the microprocessor control unit and licenses the use of the product to you You assume responsibility for the selection of the product suited to achieve your intended results and for the installation use and results obtained Upon initial usage of the product your purchase price shall be considered a nonrefundable license fee unless prior written waivers are obtained from Schmitt I
2. 485 ee meas meae A Acuity Touch Panel Display User s Manual 33 i Revision 2 0 Acuity AR200 Model part model numbers chart R 18 24mm SER ARA A 0 012 mm L 69 8mm R 14 26mm dina dalia A 0 024 mm L 69 8mm R 21 5 46 5mm in de A 0 05 mm L 69 8mm R 17 67mm Ai ARACO A 0 10 mm L 69 8mm Acuity Touch Panel Display User s Manual 34 Revision 2 0 Acuity
3. road profiling option 152 4mm span 20mW visible diode Bandpass filter 132 mm case 2m cable AP7220080 AR700 8 5mW AR700 8 203 2mm span 5 mW visible diode 132 e amean aane a o E AP7230080 AR700 8 20mW AR700 8 203 2mm span 20 mW visible diode E AN Gomme emee o S AP7234080 AR700 8 RP AR700 8RP road profiling option 203 2mm span 20mW visible diode Bandpass filter 132 mm case 2m cable AP7420120 AR700 12 5mW AR700 12 304 8 mm span 5 mW visible diode Oe EN aT mmesema o o AP7430120 AR700 12 20mW AR700 12 304 8mm span 20 mW visible diode ei e AP7220120 AR700 12C 5mW AR700 12 304 8mm span 5 mW visible diode ie i AP7230120 AR700 12C AR700 12 304 8 mm span 20 mW visible diode AP7434120 AR700 12 RP AR700 12RP road profiling option 304 8 mm span 20mW visible diode Bandpass filter 132 AP7420160 AR700 16 5mW AR700 16 406 4 mm span 5 mW visible diode S e AP7430160 AR700 16 20mW AR700 16 406 4mm span 20 mW visible diode i ee AP7620240 AR700 24 5mW AR700 24 609 6 mm span 5 mW visible diode n AP7630240 AR700 24 20mW AR700 24 609 6mm span 20 mW visible diode eI as mensa eae AP7620320 AR700 32 5mW AR700 32 812 8 mm span 5 mW visible diode Vesna moame o o oo AP7630320 AR700 32 20mW AR700 32 812 8 mm span 20 mW laser diode Ame amene o S AP7620500 AR700 50 5mW AR700 50 1 27 m span 5 mW laser diode 485 A T measa amean o S AP7630500 AR700 50 5mW AR700 50 1 27 m span 20 mW laser diode
4. A CE Mark CISPR22 CNS13438 EN55022 ICES 003 VCCI operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This manual copyright 2009 Schmitt Industries Inc Acuity Touch Panel Display User s Manual 4 Revision 2 0 Acuity Table of Contents Limited Use License Agreement xctcceciedcesescntarsanressesiesiwecedueeinsthecetadeatuesaiesedateleedecreacacsdveaes 1 Procedures for Obtaining Warranty SErvice 4 TADO GONGA ear E E E eda 5 Taleo ROUTO arenaria 6 T Modun ri E rio ei 1 1 1 anora OVVIE W n a EEEE in 1 1 2 Definition of TermS seca cece eecececeeeeeueeseeeeseeeseeeseuseseeeesee
5. Acuity Touch Panel Display User s Manual 1 Revision 2 0 Acuity 1 3 1 Power connections To operate the TPD with an Acuity laser sensor both items must be connected to an appropriate power supply The TPD and sensor may utilize the Same 12 24V DC power supply and it is recommended that a TPD be ordered with optional Acuity Connectivity Kits to simplify these connections 12 24 VDC Ground Figure 1 Terminal blocks on rear of TPD For custom installations connect the Supply and Ground lines to TPD Make Sure your power supply is unplugged from its source Locate the double terminal block on the rear panel of the TPD Connect the Ground to the right terminal block Connect the Supply voltage 12 24 VDC lt 1A to the left terminal block Be sure that your Acuity laser sensor is properly wired with the appropriate power supply For detailed installation instructions consult documentation furnished with each Acuity product 1 3 2 Serial Communications Connections The TPD requires serial interface connections with your Acuity sensor Locate the triple terminal block on the rear panel of the TPD that is immediately next to the five block terminal Connect TX RX and Ground leads according to the following illustration TX RX Ground Figure 2 Function of individual RS232 terminal blocks Acuity Touch Panel Display User s Manual 2 Revision 2 0 Acuity 1 3 3 Activation Turn on the power source to both the TPD
6. Do not attempt to loosen any screws or open the housing Occasionally Acuity will provide firmware upgrades for the TPD on its website Instructions for installing this firmware on the TPD are provided in section 5 TPD Specifications Go to http www acuitylaser com pdf Touch Panel Display pdf Acuity Touch Panel Display User s Manual 6 Revision 2 0 Acuity Ge Installation and Checkout 3 1 Mounting The TPD may be mounted in an electrical panel or free standing on a workbench Remove the six nuts threaded to the mounting bolts on the rear side of the Display Be sure to drill holes in the appropriate spot on the panel door and also cut out a rectangular opening large enough to accommodate the metal housing of the TPD Use the mechanical drawing located in section 2 2 Secure the TPD to the panel by tightening the six nuts back onto the threaded bolts such that the foam gasket compresses underneath the bezel When panel mounted with the attached foam gasket the unit is water resistant to NEMA 4X IP65 3 2 Cabling The TPD requires power and data communications connections directly or through an optional Connectivity Kit Direct connection requires that the user make the appropriate connections to the appropriate terminal block on the rear of the TPD Below is a description of the terminal block connections on the rear of the TPD R amp 232 RS 485 RTG R P T T pn ra Figure 4 Rear of TPD showing connection blocks for Sen
