1746-SMPTE User`s Manual
Contents
1. Module I O Space 15 14 13 12 11 10 9 8 7 6 4 3 2 1 0 0 x x x x x Frame Rate Mode Mute Loop x Set Stop Run 1 Dropout Tolerance 2 Set Hours Set Minutes 3 Set Seconds Set Frames 4 Loop Start Hours Loop Start Minutes 5 Loop Start Seconds Loop Start Frames 6 Loop End Hours Loop End Minutes 7 Loop End Seconds Loop End Frames Module Output File The next two chapters contain complete descriptions of the function of each word in the Output File Bits marked x are reserved for future use They should always be set to zero Module 1 0 Input File The eight words in the input file indicate module status to the PLC 15 14 13 12 11 10 9 8 7 4 3 2 1 0 0 Hours 1 Minutes 2 Seconds 3 Frames 4 x x x x x Drop Gen Lock Frame Rate 5 Error Codes 6 X X X X X X X X X X X X X X T X X X X X X X X X X X X X X Module Input File The next two chapters contain complete descriptions of the function of each word in the Input File Bits marked x are reserved for future use They are all set to zero 6 Module I O Space Using the Module as a SMPTE Generator The 1746 SMPTE contains a very versatile SMPTE generator which has been designed for flexibility and ease of use With this generator one can easily accomplish many ta
2. Bit 0 10 Bit 0 9 Bit 0 8 30 fps 0 0 0 29 97 fps non drop 0 0 1 29 97 fps drop 0 1 0 25 fps 0 1 1 24 fps 1 0 0 23 976 fps 1 0 1 The other two codes 110 and 111 are reserved for future use Loop Start End Times When the SMPTE output reaches the Loop End Time it immediately jumps to the Loop Start Time if the LOOP bit is set or halts if the LOOP bit is clear Any invalid entries such as minutes greater than 59 will be treated as if the entry were zero An error bit will be set in the Input File to highlight the problem field SMPTE d o opam i co Z o O Loop Behavior If the LOOP bit is set one then when the SMPTE output reaches the Loop End Time the generator will jump to the Loop Start Time and continue generating from there If the LOOP bit is clear zero then the SMPTE output will stop at the Loop End Time Notice that by setting the Loop Start Time equal to the Loop End Time the module can be made to generate a continuous unbroken 24 hour long loop of time code Also the Loop Start Time need not be smaller than the Loop End Time Time code rolls over at 23 59 59 29 so the End Time will be reached eventually Mute Behavior If the MUTE bit is set one then the SMPTE output is muted Time code can continue to be generated internally but the output does not send the code Itis as if the cable has been unplugged If the MUTE bit is clear zero then the SMPTE output sends what
3. If the output time code has its drop frame flag set then this bit will be set If the output code is not a drop frame code then this bit will be clear Using the Module as a SMPTE Generator 11 12 Error Codes The bits in the error code word indicate invalid entries in the Output File Error Bit Entry Set Time Hours Set Time Minutes Set Time Seconds Set Time Frames Loop Start Time Hours Loop Start Time Minutes Loop Start Time Seconds Loop Start Time Frames Loop End Time Hours OloOIATLTNDI AJ AJS INe o Loop End Time Minutes Loop End Time Seconds Pami Loop End Time Frames 12 15 Reserved for future use Any invalid entry in the Output File will cause the corresponding bit in the error code word to be set one For example if the Loop End Time Minutes byte in the Output File contains a 63 which is an invalid number of minutes then bit 9 of the error code word in the Input File will be set Invalid entries in the Output File are treated as if the entries were zero Using the Module as a SMPTE Generator Typical Applications amp Sample Rungs In this example the 1746 SMPTE generates a short section of time code under the control of two external inputs to the PLC The PLC includes a 5 03 processor the Alcorn McBride 1746 SMPTE module and a simple input module 140 Configuration r Racks 1 1746 44 4 Slot
