Home
F007-EM User manual
Contents
1. 1 LI K input fingerprint twice 2 input another fingerprint twice i ID number 1 Manager add fingerprint ID number 2 Manager delete fingerprint The first Fingerprint Manager add Fingerprint it is to add the users The second Fingerprint Manager delete Fingerprint it is to delete users To add user Fingerprint Manager add Fingerprint Input User Fingerprint twice Repeat Manager add Fingerprint Card Manager add Fingerprint Cardi Repeat Manager add Fingerprint To add users continuously Fingerprint manager s add fingerprint 1 user fingerprint 2 user fingerprint Nth User Fingerprint Manager s add fingerprint Card Manager add Fingerprint Card 1 Card J Repeat Manager add Fingerprint To delete Fingerprint users Imanager s delete fingerprint 1 user fingerprint 2 user fingerprint Nth User Fingerprint Manager s delete fingerprint To delete Card users IManager s delete fingerprint Card 1 Card 2 Manager s delete fingerprint 4 Delete all the users b manager password i 20000 Note This will delete all fingerprints cards including Manager Fingerprint but except Manager Ca
2. Alarm Red shines fast Alarm 7 Technical sheet Supply Voltage 12VDC 10 Sleeping Current lt 20mA Stay Current lt 90mA Temperature 15 C 60 C Humidity 20 RH 95 RH Memory capacity 2160 Fingerprint capacity 160 Card capacity 2000 Card type 125KHZ ID card Card reading distance 50 30 mm Lock output load capacity 20A Alarm output load capacity 20A Resolution 450 DPI Fingerprint input time lt 1S Identification time lt 1S FAR lt 0 001 FRR lt 0 1 Dimensions 110L 70W 30H mm N W 500g G W 800g 8 Packing list Description Quantity Remark Door access machine F007 1 Infrared remote control 1 Master card 2 One for add the other for delete User Manual 1 Security Screws 3 7 Smm 1 To fix the front case to the back case Screw driver 1 Self tapping screws 4 25mm 4 Used for fixing Pastern stopper 6 25mm 4 Used for fixing 9 Two devices interconnected Function 1 F007 EM works as slave reader connecting to Controller F007 EM supports wiegand output it can be connected to the controller which support wiegand 26 input as its slave reader the connection diagram is as figure 1 J7 Green EB DO White EB D1 Grey ALARM Yellow ge OPEN Brown jg DIN Red EB 12V Black EB GND Blue EED VSS Purple L L Orange B a ei J Controller with
3. FOO7 EM Fingerprint amp RFID Access Controller User Manual Sebury Technology Co Ltd F007 EM Simplified Instruction Function description Choose from the relevant functions below and input Enter the programming mode 888888 then you can do the programming 888888 is the default factory master code change the master code 0 new code repeat the new code code 6 8 digit Add fingerprint user 1 Fingerprint repeat Fingerprint can add Fingerprints continuously Add card user 1 Card can add Cards continuously Delete user 2 Fingerprint 2 Card can delete Users continuously Exit from the programming mode How do release the door Fingerprint User Put the Finger on the fingerprint sensor for 1 second Card User Read card F007 EM Fingerprint amp RFID Access Controller 1 Introduction F007 EM is the new member of F Series Standalone Fingerprint access control as traditional it is in metal shell anti vandal supports fingerprint besides F007 EM support RFID card 125KHZ EM card and wiegand interface The high security and more powerful feature make it an ideal choice for door access User capacity 2160 including 160 fingerprint users and 2000 RFID card users With the flexible user capacity it is suitable to be installed from small house such as personal rooms shops office to public place
4. card To delete more than 1 card or fingerprint just input card or fingerprint continuously Note When delete fingerprint please input it once 2 By Remote Control Enter into programming mode Manager Password Default Manager Password 888888 Remarks All the steps below must be done after enter into programming mode 2 1 Change Manager Password 0 New Password Repeat New Password Remark The manager password must be 6 8 digit number 2 2 Add Users a ID number Auto generation To add fingerprint users L input one fingerprint twice f To add more than one fingerprints just input finger continuously To add card users Card Or L the Card Number 8 digit jf To add more than one card just input cards or Card number continuously Note when add card users it can just enroll the card number and don t have to enroll the card itself The card number is the 8 digit printing on the card In the same way when delete card users it can just enroll the card number to delete it and don t have to get the card if it is lost b ID number Appointment To add fingerprint users I ID number User Fingerprint jf Fingerprint User ID number can be any digit between 3 162 but one ID number to one user To add fingerprint users co
