1. Creative Lighting Solutions www cls led com CLS RGB LED PAR 56 V3 Polish 2 SAFETY INFORMATION Warning This product is for professional use only Read this manual before powering up or installing the CLS RGB LED PAR 56 V3 Follow the instruc tions listed below and observe all warnings in this manual Protection from electric shock e Disconnect the power supply from AC power before installation dismounting or maintenance of the unit e Make sure all connectors are connected properly e Use only a source of AC power that complies with local building and electrical codes e Do not expose the unit to rain or moisture e Refer all service to a qualified technician Protection from burns and fire e Provide a clearance of at least 50 mm around the unit e Do not install the RGB LED PAR V3 near to a heat source e Do not install the RGB LED PAR V3 in a corrosive flammable or explosive area e Do not modify the RGB LED PAR V3 or install other than genuine parts e Do not operate the unit if the ambient temperature exceeds 50 C e Operate in a well ventilated area Protection from damage due to falls e Verify that all covers and mounting hardware is securely fastened e Block access below the work area whenever installing or removing the unit 3 INSTALLATION This section describes in general terms how to install the CLS RGB LED PAR 56 V3 and how to connect it to a DMX data link 3 1 Installing the CLS RGB LED PAR 56 V3 The CLS
2. RGB LED PAR 56 V3 can be installed in different ways You can support it on a shelf or mount it by using the mounting hole 3 2 Data linking multiple CLS RGB LED PAR 56 V3 You need to create a data link if you want to control one or more CLS RGB LED PAR 56 V3 via a DMX controller The CLS RGB LED PAR 56 V3 can be data linked by using the XLR 3 input and output connectors at the back of the unit To set up a data link you have to take the following steps e Disconnect all the units from the AC supply e Connect the XLR 3 female connector of the first CLS RGB LED PAR 56 V3 to a DMX extension cable Connect the other end of the DMX cable to the XLR 3 male of the next CLS RGB LED PAR 56 V3 You can use CLS DMX cables for this purpose e Continue connecting CLS RGB LED PAR 56 V3 in this daisy chain way e A maximum of 32 units can be connected in this way Creative Lighting Solutions 4 DMX OPERATION 4 1 3 channel DMX Operation With 3 channel DMX operation you need 3 DMX channels to control the CLS RGB LED PAR 56 V3 First set the function switches to DMX 3 channel operation pi 2 3 Je Mode T E DMX 3 channel operation i off Now you can give the CLS RGB LED PAR56 V3 a DMX adress with the selection switches CEEE Ps PJ J re cn DMX address 174 alejslajs e 7 s o i0 A E E DMX address 36 DMX address 348 afelejals e 7 es o i0 afelalalsje 7 s o to E mT A E E E The functions of the 3 channels are Channel Funct
3. changes with 1 master and maximum 3 slaves set the selection switches from the master on the right position ee I ae eee ee ee Py ff pod Fading colour changes The selection switches of the slaves must be off 5 5 Stepping colour changes For stepping colour changes with 1 master and maximum 3 slaves set the selection switches from the master on the right position dedege sis 7 pee ro Function LL J stepping cotour changes The selection switches of the slaves must be off a Creative Lighting Solutions Control signal Working temperature Housing LIST OF SYMBOLS 4x4 cm DMX 512 1990 0 to 50 C High temperature powder coated steel item nr 875550 item nr 875552 Polished steel Protection class One two or three Application area Indoor or outdoor Application area Floor wall or ceiling Swivel Fixture is horizontally rotatable indicated in degrees Swivel Fixture is vertically rotatable indicated in degrees Multiple connection Possiblities on a fixture Installation depth In centimeters Mounting hole In centimeters Driver Excl Cable length Maximum cable attached on the fixture in centimeters Driver Inclusive or exclusive Weight In gram kilogram Pressure Maximum pressure on the fixture per kg cm Lifespan Of the light source in hours Curve Minimal bending curve in centimeters LED pitch Pitch between the
