1. B1 B2 max 2m Set up the laser on its tripod or wall mount bracket near point A1 at a minimum distance of 1 5 m from point B1 The horizontal laser is aligned in direction 1 Mark the laser dots A1 and B1 with a pin Rotate the instrument by 180 so that it points in the opposite direction 2 to direction 1 Adjust the instrument 8 Operation so that the laser beam hits point A1 exactly If point B2 is no further than 2 mm away from point B1 then the PLL 11 is within tolerance CE Should your CLL 11 PLL 11 be outside of the specified tolerance please contact an authorised dealership of W rth Electronics Display notices Falling below or exceeding the permissible temperature range The laser switches off and all symbols flash Outside of the self levelling range The laser switches off and the symbol of the function used starts to flash Pendulum locked The laser beam is not levelled and the Lock symbol lights up Operation LLE 11 Display status symbols W rth LLE 11 The W rth LEE 11 is a robust and easy to use laser receiver and can be used with all W rth line lasers Keypad Sensivity fine 1 mm default Sensivity coarse 3 mm Battery status full Battery status low Beep medium Beep high Beep off Move receiver down Move receiver up ON OFF key switch the receiver on off Beeper key change the sound
2. mount bracket Operation Checking the accuracy GE Check the accuracy of your CLL 11 PLL 11 regularly and particularly before important measuring tasks Checking the accuracy of the levelling gt 2 5m 2 5m Set the instrument on a tripod half way between two walls A B that are approx 5 m apart Place the Lock switch in the Unlocked mf position Direct the instrument at wall A and switch on the inst rument Activate the horizontal laser line or laser dot and mark the position of the line or the dot on wall A gt A1 Rotate the instrument by 180 and mark the horizontal laser line or the laser dot in exactly the same way on wall B gt B1 Then place the instrument at the same elevation as close as possible to wall A and again mark the horizontal laser line or the laser dot on wall A gt A2 Rotate the instrument by 180 again and mark the laser on wall B gt B2 Measure the distances of the marked points A1 A2 and B1 B2 Calculate the difference of the two measurements If the difference does not exceed 2 mm then the CLL 11 PLL 11 is within tolerance A1 A2 B1 B2 lt 2 mm E R Operation Checking the accuracy of the horizonial line Checking the accuracy of the vertical line max 2mm i 1 5m Place th
3. not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV tech nician for help A WARNING Changes or modifications not expressly approved by W rth for compliance could void the user s authority to operate the equipment Laser classification The CLL 11 PLL 11 produces visible laser beams which are emitted from the instrument It is a Class 2 laser product in accordance with 1EC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex A WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Safety instructions 8 Labelling Laser Radiation Do not stare into the beam Laser class 2 in acc with IEC 6
4. point O O OQOOO Operation Switching on off ON Briefly press the On Set key OFF Press and hold down the Pulse key Q Laser functions Pressing the On Set key Q activates the following laser functions PLL 11 CLL 11 Acti P en not in Lock in Lock mode not in Lock in Lock mode mode mode only only 1x all points horizontal all lines horizontal line line 2 all lines and only vertical horizontal only vertical points line line line only 3x plumbing again as 1x vertical line again as 1x point 4x again as 1x again as 1x 8 Operation Self levelling and Lock functions The instrument automatically levels itself within the specified grade range Refer to Technical data Press the Lock switch in order to transport or tilt the instrument beyond the self levelling range When locked the pendulum is fixed and the self levelling func tion is deactivated Pulse To be able to detect the laser lines over long distances gt 15 m or in unfavourable lighting conditions a laser detector can be used The detector is able to locate the laser beam in Pulse mode even over long distances Laser detector refer to accessories Applications CLL 11 Bn ao Gere N R gt l IX bX A How to use the wall
