Home
TN-5816A/5818A Series Hardware Installation Guide
Contents
1. Connecting the Power Supplies The ToughNet TN 5816A 5818A series switches support two sets of power supplies power input 1 and power input 2 The M23 6 pin male connector on the TN 5816A 5818A s front panel is used for the dual power inputs Pinouts for the power input port on the TN 5816A 5818A PIN PWR Description Usage 1 PWR1 Live DC Connect PWR1 Live DC to the positive terminal when using a DC power source 2 PWR1 Neutral DC Connect PWR1 Neutral DC to the negative terminal when using a DC power source safety ground terminal for DC inputs PWR2 Neutral DC Connect PWR2 Neutral DC to the negative terminal when using a DC power source PWR2 Live DC Connect PWR2 Live DC to the positive terminal when using a DC power source STEP 1 Plug the power cord connector into the TN 5816A 5818A s power input port STEP 2 Screw in the nut on the power cord connector to the power input connector on the switch to ensure a tight connection oe Before connecting the TN 5816A 5818A to the power input make sure the power source voltage is stable 11 Connecting the Relay Outputs Each TN 5816A 5818A switch has two sets of relay outputs relay output 1 and relay output 2 The M12 A coded 5 pin male connector on the TN 5816A 5818A front panel is used for the two relay outputs Use a power cord with an M12 A coded 5 pin female connector t
2. STEP 1 Mounting the TN 5816A 5818A to a wall requires 4 screws Use the ToughNet switch as a guide to mark the correct positions of the 4 screws STEP 2 6 0 7 0 mm Use the 4 screws in the panel mounting kit If you would like to use your own screws make sure the screw head is between 6 0 mm and 7 0 mm in diameter and the shaft is less than 4 0 mm in lt 40mm diameter as shown at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the ToughNet switch between the wall and the screws NOTE Before tightening the screws into the wall make sure the screw head and shaft size are suitable by inserting the screw through one of the keyhole shaped apertures of the ToughNet switch STEP 3 Once the screws are fixed in the wall hang the ToughNet switch on the 4 screws through the large opening of the keyhole shaped apertures and then slide the switch downwards Tighten the four screws for added Stability NOTE To provide greater protection from vibrations and shocks use screws with shaft diameter between 6 0 mm and 7 0 mm and fix the ToughNet switch onto the wall directly through the large opening of the keyhole shaped apertures DIN Rail Mounting optional Use the optional DIN rail mounting kit DK DC50131 must be purchased separately to mount the TN 5816A 5818A on a 35 mm DIN rail STEP 1 Use 12 screws 6 screws per plate to attach the two DIN rail at
3. Ethernet cable with IP67 rated male 4 pin M12 D coded connector CBL M12 FF5P OPEN 100 IP67 1 meter M12 to 5 pin power cable with IP67 rated female 5 pin M12 A coded connector M12D 4P IP68 Field installable M12 D coded screw in connector male 4 pin IP68 rated M12A 5P IP68 Field installable M12 A coded screw in connector female 5 pin IP68 rated CAP M12F M Metal cap for M12 female connector DK DC50131 DIN rail mounting kit 50 x 131 mm TN 5816A Panel Layouts Top View N 20 N OUA W CPAs ic gt gt a S LA gt 5 i Rear View 1 Model name 2 Screw holes for panel mounting kit 3 Console port 4 Grounding screw 5 Relay output port 6 Power input voltage range indicator 7 Power input port male 6 pin shielded M23 connector 8 PWR1 LED for power input 1 9 PWR2 LED for power input 2 10 FAULT LED 11 MSTR HEAD LED for ring master or chain head 12 CPLR TAIL LED for ring coupler or chain tail 13 TP port s 10 100 Mbps LED 14 10 100BaseT X port female 4 pin shielded M12 connector with D coding 15 Waterproof vent 16 Product label 17 12 screw holes for DIN rail mounting kit 18 E2 LED Not used by the TN 5816 series 19 E1 LED Not used by the TN 5816 series 20 Ports 9 10 13 14 with relay bypass function 4 TN 5818A Panel Layouts Top View Pt ee eee 2 15 16 17 18 19 oo So e aE Rear View Model name Screw holes for panel mount