7. T pairs The T T send the laser data using the Acuity Touch Panel Display User s Manual 9 Revision 2 0 Acuity physical RS485 RS422 signaling levels RS485 protocols are ideal for transmitting serial data over long distances The TPD R R pair is not functional for communication with an external device and hence is not used with this version of TPD 3 4 Verifying Operation After turning on the power to both the sensor and the TPD the user should see the greeting screen Laser Measurement User Program Version 1 0 090603 started Touch screen to continue 3 4 1 Select the correct model If this is the first time you are connecting your sensor to the TPD it will not automatically recognize the sensor and its configuration and it will be necessary to program the TPD to properly communicate with your device As instructed touch the screen to continue to the Display screen and then press Setup ty Model None Laser Measurement W Press the Select Model button to setup the sensor you have connected to the TPD Acuity Touch Panel Display User s Manual 10 i Revision 2 0 Acuity Select Model O ARa Select the sensor series ARTO ARADO from the screen listing and press the ARo ARo corresponding button Select Model Select the sensor series _AR 100 0125 _AR700 0250 from the screen listing corresponding button 3 4 2 Run the Sensor The TPD will confirm your
8. TRANSFER POSSESSION OF ANY PORTION OF THE HARDWARE OR SOFTWARE TO ANOTHER PARTY YOUR LICENSE IS AUTOMATICALLY TERMINATED TERM The license is effective until terminated You may terminate it at any other time by returning all hardware and software together with all copies of associated documentation It will also terminate upon conditions set forth elsewhere in this Agreement or if you fail to comply with any term or condition of this Agreement You agree upon such termination to return the hardware and software together with all copies of associated documentation In the event of termination the obligation of confidentiality shall survive 12 MONTH LIMITED WARRANTY EXCEPT AS STATED BELOW IN THIS SECTION THIS PRODUCT IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Schmitt Industries Incorporated does not warrant that the functions contained in the product will meet your requirements or that the operation of the product will be uninterrupted or error free Schmitt Industries Incorporated does warrant as the only warranty provided to you that the product which is furnished to you will be free from defects in materials and workmanship under normal use for a period of twelve 12 months from the date of delivery to you as evidenced by a copy of your warrant receipt LIMITATIONS OF REMEDIES Schmit
9. a measured value that is between the Critical and Warning limits is displayed r in Pink Model AR4000 LV Laser Meare LLY The Main Display Screen with a measured value that has exceeded the Upper or Lower Critical limits is displayed in Red section 4 7 3 If you make a mistake press the Erase button to remove the right most digit When finished press the Done button to return to the Limits menu screen Press the Back button to return to the primary Settings menu screen Acuity Touch Panel Display User s Manual 19 Revision 2 0 Acuity 4 7 Rate and Calibration Settings The Rate amp Cal Rate and Calibration menu allows users to make several changes that affect the TPD and the sensor itself Included are altering the number of Significant digits displayed beyond the decimal point altering the sensor s Sampling speed providing a measurement offset performing a calibration specifying the number of distance samples to average before refreshing the display and controlling the sampling modes Model AR700 1 AR700 1 Sample Mode P The Rate amp Cal screen Single Shot i shows a variety of 0 0000 Dist Tracking E Close Rg D T parameters that can be changed by the user Calibrate 1 10Hz Dist T 4 7 1 Adjusting the Decimal Places This function is relevant to using the TPD with any Acuity sensor The TPD will by default display measurements to four decimal places and it
10. and the sensor s At the opening screen with the large Acuity logo touch the screen with your finger or stylus pen to continue to the configuration Never touch sharp metal objects or pens to the TPD screen Follow the menu sequence to SELECT MODEL Once you select the appropriate series AR200 AR700 etc Select the exact measurement model Ex AR200 25 AR200 50 etc Following your selection press RUN and on the Subsequent screen press LASER ON Be sure that the laser sensor is aimed at a target within its appropriate measurement range The TPD measurement screen will now display the measured value from the sensor For detailed instructions and setup consult the appropriate chapters of this manual Acuity Touch Panel Display User s Manual 3 Revision 2 0 Acuity 2 General Description The Acuity Touch Panel Display TPD is a stand alone user interface for use with Acuity laser distance sensors These fully enclosed units replace panel meters alphanumeric displays and analog controllers by providing a modern interface through a full color LCD and touch screen The Touch Panel Display communicates with one or two Acuity sensors using their serial interfaces Sensors can be easily configured using on screen buttons to display and scale their distance outputs All on screen instructions are in the English language Relative dimensions can be measured using a tare function The individual distance readings from two sensors
11. can be displayed simultaneously on the screen Furthermore with dual RS232 serial inputs from two acuity sensors the Panel serves as a thickness gauge and display an application which previously demanded a PC computer and custom software programming Using a single RS485 serial interface the Panel can transmit thickness and dimensional information to external devices The TPD firmware can be upgraded through the on board USB port with new revisions that are downloaded from the Acuity website free of charge 2 1 Principles of Operation The TPD communicates with Acuity sensors via an RS232 serial interface to display and process distance data from Acuity brand laser sensors The TPD can accept up to two serial connections to two sensors The unit can perform mathematical operations using the data from two sensors to calculate dimensional information for objects The TPD can output calculated data via an RS485 signal Acuity Touch Panel Display User s Manual 4 Revision 2 0 Acuity 2 2 Mechanical Dimensions 88 32 threaded etude FRONT 35 8 5 min length IRE 5 4 137 2 4 3 109 2 La ib T T se ll E i FROM COMPRESSED GASKET 4 9 124 9 Compressed Thickness O47 1 19 Uncompressed Thickness 082 2 34 che 3 83 97 3 U Y RY ih REAR Figure 3 Mechanical Dimensions of TPD Acuity Touch Panel Display User s Manual 5 Revision 2 0 Acuity Laser Measurement 2 3 Contents Your Touch P