5. 0825 1 2007 Maximum radiation power lt 1 0mW c w Emitted wavelength 620 690nm Beam divergence lt 180 Laser Radiation Do not stare into the beam Laser class 2 in acc with IEC 60825 1 2007 Maximum radiation power lt 1 0mW c w Emitted wavelength 620 690nm Beam divergence lt 1 5 mrad Laser Radiation Do not stare into the beam Laser class 2 in acc with IEC 60825 1 2007 Maximum radiation power lt 1 0mW c w Emitted wavelength 620 690nm Beam divergence lt 180 a ae Safety instructions
6. User Manual English Before using the product for the first time please read carefully through the Safety Instructions and the User Manual The person responsible for the instrument must ensure that all users understand these directions and adhere to them Contents StartUp sai eniGangiee dunia beasts Operation Pe Operation LLE 11 Care and advice on operation 04 11 Transport Warranty ansia araara Technical data PLL 11 CLL 11 0 0 12 Technical data LLE 11 Safety instructions 0 0 cee Start up Inserting replacing batteries Slide the locking button forwards to unlock the battery compartment Open the battery compartment cover and insert the batteries observing the correct polarity Then press the battery compartment cover back down until it engages The battery symbol lights up when the battery voltage is too low Replace the batteries as soon as possible Insert the batteries observing the correct polarity Use alkaline batteries or rechargeable batteries only Remove the batteries if the instrument is not to be used for a long period of time to prevent corrosion Start up Operation Keypad and control elements On Set key Pulse key Lock switch Battery voltage too low Pulse Power save mode ON Horizontal laser line Vertical laser line Plumbing point Plumbing and crossline intersection
7. atteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations Safety instructions pa The product must not be disposed of with the household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unau thorised personnel WARNING Using a battery charger not recommended by Wirth can destroy the batteries This can cause fire or explosions Precautions Only use chargers recommended by Wirth to charge the batteries Electromagnetic Compatibility EMC A WARNING The CLL 11 PLL 11 conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of it causing interference in other devices cannot be totally excluded 15 Safety instructions FCC statement applic in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will
8. e Lock switch in the Unlocked a position Position the instrument approx 5 m away from the wall Direct the instrument at the wall and switch on with the On Set key Q Activate the laser line with the On Set key and mark the intersection point of laser crosshairs on the wall Swivel the instrument to the right and then to the left Observe the vertical deviation of the horizontal line from the marking If the difference does not exceed 3 mm then the CLL 11 PLL 11 is within tolerance Operation Place the Lock switch in the Unlocked wa position As reference use a plumb bob and attach it as close as possible to an approx 3 m high wall Position the instrument at a distance of approx 1 5 m from the wall at an elevation of approx 1 5 m Direct the instrument at the wall and switch on with the On Set key Activate the laser line with the On Set key Rotate the instrument and align it with the bottom of the plumb line Now read off the maximum deviation of the laser line from the top of the plumb line If the difference does not exceed 2 mm then the CLL 11 PLL 11 is within tole rance Checking the accuracy of the vertical plumbing of the PLL11 Place the Lock switch in the Unlocked gf position Checking the upper plumbing point Bl 7 7 B2 max 2 mm 1 5m im 2 L Yai Checking the lower plumbing point Alr y 1 gt 1 5m
9. e with detector gt 100 ft Levelling accuracy 5m 1 5mm 1mm Levelling accuracy 16 ft 1 16 0 04 in Self levelling range 4 0 5 Self levelling range 4 0 5 Accuracy of plumbing poit 5m 1 5mm Accuracy of plumbing point 16 ft 1 16 Accuracy of horizontal line 5 m 1 5mm Accuracy of horizontal line 16 ft 1 16 Vertical accuracy 3m Vertical accuracy 10 ft u line length 0 75 mm line length 1 32 Beam divergence lt 180 Beam divergence lt 180 Number of laser dots 4 Number of laser dots 4 Number of laser lines 2 Number of laser lines 2 vertical vertical anti horizontal vertical horizontal vertical Beam direction up down horizontal Beam direction up down horizontal right left right left Laser type 635 nm laser class II Laser type 635 nm laser class II Batteries Type Py R EN Batteries Type ay R ay Protection class spray water dust IP 54 Protection class spray water dust IP 54 Operating temperature 10 C to 40 C Operating temperature 14 F to 104 F Storage temperature 25 C to 70 C Storage temperature 13 F to 158 F Dimensions H x D x W 108 x 115 x 76 mm Dimensions H x D x W 4 2 x 4 5 x 3 0 in Weight without batteries 485g Weight without batteries 17 1 oz Tripod thread 1 4 Tripod thread 1 4 depending on lighting conditions depending on lighting conditions Technical data PLL 11 CLL 11 me Technical data LLE 11 Safety instructions D The person r
