CGL Series 1500W DC-AC Inverter Operation Manual

image

Contents

1. NOVA ELECTRIC CGL SERIES PURE SINE WAVE DC AC INVERTERS CGL SERIES INVERTER Optional GFCI Outlet shown USER MANUAL NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 PHONE 201 385 0500 FAX 201 385 0702 EMAIL novasales theallpower com WEB ADDRESS www novaelectric com ee NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 FAX 201 385 0702 Page 1 URL www novaelectric com Features Pure Sine Wave output lt 3 THD Low power Power Saving Mode to conserve energy RS 232C interface remote control port Built in voltage and watt meter display on front panel Thermostatically controlled cooling fan Advanced microprocessor design Protection Input low voltage e Input overvoltage Low battery alarm e Short circuit Applications Electronic applications communications equipment commercial gear etc Office equipment computers printers monitors facsimile machines scanner Mobile equipment vans Kitchen appliances microwave ovens refrigerators and freezers coffeemakers blenders ice makers toasters Household items vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines Power tools circular saws drills grinders sanders buffers wedge and hedge trimmers air compressors Home entertainment
2. en NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 7 URL www novaelectric com FAX 201 385 0702 This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once 5 1 5 2 5 3 5 4 5 5 Controls and Indicators The front panel ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the power inverter When the switch is in the OFF position the power inverter draws no current from the battery When the switch is in the ON position but with no load the power inverter draws less than 1 65A normal 0 12A power saving mode 12V version from the battery Battery Voltage Indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter At low input current this voltage is very close to the battery voltage At high input current this voltage will be lower than the battery voltage because of the voltage drop across the cable and connections Ideally the voltage should remain in the green area of the bar graph If the voltage goes into the read area at the top and bottom of the graph the inverter may shut down Load Watt Indicator The AC load watt bar graph indicates the power drawn from the power inverter output It will indicate total watts drawn by all load
3. information to this unit Basically this unit is always ready for receiving data while operating When an LF character ASCII Code OAH is received this unit will finish the receiving by clearing the DTR status and begin to interpret the received information The unit will execute the received command and or data if it is correct No matter whether the command is accepted or not the unit will always send back the response signal to the computer and set the DTR ready for receiving incoming information The Baud rate of the RS 232 interface is determined by S5 and S6 of DIP SW as the following table shows e It is necessary to reset the unit after adjustment to activate the new Baud rate Illustration of the RS 232 operation 6 1 RS 232 Command Command Format This unit uses high level language commands with a CR ODh and an LF OAh as the end of the command The system will interpret and execute the command only after these two characters are received After the unit executes the command it will send a response string to the computer The response string is as follows gt CR LF Command executed successfully gt CR LF Command error not accepted gt CR LF Command correct but execution error e g parameters out of range If the command needs any information from the unit the unit will send the information back to the computer with CR and LF and then send the response string to the computer 6 2 Command Forma
4. Release the button when the LED indicates the desired status The operation POWER SAVING ENABLE DISABLE does not change the power ON OFF mode Despite the setting of the POWER SAVING mode when a POWER OFF command is set by pressing a button the power will be turned off and in the meantime the POWER SAVING mode will be set to DISABLE automatically the amber LED will flash for 2 3 seconds When the POWER is turned on the POWER SAVING mode will restore the previous setting ee NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 18 URL www novaelectric com FAX 201 385 0702
