WAITIN ON NEW DRAWINGS FOR BACKGROUND

image

Contents

1.
2. TIONAL OPTIONS MD3 A pair of LightViper MD3 units may be used to transport RS 422 MIDI or RS 232 from FOH to stage via the RJ45 connector on the VIM MY32S card MD3 FRONT amp BACK DMXA A pair of DMX4 enables the user to send 4 universes of DMX lighting control data or 3 universes and Yamaha control The Yamaha control is connected via the DB9 connector on the DMXA DMX4i amp 4 DGL 422 This interconnect cable contains active electronics and allows the user to transport Yamaha control from the Yamaha console to the stage unit via the RJ45 connector on the VIM MY32S card LightViper VIM MY32 Card Specifications 6 Buddy to insert spec s here ee Aiquessy ZEAW WIA uooxejdeq A H LV A O 00L0 v09 LO EE SZE AIA INIA Bs uD L0Z0Z GW uonounr s jodeuuy PY PIONO 217 0801 BARIS PALA SCEAW WIA DL WCEAW WIA SSRN pue soe potu 2294 V 1 WZEAIW WIA 29O INC AIN IWIA PED 24 3 20 WZEAW WIA 1S IWZ AW WIA 0vL v ZHM9Y ZHM8Y uonisog uonisog 9AE S 1500 J9 SE N YOO D n ec n 1e o dE j vVIS X JAVYS Laca HOLIMS NOILO4 13S 420 19 SL dA L LS INC AIN INIA vic i c6E 9 sound the speed of light LightViper fiberplex inc wwwlightvipercom 301 604 0100 sales lightviper com FIBEROPTIC AUDIO SNAKE LVUM10 2004 10
3. a Yamaha LS9 the VIM MYS32M Master card must be used in slot 71 only The control must also be assigned to slot 71 only VIM MY32M T4 xxu 9 x HA REMOTE N C J WI A LY ae eae e Sy ok wh YY O9 S SE CH 17 32 OUT VIM MY32MT4 Master VIM MY32S Slave The VIM MY32MT4 VIM MY32MOC and VIM MYS2MST are identical with one exception The T4 versions contains a single TAC 4 fiber connector The OC version contains a single Neutrik OpticalCon fiber connector and the ST version contains a pair of ST fiber connectors The VIM MY32T4 Master and VIM 25 Slave card are shown here Drawings of all versions can be found on page 14 VIM MY32M Master Card Neutrik MiniCon Connector This 12 pin connector is used to connect the VIM MY32M master card to the VIM MY32S slave card 2 Slave LED This LED shows the status of your connection between your master and slave cards If the LED is not lit there is no connection If the LED is solid green the connection between master and slave cards is active Sync LED This LED indicates the clock sync status of the system lf the LED is not lit the card is not receiving power If the LED is flashing green this means the system is searching for sync If the LED is solid green the system is in sync ST Fiber Pass Through Connectors These fiber pass throughs appear only on the VIM MY32MT4 vers
4. ion of master card These pass troughs allow you to access the additional 2 fibers in a TAC 4 connectos and connect them with the additional VIM MY32MST master card in systems with 48 or 64 channels On a 32channel system these ST pass throughs would not be used as there is only 1 master required for a 32x8 system The main fiber connection illustrated above contains a 4 connector Other versions contain either a single Neutrik OpticalCon fiber optic Connector or 2 ST Liber optic connectors VIM MY32S Slave Card Neutrik MiniCon Connector This 12 pin connector is used to connect the VIM MY32M master card to the VIM MY32S slave card 9 TTL CTL Connector This connector is for use with the LightViper DGL 422 control cable as well as LightViper or DMXA units CTL SEL Switch This switch determines which connector on the VIM MY32S Slave card is active owtich to the left for RJ45 TTL CTL center for LS9 back plane control and right for DB9 control 9 HA Remote Connector This connector is for connecting a stright DB9 to DB9 cable from the DB9 control output connector on the Yamaha console to the DB9 on the VIM MY32S card CLOCK SELECTION SWITCH CLE ni B ax is ax um LY Clock Master Clock Slave Position Position 46K Hz 48KHz Clock Master Slave Switch This switch is found on the VIM MY32M master circuit board If the VIM MY32 c
5. lock on the VIM MY 32M is being used as the main system clock switch this to Master If the Yamaha console internal clock is being used as the master clock set this switch to Slave When using VIM MY cards on a split the clock selection switch on the VIM MY32 master card s must be set to Master as these cards will be feeding the master clock to the split console Fiber Options Tactical grade military fiber TAC 4 is used for live production applications P N TFC 0000 04 Weighing 8 4 Ibs 12 6kg for 300 feet this cable contains 4 fibers and therefore it is capable of carrying the signals of 2 VIM 1808 0808 systems on a single cable The TAC 4 connectors are hermaphroditic and can be connected to one another Multimode fiber can transport signals up to 2km 1 25 miles Neutrik OpticalCon Fiber this fiber cable contains 2 fibers and is also a tactical grade fiber P N TFC 0000 020C This fiber cable is transporting 1 VIM 1808 0808 3 system 5 amp Neutrik OpticalCon Fiber Cable amp Panel Mount Connector PVC fiber PVC duplex fiber contains 2 fibers Plenum rated fiber is also available The installer can terminate the fiber themselves or Fiberplex can supply it pre terminated This fiber is also available with a strain relief and pulling eye which iml reduces site labor A single length of PVC duplex fiber can transport 1 VIM 1808 0808 system Plenum Install Fiber ADDI