10. esponsible for the instrument must ensure ELE that all users understand these directions and adhere to Sensitivity switch 1mm 0 04 them able 3mm 0 12inch Detection field length 42 mm 1 65inch Symbols used Protection IP54 The symbols used have the following meanings Operation tempera WARNING p P 10 C 50 C 14F 122 F Indicates a potentially hazardous situation or an ture unintended use which if not avoided will result in death Storage temperature 20 70 C 4 F 158 F or serious injury Battery type 1x 6LR61 9V CAUTION Di 147 5 x 75 5 x 5 8x2 9x Indicates a potentially hazardous situation or an mensions 29 5 mm 1 2 inch unintended use which if not avoided may result in minor Weight with batteries 260 g 9 10z injury and or appreciable material financial and environmental damage All rights reserved for changes on drawings descrip Cg Important paragraphs which must be adhered tions and technical data to in practice as they enable the product to be used in a technically correct and efficient manner Permitted use e Projection of horizontal and vertical laser lines and laser dots Prohibited use Using the product without instruction Using outside the stated limits rag Technical data LLE 11 Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screwdri vers etc as
11. far as not specifically permitted for certain cases Carrying out modification or conversion of the product Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site Limits of use CE Refer to section Technical data The CLL 11 PLL 11 is designed for use in areas permanently habitable by humans Do not use the product in explosion hazardous areas or in aggressive environments Areas of responsibility Responsibilities of the manufacturer of the original equipment Adolf Wirth GmbH amp Co KG D 74650 Kiinzelsau for short W rth e Wirth is responsible for supplying the device inclu ding the User Manual in a completely safe condi tion e Wirth is not responsible for third party accessories Responsibilities of the person in charge of the instrument The person in charge of the instrument has the following duties To understand the safety instructions on the product and the instructions in the User Manual e Tobe familiar with local safety regulations relating to accident prevention Hazards in use CAUTION Watch out for erroneous measurements if the inst rument is defective or if it has been dropped or has been misused or modified CE Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements Refer to section Checking the accuracy WARNING Flat b
12. level of the beeper Sensitivity key switch sensitivity t 1mm 3mm OOQCOOQ DOOO Operation LLE 11 a a Care and advice on operation Warranty Do not immerse the instrument in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solvents Treat the instrument with the same care that you would apply to binoculars or a camera Dropping or violent shaking of the instrument may damage it Check the instrument for any damage before using it Check the levelling accuracy of the instrument regularly Transport To safely transport the instrument set the Lock switch to Locked For this W rth tool we provide a warranty in accordance with statutory country specific regulations from the date of purchase proof of purchase by invoice or delivery note Damage that has occurred will be corrected by replacement or repair Damage caused by normal wear overloading or improper handling is excluded from the warranty Claims can only be accepted if the power tool is sent undisassembled to a W rth branch office your Wirth sales representative or a customer service agent for W rth compressed air and power tools fo Care and advice on operation Technical dataPLL11 CLL 11 __ PLL 11 CLL 11 PLL 11 CLL 11 Range up to 15 m Range up to 50 ft Range with detector gt 30m Rang