1. in Body mode Reasons for LO message display Temperature reading hampered by hair Make sure there is no obstruction or or perspiration dampness prior to taking temperature Temperature hampered by an air draft or Make sure there is no air blowing in the dramatic change in ambient area of use this could affect the low temperature temperature infrared reading measurement can Temperature readings are too close together Pause for 15 seconds minimum between occur for various and the thermometer did not have time to readings a one minute pause is reasons reboot recommended 15 Accessories Supplied e User manual in English e Protective storage bag e Two AAA batteries
2. 0 6 F 36 0 C 39 0 C 0 2 C 96 8 F 102 2 0 4 F 39 1 C 42 9 C 0 3 C 102 4 F 109 2F 0 6 F Note IR thermometer Smart ThermoGraph precision according to ASTM Standard E1965 1998 2009 e 34T 35 99 0 3 C 93 2 F 96 6 F 0 6 F e 36 C 39 C 0 2 C 96 8 F 102 2 F 0 4F e 39 C 42 5 C 0 3 C 102 2 F 108 5 F 0 6 F IEC 60417 5333 Type BF applied part EC 60417 5031 Direct current IP22 IEC 60529 Ingress protection WEEE Directive 2002 96 EC CR Consult operating instructions Body Temperature Measurements The IR thermometer Smart ThermoGraph has been developed using the latest infrared technology This technology allows you to take the temporal artery TA temperature from the forehead It has been demonstrated that this method of TA temperature measurement is more precise than tympanic thermometry and better tolerated than rectal thermometry Precise instantaneous IR thermometer Smart ThermoGraph is currently the most suitable device for safe body temperature measurement As with other types of thermometer you must use the IR thermometer Smart ThermoGraph properly to obtain reliable and stable results Please read this instruction manual and the safety precautions carefully before using the device Greenes D Fleisher G Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants Arch Pediatr Adolesc Med 2001 155 376
3. been demonstrated that this relatively new method of measuring body temperature is more precise than tympanic thermometry and better tolerated than rectal thermometry The IR thermometer Smart ThermoGraph has been designed to produce an instant forehead temperature reading without any contact with the temporal artery This artery is quite close to the skin surface so it is accessible and its blood flow is permanent and regular allowing precise measurement of body temperature It is linked to the heart by the carotid artery which is directly linked to the aorta It forms part of the main trunk of the arterial system The efficiency speed and comfort of taking body temperature from this area make it ideal compared to other body temperature measurements methods Preparation We recommend practicing the temperature measurement technique before you use this device to ensure precise and accurate temperature measurements and to receive correct information Although taking a temperature is a simple procedure it must not be trivialized You must take a person s temperature when their body is in a neutral ambient state They must not have undertaken strenuous physical activity before the measurement and the room temperature must be moderate You must take into account physiological variations in body temperature when evaluating measurement results e Body temperature increases by 0 5C between 6am and 3pm 8 e On average women have a high
4. IR Thermometer Smart ThermoGraph User Manual Thank you for purchasing the IR thermometer Smart ThermoGraph with advanced thermo monitoring features Introduction The IR thermometer Smart ThermoGraph is an infrared thermometer and thermograph in one device designed for thermo monitoring of inflammatory sicknesses of organs close to the skin surface It measures body temperature in a way similar to common IR thermometers in Body mode and measures the skin surface temperature in Surface mode Smart Thermograph is a portable battery powered device that uses advanced infrared technology for temperature measurement Smart Thermograph has two supported modes that allow you to measure body temperature or surface temperature You can measure surface temperature using just the IR thermometer Smart ThermoGraph or you can connect it to any mobile device such as smartphone or tablet computer that supports Bluetooth 4 0 LE Using Smart ThermoGraph mobile applications allows you to see the surface temperature distribution of any area of your skin surface on the screen of your smartphone or tablet computer To achieve consistent results during your temperature monitoring session you must follow the procedures described in this manual The IR thermometer Smart ThermoGraph e Measures the surface temperature of any part of the skin e Uses a measurement unification feature to provide reproducible temperature measurements e Measures body temperatu
5. Radiant Energy All objects solid liquid or gas emit energy by radiation The intensity of this energy depends on the temperature of the object The IR thermometer Smart ThermoGraph measures human body temperature by the energy the person emits When you hold the device near the body the radiation sensor is activated and a measurement is taken instantly by detecting the infrared heat generated by the arterial blood flow As a result you can measure body heat without any interference from the heat of the surrounding environment Body Temperature Measurement Methods Core temperature Core temperature is the temperature of brain and internal organs This method is the most precise measurement because it measures the temperature in the pulmonary artery by using a catheter with a thermal probe The same method is used for probes measuring the esophageal temperature However such invasive temperature measurement methods require specific equipment and expertise Rectal temperature Rectal temperature adjusts slowly in comparison to the changes of the body s internal temperature It has been demonstrated that rectal temperature remains raised long after the internal temperature of the patient has started to drop and vice versa Oral temperature Oral temperature is easily influenced by recent ingestion of food or drinks and by breathing through the mouth To measure oral temperature the mouth must remain closed and the tongue lowered for thre