12. it will recognize the hardware as a USB to RS232 converter Follow all on screen prompts to allow Microsoft Windows to automatically install the necessary drivers Acuity Touch Panel Display User s Manual 30 i Revision 2 0 Acuity Laser Measure Run the Bitmap Loader entitled ScreenUpdate that was previously downloaded from the Acuity website Within the Bitmap Loader screen select the serial port that has been assigned to the connected Touch Panel Display Select USB Autobaud Press the button for Select File and locate the new firmware version BIN file Typically this file is located in the same folder as the Bitmap Loader Finally press the Store into SLCD button The software will automatically delete the old firmware and install the new firmware Verify the correct installation by connecting a laser sensor and checking for proper distance measurements and specific TPD functionality Acuity Touch Panel Display User s Manual 31 Revision 2 0 Acuity Appendix 1 Acuity part model numbers chart AR4000 Model part model numbers Infrared beam Laser Diode Based Rangefinder with 0 54 range 0 1 accuracy RS232 interface aeons AERODEN NEMA 4 IP67 case Includes sensor 6 cables manual Visible beam Laser Diode Based Rangefinder with 0 40 range 0 3 accuracy RS232 interface plese weve dai NEMA 4 IP67 case Includes sensor 6 cables manual Eye Safe Laser Diode Based Rangefinder with 3 54 ran
13. of a calibrated standard such as a gauge block cuity Model AR1000 AR 000125 Select Model Select Mode Select Model Settings cuity Later Measurement Mode E Single Laser Thickness E Two Lasers Acuity Touch Panel Display User s Manual Revision 2 0 27 From the Setup Menu Press the Select Mode button After pressing the Select Mode button the Mode screen is displayed Press the Thickness Radio button and then the Back button Ac ty Laser Measurement Return to the main measurement screen by pressing Back Run and Laser On each of the subsequent screens At the main measurement screen press the Zero button The displayed dimension should be exactly equal to the dimension of the gauge block or reference standard target that is in the measurement paths of the opposing laser sensors From here users can place objects and materials between the two laser sensors and the Touch Panel Display will report their dimension Model AR700 1 AR 00 1 Sample Mode Single Shot From the Rate and Cal menu screen press the Dist Tracking Toim Close Rg D T Offset button cuit Model AR1000 ce AR700 0125 rom this menu enter the offset equal to the dimension of your gauge block Be sure to use the same units in mm etc Press Done when finished Laser Measurement 4 8 3 1 Optimizing dual sensor thickness Thickness measurements can present several challeng
14. s 20 4 7 1 Adjusting the Decimal PIACES iilia 20 4 7 2 Adjusting the Sample Rate 21 4 7 3 OE do ene een eee eee eee eee 21 4 7 4 CAlibia SS CNIS ONS aes cs coc secu iA EA E 21 4 8 Dual Sensors Configuration i 23 4 8 1 Connect the second laser SEnSor 23 4 8 2 Configure the TPD for two Sensors i 23 4 8 3 Configure the TPD to read thickness using two laser sensors 27 4 9 Using the RS485 Multipoint Output 29 5 Upgrading the TPD firmware e 30 Table of Figures Figure 1 Terminal blocks on rear of TPD 2 Figure 2 Function of individual RS232 terminal blocks 2 Figure 3 Mechanical Dimensions of TPD 5 Figure 4 Rear of TPD showing connection blocks for Sensor 1 and Sensor 2 7 Figure 5 Mating screw terminal connector 5 pin version 8 Figure 6 Connectivity Kit AQ700001 SNOWN 9 Figure 7 Wire connection to TPD terminal DIOCKS 9 Figure 8 Location of USB port to connect to a PC computer 30 Appendices Appendix 1 Acuity part model numbers chart 32 Acuity Touch Panel Display User s Manual 6 Revision 2 0 Acuity 1 Introduction 1 1 General Overview The Acuity Touch Panel Display TPD is a stand alone user interface f
15. screen When a user presses the Auto Zero button on the main display screen the displayed measurements reference a newly established zero point plus any programmed offsets typically none The Zero Reference Function is similar to a Tare function After a new zero point is established new measurements are shown as or that new zero point This function is helpful in showing relative measurements instead of absolute measurements When a user presses the Zero Off button on the main display screen while in the Zero Reference mode the TPD will return to the normal absolute sensor distance output plus any programmed offsets 4 5 Display Units This function is relevant to using the TPD with any Acuity sensor The default output units are the same as the default configuration for the particular sensor s It is possible to change the displayed output units by selecting between one of four units inches millimeters feet and meters To switch between these units press the Switch button in the Units area of the Settings screen 4 6 Setting Output Display Limits This function is relevant to using the TPD with any Acuity sensors The Limits menu allows users to change the color of the distance display font at different set points corresponding to levels of warning and criticality This color change serves as a visual cue to the TPD viewer that a threshold distance has been exceeded Above Upper Critical limit and Below the Lower