4. For use in pollution degree 2 environments A ATTENTION Safety First Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Please Read and Follow These Guidelines e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separated e Itis strongly advised that you label wiring for all devices in the system when necessary Grounding the ToughNet Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the grounding screw to the grounding surface prior to connecting devices F acdsee This product is intended to be mounted to a well grounded mounting surface such as a metal panel 10
5. M12 4 pin M Cross Over Cable Wiring Cross Over Cable Wiring ix ae ae me Rx 2 2 RX fe 2 ae Rx 4 Rx M12 4 pin M to M12 4 pin M Straight Through Cable Wiring Straight through Cable Wiring Txt 1 1 Rx Rx 2 2 ab Ss Tx 3 3 RX Rx 4 4 Tx M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring Cross Over Cable Wiring Txt 1 1 i Tx Rx 2 2 TX Tx 3 3 Rx Rx 4 6 Rx 13 M12 4 pin M to RJ45 8 pin Straight Through Cable Wiring Cross Over Cable Wiring Txt 1 4 Txt Rx 2 2 TX Tx 3 3 s Rx Rx 4 6 Rx Bypass Relay Function The TN 5816A 5818A is equipped with a bypass relay function When the switch is operating normally these bypass ports work in the same way as the other ports That is frame ingressions are processed and then forwarded If the switch stops working due to a power failure the bypass relay function will be triggered to ensure non stop data communication The figure below illustrates the bypass relay function For example if Switch B loses power then the two Gigabit ports will be bypassed through the relay circuit and the transmission line from Switch A to B and the transmission line from Switch B to C will interconnect automatically ensuring that power continues to be supplied The bypass relay function helps the network recover from single node failures in a linear topology Switch A Switch B Switch C Switch D T 2
6. power input ee agg 209 RICCO Power newt OFF Power is not being supplied to power O Input wen Pee poner OFF Power is not being supplied to power O Input wea Pee poner RED ON When the corresponding PORT alarm is Pv fete and a user configured event is triggered a the corresponding PORT alarm is not triggered or when the corresponding PORT alarm is disabled ON Blinki GREEN JON When the TN switch enables the coupling function to form a back up path in this Turbo Ring or it is the Tail of this E Chain OFF When the TN switch disables the T euin function of the Turbo Ring or it is not the Tail of the Turbo Chain CPLR TAIL Port LEDs T AMBER ON TP port s 10 Mbps link is active 10 100M Blinking Data is being transmitted at 10 Mbps PWR1 PWR2 FAULT MSTR HEAD p GREEN nn Blinking Data is being transmitted at 10 or 100 Mbps GREEN On TP port s 1000 Mbps link is active 45 Specifications Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 3ab for 1000BaseT X IEEE 802 3x for Flow Control IEEE 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP IEEE 802 1Q for VLAN Tagging IEEE 802 1p for Class of Service IEEE 802 1X for Authentication IEEE 802 3ad for Port Trunk with LACP Protocols IGMPv1 v2 GMRP GVRP SNMPv1 v2c v3 DHCP Server Client BootP TFTP SNTP SMTP RARP RMON HTTP HTTPS Telnet Syslog DHCP Option 66 67 82 SSH SNMP Inform
7. Modbus TCP LLDP IEEE 1588 PTP IPv6 RIP V1 V2 OSPF VRRP MIB II Ethernet like MIB P BRIDGE MIB Q BRIDGE MIB Bridge MIB RSTP MIB RMON MIB Group 1 2 3 9 Flow Control IEEE802 3x flow control back pressure flow control Priority Queues Available VLANs VLAN ID Range GMP Groups 256 Interface Fast Ethernet Front cabling M12 connector 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Gigabit Ethernet M12 X coded 8 pin connector 10 100 1000BaseT X auto negotiation speed F H duplex mode auto MDI MDI X connection and bypass relay function Console Port M12 A coding 5 pin male connector System LED Indicators PWR1 PWR2 FAULT MSTR HEAD CPLR TAIL Port LED Indicators 10 100M fast Ethernet port 10 100 1000M Gigabit Ethernet port Alarm Contact Two relay outputs in one M12 A coding 5 pin male connector with current carrying capacity of 1 A 30 VDC Power Requirements Input Voltage WV 24 to 110 VDC 16 8 to 137 5 VDC Input Current TN 5816ABP Series 1 1 A 24 VDC 0 23 A 110 VDC 1 24 A 24 VDC 0 26 A 110 VDC M23 6 pin male connector Protection 416 Reverse Polarity Present Protection Physical Characteristics Housing Metal IP54 protection with protective caps on unused ports Dimensions W x H x D TN 5816A Series 250 x 175 8 x 116 3 mm 9 84 x 6 92 x 4 58 in TN 5818A Series 250 x 181 4 x 116 3 mm 9 84 x 7 14 x 4 58 in TN 5818A Series 3160 g Ins