6. aaeeeseeaeeeeneaaes 9 Surface Temperature Measurements ENNEN 10 Measurement Conditions s irati asa aaea inh ated Ae ine ita ae ae tanita 10 Measuring Surface Temperature ccccccceececeeeceeeeeeeeneeceeeeeceaeeeeaaesseneecaaeeesaaeseeaaessaneeseaeeeeaaesseaeeseaeeesaesseaeesenees 12 eer ER te E 13 le elen e ln Le EE 15 Accessories ele DEE 16 General Information Safety Instructions You can use IR thermometer Smart ThermoGraph for personal home use or for professional purposes To ensure that you use it correctly please follow these safety instructions Note Follow the usage guidelines requirements stipulated in this instruction manual Use this device only for the purposes described in this instruction manual Use this device only when the surrounding ambient temperature is between 10 C and 40 C Always store this device in a clean dry area Do not expose this device to electric shocks Do not expose this device to extreme temperatures over 50 C or under 20 C Do not use this device in relative humidity higher than 85 Do not expose the device to sunlight or water Do not drop or hit the device The protective glass over the lens is the most fragile part of the device Should a problem occur with your device please contact your distributor Do not attempt to repair this device yourself The manufacturer reserves the right to alter product specifications without prior notification The Smart ThermoGraph d
7. e to four minutes during the measurement which is a difficult task for young children to accomplish Axillary armpit temperature Although it may be easy to measure axillary temperature it has been proven that it does not provide an accurate measurement of the child s internal temperature To take this type of temperature the thermometer must be wedged tightly over the axillary artery Despite the low sensitivity and relative inaccuracy of axillary temperature in detecting fever this method is recommended by The American Academy of Pediatrics as a screening test for fever in newborns Tympanic temperature Obtaining a precise temperature reading requires a good command of the measurement technique The thermometer probe must be placed as close as possible to the warmest part of the external ear canal An incorrectly placed probe could lead to a false temperature reading Normal Body Temperatures by Measurement Method Measurement Method Normal Temperature Rectal 36 6 38 C Oral 35 5 37 5 C Axillary 34 7 37 3 C Auricular 35 8 38 C Temporal 35 8 37 8 C IR Thermometer Smart ThermoGraph Body temperature varies throughout the day It can also be influenced by external factors such as age sex skin type and skin thickness Advantages of Temporal Artery TA Temperature Measurement Infrared arterial temperature can be measured by placing the device on the forehead in the temporal artery region It has
8. emperature values with the results from the previous session of thermo monitoring e H the maximum temperature and the average temperature have both decreased the values are shown in green e H the maximum temperature and the average temperature have both increased the values are shown in red e lf the maximum temperature or the average temperature have not changed or one has increased and the other has decreased the values are shown in yellow For more information please download the free Smart ThermoGraph app and read the Help 14 Troubleshooting If you experience a problem using your device please refer to this guide to help resolve your problem If the problem persists please contact our customer service A temperature higher than 42 9 C 109 2 F is displayed The temperature is in Fahrenheit Change the measurement to Celsius by pressing the C F button A temperature lower than 32 C 89 6 F is displayed To take the surface temperature press the Mode button and set it to the Body mode If the device is in Surface temp mode and the temperature value is 32 C 89 6 F the thermograph shows the external temperature of the body not the internal temperature A HI message is displayed The measured temperature is above the device s measurement range or above 42 9 C 109 2 F in Body mode A Lo message is displayed The measured temperature is below the device s measurement range or below 32 C 89 6 F
9. er Smart ThermoGraph consistently and correctly Select a surface point in the area of interest and measure its temperature at least three times You know that you are measuring the temperature correctly if these measurements do not vary by more than 0 2 C When you can achieve consistent results you have sufficient skills for correct temperature measurement Special Applications Taking regular measurements of the skin surface temperature at one point in an inflamed area is the simplest type of thermo monitoring and it provides useful information However take regular measurements of several adjacent points provides you with much more valuable information For fast and simple processing of such measurements you could download free Smart ThermoGraph software This software allows more advanced thermo monitoring by providing a visual representation of the temperature distribution thermogram on any part of the skin surface Measuring skin surface temperatures in several adjacent points including points in the inflamed area allows you to obtain dynamic temperature distribution details You can carry out thermo monitoring using larger amounts of valuable information than thermo monitoring of only one point 13 By using Smart ThermoGraph software you can conduct correct thermo monitoring of any skin surface zone Thermo monitoring of areas of interest by Smart ThermoGraph software allows you to estimate the dynamics of thermal signs o