16. sensor model selection at the top of the screen To begin displaying the sensor output on the TPD Model AR 00 1 Press the Run Button Acuity Touch Panel Display User s Manual 11 Revision 2 0 Acuity Press the Laser On button Si lia pi laser Di Acuity become active and Lauer assure mani y Model AR700 1 The display screen will distance measurements O 1 O Q Q will appear if the laser E sensor is aimed ata RS Ri measurement span Once a sensor has been selected using the software as described in this section the TPD will restore the settings in use at the last session The TPD will display the measurement screen upon power up using the stored sensor settings The screen displays measurement results and a row of buttons at the bottom Touching the Laser Off button turns the sensor laser off and the TPD ceases displaying measurement values Touching the Laser On button turns the sensor laser On and the TPD begins displaying measurement values The central area of the screen is comprised of the sensors measured value a measurement scale and moving ball Position indicator within a scale both of which are displayed below the measured value The ball moves back and forth within the scale to simulate the position of the target distance relative to the sensor The second button displayed on the Measurement screen is the Setup button Touching the Setup button will display a screen with
17. Critical limit the font will be red Between the Critical and Warning limits the font will be pink Between the Upper and Lower Warning limits the font will be black Acuity Touch Panel Display User s Manual 17 Revision 2 0 Acuity Model AR4000 LV y Later Measurement The Main Display 4 h O Q QO O O Screen with measured Ww vl value within limits displayed in black in From the Settings Menu see section 4 1 The Settings Menu Access push the Limits button to access the Limits menu screen The Limits Screen displays each limit and allows users to enable or disable the function The Limits function is disabled in its default state so it is necessary to enable it by pressing the Enable radio button The parameters corresponding to Upper Critical Upper Warn Lower Warn and Lower Critical are set in an identical manner To set any of these limits press the corresponding button to access its individual setting screen Use the numeric keypad to enter the desired distance for the limit Acuity Touch Panel Display User s Manual 18 Revision 2 0 Acuity Laser Measurement Use the numeric keypad to enter the desired distance for the limit The units of the numerical value are the same as those chosen on the Settings menu screen and they take into account any offset that may be programmed Refer to Offsets Model AR4000 LV u Laser Measureme ty The Main Display Screen with
18. anel Display includes the following items e 1 Touch Panel Display unit including five terminal blocks for attaching wires to the rear panel e 2 meters of 5 conductor shielded cable This cable is 24 AWG and has a PVC jacket The cable is stripped and the ends of the wire leads are tinned e 1 threaded waterproof strain relief This strain relief is designed to fit Acuity Connectivity Kits e A Quick Start Guide e This User s Manual part number LLLOO9010 2 4 Mounting The TPD may be mounted in an electrical panel or free standing on a workbench When panel mounted with the attached foam gasket the unit is water resistant to NEMA 4X IP65 Use the mechanical drawing located in section 2 2 2 5 Laser Safety Although there are no lasers in the Touch Panel Display and therefore it requires no laser safety precautions this product is used with Acuity laser sensors Laser devices should not be aimed at the human eye Installers of laser sensors should follow precautions set forth by ANSI Z136 1 Standard for the Safe use of Lasers or by their local safety oversight organization 2 6 TPD Maintenance The Touch Panel Display requires little maintenance from the user The front screen should be kept clean of dust buildup as a part of regular preventative maintenance Use compressed air to blow off abrasive dust particles before wiping with a soft cloth If your TPD does not function according to specifications contact Schmitt Industries
19. bles the RS 485 output Acuity Touch Panel Display User s Manual 29 Revision 2 0 Acuity cuily The radio button BLK Sern in RS485 is used when the RS 485 is enabled and when the screen s display is not needed just the digital RS 485 output This allows for a faster digital RS 485 output signal Laser Alleate ment The Screen blackout function can improve the output speed of the RS485 communications by reducing the strain on the processor of the TPD 5 Upgrading the TPD firmware Acuity may change the firmware used in the Touch Panel Display to improve its functionality with Acuity sensors or to correct bugs Owners of TPD s may choose to upgrade the installed firmware to take advantage of the improvements offered in new revisions lt is not necessary to purchase a new TPD to obtain the new firmware version Instead it can be uploaded to the TPD device by connecting it to a PC computer Windows XP or Vista compatible via a USB cable not included Visit www acuitylaser com TPD tpd firmware update shtml to download the latest firmware version the custom installer program and instructions With the power to the TPD OFF plug a USB cable into the TPD and into a USB port on a PC computer Figure 8 Location of USB port to connect to a PC computer When power is restored to the TPD the USB communications are established and the PC computer will for the first time recognize the TPD as a new device In most cases
20. e sensor controls the exposure by varying the strength of the laser beam and the camera s shutter time For optimal speed performance the laser power is increased before the shutter time is increased Shorter exposure times generally occur with more reflective targets measurements that are closer to a sensor shorter range and with higher power lasers Longer exposure times generally occur with less reflective targets measurements that are farther from a sensor longer range and with lower power lasers When the exposure time is greater than the requested sample period then the priority command determines how the camera s shutter time is calculated In Quality Priority mode the sample rate may be slowed down from the programmed value in order to attain the optimum shutter time If the sample rate is Slowed then that rate is uncontrolled Acuity Touch Panel Display User s Manual 16 Revision 2 0 Acuity In Rate Priority mode the shutter time is limited in order to guarantee the programmed sample rate If the exposure is too low then the sample quality accuracy may be reduced If the shutter time is limited in this mode then there will only be only one scan cycle per sample no averaging 4 4 Zero Reference Function This function is relevant to using the TPD with any Acuity sensor The Zero reference setting is OFF in the default configuration of the TPD Switching to ON will place the Auto Zero button on the main display