4. Off Off Off Off Off Off 3 5 Vpp Off On Off Off Off Off Off Off 3 0 Vpp Off Off On Off Off Off Off Off 2 5 Vpp Off Off Off On Off Off Off Off 2 0 Vpp Off Off Off Off On Off Off Off Output Level Module Power Consumption The 1746 SMPTE module draws a maximum of 0 350 Amps at 5 VDC The module does not use the 24 VDC power supply Installing the 1746 SMPTE 3 Module Setup Installing the Module in the SLC 500 Chassis Attention Never install or remove any module while power is applied Installing the Module Align the module circuit board with the card guides in the chassis Gently push the module in until it is firmly seated with the retaining clips engaged at the top and bottom Removing the Module Press the retaining clips at the top and bottom of the module and slide the module straight out of the chassis Wiring the Module Attention Never wire any module while power is applied The module wiring terminals accept two wires per terminal maximum of 14 AWG or smaller stranded wire Maximum screw torque is 8 in lb The module terminal block is removable Simply unscrew the upper right and lower left release screws and pull the entire terminal block straight out When replacing the terminal block alternate the tightening of the release screws to avoid cracking the block Maximum screw torque is 8 in
5. SMPTE Time Code is often used to synchronize various elements of a complex presentation Equipment such as film projectors video sources audio systems lighting consoles and motion controllers can read the time code to remain at the proper point in the show at all times The 1746 SMPTE brings the ability to read and generate SMPTE EBU time code to the Allen Bradley family of programmable logic controllers The module is compatible with all processors in the SLC 500 family including the 5 01 5 02 5 03 and 5 04 processors Technical Support You can obtain information about specifying installing configuring and programming your Alcorn McBride 1746 SMPTE from several sources For Contact When Telephone Support 407 296 5800 M F 9am 6pm EST Fax Support 407 296 5801 M F 9am 6pm EST E Mail Support support alcorn com Any Time 2 Welcome Installing the 1746 SMPTE The Alcorn McBride 1746 SMPTE plugs directly into a standard SLC 500 PLC chassis The module is compatible with all SLC modular processors including the SLC 5 01 5 02 5 03 and 5 04 Setting the SMPTE Output Level If the module is being used to generate SMPTE time code set the SMPTE time code output level before installing the module in the chassis The 1746 SMPTE includes one eight position switch labeled SW1 on the circuit board to select the output level measured in volts peak to peak Switch SW1 Settings 1 2 3 4 5 6 7 8 4 0 Vpp On Off
6. Rack x 2 fizo Rack Not Installed z 3 1 0 Rack Not Installed F r Auto Online Config System Comms Read I0 Config E w PowerSupply m 5 2 c p H o 5 03 CPU 12K Mem 05300 O 1 OTHER 120 Module ID Code 3535 2 1746 1416 16 Input 100 120 VAC 3 Adv Config Help Using the Module as a SMPTE Generator 13 14 oaoa ooo When the PLC switches to run mode the first pass bit S2 1 15 causes the following rungs to execute Rung 0000 sets the generator s fundamental operating parameters in word 0 of the output file The value 128 causes bit 7 of word 0 to be set and all other bits to be clear Bit 7 is the operating mode setting this bit configures the module to generate time code Bits 10 8 determine the frame rate the code 000 represents 30 frames per second Bit 4 controls looping clearing this bit causes the generator to stop when it reaches the end time Rung 0001 initializes the SET TIME to 01 00 00 00 Initialization Tasks Configure the 1746 SMPTE to generate 30 frame time code First Pass 52 1115 Moy J E Move Source 128 128s Dest G10 128 lt The SET TIME vill be 01 00 00 00 First Pass SET_TIME_H M S2 1 15 Mov J E Move Source 256 2562 Dest Ola 256 lt SET_TIME_3 F Moy Move Source 0 Os Dest O13 Oe Using the Module as a SMPTE Generator Continuing the initialization tasks rungs 0002 and 0003 set the LOOP S
7. find that it makes your PLC programming job a little bit easier Using the Module as a SMPTE Reader