6. ontrol from your Yamaha into the LightViper system to remotely control digital microphone preamplifiers i e Yamaha AD8HR Aphex 1788A etc The RJ45 connector is for use with the LightViper DGL 422 cable only This cable contains active electronics that translate the Yamaha control protocol for the LightViper system The DB9 connector may be used with a straight DB9 to DBO9 cable utilizing the translation electronics on the VIM MY32 card itself The switch in between these connectors should be set to correspond with the connector being used left or TTL for the RJ45 right or HA for the DB9 connector In the case of the Yamaha LSS9 this console has no external control connector Control is fed internally to the back plane of the VIM MY392 card itself If you are using VIM MY32 cards with a Yamaha LS9 the switch should be set to the middle internal position Accessory LightViper products such as DGL 422 Yamaha control protocol MD3 RS 422 MIDI RS232 control and DMX4 DMX lighting control plus Yamaha control The Yamaha console will not display VIM MY32 on the console screen The Yamaha console will recognize the VIM MY32 card as a generic 16 channel expansion card The name shown in the text field will be displayed as a generic name i e ADAT 16 What is displayed may vary with the model and or software version being run on the Yamaha console Some Yamaha mixers may not be compatible with the LightViper VIM MY32 cards Soft
7. quired This jumper connects one master card to the other Getting Started To install your VIM MY32 cards please follow these steps 1 Power down your Yamaha console 2 Setclock master slave switch on master card s This switch is found on the VIM MY32M master circuit board If the VIM MY32 clock on the VIM MY32M is being used as the main system clock switch this to Master If the Yamaha console internal clock is being used as the master clock set this switch to Slave 3 Insert cards into appropriate YGDAI card slots aligning the sides of the card with the with the support guides in the YGDAI slot 4 Connect master slave cards with supplied Neutrik MiniCon cable 5 Connect if applicable supplied fiber pass through cable VFC 0001 DST between VIM MY32MT4 and VIM MY32MST cards 6 Press the VIM MY82 card firmly in place ensuring a complete connection between the multipin back plane of the VIM MY32 card and the console Secure the VIM MY32 card with supplied thumb screws Power up your Yamaha console Check to see that slave LED is solid green 0 Ensure that the sync LED is solid green 1 Input audio signals and check for audio in both directions zi ce Advanced functions of the Light Viper VIM MY32 cards control clocks etc 1 Using Yamaha control protocol with the LightViper VIM MY32 cards On the VIM MY32S slave card there are DB9 and RJ45 connectors These connectors are used to input c
8. soundathe speed oflight VIM MY32 Functional Considerations e The LightViper VIM MY32 cards contain no user serviceable parts Please contact Fiberplex directly with any service issues e The LightViper VIM MY32 cards are for use with Yamaha digital consoles containing YDGAI card slots ONLY e he VIM MY32 cards are powered from the Yamaha console ALWAYS POWER DOWN YOUR CONSOLE BEFORE INSERTING OR REMOVING VIM MY32 CARDS FROM YOUR CONSOLE Standard Components In its standard configuration the Light Viper VIM MY32 cards are made up of the following primary components The VIM MY32 Cards The VIM MY32 cards are available in 4 versions 3 masters 1 slave The VIM MY32MST is a master card containing 2 ST fiber connectors The VIM MY32MOC is a master card containing a single Neutrik OpticalCon connector The VIM MY32MT4 is master card containing a single TAC 4 four fibers connector The VIM MY32S is a slave card and contains no fiber connectors The Master Slave Interconnect cable each master slave pair purchased comes with a high speed Neutrik 12 pin MiniCon M connector This cable connects the master card to the slave card The Fiber Jumper Cable For those purchasing VIM MY32MT4 cards with a system of 48 or 64 channels a duplex PVC fiber cable is supplied to connect the fiber pass throughs on the VIM MY32MT4 to the VIM MYS2MST card In 48 or 64 channel configurations 2 master modules are re
9. ware and firmware updates to the console may be required Consult with Yamaha customer service or your console manual for additional information Setting up your Yamaha Console for operation with LightViper MY32 cards 1 Go to the input patch screen and assign inputs to the appropriate slots 2 Goto the output patch section and patch your outputs to the appropriate slots Important Note While the Yamaha console shows 16 patchable outputs on the display screen only 8 on each master card are actually assignable You must assign outputs to the slot which contains the VIM MY32 master card There are 8 returns on a 32x8 system utilizing 1 VIM MY32 master and 1 VIM MY32 slave 16 returns on a 48x16 system utilizing 2 VIM MY32 masters and 1 VIM MY32 slave and 16 returns on a 64x16 system with 2 VIM MY32 masters and 2 VIM MY32 slaves When using VIM MY32S slave cards on a split none of the control functions are operational from these split positions only the primary VIM MY32S cards located at FOH have the capability of utilizing these control functions When using VIM MY cards on a split the clock selection switch on the VIM MY32 master card s must be set to Master as these cards will be feeding the master clock to the split console If using a system that contains both a LightViper VIM 1832 mixer box and VIM MY32 cards the VIM 1832 must operate at 24bit 48k using the external clock input Note When using the cards with