21. ent AR 00 0125 Press the Select Model 2 button to setup the Select Model 2 second sensor you have connected to the TPD Select Model Select Mode Sn Select Model O Rao Select the sensor series from the screen listing di Lardo corresponding button Select the sensor model from the screen listing Acuity Touch Panel Display User s Manual 25 Revision 2 0 Acuity Laser Measurement bi i Model AR1000 da culty AR700 0125 Press the Run button to display the measurement Select Model 2 screen Select Model Select Mode Settings The display screen is now set to display the measured value of both laser sensors Press the Laser On button R 0 a 1 Q Q Both lasers values are displayed and if the Auto Zero Auto Zero function has been selected it is in independent to each laser ro 2 1 Acuity Touch Panel Display User s Manual 26 Revision 2 0 Acuity 4 8 3 Configure the TPD to read thickness using two laser sensors This section guides users through the necessary steps to configure the Touch Panel Display to perform the necessary mathematics to report dimensional information using the input from two Acuity laser sensors To read the proper dimension of an object placed between the two laser sensors it is necessary to program the TPD with the known thickness of a reference material This is accomplished by entering an offset equal the known thickness width etc
22. es that should be addressed to optimize the performance of the system in the measurement application For a full discussion of using laser sensors for thickness applications read our report at http www acuitylaser com resources synchronizing laser sensors shtml Acuity Touch Panel Display User s Manual 28 Revision 2 0 Acuity Users may choose to configure the TPD and the laser sensors to improve performance by increasing or decreasing the individual sampling speeds of the sensors Also data can be smoothed by averaging data samples through the to Average from the Rate and Calibration screen Depending on the individual sensor model selected the TPD may permit a Single Shot Mode from the Rate and Calibration screen 4 9 Using the RS485 Multipoint Output The RS485 block is a full duplex port with separate receive R R and transmit T T pairs The T T send the laser data using the physical RS485 RS422 signaling levels The TPD R R Pair are not functional for RECEIVING communications from an external device Once the RS485 connections have been completed and a digital output is needed The following screens are used to activate the RS485 output Later Measurement espe ars These radio buttons are used a when an RS 485 digital output signal is required and the display screen is not needed for monitoring ity Ladi Mibaeuird miaml The RS485 radio button when selected ena
23. f the offset are always the same units as the selected units This function can be used just as effectively with single or two lasers From the Rate amp Cal screen Press the Offset button to reach the Offset entry screen Using the virtual numeric keypad Enter the desired offset and Press Done to save the configuration 4 7 4 Calibrate Sensors The TPD Calibration function will force the device to display a desired value when an object of know distance or position is placed in front of a laser sensor Typically for short range laser sensors a guage block is placed in the path of a laser to force the known value The TPD calibration screens are easy to follow with on screen prompts Press either Calibrate 1 or Calibrate 2 button on the Rate amp Cal screen to enter the desired calibration setup A screen with virtual keypad is displayed prompting the first action of aiming the sensor at a home position Continue to follow these on screen prompts for a successful calibration Acuity Touch Panel Display User s Manual 21 Revision 2 0 Acuity Model AR700 1 AR 00 1 Laser hiaasure menti 0 4020 Aim the sensor at the home position the farthest distance you wish to measure Then Touch screen to continue Model AR 00 1 Laser Measurement 0 5084 Insert a gage block of known thickness Then Touch screen to continue y Model AR700 1 Laser Measurement b Enter the known A 2 3 gage block thickness Acu
24. four corner screws Remove the blind plug from entry hole see photo below Insert the extra wire harness Part number CBA901001 supplied with TPD through the hole and thread the strain relief hand tight into enclosure Insert the five individual wires into the terminal block as follows Acuity Touch Panel Display User s Manual 8 Revision 2 0 Acuity owe red o aa Shield wire from cable and Black from enclosure lug Figure 6 Connectivity Kit AQ700001 shown Pull the cable jacket back into the box of the Connectivity kit slightly then wrench tighten both parts of the strain relief starting with the inner portion first Insert the five wire leads into the terminal blocks of the TPD as shown below CBA901001 cable Brown TX Data White RX Data Green Data GND CBA901001 Cable Red 15VDC Black Ground Figure 7 Wire connection to TPD terminal blocks A second sensor can be connected to top RS232 Block on the TPD If using a Connectivity Kit the second cable needs only the three RS 232 conductors attached as shown connected to the second RS 232 port on the TPD Power connection to TPD is supplied only by the FIRST Connectivity Kit 3 3 RS485 Multipoint Output Connection The Acuity TPD includes a single RS485 interface designed for transmitting measured or calculated distance data as displayed on the screen to an external device The RS485 block is a full duplex port with separate receive R R and transmit T
