1. Figure 3 Mounting Bracket Location 2 Cable Entry Exit Cables enter and exit through conduit fittings and or cord grips on the bottom of the enclosure Input wires are routed through either cord grips 1 per channel or a 1 conduit fitting All output wires are routed through a 1 conduit fitting A 1 2 conduit fitting is provided for an AC power entry If you are running conduit to your switch box ensure the conduit cable entry enters from the bottom of the enclosure when mounted Stainless Steel cord grip option is offered for the XE250 Series for additional protection where plastic cord grips will not suffice Sa 222 We ei Power Cable Cable Outputs Input Cable Input From Sensors Figure 4 Cable Entry Exit Layout MNX10030 REV A 9 15 2011 NOTE To ensure moisture will not flow into the Enclosure a hole should be drilled at the lowest point in the conduit to provide drainage for any moisture Correct Incorrect Drill Drain Hole Here Figure 5 Conduit Entry 3 Grounding of the Enclosure Ensure the shield ground wire on the XE150 250 Series Enclosure is connected to earth ground Note For XE150 Series Enclosures the customer is required to supply wire from ground to shield ground lug located on the outside of the enclosure Note XE250 Series Enclosures are internally grounded to the enclosure Shield Ground Lug Figure 6 XE150 Series Location of Shield Ground Lug MNX10030 R
2. PROTECTION amp RELIABILITY OPTIMIZATION INSTRUMENTS Product Manual MNX10030 REVA MODEL XE150 250 Series Enclosure for SC200 Series Premium Signal Conditioners Contents Section I Overview Introducti OM E A AE A E T E DESCHPUON esaea r E a EESE ERRi XE150 250 Series Model Selection cccccceeee eee eeees SV CCIIGAIONS iacenissacaoscdeseiecncut a aS Section Installation Mounting Electrical Section Operatio Connections 0sssseeeeeeee ekte kk ERE Waventiededecdbind II n Signal Conditioner Configuration ccc cece cece enna Operating Procedure aneres na EEEa Section I V Maintenance General Warranty Figures Figure 1 XE150 Series Selection Guide cccceccceeee eee e ee Figure 2 XE250 Series Selection Guide cceccceeeeee eee Figure 3 Mounting Bracket Location Figure 4 Cable Entry EXit ccccceeeeeeeseeeeeeeeeneseees Figure 6 XE150 Series Location of Shield Ground Lug Figure 7 XE250 Series Ground Wire Placement Figure 8 XE150T 250T Terminal Block Connections FIG UFFE 5 VCOACUIT EUY ixeew arte rr e Figure 9 XE150 250 Terminal Block Connections MNX10030 9 15 2011 REVA Section I Overview Introduction This document contains information on the operation installation and maintenance of
3. a 3 position terminal block and the XE150T 250T uses a 4 position terminal block XE150 250 Output Wiring XE150T 250T Output Wiring Terminal 1 Signal Terminal 1 Signal Terminal 2 Signal Terminal 2 Signal Terminal 3 Ground Terminal 3 Ground Terminal 4 Temperature Power AC power for the small enclosure and the large enclosures for both XE150 250 and XE1501T 250T enters the enclosure through a 2 conduit fitting Customer is required to wire the power directly to the power supply Note XE150 250 Series enclosures should be protected from electrostatic discharge voltage Voltage powering the enclosure should not exceed 240 Volts SENSOR X SENSOR X grr nent H er ff Bel AT o L gt Lat gamete 9 coil St piel el a 7 hems CE A Eier oa er r yt i ace Output Input SENSOR X SENSOR X a 1 O71 Kaa D sO 505020 est ef eles ry Se lt T kv 48 i G Figure 8 XE150T 250T Terminal Block Connections SENSOR X 4 20 mA Sensor Output SENSOR X kez a gt Figure 9 XE150 250 Terminal Block Connections MNX10030 REV A 9 15 2011 Section Ill Operation Signal Conditioner Configuration Refer to MNX10020 PRO Signal Conditioner Transmitter User Manual for configuration specifications and procedure for SC200 signal conditioners Once all wires are connected apply power to begin operatin