8. TN 5816A 5818A Series Hardware Installation Guide Moxa ToughNet Switch First Edition November 2014 MOXA 2014 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802058000010 Overview The ToughNet TN 5816A 5818A switches are high performance M12 Layer 3 Ethernet switches that support Layer 3 routing functionality to facilitate the deployment of applications across networks TN 5816A 5818A switches use M12 and other circular connectors to ensure tight robust connections and guarantee reliable operation against environmental disturbances such as vibration and shock TN 5816A 5818A switches support isolated power in the 24 to 110 VDC power input range allowing the same model to be used at different sites around the globe TN 5816A 5818A switches provide up to 16 Fast Ethernet M12 ports with 2 bypass relay ports and 2 Ethernet interface Gigabit ports with bypass relay functionality Furthermore with a 40 to 75 C operating temperature and IP54 rated waterproof enclosure the switches can be deployed in harsh environments The TN 5816A 5818A series Ethernet switches are compliant with essential sections of EN 50155 covering operating temperature power input voltage surge ESD and vibration as well as conformal coating and power insulation making the switches suitable for a variety of industrial applications Package Checklist Your ToughNet TN 5816A 5818A switch is shipped with the following
9. aa ypass ng Since the maximum segment length of category 5 twisted pair cable is 100 meters cable length must be considered when designing a network that utilizes this function For example the total length of the cables from Switch A to B and from B to C must be no more than 100 meters This way if the two adjacent nodes switch B and C for example encounter a power failure there will be no stoppage provided that the total length of the cables A to B B to C and C to D are no more than 100 meters The bypass relay function works best for networks with linear topologies ToughNet switches with bypass relay function are not recommended to be used in networks that employ ring topologies because network loops may occur when redundancy protocols such as RSTP or TurboRing are applied 14 LED Indicators Several LED indicators are located on the ToughNet switch s front panel The function of each LED is described in the table below LED Color __ State Description AMBER System LEDs PWR2 enabled and a user configured event is GREEN When the TN switch is either the Master Mop this Turbo Ring or the Head of this Turbo Chain linking When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and the Turbo Chain is broken When the TN switch is neither the Master of this Turbo Ring nor the Head of this Turbo Chain AMBER ON Power is being supplied to
10. ing kit Console port Grounding screw Relay output port Power input voltage range indicator Power input port male 5 pin shielded M23 connector PWR1 LED for power input 1 PWR2 LED for power input 2 FAULT LED MSTR HEAD LED for ring master or chain head CPLR TAIL LED for ring coupler or chain tail TP port s 10 100 Mbps LED 10 100BaseT X port female 4 pin shielded M12 connector with D coding Waterproof vent Product label 12 screw holes for DIN rail mounting kit E2 LED Down side E2 Gigabit port s 10 100 1000 Mbps LED E1 LED Down side E1 Gigabit port s 10 100 1000 Mbps LED za 20 Gigabit Ethernet port E1 corresponding to port 17 in the TN 5818A User s Manual ports 17 18 support relay bypass function 21 Gigabit Ethernet port E2 corresponding to port 18 in the TN 5818A User s Manual ports 17 18 support relay bypass function 22 Ports 9 10 13 14 with relay bypass function y ATTENTION DO NOT open or remove the vent 15 Once the seal has been removed the warranty will be invalid Ports including 3 5 and 14 that are not in use must be tightly covered with protective caps an optional accessory to ensure IP54 IP67 rated protection After the rotary switches 1 are set the protective cover must be properly affixed to ensure IP54 rated protection Mounting Dimensions unit mm TN 5816A Series 116 30 TN 5818A Series DIN RAIL KIT DIN RAIL KIT Panel Wall Mounting