25. four selections as seen in Acuity Touch Panel Display User s Manual 12 Revision 2 0 Acuity 3 5 Troubleshooting The TPD should display distances measured by the sensor to a target within the sensor s measurement span Trouble shooting steps are below Symptom Probable Cause The TPD does not turn on and or the welcome screen does not appear Distance readings do not appear on the display screen COMM ERROR is displayed No power to the TPD Improper voltage supplied to the TPD Power connections reversed The Acuity sensor is not connected The Acuity sensor does not have power The sensor is attached to the incorrect terminal blocks The Acuity sensor is connected to another terminal device The sensor is not aimed to a target in the span Communication error between sensor and TPD Verify that there is 12 24 Volts DC Supply and Ground attached to the two block terminal block on the rear of the TPD Try removing and re applying the supply power to cycle the TPD Attach the Acuity sensor according to Section 3 2 Supply the appropriate DC voltage to the sensor according to its specifications Be sure that your sensor is attached to the terminal blocks for Sensor 1 The sensor can only communicate with one device at a time the TPD or a computer but not both Aim the sensor s laser spot at a target within Its specified measurement span Press the Laser Off bu
26. ge 0 1 accuracy For use with reflective id ati tape included with RS 232 interface in NEMA 4 IP67 case Includes sensor 6 cables manual AR3000 amp AR1000 Model part model numbers AP1000232 AR1000 RS232 AR1000 laser distance sensor with RS232 output AP1000422 AR1000 RS422 AR1000 laser distance sensor with RS422 output AP3000232 AR3000 RS232 AR3000 distance measurement sensor with Asimo emi AP3000422 AR3000 RS422 AR3000 distance measurement sensor with Bled Asimo amadinet AP3100232 AR3000 RS232 AR3000 distance measurement sensor with BSS tom Asa fOmadieer o AP3100422 AR3000 RS422 AR3000 distance measurement sensor with AR700 Model part model numbers AP7010001 AR700 0125 AR700 0125 3 175 mm span 1 mW visible diode eet ONS Fn AP7010002 AR700 0250 AR700 0250 6 35 mm span 1 mW visible diode ee NS FE AP7010005 AR700 0500 AR700 0500 12 7 mm span 1 mW visible diode ee i Fn AP7010010 AR700 1 AR700 1 25 4 mm span 1 mW visible diode 83 eee OO meato a o o o AP7010020 AR700 2 AR700 2 50 8 mm span 1 mW visible diode 83 TR OOO mease meat AP7010040 AR700 4 1mW AR700 4 101 6 mm span 1 mW visible diode 83 ie mm case 2m cable Acuity Touch Panel Display User s Manual 32 Revision 2 0 Acuity AP7020040 AR700 4 5mW AR700 4 101 6 mm span 5 mW visible diode 83 mm case 2m cable AP7220060 AR700 6 AR700 6 152 4 mm span 5 mW visible diode SO O Emme EEE o AP7234060 AR700 6 RP AR700 6RP
27. ity Touch Panel Display User s Manual Revision 2 0 22 Aim the laser sensor at a reference surface Zero point This is typically a table surface or conveyor top Touch the screen Place an object of known dimension such as a gage block in front of the laser sensor Touch the screen Enter the thickness dimension of the gage block and press Done Acuity Laser Measurement cuity Model AR 00 1 6354 2500 Touch the screen to Calibration procedure complete complete the calibration Touch screen to continue If you are calibrating a second sensor repeat the previous steps after pressing the Calibrate 2 button for on the Rate amp Cal screen 4 8 Dual Sensors Configuration One the TPD s most powerful features is it s ability to accept inputs from two Acuity laser sensors simultaneously and automatically calculate target dimensions It is not necessary for two identical sensors to be connected to the TPD to exploit this functionality The most common application which uses two laser sensors is material thickness or material width based on two opposing laser sensors User s should understand the many considerations Information about the proper setup of opposing laser sensors can be found on the Acuity website at http www acuitylaser com resources synchronizing laser sensors shtml Prior to configuring the TPD to automatically calculate the material dimensions fixture both laser sen
28. may be necessary to change the number of significant digits to properly match the resolution of the particular Acuity sensor attached to the TPD See the Specifications data sheet for the sensor you are using to verify the proper resolution To change the number of decimal places and to access the Decimal Places menu screen press the Decimal Places button on the Rate amp Cal screen Use the numeric keypad to enter the number of significant digits to be displayed to the right of the decimal point and press Done when completed Acuity Touch Panel Display User s Manual 20 Revision 2 0 Acuity Model AR700 1 Laser Measurement Lalli att Enter the number of gi ee significant digits to be displayed to the right of the decimal point and press Done when completed 4 7 2 Adjusting the Sample Rate This function is relevant to using the TPD with any Acuity sensor The sampling rate refers to the number of distance samples transmitted by the sensor s serial interface to the TPD However the TPD may not adequately display the change in measurements at an equivalent speed due to processing refresh rate limitations By default the Sample Rate will be the same as the default sample rate setting for the sensor attached to the TPD In most cases this is 5 Hz or lower 4 7 3 Using an Offset An offset programmed into the Touch Panel Display will add or subtract if the number is negative the value to the displayed distance The units o