4. EV A 9 15 2011 Figure 7 XE250 Series Ground Wire Placement Electrical Connections Inputs Cables enter the enclosure through the designated entry option selected cord grips or conduit or custom user defined installed options All wires are connected to terminal blocks within the enclosure Standard XE150 250 enclosures uses a 3 position terminal block while XE150T 250T temperature variant XE150 250 uses a 4 position terminal block Sensor inputs for both the XE150 250 and XE150T 250T are located on the right side of the enclosure as indicated by the labeling Sensor Input XE150 250 Input Wiring XE150T 250T Input Wiring Terminal 1 Signal Terminal 1 Signal Terminal 2 Signal Terminal 2 Signal Terminal 3 Ground Terminal 3 Ground Terminal 4 Temperature Note If there is no sensor wired to the sensor input terminal the corresponding transmitter for that channel will not power on Be sure to power the system on AFTER the sensor has been connected Note If utilizing cord grips ensure that all cord grips are used Empty cord grips provide a path for contaminates to leak into the enclosure and cause malfunctions MNX10030 REV A 9 15 2011 Outputs The 4 20mA output of the XE150 250 and XE150T 250T are located on the left side of the enclosure as indicated by the labeling 4 20mA Output These terminal blocks follow the same scheme as the inputs Standard XE150 250 uses
5. Input onl _ 5 8 Channel amp 5 8 Channel p y 05 5 Channels 1 2 Conduit Fitting 06 6 Channels for power 1 8 Channel 07 7 Channels C Cord Grips 08 8 Channels 1 per Channel amp 1 2 Conduit Fitting for power S Stainless Steel Cord Grips 1 per Channel amp 1 2 Conduit Fitting for power Stainless Steel enclosure only Figure 2 XE250 Series Selection Guide MNX10030 REV A 9 15 2011 Specifications Environmental e Operating Temperature Range 15 F 10 C to 140 F 60 C o Note If internal temperature of XE150 250 Series Enclosure is to exceed 140F 60C a method of cooling the enclosure is required or overheating and damage to the system may result e Humidity Range 0 95 Relative Non Condensing Electrical e Power Input Range 100 VAC to 240 VAC 0 68 A 50 60 Hz Physical e Fiberglass Enclosure Dimensions o 1 to 4 Channel 12x10x6 IN 305x254x165 mm o 5 to 8 Channel 16x14x8 IN 406x356x210 mm e Stainless Steel Enclosure Dimensions o 1 to 4 Channel 12x10x7 IN 305x254x178 mm o 5 to 8 Channel 16x14x8 5 IN 406x356x216 mm Ratings e NEMA 4X Refer to MNX10020 PRO Signal Conditioner Transmitter User Manual for specific electrical performance and calibration instructions MNX10030 REV A 9 15 2011 Section Il Installation Mounting 1 Attach the enclosed mounting brackets to the NEMA enclosure at the predetermined locations if applicable
6. ed or non functional transmitter MNX10030 REV A 9 15 2011 Section IV Maintenance General There are no customer replaceable parts It should provide trouble free continuous service under normal operating conditions Warranty If any PRO product should ever fail we will repair or replace it at no charge as long as the product was not subjected to misuse natural disasters improper installation or modification which caused the defect CONTACT INFORMATION Connection Technology Center Inc CTC 7939 Rae Blvd Victor NY 14564 1 800 999 5290 US amp Canada 1 585 924 5900 International sales ctconline com www ctconline com MNX10030 REV A 9 15 2011
7. g the Signal Conditioner s Make sure the status light is indicating normal mode on each SC200 Operating Procedure To operate the Signal Conditioners inside the enclosure make sure that all wires are properly connected and then apply power CAUTION Make sure that power input does not exceed specified limits or damage to the system may result See Table 1 Calibration The Signal Conditioner is calibrated internally during power up The digital calibration eliminates the need for any adjustments to the Analog Output Indicators The LED on the front of the Signal Conditioner will indicate the status of the Signal Conditioner A constant bright LED indicates