10. er body temperature around 0 2C than men e Women s body temperatures also vary with their ovarian cycle rising by 0 5C in the second half of the cycle and in the early stages of pregnancy Measuring Body Temperature 1 Observe the following guidelines when you take body temperature measurements to ensure stable and reliable results e Push hair back from the forehead e Wipe away any perspiration from the forehead e Allow a 1 minute interval between measurements 2 Place the sensor of the IR thermometer Smart ThermoGraph on the temporal region of the forehead 3 Press the Scan button The body temperature is displayed instantly Normal Body Temperatures by Age Age Normal Temperature 0 2 years 36 4 38 0 C 97 5 100 4 F 3 10 years 36 1 37 8 C 97 0 100 0 F 11 65 years 35 9 37 6 C 96 6 99 7 F gt 65 years 35 8 37 5 C 96 4 99 5 F Surface Temperature Measurements In surface temperature Surface temp mode the IR thermometer Smart ThermoGraph measures infrared thermal radiation from any surface including skin The skin surface temperature is more variable than the body temperature and generally lower than the body temperature The skin temperature of the nose ears hands and feet is the most variable because it depends on the ambient temperature Skin surface temperature has no precisely defined normal values so the IR thermometer Smart ThermoGraph is not in
11. erature changes significantly data about the area s temperature dynamics will not be reliable e Air conditioners or heaters are turned off or situated so they do not affect the measurement point e The person under examination is in a comfortable and relaxed position e The skin area has been freed from clothes or bandages for at least 10 minutes before temperature measurement e The skin area has not been handled for at least 10 minutes before temperature measurement e Hair on the skin area is pushed away so it does not interfere with the measurement process e The skin area is free of perspiration We recommend that you take temperature measurements at the same time of the day preferably in the morning before breakfast 10 Before the examination avoid any procedures manipulations or influences that might affect the temperature distribution in the area of interest based on the following guidelines e Wait at least one hour after hygiene procedures application of creams shaving the area of interest prolonged pressure or other mechanical influences For example do not measure back temperature if the person was lying on their back for a prolonged period before measurement e Wait at least 24 hours after massage physiotherapy depilation or peeling of the area of interest e Wait at least two weeks after skin traumatizing influences such as tattooing or piercing procedures in the area of interest However if you
12. evice is pre set at the factory You do not need to calibrate the device when you first use it If you move the device between areas that have significantly different environmental temperatures you should allow an acclimatization period of 15 to 20 minutes before use to obtain reliable and stable results Product Description Battery Measuring Display Measuring compartment button screen part Mode button Memory button CIE button Display screen Surface temp Celsius Temperature Memory Low Battery Buzzer Mode button To set the mode e Press the Mode button The screen displays Surface temp C Use this mode to measure skin surface temperature e Press the Mode button again The screen displays Body C Use this mode to measure body temperature By default the device is set to Surface temp mode and Bluetooth switches on automatically Important The surface temperature differs from the internal body temperature e Always use Body mode to measure the internal temperature e Always use Surface temp mode to measure surface temperature C F button Press the C F button to switch between Celsius and Fahrenheit Sensor Place the sensor on the temperature measurement point Scan button Press the Scan button to take a temperature measurement Mem button Press the Mem Memory button to display the last temperature measured You can view the last 32 measurements taken Batteries This device uses
13. f inflammation You can also correctly estimate the effect of various influences on the surface temperature With Smart ThermoGraph software you can obtain visual and digital information about responses to different influences on the skin surface temperature The IR thermometer Smart ThermoGraph with the Smart ThermoGraph software are not intended for diagnosis they are intended for thermo monitoring of the skin surface area Based on the results of your surface temperature measurements in several adjacent points Smart ThermoGraph software plots a thermogram temperature distribution on the area of interest overlaid on a photo of that area on the screen of your smart phone or tablet The first thermogram and temperature values are a prerequisite for further thermo monitoring In the thermogram e Zones with a relatively high temperature in the area of interest are shown in red and orange e Zones with relatively low temperature in the area of interest are shown in blue and purple e Zones with relatively intermediate temperature values in the area of interest are shown in green and yellow Based on the measurement results the Smart ThermoGraph software automatically generates a digital result that includes the maximum temperature and the average temperature for the area of interest Starting from the second examination session of the same area the Smart ThermoGraph software automatically shows the comparison of the results of these t