5. d card or wrong Password the device will lock on for 10 minutes 8 Remove Alarm When the device is in alarm from built in buzzer alarm equipment outside to remove it Password the device will alarm In 10 minutes if there s 10 times invalid card or wrong Read valid user s card or fingerprint or Manager Fingerprint or card or Manager Password H Any of the method above can remove the alarm 9 Two devices interlock setting manager password 8 8 1 H to enable this function 10 Setting Alarm signal output time manager password H OM UM E Alarm time is 0 3 minutes for option factory default setting 1 minute 5 User Operation User to release the door Card user Read card Fingerprint user Input Fingerprint 6 Sound and Light indication 0 A to disable this function factory default setting Operation Status LED Finger Sensor Buzzer Reset to factory default Orange Two short ring setting Sleeping mode Red shines slow Stand by Red shines slow Shine Enter into programming mode Red shines a Short Ring Exit from programming mode Red shines slow Short Ring Wrong operation Three short ring Open the door Green shines Short Ring
6. nput 7 GND Black Negative Regulated Power Input 8 VSS Blue the negative pole of the controller connect to the other part of Exit button and door contact 9 L Purple Connect to the negative pole of the Lock 10 L Alarm Orange Connect to the positive pole of the lock and alarm equipment Note Do not power on until all wiring has been completed 3 2 Intramural interface circuit Lock Interface Principle 12V Alarm Interface Principle By programme setting 1 0 j when alarm the I O outputs high level switch between low level oS L gt and high level 7 p7 r ALARM L 1 0 lt Q6 Q E rt 1 0 le Q5 nat DLI d i R10 eat R32 3 3 Method of Reset to Factory default setting and re register Manager cards Power off press the RESET key SW14 on the PCB hold it and power on release it until hear two short beeps the LED shines in orange then read any two EM cards after that the LED turns in red means reset to factory default setting successfully Of the two EM cards read the first one is Manager add card the second one is Manager delete card Remarks Reset to factory default setting the users information enrolled is still retained When reset to Factory setting the two Manager cards must be re enrolled 3 4 Connection diagram lock styles selections setit NO style unlock by power turned on by set the time 0 setit to NC style unlock by power off b
7. ntinuously UB I User Fingerprint 4 2 user fingerprint N W Nth user fingerprint To add card users IJ ID number Card jj Or I ID number the Card Number 8 digit fff Card User ID number can be any digit between 163 2162 but one ID to one Card To add card continuously I 163 i Card 164 KR Card N H Nth Card Or 1163 1 Card Number 164 K2 Card Number N Nth Card Number ff 2 3 Delete users Delete fingerprint users 2 fingerprint once H Delete card users 2 Card Or 2 Card Number To delete users continuously just input fingerprint or card continuously If delete users by ID 2 User ID Remarks When delete users the Master can just delete its ID number and don t have to input fingerprint or card It is the good option to delete if the users were left or cards lost 2 4 To save and exit from the programming mode 3 By Manager Fingerprint Enter into programming mode Manager Password Add Manager fingerprint
8. rd before this operation it is suggested to make sure the data is un useful 5 Lock style setting and door relay time setting Fail secure unlock when power on manager password jf 4 0 10 Fail safe unlock when power off E manager password H 5 1 10 Remarks In programming mode press 4 is to choose Fail secure lock 0 10 is to set door relay time 0 10 seconds press 5 is to choose Fail safe lock 1 10 is to set door relay time 1 10 seconds Factory default setting is Fail safe lock relay time 5 seconds 6 Setting Door open detection manager password 6 0 to disable this function factory default setting 6 1 to enable this function When enable this function a If open the door normally but not closed after 1 minute the inside Buzzer will alarm automatically the alarm will be off itself after 1 minute b 7 Setting Security Status If the door was opened force or the door was not opened in 20 seconds after lock was released the inside Buzzer and outside Siren will both alarm manager password Normal status 7 0 HK Lock on status 7 1 H Alarm status Factory default setting In 10 minutes if there s 10 times invali