11. items If any of these items is missing or damaged please contact your customer service representative for assistance e 1 Moxa ToughNet switch e M12 to DB9 console port cable e 2 protective caps for console and relay output ports e Panel mounting kit e CD ROM with user s manual Windows utility and SNMP MIB file e Hardware installation guide e Warranty card Features Anti Vibration Circular Connectors for Robust Links e M12 D coding 4 pin female connectors for Fast Ethernet 10 100BaseT X ports e M12 X coded 8 pin connector for Gigabit Ethernet 10 100 1000BaseT X ports e M12 A coding 5 pin male connectors for console and relay output e M23 6 pin male connector for power input Dual Isolated Power Inputs e 24 to 110 VDC 16 8 to 137 5 VDC isolated Designed for Industry specific Applications e Two Gigabit Ethernet ports to meet high bandwidth requirements e Bypass relay ensures non stop data communication in the event the switch stops working due to a power failure e EN 50155 50121 3 2 compliant See specs for details about compliance with specific chapters of EN 50155 e 40 to 75 C operating temperature range e IP54 rugged high strength case e Panel mounting or DIN rail mounting installation capability Recommended Optional Accessories CBL M23 FF6P Open BK 100 IP67 1 meter M23 to 6 pin power cable with IP67 rated female 6 pin M23 connector CBL M12D MM4P RJ45 100 IP67 1 meter M12 to RJ45 Cat 5E UTP
12. o connect the relay contacts You can purchase an M12 power cable from Moxa the model number is CBL M12 FF5P OPEN 100 IP67 Pinouts for the TN 5816A 5818A s relay output port PIN R O N C Not connected FAULT The two sets of relay contacts of the M12 A coded 5 pin male connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port Connection All TN 5816A 5818A models have 16 10 100BaseT X Ethernet ports 4 pin shielded M12 connector with D coding The 10 100TX ports located on the TN 5816A 5818A front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables 10 100BaseT X Port Pinouts PIN TX Housing shield 12 10 100 1000BaseT X M12 8 pin Port Pinouts PIN Con 2 3 g El a 3 4 5 G 8 M12 4 pin M to
13. tachment plates to the rear panel of the switch STEP 2 If the spring loaded bracket is locked in place push the recessed button to release it Once released you should feel some resistance from the spring as you slide the bracket up and down a few millimeters in each direction STEP 3 STEP 4 Position the ToughNet switch on the Swing the switch down fully onto DIN rail tilted so the clamps hook the DIN rail until both clamps over the top edge of the rail completely latch Recessed button Spring loaded bracket DIN Rail DIN Rail To remove the Moxa ToughNet Switch from the DIN rail use a screwdriver to pull out the two spring loaded brackets from the bottom until they are fixed in a locked position Then reverse Steps 3 and 4 above p a f N A DIN Rail 3 Wiring Requirements A ARNG Turn the power off before disconnecting modules or wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make sure you are using the correct voltage Do NOT use a voltage greater than what is specified on the product label These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006 95 EC and 2004 108 EC 7 Va Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa switch This device has UL 508 approval Use copper conductors only 60 to 75 C and tighten to 4 5 pound inches
14. tallation Panel mounting DIN Rail mounting with optional kit Operating Temperature Storage Temperature Operating Humidity 5 to 95 non condensing EMS EN61000 4 2 ESD level 3 EN61000 4 3 RS level 4 EN61000 4 4 EFT level 3 EN61000 4 5 Surge level 3 EN61000 4 6 CS level 3 EN61000 4 8 EN61000 4 11 1EC61373 Freefall IEC60068 2 32 1EC61373 Note Please check Moxa s website for the most up to date certification status WARRANTY 5 years Details See www moxa com warranty Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 17