8. time code Dropout Tolerance If incoming SMPTE time code drops out or becomes corrupt the 1746 SMPTE will flywheel or self generate time code to cover the gap The DROPOUT TOLERANCE word sets how many frames of self generation are allowed before the unit stops self generating and goes IDLE A setting of zero frames selects infinite tolerance the unit will never stop self generation Using the Module as a SMPTE Reader Frame Rate The SMPTE frame rate is automatically determined from the incoming time code The three bit Frame Rate field in the PLC Output File is ignored Set Time Loop Start Time Loop End Time These words are ignored by the SMPTE reader Set Bit Loop Bit These bits are not used by the SMPTE reader Controlling the Reader The 1746 SMPTE reader regenerator is entirely controlled by words in the PLC Output File See the Module I O Space chapter for a diagram of the Output File Note The 1746 SMPTE samples the control bits in the output file once per frame Control pulses of less than 33 milliseconds duration may not activate the module reliably Starting the Reader Whenever the RUN bit transitions from a zero to a one the reader begins searching for incoming time code If the reader is already running the rising edge on the RUN bit has no effect When the operating mode is switched from generate to read or upon entering read mode on powerup the module automatically begins searching for incoming t
9. 1746 SMPTE User s Guide by Alcorn McBride Inc Document Revision 1 0 September 1997 Copyright 1997 Alcorn McBride Inc All rights reserved Every effort has been made to assure the accuracy of the information contained in this manual and the reliability of the hardware and software Errors sometimes can go undetected however If you find one please bring it to our attention so that we can correct it for others Alcorn McBride Inc reserves the right to make changes to these products without notice in order to improve their design or performance Applications described herein are for illustrative purposes only Alcorn McBride Inc assumes no responsibility or liability for the use of any of these products and makes no representation or warranty that the use of these products for specific applications will be suitable without further testing or modification Our Show Control equipment is not intended for use in applications where a malfunction can reasonably be expected to result in personal injury or damage to equipment Customers using or selling Alcorn McBride Inc products for use in such applications do so at their own risk and agree to fully indemnify Alcorn McBride Inc for any damages resulting from such improper use or sale The 1746 SMPTE incorporates technology which is licensed from Allen Bradley Company Inc Allen Bradley has not technically approved nor does it watrant or support the 1746 SMPTE All warranty a
10. PTE generator follows a simple process to generate time code Each frame the module performs these tasks 1 Convert the current time to a string of 80 bits and if the generator is not muted send those bits out the SMPTE output If the STOP bit has changed from a zero to a one switch the generator from RUNNING to IDLING If the RUN bit has changed from a zero to a one switch the generator from IDLING to RUNNING If the SET bit has changed from a zero to a one replace the current time with the user s new time code otherwise add one frame to the current time if running or leave the current time unchanged if idling If the current time matches the Loop End time replace the current time with the Loop Start Time if the Loop bit is set one or switch from RUNNING to IDLING if the Loop bit is clear zero If the unit is idling and the MUTE bit is set mute the SMPTE output Make the time code available to the PLC through the Input File Configuring the Generator The 1746 SMPTE generator is entirely controlled by words in the PLC Output File See the Module I O Space chapter for a diagram of the Output File Operating Mode When the MODE bit is set one the module will generate SMPTE time code internally When this bit is clear zero the module will read external SMPTE time code Using the Module as a SMPTE Generator Frame Rate The generated SMPTE frame rate is determined by this 3 bit field
11. TART TIME and the LOOP END TIME The LOOP START TIME wall also be 01200 0000 First Pass LOOP_START_TIME_H M 2115 Moy oooz Move Source 256 2565 Dest O14 2565 LOOP_START_TIME_ F Moy Move Source o O Dest 0 1 5 Os p The LOOP END TIME vall be 01 00 05 00 Lu 2 First Pass LOOP_END_TIME_H M zx h S215 MOY 3 0003 q E Move O 5 Scarce 236 0 2566 Dest 0 16 256s LOOP_END_TIME_ F MOY Move Scarce 1280 1280 Dest Ol 12805 Using the Module as a SMPTE Generator 15 16 a004 agos agog ooo Once the PLC is running rungs 0004 and 0005 continuously test two input bits and link them to the 1746 SMPTE RUN and STOP controls These inputs can be used to give external equipment direct control over the SMPTE generator s operation Rung 0006 monitors the generate status bit in the 1746 SMPTE input file to activate the SET control whenever the generator stops producing time code This means that every time the generator stops it is automatically reset to the SET time Operating Tasks Link tao inputs to the generators RUN and STOP controls RUN 1 2 0 O10 eee C STOP ail Oli ee C Every time SMPTE stops automatically reset to 01 00 00 00 the SET TIME GEN SET 1 173 Ole oe eA END Using the Module as a SMPTE Generator Using the Module as a SMPTE Reader The 1746 SMPTE contains a robust SMPTE reader regenerator which ha
