image

Contents

1. cation Switch points adjustable Switching value Switching value Qmax m h FPS 2100 P FPS 2200 P FPS 3100 P FPS 3200 P PIPE recommended FPS 5100 P FPS 5200 P FPS 6100 P FPS 6200 P diameter H O m h water m h water Ca eo ca 28 ss osma os Co eo naar ora ose m2 pe se BT a mc 11 4 27 7 14 7 29 0 4 9 17 1 11 3 19 1 6 1 17 3 8 0 18 4 3 3 11 6 7 7 13 0 22 9 53 3 28 4 55 6 3 7 34 0 22 4 37 9 9 3 25 2 12 9 26 8 5 0 17 5 11 5 19 6 35 9 81 7 43 1 85 1 13 6 47 6 31 5 53 1 150 120 12 3 30 6 16 8 32 7 6 1 21 4 14 1 23 9 72 6 165 7 85 1 172 5 25 7 90 1 59 6 100 7 38 6 90 8 46 5 94 2 21 7 55 3 36 5 61 8 For DN 25 a fitting is required in which the paddle can move freely The values in brackets apply when using the supplied long paddle which is shortened for service in NW 100 to NW 150 and which must be mounted together with the three short paddles i Switching value L h water Model diameter decreasing flow FPS 1115P 15 174 846 480 948 FPS 1120P 20 138 768 408 858 page 4 FPS P K01 0712 FPS 5 Operating Principle The KOBOLD flow monitor FPS operates according to the proven paddle bellows principle The flowing medium acts on the paddle thus actuating a microswitch Switching point can be freely adjusted and the device ma
2. OBOLD uU O Operating Instructions for Paddle Bellows Flow Monitor Model FPS P FPS 1 Contents T Conten ee ee Ae ae Aa 2 De NON ee ee ee 3 s Instr mentEInSpeelon rn a un 3 A REJUN USO mas nal tea ee an ae ee a cece wines ae cae eee a 4 5 Operating PrinCiple ccccccccccecceecseeseeceeeeeeceeeeeneeeeeeeeseeceeeeseneetseeaueneeeseeees 5 6 Mechanical Connection ssnin a A a A E A 5 T A 6104 6 2 e 0 ay Arey es e g etree meee ene ae et ree er ee OR ee OR eR eRe ee ee ee 6 6 SENO tHe LIMIE CONlacl nennen sbednaseeeesecueebseoeseecseds 6 9 Maintenance Eee eee 6 10 Technical Information ccc cece ec ececececececeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneennenaes 7 1i Order CodeS ee ce eT eae ae re ere re er T DMI OS aaa a a 8 13 Declaration OF GOMIOFIMANGCES 2 22540 Sternen seta iiaiai iieiaei aiei rrisi 9 Manufactured and sold by Kobold Messring GmbH Nordring 22 24 D 65719 Hofheim Tel 49 0 6192 2990 Fax 49 0 6192 23398 E Mail info de kobold com Internet www kobold com page 2 FPS P K01 0712 FPS 2 Note Please read these operating instructions before unpacking and putting the unit into operation Follow the instructions precisely as described herein The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health amp Safety and prevention of accidents W
3. S 58 bellows of bronze paddle of st steel 1 4401 T piece steel zinc plated Stainless steel design stainless steel 1 4541 paddle of st steel 1 4401 Max medium temperature 40 to 120 C Max ambient temperature 35 to 65 C Max allowed pressure brass 11 bar stainless steel 30 bar Max pressure loss approximately 0 01 0 03 bar Inlet and outlet pipe section min 5 times nominal pipe size Electrical details Dust proof microswitch as single pole changeover contact Switching voltage max 24 250 Vac Switching current max 8 A inductive load max 15 A resistive load Case ABS Protection type IP 65 11 Order Codes Nominal Standard switching range Special switching range pipe m h Water m h Water Order number m h Water m h Water Order number size falling rising Brass St steel falling rising Brass St steel Er SEE E EESZEDUE BE DU SERSSZONE OO ae ee on gt ACen 2 S ann 11 4 27 7 14 7 29 0 FPS 5100 P FPS 5200 P 4 9 17 1 11 3 19 1 FPS 6100 P FPS 6200 P Con 1 NPT Con 1 NPT Con 1 NPT Con NPT 9 3 25 2 12 9 26 8 5 0 17 5 11 5 19 6 12 3 30 6 16 8 32 7 6 1 21 4 14 1 23 9 38 6 90 8 46 5 94 2 21 7 55 3 36 5 61 8 l h water l h water 174 846 480 948 FPS 1115P 138 768 408 858 FPS 1120P _ For DN 25 a fitting required in which the paddle can move freely The values in brackets apply when using the supplied long paddle which is shortened for s