9. such as large factories companies By Remote control or Master card for programming it is so user friendly that anyone can use it 2 Main Feature e Metal shell anti vandal User capacity 2160 160 Fingerprint users 2000 RFID card users Wiegand 26 output wiegand 26 input Besides standalone it can connect to other controller as the salve reader 2 pcs F007 EM can interconnect 2 pcs F007 EM can be interlocked Remote infrared programmer Manager card for programming Anti magnetic amp lock output current short protect So easy for connection of the lock only 2 wires output selecting lock type by programming menu Support connecting any card readers with wiegand interface such as HID Mifare EM Full of 2160 users searching speed lt 0 1 S 3 Install wiring and fixation 3 1 Install and wire Open the real plate from the front cover Drill 4 holes on the wall for screws and 1 hole for cable Fix the real plate on the wall firmly with 4 flat head screws Thread the cable through the cable hole wiring plug the cable harness Attach the front cover to the real plate Terminal Wire Connector Function 1 DO Green Wiegand output input signal wire DO 2 D1 White Wiegand output input signal wire D1 3 ALARM Grey connecting to the negative pole of the alarm equipment 4 OPEN Yellow To connect to one part of Exit Button 5 D_IN Brown Door Contact input 6 12V Red 12Vdc Positive Regulated Power I
10. the user capacity for one door can be up to 4320 Each user can use fingerprint or password for access 2 2 The setting of the two F007 EM must be the same If the master password was set different the user enrolled in the outdoor unit can t access from outside outdoor indoor DC12V 3A VO Green DO White D1 Green White Grey Grey ALARM Yellow Yellow OPEN Brown Red Black Blue Purple a on Dr sanas ALARM F007 EM controller 1 F007 EM controller 2 4 Two device interconnected amp interlocked two doors The connection is showed as Figure 4 for the two doors each door install one controller and one lock related The interlocked function will go when either door is opened the other door is locked forced only close this door the other door can be opened The interlocked function is mainly using in bank prison and other places where require higher security Two doors are installed for one access The user enters fingerprint or card on controller 1 the door 1 will open the user enters and close door 1 only after that the user can open the second door by entering fingerprint or card on second controller FOO7 EM controller F007 EM controller 2
11. wiegand 26 input j F007 EM If the controller is PC connection the users ID can be shown in the software a Card user its ID is the same as the card ID number b Fingerprint user its ID is the combination of device ID and fingerprint ID The device ID is set as below manager password B device ID Note Device ID can be any digit of 0 255 For example device ID was set 255 fingerprint ID is 3 then its ID to the controller is 255 00003 2 F007 EM works as Controller connecting slave reader F007 EM supports wiegand input any card reader which support wiegand 26 interface can connect to it as its slave reader no matter it is ID card or IC card The connection is showed as Finger 2 when add cards it is required to do it at the slave reader but not controller except EM card reader which can be added on either reader or controller FOO7 EM controller Wiegand raager ma HA DO Green W D1 White ALARM Grey OPEN Yellow Brown Red Black Blue Purple 3 Two F007 EM interconnected single door Wiegand output Wiegand input The connection is showed as Figure 3 One F007 EM installed inside the door the other outside the door two devices interconnect Either device acts as the controller and reader at the same time It has below feature 2 1 Users can be enrolled on either of the device The information of the two devices can be communicated In this situation
12. ysettime 1 10s FOO7 EM controller Power 1 Green White Grey Yellow Brown Red Black Blue Purple Orange diagram for using one power supply for lock and controller Remark F007 EM can connect both types of the locks directly no matter it s Fail secure unlock when power on or Fail safe unlock when power off Please check Manager Operation Item 5 for the lock setting 4 Manager Operation There are 3 ways to add and delete users 1 by Manager card 2 by remote control B by Manager fingerprint 1 By Manager Card the most convenient way 1 1 Add Fingerprint user Manager add card Enter 1 User Fingerprint Twice 2 User Fingerprint Twice Manager add card Note When add fingerprint please input each fingerprint twice during which the LED shines red then turn green means the Fingerprint is enrolled successfully When delete fingerprint just input it once 1 2 Add Card user Manager add card 1 User card 2 User card Manager add card Remark Fingerprint user ID is 3 162 Card user ID is 163 2162 when add fingerprint or Card by Manager card it is produced automatically from 3 160 or 163 to 2162 ID 1 2 are belong to Manager fingerprint 1 3 Delete users Manager delete card card OR Fingerprint once Manager delete
Download Pdf Manuals
Related Search
Related Contents
Manual - Xcelris Genomics Philips 40PFL7664 LCD TV User Manual Copyright © All rights reserved.