29. ndustries incorporated LICENSE a You are granted a personal nontransferable and non exclusive license to use the hardware and software in this Agreement Title and ownership of the hardware and software and documentation remain in Schmitt Industries Incorporated b the hardware and software may be used by you only on a single installation C you and your employees and agents are required to protect the confidentiality of the hardware and software You may not distribute disclose or otherwise make the hardware and software or documentation available to any third party d you may not copy or reproduce the hardware and software or documentation for any purpose e your may not assign or transfer the hardware and software or this license to any other person without the express prior written consent of Schmitt Industries Incorporated f you acknowledge that you are receiving only a LIMITED LICENSE TO USE the hardware and software and related documentation and that Schmitt Industries Incorporated retains title to the hardware and software and documentation You acknowledge that Schmitt Industries Incorporated has a valuable proprietary interest in the hardware and software and documentation YOU MAY NOT USE COPY MODIFY OR TRANSFER THE HARDWARE AND SOFTWARE IN WHOLE OR IN ANY PART WITHOUT THE PRIOR WRITTEN CONSENT OF SCHMITT INDUSTRIES INCORPORATED Acuity Touch Panel Display User s Manual 1 Revision 2 0 Acuity IF YOU
30. nsor parameters or both Model AR 00 1 Lasar culty 4 O Q Q Q To access the Settings E N menu press Setup on the display screen Select the Settings by pressing the Settings button ki y Model ARTON jb ssm aaaea i Enter the password Enter the Security Code 2468 and then press the Done button Acuity Touch Panel Display User s Manual 19 Revision 2 0 Acuity i Model AR700 1 Acuity e ar _ Le This is the main Settings screen After settings are adjusted press the Save button to return to the Modes screen 4 2 Background Light Elimination BLE Sample Priority is relevant to only AR200 and AR700 series sensors Background light Elimination is a feature on Acuity sensors whereby the sensor s detector will take a sample with the laser on and then with the laser off and automatically compensate for the effects of ambient light BLE default setting is ON for Acuity sensors The TPD allows user s to configure their sensor s BLE setting through the main Settings screen It is suggested that you leave BLE ON unless it becomes necessary to use the sensor at very high sampling rates Because two samples are captured for every one output the maximum frequency response of the sensor is halved 4 3 Sample Priority Sample Priority is relevant to only AR200 and AR700 series sensors Each sensor s scan cycle detector camera scan is checked for the correct exposure Th
31. or use with Acuity laser distance sensors These fully enclosed units replace panel meters alphanumeric displays and analog controllers by providing a modern interface through a full color LCD and touch screen The Touch Panel Display communicates with one or two Acuity sensors using their serial interfaces Sensors can be easily configured using on screen buttons to display and scale their distance outputs Relative dimensions can be measured using a tare function With dual RS232 serial inputs from two acuity sensors the Panel serves as a thickness gauge and display an application which previously demanded a PC computer and custom software programming Using a single RS485 serial interface the Panel can transmit thickness and dimensional information to external devices 1 2 Definition of Terms Sensor The complete distance measuring device It can refer to models AR200 AR700 AR1000 or AR3000 Target The object of measurement The relative distance from the sensor to the target is measured by the sensor TPD Touch Panel Display abbreviation 1 3 Quick Start Instructions This will get the Touch Panel Display operating for quick measurements using a single laser sensor to confirm proper system functionality Once the TPD and sensor are operational further detailed instructions can be found in the Acuity Touch Panel Display user s manual to assist the operator with learning the full capabilities of the Acuity AccuRangeTM system
32. seeesneeges 1 bo QUESITI 1 1 3 1 FOWEFCONNSCHIONS siae 2 1 3 2 Serial Communications CONNECHIONS ii 2 1 3 3 ACNAllGl nil 3 2 General Descriptio lea 4 2 1 Principles OF Operator esnemeyi neen ernia 4 2 2 Mechanical Dimensions 5 2 3 CON 6 2 4 EDURNE e E S EE E E E E 6 2 5 LAS ONO OLY ire e 6 2 6 TPD MQINIGANANce ein 6 3 Installation and Checkout i 7 3 1 MOUA ener a ciao 7 3 2 Cabling PRPRREE TASSE RR OS SCR RR RO SARE SI POE O ERRO CR ONE OTT 7 3 2 1 DIFCG GONNCCHOAS cinici oirredleipiania 8 3 2 2 Connections using the Connectivity Kit 8 3 3 RS485 Multipoint Output Connection 9 dA VO ODE O ea e E E NEN 10 3 4 1 Select the correct Model 10 3 4 2 RUMINER 11 3 5 Troubleshooting 13 3 5 1 Serial Communications Check 14 4 Performance Optimization using Settings 15 Acuity Touch Panel Display User s Manual 5 Revision 2 0 Acuity Laser Measurement 4 1 The Settings menu ACC CS Sas gata jesiccnsetieantnn cueeawectetstanehedaoesssueenoaeieaanmeaeumceniseads 15 4 2 Background Light Elimination BLE cccccesceceeeeeseeeeeeeeeeeeeseeeeeseeeeseeeens 16 4 3 DIDS FOU ana taste E EE EE 16 4 4 Zero Reference FUNCHION i 17 4 5 EIS OFA UR acidi 17 4 6 Setting Output Display LIMITS iii 17 4 7 Rate and Calibration SettiN
33. sor 1 and Sensor 2 Acuity Touch Panel Display User s Manual 7 Revision 2 0 Acuity 3 2 1 Direct connections For direct connection to a power source and an Acuity sensor please refer to the instruction in the Quick Start Guide Sections 1 3 1 and 1 3 2 The physical connections to the TPD are accomplished through two part Phoenix connector assemblies The male connectors on the rear of the TPD have the specifications in the below table Phoenix Contact P N Serial 232 3 pin 1803439 MCV 1 5 3 G 3 81 Serial RS422 485 5 pin 1803455 MCV 1 5 5 G 3 81 Power 2 pin 1803426 MCV 1 5 2 G 3 81 The mating female connectors have the specifications in the below table Phoenix Contact P N Serial 232 3 pin 1803581 MC 1 5 3 ST 3 81 Serial RS422 485 5 pin 1803604 MC 1 5 5 ST 3 81 Power 2 pin 1803578 MC 1 5 2 ST 3 81 Figure 5 Mating screw terminal connector 5 pin version 3 2 2 Connections using the Connectivity Kit The Acuity Connectivity kit is a housed connection terminal that makes it easy to connect the individual wire leads from Acuity sensors to an AC Power supply and a PC computer via a serial cable with DB9 connector The Connectivity kit includes a second set of terminal blocks making it possible to connect Acuity sensors to external devices such as the TPD electronic switches PLC s and networks To connect a sensor the TPD through a Connectivity Kit open the Connectivity Kit enclosure lid by loosening the