5. SOURCE WILL GO TO THE POSITIVE TERMINAL OF THE INVERTER 3 6 Set the power switch to the ON position Check the meters and indicators on the front panel of the inverter The voltage bar graph indicates 10 to 16 volts 20 to 32V when 24V version is used and 40 to 64V when the 48V version is used depending on the voltage of the power source If it does not check your power source and the connections to the inverter The other indicators should be off 3 7 Set the power inverter switch to the OFF position The indicator lights may blink and the internal alarm may sound momentarily This is normal Plug the test load into the AC receptacle on the front panel of the inverter Leave the test load switch off 3 8 Set power inverter switch to the ON position and turn the test load on The inverter should supply power to the load If you plan to measure the true output RMS voltage of inverter a meter such as FLUKE 87 BECKMAN 4410 or TRIPLETT 4200 must be used 4 Installation 4 1 4 2 Where to install The power inverter should be installed in a location that meets the following requirements 4 1 1 Dry Do not allow water to drip or splash on or in the inverter 4 1 2 Cool Ambient air temperature should be between 0 C and 50 C the cooler the better 4 1 3 Ventilated Allow at least one inch of clearance around the inverter for air flow Ensure that ventilation openings on the sides rear and bottom of the unit are
6. electronics television VCRs video games stereos musical instruments satellite equipment ee NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 2 URL www novaelectric com FAX 201 385 0702 Electrical Performance Specification Model No Model No Model No Model No Model No Model No Item CGL1 5K 12 120 CGL1 5K 24 120 CGL1 5K 48 120 CGL1 5K 12 220 CGL1 5K 24 220 CGL1 5K 48 220 Continuous Output Power 1500W 1500W 1500W 1500W 1500W 1500W Surge Rating 2000W 2000W 2000W 2000W 2000W 2000W Nominal Input Voltage 12V 24V 48V 12V 24V 48V Output Voltage Frequency 100 110 120 3 220 230 240 3 Switch Selectable 50 60Hz 0 05 50 60Hz 0 05 Peak Output Current 25A 11A Typical Efficiency 85 87 88 86 89 90 Full Load No Load Current lt 1 5W Saving Mode Output Waveform Sine Wave lt 3 THD Output Voltage Regulation 100 110 120V RMS 10 4 200 210 220V RMS 10 4 Input Voltage Regulation Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature GFCI Power Saving Recovery Time 5 Second Interface Control Port RS 232C with Baud Rate 1200 2400 4800 Switch Selectable Remote Control Unit Optional Operating Temperature 0 50 C Range Storage Temperat
7. good and that the battery is fully charged E NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 9 URL www novaelectric com FAX 201 385 0702 6 2 If the connections are good and the battery is charged but the voltage still drops below the low voltage level you may need to use a larger battery or larger wire Input Voltage The power inverter will operate from input voltages ranging from 10V 15V 12V version 20V 32V 24V version or 40 56V 48V version If the voltage drops below 10 5V 12V version 21V 24V version an audible low battery warning will sound and the voltage indicator will be in the lower red zone The power inverter will shut down if the input voltage drops below 10V 12V version 20V 24V version or 40V 48V version This protects your battery from being overdischarged The power inverter will also shut down if the input voltage exceeds its rating This protects the inverter against excessive input voltage The voltage indicator will be in the upper red zone Although the power inverter incorporates protection against overvoltage it may still be damaged if the input voltage is allowed to exceed 20V 12V version or 40V 24V version or 75V 48V version 7 Troubleshooting 7 1 Common Problems Television or other communication equipment interference Operation of the power i
8. warranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally and does not cover damage arising from improper use such as plugging the unit into an unsuitable power source attempting to operate products with excessive power consumption requirements or use in unsuitable climates Nova Electric assumes no liabilities for consequential damages of any kind through the use or misuse of its products by the purchaser or others No other obligations are expressed or implied ee NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 13 URL www novaelectric com FAX 201 385 0702 Appendix A Dip Switch 110V S1 S2 VOU S3 FREQ S4 POWER S5 S6 BAU T Hz SAVING D VAC RAT E ON ON 100 ON 50 ON DISABL ON ON 1200 E OF ON 110 OF 60 OF ENABL OF ON 2400 F F F E F ON OF 115 a ileg ON OF 4800 F F OF OF 120 ae ee Ta eee tae F F Dip Switch 220V S1 S2 VOU S3 FREQ S4 POWER S5 S6 BAU T Hz SAVING D VAC RAT E ON ON 200 ON 50 ON DISABL ON ON 1200 E en NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 05
9. 00 Page 14 URL www novaelectric com FAX 201 385 0702 OF ON 220 OF 60 OF ENABL OF ON 2400 F F F E F ON OF 230 ON OF 4800 F F OF OF 240 e F F Appendix B The Operation of RS 232 1 Hardware design This unit uses a 9 pin D connector and three of RS 232 signal RECEIVE DATA 9RXD PIN2 TRANSMIT DATA TXD PIN3 DATA TERMINAL READY DTR PIN4 The connection between this unit and a computer is as follows Computer RXD TXD DSR RTS CTS GND Power Inverter RXD TXD DTR GND The RS 232 interface of this unit employs ASCII Code to implement the asynchronous serial transmission control the byte structure is START BIT 8 BIT DATA STOP BIT Baud Rate 1200 2400 4800 SET BY DIP SW Parity Check NONE not settable Data Bit 8 not settable Stop Bit 1 not settable en NOVA ELECTRIC 10 2000 CGL INVERTER MANUAL Page 15 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 PHONE 201 385 0500 URL www novaelectric com FAX 201 385 0702 4 5 Not 6 Software Design The buffer size used for the RS 232 port is 12 bytes This unit will ignore all bytes above this value During this transmission this unit will inform the readiness of receiving to the computer by DTR line A computer has to check the units DTR line before sending any
