Home

1170 Installation Guide

image

Contents

1. UP arrow Align the 4 studs with the 4 keyhole slots and hang the 1170 on the bracket in any of 4 rotation orientations Connect power and system cables and turn on the 1170 11933017 Rev A 8 2015 UTC RETAIL All rights reserved CONFIGURATION COM SETUP The configuration of the I O lines of COM2 may be modified from standard RS232 Use the 1170 User Manual to review motherboard terminal block settings MINI PCIE SLOT OPTIONS The mini PCle slot can hold an optional WLAN card Use the 1170 User Manual to find details HARD DRIVE REMOVAL Use the 1170 User Manual for details on accessing the HDD Please call UTC RETAIL s Technical Support at 800 349 0546 if you have any problems not addressed in the Troubleshooting Procedures or has questions about other sections of this documentation 11933017 Rev A 9 2015 UTC RETAIL All rights reserved
2. Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense WARNING CMOS Battery Damage Replace your system s CMOS RAM battery only with identical CR 2032 3V Lithium Ion coin cell or equivalent battery type to avoid risk of personal injury or physical damage to your equipment Always dispose of used batteries according to the manufacturer s instructions or as required by the local ordinance where applicable The damage due to not following this warning will void your motherboard s manufacture warrantee All access to internal components is restricted to Authorized Service personnel only If applicable the key for this device should be in the possession of Qualified Service Personnel Only and used for access by an Authorized and Qualified Service Person 11933017 Rev A 2 2015 UTC RETAIL All rights reserved CONTENTS UO FOS System ts Ca Oh es T 2 Preparing tor Meal TTT 4 Baty Pre CUO MS 2s cdaaetce den caandet E E E tevaadedsdcanbandensmonanes 4 Site Specif
3. SOFTWARE HARDWARE SERVICE UTC RETAIL 1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution This Installation Guide will help you efficiently install the 1170 POS The document is intended for use by technical experts who assemble POS systems 2015 UTC RETAIL All rights reserved 11933017 Rev A 1170 POS SYSTEM INSTALLATION GUIDE All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic or mechanical including photocopying recording or otherwise without the prior written permission of UTC RETAIL This Installation Guide was prepared by UTC RETAIL for use by Qualified Service Personnel only All attempts have been made to ensure that the information presented in this manual is correct No liability expressed or implied will be assumed by UTC RETAIL its dealers or affiliates for damage resulting from the use of this information If a unit needs to be shipped to UTC RETAIL for repairs please return it in the original packaging material and shipping container If you purchased the 1170 POS System through a dealer and the dealer is unable to answer your questions please call UTC RETAIL Technical Support at 1 800 349 0546 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC
4. at can be sized for your system contact your UTC RETAIL representative for information PRODUCT INFORMATION 1170 POS SYSTEM COMPONENTS You will find the following components inside the 1170 POS System box e 1170POS e Vertical Stand e Safety Sheet e VESA mount bracket e A C adapter and power cord e Hardware bag Note Options that were purchased from UTC RETAIL such as a keyboard customer display and printer may be shipped in separate boxes 11933017 Rev A K 2015 UTC RETAIL All rights reserved PERIPHERAL SUPPORT e The 1170 POS System accepts a standard PC keyboard and standard mouse with a PS 2 or USB interface UTC RETAIL P N 10718020 contains both a USB keyboard and USB mouse e The 1170 POS System was designed to coordinate with the UTC RETAIL PD1200 Pole Display option e The 1170 POS System supports many different printers such as the Epson H6000 or TM T88 e The 1170 POS System supports UTC RETAIL 15 flat panel LCD displays The displays are available in touch screen and non touch configurations USER GUIDE To view or download the 1170 POS User Guide go to www utcretail com INSTALLING THE 1170 POS WORKSTATION POWER CORD Plug the AC cord into AC adapter and mate the adapter s barrel plug with the power jack in the rear of the chassis Lay the system on the countertop and route the power cables so they does not interfere with the system s operation FRONT I O PANEL 1 Power switch amp LED 3 Audio O