12. a SMPTE Generator Monitoring the Status of the Generator The 1746 SMPTE generator communicates its status to the PLC through the Input File See the Module I O Space chapter for a diagram of the Input File Current Time The current output SMPTE time code is always available through four words in the PLC Input File Word 0 hours will always be between 0 and 23 inclusive Word 1 minutes will always be between 0 and 59 inclusive Word 2 seconds will always be between 0 and 59 inclusive Word 3 frames will always be between 0 and 29 inclusive Note Word 3 frames can change 30 times per second This could impact your programming technique if your program s scan time exceeds 33 milliseconds Current Frame Rate The low byte of word 1 in the Input File always contains the number 24 25 or 30 to indicate the frame sequence of the output time code For example 24 frame time code always rolls over from frame number 23 to frame number 0 No distinction is made between 23 976 and 24 frame rates or between 29 97 and 30 frame rates Locked This bit will always be clear zero when generating time code It is used only by the SMPTE reader to indicate incoming time code lock SMPTE i i co Z o O Self Generating Whenever the internal SMPTE generator is running this bit in the Input File is set one If the internal generator switches into idle mode this bit will be cleared Drop Frame
13. de the first pass bit S2 1 15 causes the following rung to execute The rung sets the reader s dropout tolerance to 90 frames Initialization Tasks Configure the Dropout Tolerance to 90 frames First Pass DROPOUT _TOLERANCE S2 115 Moy Ov pe Move Using the Module as a SMPTE Reader 21 000l opoz 0003 22 Once the PLC is running the following rungs continuously test the incoming SMPTE code for specific times When those times occur an output bit becomes energized rung 3 or deenergized rung 4 This output bit could be used to trigger the execution of additional rungs or could simply activate some device external to the PLC Notice that the RUN control bit O 1 0 was not needed in this example The 1746 SMPTE automatically entered RUN mode upon startup Also notice that this program s scan time is fast enough to easily handle the rapidly changing frames word Operating Tasks Energize the output when the SMPTE time becomes equal to 2 17 35 xx HOURS MINUTES SECONDS EQU EQU Equal Equal Source A 1 1 0 Source A I 1 1 0 lt 0 Source E 2 Scume B 17 2s 17s Deenergize the output when the SMPTE time becomes equal to xx xx 40 20 SECONDS FRAMES EQU EQU o a Equal Equal ci Source A Ela Source A 1 15 O O Source B 40 Source 20 40 lt 20 lt END Thanks for purchasing the Alcorn McBride 1746 SMPTE module We hope you ll
14. ever time code is being produced internally Dropout Tolerance Only the SMPTE reader uses this word It may be set to any value when generating time code the module will ignore it entirely Using the Module as a SMPTE Generator 9 Controlling the Generator 10 The 1746 SMPTE generator is entirely controlled by words in the PLC Output File See the Module I O Space chapter for a diagram of the Output File Note The 1746 SMPTE samples the control bits once per frame Pulses of less than 33 milliseconds will not activate the module properly Setting the Current Time Whenever the SET bit transitions from a zero to a one the SMPTE time in the Set Time words will be loaded into the SMPTE generator s output The load occurs at the next frame edge so the time can be altered while the generator is running or while it is idling Any invalid entries such as minutes greater than 59 will be treated as if the entry were zero An error bit will be set in the Input File to highlight the problem field Starting the Generator Whenever the RUN bit transitions from a zero to a one the generator switches from IDLING to RUNNING If the generator is already running the rising edge on the RUN bit has no effect Stopping the Generator Whenever the STOP bit transitions from a zero to a one the generator switches from RUNNING to IDLING If the generator is already idling the rising edge on the STOP bit has no effect Using the Module as
