User manual MP15 - Dosiflex Complet set

image

Contents

1. MP15 Dosiflex User manual Serigstad R s r o Pod Z mkem 105 262 03 Nov Kn n Sudovice Czech Republic Tel 420 314 003 103 Mob 420 776 075 121 www serigstad cz REV 15 05 2011 ISO 9001 REV 15 05 2011 Presentation Thank you for your trust you expressed in our company by having bought the application device DOSIFLEX Our product meets the most rigorous regulations Perfect function and life can be achieved by proper assembly and maintenance Read instructions for use carefully before use Serigstad CR s r o Warning safety above all alid safety regulations apply o using acids and other aggres sive substances se protective aids enclosed 12 Volt DC Fuse 13A Product is tested by folowing regulation EN50081 1 2 EN50011B EN50082 1 EN61000 4 2 3 4 level 3 2 years warranty time EU 89 392 REV 15 05 2011 Connection CAUTION Cables are labelled and Spare fuse 1s found inside this Power Box for the case of re versal of poles and thus interruption of the fuse The product can be brought into operation by operating the main switch This switch can also be used if the soft ware becomes blocked for any reason In such a case turn off the main switch wait for 5 seconds and turn it on again Should lengthening of the supply cable be necessary use the cross section of 2x4 REV 15 05 2011 Fuse Back up fuse REV 15 05 2011 Operation
2. ast preset value It is thus possible to operate in the emergency mode and continue working The pump supplies the last preset volume in l min This value is used as informative only for possible control of the volume sup plied Output Shows engine load If failure of the flow indicator occurs the pump can be controlled us ing this mode Tank Actual This value shows how much liquid remains in the tank Counts down the volume based on the value preset as the tank volume REV 15 05 2011 Tank total volume supplied during a longer period is recorded here The processor can count up to 1999 litres Upon exceeding this value the check light switches on Tank total and the counter start count ing from zero again If an amount higher than 1999 litres must be recorded it is possible to continue and add 1999 litres to the value on the display In such a case the Tank total check light is on It means that the actual value is 1999 the value shown on the display To reset this value hold the button STORE for 3 seconds Tank setup Is used to preset the actual tank volume Tank volume up to 1999 litres can be set The present tank volume can be stored in the memory by pressing the button STORE Upon holding down the button add detract the counter starts to count faster The value of litres 1s increased in increments of ten REV 15 05 2011 Remote control The left connector is used for remote control Attach the remo
3. ng The frequency can be reduced in the ratio 1 4 16 3 Time base to count flow indicator impulses flow calibration The time base amount given by the flow indicator can be changed using UP or DOWN in the range 21 to 99 value on the display thus correcting the flow value measured by the flow indicator The value 60 corresponds precisely to the value measured according to information of the flow indicator manufacturer The value displayed can be changed using the buttons UP DOWN The setting can be stored by pressing the button STORE whereby the servicing mode is terminated as well and the unit switches into the normal mode REV 15 05 2011 Connection 12V s _N Remote switch Nozzles REV 15 05 2011 Here you can place metal nozzless 2 peaces REV 15 05 2011
4. of the DOSIFLEX control Flow l min Flow l min Output Engine load Tank actual Tank status Tank total Shows total volume filled Tank setup Tank size setup OFF LINE sviti v norm ln m re imu On if the pump is controlled by a superior control unit a computer sensor etc STORE VIEW ad o sara START STOP oO NJ Functions switching series pumps In combination JSwitches the pump on ith other pumps provides ll performance upon hold and off Up ng the button Storing of preset values in the memory Down REV 15 05 2011 Upon switching on the display test is performed This procedure takes about 3 seconds After the test the value 00 appears on the display Switch on Start simply and the pump starts Information appears on the display showing the flow in l min Press the arrow up or down to control the volume of liquid supplied Flow l min the display shows the flow volume in l min If the blinking value 00 appears on the display the pump stops At the same time an audio signal sounds This means that there is no more liquid in the tank and it must be refilled or the barrel must be replaced However it can also mean a failure such as a broken or squashed hose or faulty flow indicator If the flow indicator does not work anymore and the pump cannot be turned on it can be switched in the Output mode using VIEW In this mode the pump works under any circumstances The value stops on the l
5. te control cable to this connector At the end connect the cables to the switch Place a mechanic or magnetic switch on the movable part of the engine thus stopping or starting the pump Control levers are used most often or raising the collector in the case of cutters etc The very switch is used to stop the pump This means that the pump can be switched on by pressing the button START STOP and switched off and on again using the remote switch Upon finishing using of the remote switch the pump can be switched off using the button The left connector is START STOP used to connect the The right connector is used to connect control unit DOSIFLEX REV 15 05 2011 Servicing mode The PWM output frequency can be set in the servicing mode Furthermore the flow value can be recalibrated according to the actual measured value caused by the difference in elevation size of nozzles or liquid density Is used only if the values given by the pump differ significantly from the actual volume How to enter the servicing mode stop the unit by pressing START STOP Press and hold down the buttons UPand DOWN simultaneously The display signals the blinking value 00 and at the same time the diode ONLINE starts blinking Attendance by pressing the button START STOP the pump starts operating at the speed preset as last By pressing the button VIEW the display mode can be switched as follows I Flow 2 PWM frequency setti