5. equivalent battery type to avoid risk of personal injury or physical damage to your equipment Always dispose of used batteries according to the manufacturer s instructions or as required by the local ordinance where applicable The damage due to not following this warning will void the warranty on this product AN To avoid accidental power up during POS installation connect the AC Power Cable last AN To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports use RJ 45 connectors Use caution when connecting cables AN Damage to the computer s motherboard components may occur if AC power is not removed from the unit prior to attaching any peripherals or accessories Do not hot plug to the serial ports turn off the POS before connecting serial port cables AN If this POS contains a WLAN accessory This POS complies with FCC radiation exposure limits for an uncontrolled environment The POS should be installed and operated at a distance greater than 20 centimeters 8 inches between yourself and any bystander to comply with the Radiation Exposure Requirements Changes or modifications not expressly approved by UTC RETAIL could void your authority to operate the POS 11933017 Rev A 4 2015 UTC RETAIL All rights reserved SITE SPECIFICATIONS AND POWER REQUIREMENTS Frequenc
6. ications and Power Requirements oxic ssicrsccaraccnncaoveced ssagebecssnenddeenacoeseaseudaddernsebacatmenddeabacsederadededdusnedbecaeecness 5 AC Power Line and Data Line Transient Protection sese 5 ROE O A O E E E E E 5 IFO POS System ComponehiS T 5 SNS STR a p e E qeeeabiesnetvannestecenerautbensaune 6 U E a r E A A E NEN A EO A N AA A O N E 6 Instalime the B KT POS WOKS CaO sesionin Ee E a E A 6 POR TE O arias eon ott ced net pati ate AEE A E E A EE E E EES 6 Fy OT ANG eair A A E E A A A E EA EEA EE EA EAA EE 6 PVOP Ae a E E EE an seneoasencncenceacestastadacte 7 Dy SSP a O oi E E E N A maoetestanihietnecase 7 LOR IZO T EENE P ETE A A TE eset eae asses E ENEN E E N A E E I Kas ETE N AI ace VE E N T N I A S E T I ent S E A NAA N A AT NE A T NT 7 LOVE AMONI e E E E E E E 8 Conr TTT 9 CONES TTT 9 TETE R T Te R Ee EEE E E E A T EE E A A A E E soe eesetaiues 9 Pard Drive OO e E E E E OA 9 11933017 Rev A 3 2015 UTC RETAIL All rights reserved PREPARING FOR INSTALLATION SAFETY PRECAUTIONS AN This unit contains high voltage There is a risk of electrical shock if the case is opened If service is required contact UTC RETAIL UTC AN All access to internal components of the POS unit is restricted to Authorized Service Personnel only Opening the case or service by anyone else will automatically void the warranty on this product AN Replace your system s CMOS RAM battery only with the identical CR 2032 3V Lithium lon coin cell or
7. utput 5 USB 2 0 2 HDD activity LED 4 Microphone Input 6 USB 3 0 Review the 1170 POS User Guide for more information on these I O ports 11933017 Rev A 6 2015 UTC RETAIL All rights reserved REAR I O PANEL 1 Kensington Lock 7 HDMI 13 LAN U 2 AC Adapter 8 COMI 14 USB 2 0 3 PS 2 mouse 9 COM2 15 USB 2 0 4 PS 2 keyboard 10 LAN 1 16 WLAN dipole 5 Parallel 11 USB 2 0 6 DVI 12 USB 2 0 Review the 1170 POS User Guide for more information on these I O ports SYSTEM ORIENTATION The 1170 POS versatility can be seen in the various available mounting orientations HORIZONTAL This orientation is seen in the image on the manual s cover page Place the 1170 POS flat on the table or counter top Connect power and system cables and turn on the 1170 VERTICAL Remove the vertical stand bracket from the system box Align the tabs on the bracket with the slots in the 1170 POS chassis right side Slide the stand forward until you feel the stand lock into place Stand the 1170 POS on the countertop Connect power and system cables and turn on the 1170 To remove the stand gently and slightly push in the release tab and slide the stand rearward chee aos Ee i 2015 UTC RETAIL All rights reserved LCD VESA MOUNT Remove the VESA bracket and hardware bag from the system box Install the 4 studs onto the bottom side of the 1170 Install the VESA bracket onto the rear of your LCD using the 4 screws and observing the
8. y 50 60 Hz Current adapter s max output 3 42A A dedicated unswitched power line is recommended The AC outlet should be close to the 1170 POS Do not use extension cords Temperature Constant operation at or near the temperature limits stated below should be avoided Do not exceed the limits shown Operating temperature 0 C to 40 C 32 F to 104 F Storage temperature 20 C to 60 C 4 F to 140 F Humidity Constant operation at or near the humidity limits stated below should be avoided Do not exceed the limits shown FG Humidity Up to 90 non condensing Airflow Requirements The ambient air temperature must not exceed 40 C 104 F Do not block the air vents on any side of the 1170 POS Workstation Airflow through these vents is required for system cooling Do not install the 1170 POS in a location not having sufficient ventilation Leave several inches of clearance on all sides where the air vents are located AC POWER LINE AND DATA LINE TRANSIENT PROTECTION The 1170 POS is a modern computer that can interface with a large variety of peripherals This POS system represents a significant financial investment for your site As such it must be protected against energy transients lightening strikes switching transients complete power loss or brownouts as you would protect any piece of computer equipment UTC RETAIL has a large variety of power and data line conditioner equipment and uninterruptible power supplies UPS th