15. ime code It is not necessary to activate the RUN bit in this case Stopping the Generator Whenever the STOP bit transitions from a zero to a one the reader stops searching for incoming time code and the internal generator goes idle If the reader is already inactive the rising edge on the STOP bit has no effect Mute Behavior If the MUTE bit is set one then the SMPTE output is muted Time code can continue to be received but the output does not retransmit the code It is as if the output cable has been unplugged If the MUTE bit is clear zero then the SMPTE output sends a regenerated copy of whatever time code is being received Using the Module as a SMPTE Reader 19 SMPTE Reader Monitoring the Status of the Reader 20 The 1746 SMPTE reader regenerator communicates its status to the PLC through the Input File See the Module I O Space chapter for a diagram of the Input File Current Time The current incoming SMPTE time code is always available through four words in the PLC Input File Word 0 hours will always be between 0 and 23 inclusive Word 1 minutes will always be between 0 and 59 inclusive Word 2 seconds will always be between 0 and 59 inclusive Word 3 frames will always be between 0 and 29 inclusive Note Word 3 frames can change 30 times per second This could impact your programming technique if your program s scan time exceeds 33 milliseconds Current Frame Rate The low byte of
16. l Applications amp Sample Rungs essseseseesessessesesrestsrertereereresreresresreserreresseneeseresesetee 13 Using the Module as a SMPTE Reader 17 Reader Theory of Operations reran niii a aa e AA soa neg pie eeii 17 Configuring the Reader sienien oaeee kan a o Sneis eeh lela ligdegcaplepcenoehvenenteeedeodedbaned 18 Controlling the Readet oar erea aai eai a aasa e eean A E aa a EER OE E EESE DETENTOR 19 Monitoring the Status of the Reader seseeseessesesseseesesessesrertererrereerereerererresrererresessesesseseseseese 20 Typical Applications amp Sample Rungs essseseseesseseseesesresteresrereererestertsresesserrenessesssesesesetse 21 Welcome Since the first V16 was introduced in 1986 Alcorn McBride has been providing high quality show control solutions to the entertainment industry The 1746 SMPTE module brings that same power to the Allen Bradley family of programmable logic controllers We at Alcorn McBride are pleased to provide you with these tools Good luck have fun and thanks for choosing Alcorn McBride What is SMPTE Time Code Think for a moment about any recorded performance It could be a stereo recording of a symphony orchestra a video of your child s birthday party or your favorite motion picture It would be very desirable to know the length of the performance and to be able to jump in to any point in the recording accurately Early systems provided such capabilities by linking a mechanical coun
17. lb SMPTE Input When the 1746 SMPTE is used to read external time code the signal is connected to this input The input is transformer balanced with a 600 ohm characteristic input impedance and can accept signals from 2 Vpp to 5 Vpp Connect the positive drive to the terminal labeled IN and the negative drive to the terminal labeled IN There is no terminal for the cable s shield it should be connected to the chassis ground at the other end of the cable SMPTE Output When the 1746 SMPTE is used to generate or regenerate time code the signal comes out of this output The output is transformer balanced to drive a 600 ohm load and can output signals from 2 Vpp to 4 Vpp as selected by switch SW1 Connect the terminal labeled OUT Y to the positive drive and the terminal labeled OUT to the negative drive There is no terminal for the cable s shield it should be connected to the chassis ground at the other end of the cable 4 Installing the 1746 SMPTE Module I O Space The 1746 SMPTE module uses ID code 3535 which indicates that it is a Class 1 module with I O mix of 8 input words and 8 output words and I O type of third party All communications with the 1746 SMPTE takes place through the Output and Input Data Files The module occupies eight words in the Output File and eight words in the Input File Output File The eight words in the output file configure and control the SMPTE module