4. CLS Manuals CLS RGB LED PAR 56 V3 Polish Creative Lighting Solutions CLS RGB LED Par 56 V3 Polish So Creative Lighting Solutions version 1 3 August 2009 www cls led com 1 INTRODUCTION Thank you for selecting the CLS RGB LED PAR 56 V3 with 512 DMX channels The CLS RGB LED PAR 56 V3 is a universal DMX controlled luminairy that uses 151 5mm LEDs to create an even light output The CLS RGB LED PAR 56 V3 works on an input voltage of 100 240 VAC Available RGB LED Pars V3 e CLS RGB LED Par 56 V3 e CLS RGB LED Par 56 V3 Polish The CLS RGB LED PAR 56 V3 features e 100 240 VAC input e DMX input 3 5 channels e Auto change mode e Stand alone or DMX 512 controllable e Dip switches e Manual setting e Indoor use only Included items item nr 875550 item nr 875552 The CLS RGB LED PAR 56 V3 is shipped in one package containing the following items e 1 RGB LED PAR 56 V3 e 1 User manual e 1 Filter frame Optional Accessories e CLS DMX controller ACX60 60 DMX channels e CLS DMX cable 0 8 meters e CLS DMX cable 1 5 meters e CLS DMX cable 3 0 meters e CLS DMX cable 5 0 meters e CLS DMX cable 10 0 meters e CLS DMX cable 15 0 meters e CLS DMX cable 20 0 meters item nr 707030 item nr 911200 item nr 911201 item nr 911203 item nr 911205 item nr 911206 item nr 911207 item nr 911209 ON NN ON NN _ Am Note It is important to read this manual before you install this product ey
5. LEDs in millimeters 2007 CLS LED BV All rights reserved Information subject to change without notice CLS LED BV and all affiliated companies disclaim liability for injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual No part of this manual may be reproduced in any form or by any means without permission in writ ing from CLS LED BV Other legal information can be found in our General conditions to be found on the back of your CLS LED BV invoice or on our website www cls led com Conditions pdf www cls led com
6. f this program by a potentiometer or by music TECHNICAL SPECIFICATIONS Power supply Voltage 100 240 VAC Power consumption Max 18 VA Primary fuse 2 5A Fast Secondary fuse 100 mAF Weight 1 2 kg Dimensions 220 x 210 x 220 mm hxwxd without bracket Dimensions filter frame 198 x 198 mm hxw Control in amp output XLR 3 pole male female Control cable 120 ohm DMX cable Pf oy de Stand alone operation 5 3 Colour changing with 1 Master and maximum 3 Slaves With this mode you can create a lightshow without a DMX controller 1 CLS RGB LED PAR 56 V3 must set as master and all other CLS LED PARs as slave units dip switch on Speed control by music dip switch off Speed control by potentiometer dip switch on Speed control by music dip switch off Speed control by potentiometer Stand alone master operation And set all other CLS RGB LED PAR 56 V3 to slave operation aege fe Mode S Stand alone slave operation All slaves must be set with a DMX address with the selection switches Every unit needs 5 channels so the first slave must be set on address 6 the second on 11 and the third on 16 Connect the master with a DMX cable to the first slave connect the first slave with a DMX cable to the second slave and connect the second slave with a DMX cable to the third slave Now you can choose how you want to change the colours Fading or stepping 5 4 Fading colour changes For fading colour
7. ion 4 www cls led com CLS RGB LED PAR 56 V3 Polish 4 2 5 channel DMX operation a gees affa 4 mode With 5 channel DMX operation you need 5 DMX channels to control the CLS RGB LED PAR 56 V3 aa ee a A a E HH First set the function switches to Static Colour Mode First set the function switches to DMX 5 channel operation afe a a mode a Now create a colour you wishes with the selection switches ca B DMX 5 channel operation 5 channel operation z off a2 3 4 s e 7 e 9 10 colour Brightness zz off Now you can give the CLS RGB LED PAR 56 V3 a DMX address with the selection switches See table on page 3 oes W conta e re am Peso ange AS sped conor 82 255 coour ange cas speed amor C os fe SSS S CO i J W e EE Bee eee ERR Bee ow fesa ooo CEC CE 51 255 sped conoi by uni poeroen 5 STAND ALONE OPERATION Sd d BE o f CO o osm en osm HECHE 100 BLUE 100 RKI ATTENTION BEFORE SETTING A STAND ALONE MODE FIRST UNPLUG THE Example EXTERNAL DMX CABLE TO A DMX CONTROLLER YOU DON T NEED Magenta Yellow Cyan A DMX CONTROLLER FOR THESE MODES J y ade dejelste izlee fde tslalsielzjejojio afe fslalsie l7 e ts wo 9 Creative Lighting Solutions ka 6 www cls led com CLS RGB LED PAR 56 V3 Polish 5 2 Colour changing With this mode the CLS RGB LED PAR 56 V3 will show you a stepping colour changing program You can set the speed o