14. re by taking the forehead temperature e Connects to your Smartphone with the Smart ThermoGraph application e Gives quick reliable results due to the advantageous infrared detection system e Has an audible alarm if measured temperature is exceeded e Memorizes 32 measures e Has an easy to read backlit lit LCD digital screen e Can display temperatures in Celsius or Fahrenheit e Automatically powers off 30 seconds after the last measurement to save power e Is practical and easy to use Please read this manual carefully before using the device and keep this manual for future reference Consult a doctor if you have concerns about specific body temperature values Your doctor can also provide more detailed information about your temperature readings and help you to use the device Contents fend 10 BT LOU SRS TAE 1 eu 2 General e ee EE 3 Safety Ee e EE 3 Description of the IR Thermometer Smart Thermographie 4 Technical Specitications lt engen aa A BR a il pera heat ences ae dh aie vd ee eee eee 5 Body Temperature Measurements ANEN 7 Radiant Ener EE 7 Body Temperature Measurement Meibode AAA 7 Normal Body Temperatures by Measurement Method 8 Advantages of Temporal Artery TA Temperature Measurement ene 8 Preparation s a E E EE EE 8 Measuring Body Temperature ereenn iaoa aa ari a ia i i a i i 9 Normal Body Temperatures by Age eeecccceeceeeeeeeeeeeeeeeeeeeaeeeeeeaaeeeseeaaeeesenaaeeeeeeaaeeeeeeaaeeeeeeaaeeeseeaaeeeese
15. tended for diagnosing inflammatory diseases it is intended only for thermo monitoring The surface temperature distribution of a healthy person is approximately symmetrical It decreases from the head to the fingers and toes However it varies between individuals depending on their age gender dietary habits physical activity and the ambient temperature You can use the IR thermometer Smart ThermoGraph to measure the skin surface temperature of any area of the body including inflamed areas Inflammatory diseases of the skin and organs near skin are accompanied by an increase in the temperature of the corresponding skin surface If you regularly measure the surface temperature of the same point in an inflamed area you can monitor temperature changes By repeatedly measuring skin temperature at the same point and then comparing the current value with the previous value you can accurately assess the dynamics of temperature change at this point These repeat measurements of skin temperature for a specific point of inflammation provide you with more useful information than body temperature alone Measurement Conditions Before you measure the skin surface temperature make sure that the following conditions are met e Ambient temperature is between 20 C and 26 C e The ambient temperature must remain constant during the temperature measurement session and change no more than 3 4 C between measurement sessions If the ambient temp
16. two 1 5V AAA size batteries Replace the batteries when the battery replacement indicator appears on the screen 1 Open the lid and insert the new batteries Ensure that the battery polarity and positioning are correct Incorrect battery replacement could cause damage to the device and compromise your device s warranty 2 Close the lid after replacing the batteries Important Never use rechargeable batteries Use only single use batteries Do not recharge non rechargeable batteries Do not throw batteries in the fire Remove the batteries if you are not using the device for an extended period of time Technical Specifications Operating temperature range 10 C 40 C 50 F 104 F Not greater than 85 relative humidity Note The IR thermometer Smart ThermoGraph can take temperature readings below 32 C 89 6 F and above 42 9 C 109 2 F but precision is not guaranteed outside this range Temperature measurement ranges Body mode 32 C 42 9 C 89 6 F 109 F Surface mode 0 C 60 C 32 F 140 F Power DC 3 volt two AAA batteries Size 145mm x 45mm x 55mm Weight 74g without batteries Display resolution 0 1 C 0 1 F Consumption 300mW or less Note IR thermometer Smart ThermoGraph was created for home and professional use it is guaranteed for 40 000 temperature measurements Automatic power off 30 seconds after reading Accuracy 32 0 C 35 9 C 0 3 C 89 6 F 96 6 F
17. wanted to monitor the effect of a specific procedure you could measure the surface temperature before and after the procedure 11 Measuring Surface Temperature 1 Choose the surface temperature mode on your IR thermometer Smart ThermoGraph The screen displays Surface temp 2 Place the sensor at a 90 degree angle perpendicular to the skin surface that you want to measure Use the same amount of pressure that you use when working with a touchscreen If you want to measure the temperature of an injured area hold the measuring sensor 3 5cm away from the skin surface Important Do not allow the measuring sensor to contact open wounds Measurement accuracy is assured if you use the correct method to measure the temperature You must place the IR thermometer Smart ThermoGraph perpendicular to the skin surface to obtain the correct temperature value 12 It is important to hold the device comfortably in your hand during measurement For self examination of areas such as your knee we recommend that you rotate IR thermometer Smart ThermoGraph by 180 degrees so the measuring sensor is toward you If it is difficult for you to measure skin surface temperature on some part of your body you should ask for assistance 3 Press the Scan button The IR thermometer Smart ThermoGraph displays the surface temperature of the measured area for one second To obtain accurate temperature values you must learn how to use the IR thermomet