10. FCI Tripped Push in the RESET botton on the GFCI Receptacle It it continues to trip remove The load see if it is at fault No output voltage Short circuit or Check AC wiring for short circuit or Over Load indicator ON wiring error Improper polarity hot and neutral reversed Very high power load Remove load es NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 12 URL www novaelectric com FAX 201 385 0702 8 Maintenance Very little maintenance is required to keep your inverter operating properly You should clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals 9 Warranty All Nova Electric products are warranted against defects in material and workmanship for a period of one year from shipping date Our obligation includes replacing repairing or adjusting products excluding fuses that prove to be defective during the warranty period The unit must be returned to us postage paid Contact our Customer Service Manager at 201 385 0500 Extension 116 or 121 for a Return Material Authorization RMA number This warranty is fully transferable If a product is sold to a manufacturer for use in a product for resale the complete warranty is in force providing the power system is sold as original equipment This
11. ar View Ventilation window Do not obstruct allow at least 1 inch for air flow DC input terminals Connect to a battery or other voltage power source of the correct voltage is positive is negative Reverse polarity connection will blow the internal fuse and may damage the inverter permanently The input wiring should be protected by an appropriately rated input fuse as per NEC or equivalent codes en NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 4 URL www novaelectric com FAX 201 385 0702 2 2 3 Chassis ground or to vehicle chassis using 8 AWG wire minimum Warning Operation of the inverter without a proper ground connection may result in an electrical safety hazard 3 Quick Hook up and Testing If you would like to quick hook up the power inverter and check its performance before going ahead with your installation please follow these guidelines 3 1 3 2 3 3 3 4 3 5 Unpack and inspect the power inverter check to see that the power switch is in the OFF position Connect the cables to the power input terminals on the rear panel of the power inverter The red terminal is positive and the black terminal is negative Connect the cables into the terminals and tighten the bolts to clamp the wires securely Connect the cable from the negative terminal of the inv
12. educe load Recharge battery check connections and cable Turn inverter on Check wiring to Inverter Have qualified Service technician check and replace Reverse DC polarity Have qualified service technician check And replace fuse OBSERVE CORRECT POLARITY No output voltage High input voltage Make sure that inverter is connected to a Voltage indicator In upper red zone Low battery alarm ON all the time Voltage indicator Below 10 5V 12V ver Poor DC wiring poor battery condition proper input voltage source Check regulation of charging system Use proper cable and make solid connection Use new battery 21V 24V ver or 42V 48V ver E NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 11 URL www novaelectric com FAX 201 385 0702 7 2 Troubleshooting Guide cont d Problem and Symptoms Possible Cause Solution No output voltage Thermal shutdown Allow inverter to cool off Reduce load if Over Temp indicator continuous operation required ON input DC current in excess of 1500W 150A 12V 75A 24V or 40A 48V No output voltage Thermal shutdown Improve ventilation Make sure ventilation Over Temp indicator openings in inverter are not obstructed ON load less than reduce ambient temperature 1500W 150A 12V or 75A 24V 1000W 75A 12V or 37 5A 24V No output voltage G