18. nd support for the 1746 SMPTE and its application is provided solely by Alcorn McBride Product Design Jim Janninck Jason Crew and Steve Alcorn Documentation Jim Janninck Alcorn McBride Inc Alcorn McBride Inc 3300 S Hiawassee Suite 105 Orlando Florida 32835 407 296 5800 FAX 407 296 5801 http www alcorn com info alcorn com Contents Welcome 1 Whatis SMPTE Time Code 2 2 s te aie eens E E a a ae aea 1 Technical Supports ee ee ait baehectestepSeennsayee hte eal heaping RTA LA tia aes 2 Installing the 1746 SMPTE 3 Setting the SMPTE Output Levels iien nied aa a E de 3 Module Power Consumption ceececsseseececcseessecsecceeescesseceecaeesaeesecsecaeesaeeeecseesseeeseeeeneeeaees 3 Installing the Module in the SLC 500 Chassis ceessescssesseceeceseeeeceeceseceecsaeeseceecsaeeseseneaees 4 Waring the Modules chav ava fa dcieet die di aivaraasslsiistal ala dit A N aE 4 Module I O Space 5 Output PS desae ee a a E E E A RA a decee ete EE lap N EE REE EES 5 InputsPileatscs vate ici otra cael Macttds Masts Pads slosdish EEA EEA E EN EEE nee 6 Using the Module as a SMPTE Generator 7 Generator Theory Of Operation see 5 ius cases sciseascieven a eiae aiaiai ereitte pues anced J Confisurins the Gen erator r a AA a AS a E E AS 8 Controlling the Generatore on hinipo cote a aaea ahai a e eSa 10 Monitoring the Status of the Generator seeeseeseseeseesesestserrererrereeretterererstteteeretreesensesrees 11 Typica
19. s been designed for flexibility and ease of use e Read external SMPTE time code at all common frame rates e Automatically detect changes in frame rate e Regenerate fresh time code from a noisy or partially corrupted source e Flywheel through dropouts in the incoming time code with adjustable tolerance Reader Theory of Operation Whenever the 1746 SMPTE is in read mode it constantly searches for valid incoming time code As soon as two consecutive valid frames arrive the reader locks its internal generator to the incoming code As long as the incoming code remains valid the generator remains in lock The reader constantly tests the incoming time code to be sure it remains good This means that each frame must contain 80 good SMPTE bits and also the time code must be rolling forward one frame at a time or must be idling no change in frame number If the incoming time code becomes corrupted the internal generator will continue to produce time code through the dropout The theory is that when good external code returns the internal generator will still be in sync the bad portion of the signal has been effectively eliminated If the external SMPTE returns and it does not match the internal generator the internal time code will be locked to the external code after two consecutive valid frames arrive The dropout tolerance governs how long the internal generator will function in the absence of good external time code If the ex
20. sks e Produce SMPTE time code at all common frame rates e Roll time code from a start point to an end point e Create an automatic loop of time code that will continue running without further intervention SMPTE d o opam i co Z o O e Create jumps or discontinuities in the time code Generator Theory of Operation The SMPTE generator is always active in order to produce an internal frame clock Every frame the time code output advances by one frame if the generator is running or remains unchanged if the generator is idling When the generator is idling the output can be muted to prevent transmitting the same SMPTE code over and over The generator constantly compares the SMPTE output to the user s Loop End Time contained in the Output File When the current time reaches the Loop End time the generator will automatically jump to the Loop Start time or halt depending on the setting of the Loop bit The jump can be disabled by simply setting the Loop Start time equal to the Loop End time In this case the generator will either keep running or stop at the Loop End Time depending on the setting of the Loop bit The output time code is always available to the PLC through the Input File The PLC can use this information to trigger execution of rungs or to reload the SMPTE generator at a specific time to create a controlled jump in the time code output Using the Module as a SMPTE Generator 7 The SM