34. sors so that the emitted laser spots are aligned Separate the laser sensors to the desired positions 4 8 1 Connect the second laser sensor Physically attach the wire leads of the second laser sensor to the female terminal screw connector and attach the connector to the mating male connector for Sensor 2 on the rear of the TPD Apply the appropriate electrical power to the second laser sensor as well A second Acuity Connectivity kit can be used for the second sensor but it will not be necessary to draw a second power connection for the TPD 4 8 2 Configure the TPD for two sensors Apply power to the TPD and Touch the introductory screen to reach the main measurement screen It is assumed that the user has already configured the Acuity Touch Panel Display User s Manual 23 Revision 2 0 Acuity TPD for use with a single sensor These instructions are for the configuration of the TPD for use with second sensor in a thickness application At the display of the main measurement screen press the Setup button to reach the Settings menu I y Model AR700 1 EIIE are O Select Model _ Select Mode _ After press the Select Mode button Salar mi sasurement From the Mode menu Mode screen press the Two C Single Laser Laser radio button and then press Back E Thickness Two Lasers Acuity Touch Panel Display User s Manual 24 Revision 2 0 Acuity Laser Measurement cuity Model AR1000 Laser Measurem
35. t Industries Incorporated s entire liability and your exclusive remedy shall be L the replacement of any hardware and software not meeting Schmitt Industries Limited Warranty and which is returned to Schmitt Industries Incorporated or an authorized Schmitt Industries dealer with a copy of your purchase receipt or 2 if Schmitt Industries Incorporated or the dealer is unable within ninety 90 days to deliver a replacement product which is free of defects in material or workmanship you may terminate this Agreement by returning the product and your money will be refunded to you by the dealer from whom you purchased the product Acuity Touch Panel Display User s Manual 2 Revision 2 0 Acuity IN NO EVENT WILL SCHMITT INDUSTRIES INCORPORATED BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING ANY LOST PROFITS LOST SAVINGS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE SUCH PRODUCTS EVEN IF SCHMITT INDUSTRIES INCORPORATED OR AN AUTHORIZED DEALER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR FOR ANY CLAIM BY ANY OTHER PARTY SOME AREAS DO NOT ALLOW THE LIMITATIONS OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU GENERAL You may not sublicense assign or transfer the license or the hardware software and documentation except as expressly provided in this Agreement Any attempt otherwise to sublicense assign or
36. transfer any of the rights duties or obligations hereunder is void This Agreement will be governed by the laws of the United States and the State of Oregon United States of America Should you have any questions concerning this Agreement you may contact Schmitt Industries Incorporated by writing to Schmitt Industries Incorporated 2765 NW Nicolai St Portland Oregon 97210 USA YOU ACKNOWLEDGE THAT YOU HAVE READ THIS AGREEMENT UNDERSTAND IT AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS YOU FURTHER AGREE THAT IT IS THE COMPLETE AND EXCLUSIVE STATEMENT OF THE AGREEMENT BETWEEN YOU AND SCHMITT INDUSTRIES INCORPORATED AND ITS DEALER US WHICH SUPERSEDED ANY PROPOSAL OR PRIOR AGREEMENT ORAL OR WRITTEN AND ANY OTHER COMMUNICATIONS BETWEEN US RELATING TO THE SUBJECT MATTER OF THIS AGREEMENT Acuity Touch Panel Display User s Manual 3 Revision 2 0 Acuity Procedures for Obtaining Warranty Service 1 Contact your Acuity distributor or call Schmitt Industries Inc to obtain a return merchandise authorization RMA number within the applicable warranty period Schmitt Industries will not accept any returned product without an RMA number 2 Ship the product to Schmitt Industries postage prepaid together with your bill of sale or other proof of purchase your name address description of the problem s Print the RMA number you have obtained on the outside of the package This device complies with FCC Part 15 Class
37. tton followed by pressing the Laser On button This action should return the Acuity Touch Panel Display User s Manual 13 Revision 2 0 display to the sensor e SYNC is displayed Power may have been Apply proper voltage to disrupted to the sensor the sensor The sensor is not in range Aim the sensor at a target within its span A communication error occurred Press the Setup button followed by pressing the Run button Now press the Laser On button to reestablish communication with the sensor 3 5 1 Serial Communications Check If no information is received over the serial cable to the TPD check the power supply and serial wire connections The sensor may be in a configuration that prevents serial communication such as being set at the wrong baud rate To reset the sensor to the default follow the instructions for the sensor in question and configure the serial communications to the following parameters 9600 baud 8 bits no parity 1 stop bit and enable serial RS232 communication See the individual User s Manuals for your Acuity sensor to properly configure the device to these default settings Acuity Touch Panel Display User s Manual 14 Revision 2 0 Acuity 4 Performance Optimization using Settings 4 1 The Settings menu access The Settings menu allows the user to make several system configurations through the TPD Changes made through the various Settings Menu screens will affect the TPD the se