1. HEAT ALARM 120VAC 60Hz Wire in HD6135FB with 9V Battery Backup The BRK Brands Inc Model Number HD6135FB is a wire in 120V AC 60Hz single and or multiple station heat alarm designed to supplement smoke alarms in residential and institutional applications including sleeping rooms of hospitals O hotels motels dormitories and other multi family dwellings as defined in L 35 FIXED amp standard NFPA 101 Models HD6135FB complies with UL539 CSFM NFPA 72 RATE OF RISE HUD FHA and other agencies that model their codes after the above agencies They meet building codes where AC and AC DC with Silence heat alarms are Microprocessor controlled Features required The alarms are interconnectable with up to 18 devices of which 12 can Fixed Rate and Rate of Rise be smoke alarms This heat alarm is not a smoke alarm nor has it been temperature sensing allows unit to designated a life safety device alarm prior to reaching the fixed S temperature setting of 135 F BRK Electronics HD6135FB is designed to give reliable early warning of heat from fire It is recommended for garages crawl spaces bathrooms kitchens laundry rooms or other applications not suitable for smoke alarm installations It IR REMOTE CONTROL features exclusive IR remote control test silence that can be activated by most Can test or silence thealarm with most household remote controls The unit contains a thermistor that senses heat and household remote
2. controls will alarm when either the temperature reaches 135 F or when a rate of rise of 15 F minute is sensed by the microprocessor This feature enables a more rapid LATCHING ALARM response to a potential fire The unit has an 85dB horn a 9V battery backup power supply an easy access side load battery drawer This alarm features INDICATOR Alarm Latch Easily identifies initiating alarm even after alarm condition has subsided Low Battery Silence Temporarily silence the low battery chirp for up to eight hours Alarm Silence Silence alarm for several minutes Two locking features are provided to prevent battery theft and or theft of the unit Connection to AC power is made with a Quick Connect wiring harness Installation is quick easy and cost effective Remembers which unit initiated an alarm SINGLE BUTTON TEST SILENCE Silences and tests alarm with a single button p 1 TWO LOCKING qa FEATURES i Pins are provided to lock battery drawer st pier and or alarm to base Perfect for Fir CAE Pk apartment dormitory or hotel are a applications i A i Z gt Pa yore TES iV D hisy IONIZATION Standard HD6135FB MOUNTING TOP VIEW BRACKET SIDE VIEW bee J The heat alarm shall be a BRK Model HD6135FB and shall provide at a minimum the following features and functions 1 A thermistor and microprocessor capable of sensing and alarming at a 135 F fixed temperature level and a 15 F m
3. in rate of rise tempertaure change 2 The unit shall be capable of self restoring 3 Powered by 120V AC 60Hz and have a monitored 9V battery backup and a solid State piezo horn rated at 85dB at 10 ft 4 Avisual green LED power on indicator to confirm unit is receiving power or is in alarm 5 A full function test button should check all alarm functions by simulating a smoke condition causing the unit to alarm 6 Silence feature Temporarily silence unwanted nuisance alarms 7 An infrared remote IR feature to test and or silence the alarm with most household remote controls 8 Two Locking features tamper resistant locking pins that lock battery drawer and or alarm to mounting bracket 9 The unit shall be capable of operating between 10 F 23 C and 100 F 38 C and relative humidity between 10 and 90 10 The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment 11 The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms 12 of which can be smoke alarms 12 The unit shall at a minimum meet the requirements of UL539 CSFM NFPA 72 NFPA 101 ICC Installation of this heat alarm must conform to all local electrical codes and Article 760 of the National Electrical Code NFPA 70 8 and NFPA 72 Interconnected units must meet the following 678 requirements Total length of wire
4. interconnecting units should be less than 1000 feet be 18 gauge or larger and be rated at least 300V It is recommended that all units be on the same fuse or circuit breaker If local codes do not permit be sure the neutral wire is common to both phases THE PARTS OF THIS HEAT ALARM Mounting bracket Mounting Slots Locking Pins Hot Black AC Wire Nuetral White AC Wire Interconnect Orange Wire Battery Drawer Latch Battery Drawer Install oF Soo ew NS 9V battery here Quick Connect Plug o A Unswitched 120VAC 60 Hz source B To additional units Maximum 18 total Maximum 12 Smoke Alarms 5 Junction Box 6 Neutral Wire White 7 Interconnect Wire Orange 8 Hot Wire Black Smoke Alarm Ceiling or Wall Power Connector Wire Nut Alarm Dimensions 5 4 dia x 2 2 H Weight 7 3 0Z Operating Voltage 120V AC 60Hz w 9V battery backup Operating Current Temperature Range Humidity Range Audio Alarm Test Silence 05 amps standby alarm 10 F 23 C to 100 F 38 C 10 to 90 relative humidity RH 85dB at 10 feet Electronically simulates alarm condition causing the unit to alarm Press and hold test silence button Alarm Reset Automatic when temperature cools below 130 F Up to 18 units of First Alert or BRK Smoke CO and Heat Alarms Maximum of 12 smoke alarms See user s manual for details Interconnections Heat Sensor Thermistor Indicator Lights S
5. ounds AC Power Constant Green LED DC Power Intermittent Green LED Local Alarm Red LED flashes rapidly audio alarm Remote Alarm Red LED out Latching Alarm Red LED flashes after local alarm stops Listing Listed to UL539 Standard Individual Carton Dimensions 5 50 L x 2 50 W x 5 63 H Weight 0 50 Ibs Cube 0 045 ft3 UPC 0 29054 50810 2 Master Carton Dimensions 16 81 L x 10 31 W x 6 25 H Master Pack 12 Weight 6 3 Ibs Cube 0 63 ft3 20f5 100 29054 50810 9 Pallet Information Cases per Layer 10 Number of Layers T Cases per Pallet 70 Units per Pallet 840 Cube 54 7 ft3 Weight 550 Ibs 2009 BRK Brands Inc a Jarden Corporation Company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust ae is a registered trademark of BRK Brands Inc THE PROFESSIONAL STANDARD brkelectronics com
Download Pdf Manuals
Related Search
Related Contents
Freescale MQX Software Solution flexotron®800 flexotron®800: Electronic ventilation, air Délibération n° 335 du 11 août 1992 relative aux produits Laser Distance Meter SP LAM 301 Bilco SZ BGPC4 Instructions / Assembly Télécharger la fiche technique Manual de instrucciones XDS Loop System Users Manual Copyright © All rights reserved.