21. ter to the tape or film reels By counting revolutions of the reel one could return to the same point in the recording repeatably and get some sense of the overall length of the piece Mechanical or electronic counters work very well In fact they are still in widespread use in much of today s audio and video equipment However they do have drawbacks such as the lack of consistency from one machine to another and the fact that the counts can change when the tape gets edited or copied A far more accurate system would encode the time information as a part of the presentation itself perhaps as an additional track of a multi track audio recording This is exactly the technique that was standardized in 1981 by the Society of Motion Picture and Television Engineers SMPTE and subsequently adopted by the European Broadcast Union EBU The complete standard was published as ANSI V98 12M 1981 and is generally known as the SMPTE EBU Longitudinal Time Code or more simply SMPTE Time Code To achieve film like editing capability SMPTE Time Code represents time in hours minutes seconds and frames The common frame rates are 24 frames per second for film work 25 frames per second for European television 30 frames per second for NTSC black and white television and 29 97 frames per second for NTSC color television A typical SMPTE readout looks like 02 28 35 15 indicating 2 hours 28 minutes 35 seconds and 15 frames Welcome 1 Welcome
22. ternal code drops out for more frames than the dropout tolerance setting the internal generator goes into idle until good external code is restored Using the Module as a SMPTE Reader 17 SMPTE Reader The regenerated time code is always available to the PLC through the Input File The PLC can use this information to trigger execution of rungs The SMPTE reader performs the following tasks each frame 1 Receive and decode incoming SMPTE bits 2 Verify that the received code matches the previously received code or is one frame greater than the previously received code 3 Automatically detect the frame rate of the incoming code 4 Lock the internal SMPTE generator to the received code s frame edge 5 If the incoming code has dropped out advance the internal generator by one frame 6 If the signal loss has lasted longer than the dropout tolerance stop the internal generator 7 Make the current internal time and frame rate available to the PLC through the Input File 8 Indicate external lock and internal generate status to the PLC through the Input File Configuring the Reader 18 The 1746 SMPTE reader regenerator is entirely controlled by words in the PLC Output File See the Module I O Space chapter for a diagram of the Output File Operating Mode When the MODE bit is set one the module will generate SMPTE time code internally When this bit is clear zero the module will read and regenerate external SMPTE
23. word 1 in the Input File always contains the number 24 25 or 30 to indicate the frame sequence of the incoming time code No distinction is made between 23 976 and 24 frame rates or between 29 97 and 30 frame rates Locked When the received time code is valid this bit in the Input File is set one If the received time code drops out or becomes corrupt this bit is cleared Self Generating Whenever the internal SMPTE generator is running this bit in the Input File is set one If the internal generator switches into idle mode this bit will be cleared Drop Frame If the incoming time code has its drop frame flag set then this bit will be set If the incoming code is not a drop frame code then this bit will be clear Error Codes The bits in the error code word indicate invalid entries in the Output File time fields The SMPTE reader does not produce any additional error codes See the Generator chapter for a complete description of the error codes Using the Module as a SMPTE Reader Typical Applications amp Sample Rungs This PLC includes a 5 03 processor the Alcorn McBride 1746 SMPTE module and a basic relay output module 140 Configuration BBE Racks r Auto Online Config 1 1746 44 4 Slot Rack x System Comms 2 fizo Rack Not Installed z Read I0 Config 3 120 Rack Not Installed PowerSupply 3 Adv Config Help SMPTE Reader When the PLC switches to run mo