13. erter to the negative terminal of the power source Make a secure connection Caution Loosely tightened connectors result in excessive drop and may cause overheated wires and melted insulation as well as other damage Before proceeding further carefully check that cable you have just connected is from the negative terminal of the inverter to the negative output terminal of the power source Caution Reverse polarity connection will blow a fuse in the inverter and may permanently damage the inverter Damage caused by reverse polarity connection is not covered by our warranty Connect the cable from the positive terminal of the inverter to the positive terminal of the power source Make a secure connection Warning You may observe a small spark when you make this connection since current will flow to charge capacitors in the power inverter This can be avoided by installing a properly rated switch or circuit breaker at the power source Do not make this connection in the presence of flammable fumes an explosion or fire may result ee NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 5 URL www novaelectric com FAX 201 385 0702 NOTE WHEN CONNECTING TO A NEGATIVE DC VOLTAGE SOURCE AS COMMONLY DONE ON 48 VDC TELECOM APPLICATIONS THE NEGATIVE 48 VDC SOURCE GOES TO THE MINUS TERMINAL OF THE INVERTER THE RETURN OR ZERO
14. k the setting of DIP SW S5 S6 The communication BAUD RATE should be set to 4800bps S5 S6 OFF e LED Indications 1 Turn on the switch of the INVERTER there will be 2 short beep sounds from the INVERTER All LEDs will be on and one second later there will be a short beep sound The amber green and red LEDs of the Remote Controller will be one for 0 5 seconds then off sequentially The INVERTER is then in the OFF mode The amber LED will be blinking every 2 3 seconds 3 Remote Controllers LEDs Green POWER SAVING ENABLE Amber POWER SAVING DISABLE On POWER ON Blinking POWER OFF e Operations 1 Set SLIDE SW ON Keypads will not work if SLIDE SW is set OFFP es NOVA ELECTRIC A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET 10 2000 BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 17 URL www novaelectric com FAX 201 385 0702 Remote ON OFF press a button and release it in one second will change toggle the output ON OFF mode the display of LEDs will be changed correspondingly Operation of POWER SAVING mode Press the button for 2 seconds you will see the colors of the LEDs changing If you keep pressing the button the colors will be toggling between amber and green every 2 3 seconds The color of the LED will determine the mode of operation Green stands for the POWER SAVING mode ENABLE and amber stands for DISABLE
15. nd Therefore when the chassis is connected to ground the neutral conductor will also be grounded This conforms to national electrical code requirements that separately derived AC sources such as inverters and generators have their neutral tied to ground in the same way that the neutral conductor from the utility line is tied to ground at the AC breaker panel When the chassis ground lug on the rear panel is connected to an earth ground in the user s location it provides shock hazard protection The GFCI has a test button and a reset button Pushing in the test button will interrupt the output power Pushing in the reset button will restore the output power and the green light will be on Note Repeated pressing toggling of the GFCI test button may shut down the inverter AC output THIS IS NORMAL On units without GFCI the neutral is floating To conform to national electrical code requirements the neutral must be connected to ground or other neutrals that are grounded Warning Do not operate the power inverter without connecting the ground terminal to ground Electrical shock hazard may result and the GFCI circuit will not operate properly 5 Operation To operate the power inverter turn it on using the ON OFF switch on the front panel The pow load er inverter is now ready to deliver AC power to your loads If you are operating several s from the power inverter turn them on separately after the inverter has been turned on
16. not obstructed 4 1 4 Safe Do not install in a battery compartment or other areas where flammable fumes may exist such as fuel storage areas or engine compartments Cables DC to AC inverters require high amperage low voltage DC power to low amperage high voltage AC power To operate properly connect inverter DC input terminals directly to battery through a fuse or circuit breaker The different inverters in this family require different wire sizes due to the wide input voltage choices E NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 6 URL www novaelectric com FAX 201 385 0702 4 3 Grounding The power inverter has a lug on the rear panel chassis ground This is to connect the chassis of the power inverter to the ground The ground terminals in the AC outlets on the front panel of the inverter are also connected to the ground lug The chassis ground lug must be connected to a grounding point which will vary depending on where the power inverter is installed In a vehicle connect the chassis ground to the chassis of the vehicle In a boat connect to the boat s grounding systems In a fixed location connect the chassis ground lug to earth ground On units with Ground Fault Circuit Interrupt GFCI the neutral common conductor of the power inverter AC output circuit is connected to the chassis grou