4. e Limit Contact A suitable filter must be connected upstream for soiled media This applies especially to fibrous soiling FPS P K01 0712 page 5 FPS 7 Electrical Connection e Make sure that the voltage and current values in your plant do not exceed the respective voltage and current values specified for the flow monitor Make sure that the electrical supply lines are de energized Remove the flow monitor housing by undoing the four screws Connect the flow monitor as shown in the wiring diagram Red white opens if the flow rate drops to the set value Red blue close simultaneously and can be used as a signal contact The unit is ready for operation when you have connected your external devices to the limit contact rosso red blu blue tol el 8 Setting the Limit Contact The units are delivered with an adjustable microswitch The contact is a changeover contact that can be wired for use as a N O or N C contact The units are set to the minimum switch off value at the factory The switch off value can be set to a higher value by rotating the range screw clockwise 9 Maintenance In cases where the flow medium is uncontaminated the FPS will remain maintenance free Large dirt particles can block the beam Depending on the amount of dirt present in the medium we recommend that the Instrument is checked at regular intervals page 6 FPS P K01 0712 FPS 10 Technical Information Brass design M
5. ervice in NW 100 to NW 150 and which must be mounted with the three short paddles FPS P K01 0712 page 7 FPS 12 Dimensions M20 T Mounting Instructions page 8 FPS P K01 0712 FPS 13 Declaration of Conformance We KOBOLD Messring GmbH Hofheim Ts Germany declare under our sole responsibility that the product Paddle Bellows Flow Monitor Model FPS to which this declaration relates is in conformity with the standards noted below EN 55014 Suppression of radio disturbances caused by electrical appliances and systems EN 61000 4 2 IEC 1000 4 2 Electrostatic discharge immunity test ESD EN 61000 4 4 IEC 1000 4 4 Electrical fast transient burst immunity test BURST EN 61000 4 5 IEC 801 4 Surge immunity test EN 60355 1 Safety requirements for electr equipment for measurement control and laboratory use following the provision of European Directives 2004 108 EC 2006 95 EC 97 23 EG PED Diagram 8 Pipes Liquids Group 1 dangerous fluids Module D mark CE0093 Notified body Germanischer Lloyd Germany Hofheim 13 April 2012 ALP ppa Nun H Peters M Wenzel General Manager Proxy Holder FPS P K01 0712 page 9
6. hen used in machines the measuring unit should be used only when the machines fulfil the EWG machine guidelines as per PED 97 23 EG for FPS 11 In acc with Article 3 Paragraph 3 Sound Engineering Practice of the PED 97 23 EC no CE mark Diagram 8 Pipe Group 1 dangerous fluids 3 Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In case of damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery The standard delivery includes e Flow Monitor Model FPS e Operating Instructions FPS P K01 0712 page 3 FPS 4 Regulation Use The model FPS is installed for monitoring flow of liquid medias in pipes with dia meter between 1 2 and 8 The instrument is provided with an adjustable limit switch Only media may be monitored which does not affect the materials used in the in strument This device shall not be used in hazardous areas or for flammable liquids Material combinations FPS 1115 P FPS 1120 P FPS 2100 P FPS 3100 P FPS 2200 P FPS 3200 P FPS 5100 P FPS 6100 P FPS 5200 P FPS 6200 P Housing Basic plate zinc plated cover ABS Paddle st steel Lever Arm brass Ms 58 brass Ms 58 st steel AISI 316 L Connection brass Ms 58 brass Ms 58 st steel AISI 316 L Teaco
7. ted to different nominal pipe sizes by means of the replaceable paddle in conjunction with the additional adjustment features The electrical device section is separated hermetically from the process fluid by means of a bellows The special version of the flow monitor has been specially designed for minimum switching values See table for switching values The devices can be installed in any position 6 Mechanical Connection Before installation e Please ensure whether the actual flow matches the switching range of the instrument e Please ensure whether the allowable maximum operating pressure and operating temperature of the instruments will not be exceeded e Please ensure whether a straight run of 5 x pipe diameters at inlet and outlet is being observed Instal lation PADDLES models without T pipe fitting Select the paddle to suit the PADDLES pipe internal diameter To ensure stability the shorter paddle should always be left on Make sure that the paddle can move freely in the pipeline and that it does not stick to the pipe wall 161 5 Using sealing tape screw the flow monitor into a T piece according to DIN 2950 with 1 outlet The arrow on the housing must point in the direction of flow The unit can be fitted in any position If the unit is installed in a vertical pipe the weight of the paddle and the lever must be compensated with the range screw This leads to changes in switching values see Sec Setting Th