normal operating condition and a Flashing LED indicates an error has occurred STATE 1 Normal Mode Operation e LED is a Solid ON STATE 2 Error Detected e LED is flashing ON and OFF in 0 5 second intervals a e Errors can be due to o Input Sensor bias voltage lt 5 V Sensor is considered shorted o Input Sensor bias voltage gt 15 V Sensor is considered unconnected missing o Invalid configuration of switch settings MNX10030 REV A 9 15 2011 Portable Data Collector Interfacing In order to collect waveform data from the BNC jack on the Signal Conditioner using a portable data collector that supplies constant current power the data collector must be set so that power to the sensor is turned off Failure to do so may result in a damag
8. the XE150 250 Series Signal Conditioner Enclosure This manual is an overview of the system and references the specific component manuals User manuals are provided with the system for all configurable internal components Description The XE150 250 Series Signal Conditioner Enclosure is a turnkey solution coming fully populated with signal conditioners power supply and terminal blocks for sensor terminations The signal conditioners are already pre configured based on the customer s specific requirements Terminal blocks are provided for your sensor terminations These terminal blocks are pre wired to the signal conditioners and outputs from the signal conditioners are wired to terminal blocks for integration into PLC DCS systems Each signal conditioner utilizes screw terminals for the various input output options such as 20 to 32 VDC power input signal output outputs include both a 0 10 VDC output and a 4 20mA output and a temperature output in 0 1 2 VDC and sensor input vibration displacement and temperature inputs There is also a green indicator light Transducer Signal OK which illuminates when the sensor is properly connected to the transmitter and working correctly The power supply accepts input voltage of 100 240 VAC 68A amp 50 60 Hz and provides 24 VDC to the signal conditioners and sensors The power supply terminals include AC Input Terminals L amp N and Ground DC Output Terminals are utilized in providing po
9. wer to the vibration transmitters The output voltage of the power supply is 21 6 26 4 VDC Refer to MNX10020 PRO Signal Conditioner Transmitter User Manual for specific electrical performance and calibration instructions MNX10030 REV A 9 15 2011 XE150 250 Series Model Selection The XE150 250 Series system has multiple options available to customize to fit your specific requirements See Figures 1 amp 2 Ordering Information e l DO Temperature of Channels Enclosure Entry Enclosure Exit T Temp Vibration 01 1 Channel A None A None Input 02 2 Channels B 1 Conduit Fitting B 1 Conduit Fitting 03 3 Channels 1 4 Channel 1 4 Channel Blank Vibration 04 4 Channels 1 1 4 Conduit Fitting 1 1 4 Conduit Fitting Input only 05 5 Channels renee 5 8 Channel 06 6 Channels for power 1 8 Channel 07 7 Channels C Cord Grips 08 8 Channels 1 per Channel amp 1 2 Conduit Fitting for power Example Part Number XE1507T 06 AA Temperature vibration input 6 channels no entry or exit options Figure 1 XE150 Series Selection Guide Ordering Information e a of Channels Enclosure Entry Enclosure Exit T Temp Vibration 01 1 Channel A None A None Input 02 2 Channels B 1 Conduit Fitting B 1 Conduit Fitting 03 3 Channels 1 4 Channel 1 4 Channel Blank Vibration 04 4 Channels 11 4 Conduit Fitting 1 1 4 Conduit Fitting
Download Pdf Manuals
Related Search
Related Contents
MANUEL D`INSTRUCTIONS POMPE DE Pennington 100510035 Use and Care Manual N°81 - Saint-Etienne-de Burglar alarm central unit with communicator 5739 34/35 C4000 Standard/Advanced Guest Cortina fotoeléctrica de ABS Airbag System Votre Concept de Survie SIGMA Geoportal Manual TSFD Protection Toolkit Rayo Sónico - Radio Shack Operation Instruction for Deb 4000 Copyright © All rights reserved.