17. nverter can interfere with television reception on some channels If this situation occurs the following steps may help to alleviate the problem e Make sure that the chassis ground lug on the back of the power inverter is solidly connected to the ground system of your vehicle boat shelter or home e Move the television as far away from the power inverter as possible e Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot This minimizes radiated interference from the cables Overheating Check for clean air intake and an exhaust opening and check that both fans are operating No Output Check the input fuses remove cover Check for correct input voltage ee NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 10 URL www novaelectric com FAX 201 385 0702 7 2 Troubleshooting Guide Problem and Symptoms Low output voltage 110V 95 105VAC 220V 190 210VAC Load LED bar Flash No output voltage And voltage indicator In lower red zone No output voltage No voltage indication Possible Cause Using average reading voltmeter Overload Low input voltage Inverter switched off No power to inverter Internal fuse open Solution Use true RMS reading meter See page 5 point 3 8 of manual R
18. s For long term operation the watt should be in the green and orange areas of the bar graph Short term operation is possible with watt in the red area If the watt rises to the Flash All bar the inverter will protect itself and may reduce its output voltage or shut down entirely Over Voltage Indicator The over voltage indicator indicates that the power inverter has shut itself down because its input voltage has been over the high limit Under voltage indicator en NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 8 URL www novaelectric com FAX 201 385 0702 5 6 5 7 The under voltage indicator indicates that the power inverter has shut itself down because its input voltage has been lower than the low limit Over Temp Indicators The over temp indicator indicates that the power inverter has shut itself down because it has become overheated The power inverter may overheat because it has been operated at power levels above its rating or because it has been installed in a loction which does not allow it to dissipate heat properly The power inverter will restart automatically once it has cooled off Over Temp indicator may also indicate a fan failure Overload Indicator The overload indicator indicates that the power inverter has shut itself down because its output circuit has been short circui
19. t This unit supports the following commands There should always be a CR ODh and an LF OAh appended to the command while sending the command to this unit 6 2 1 PWRS Command POWER SAVING FUNCTION CONTROL Format PWRS lt value gt Illustration A space ASCII Code 20h is needed between PWRS and lt value gt gt value gt can be one of the following 0 power saving disable en NOVA ELECTRIC 10 2000 A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 CGL INVERTER MANUAL PHONE 201 385 0500 Page 16 URL www novaelectric com FAX 201 385 0702 1 power saving enable 2 inquire as to the status of power saving function control the response information will be either 0 disable or 1 enable 6 2 2 POWER Command POWER ON OFF Control Format POWER lt value gt Illustration A space ASCII Code 20h is needed between PWRS and lt value gt gt value gt can be one of the following 0 power off power consumption lt 2W restart time lt 5 sec 1 power off power consumption lt 20W restart time lt 2 sec 2 power on 3 inquire as to the status of power on off status the response information will be either 0 off or 1 off or 2 on Appendix C Remote Control Operations Manual e System Configuration 1 Plug the 9 pin D SUB connector of the Remote Controller in the RS 232 of the Inverter 2 Chec
20. ted or drastically overloaded Switch the front panel ON OFF switch to OFF correct the fault condition and then switch the ON OFF switch back to ON 6 Operating Limits 6 1 Power Output The 1500W inverter will operate most AC loads within its power rating When determining whether a microwave oven can be operated by the 1500W inverter remember that the power commonly advertised for microwave ovens is the cooking power the power delivered to the food not the power actually consumed by the microwave oven The microwave oven will consume 40 to 100 more than its advertised cooking power Check the rating sticker on the back of the oven to determine its actual power draw The 1500W inverter will operate small microwave ovens 0 2 to 0 3 cubic foot capacity that draw about 1700 watts It will provide 3 minutes of cooking time Some induction motors used in refrigerators freezers pumps and other motor operated equipment require very high surge currents to start often as much as 6 7 times rated The power inverter may not be able to start some of these motors even though their rated current draw is within the power inverter If the motor refuses to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below the low input level while the inverter is attempting to start the motor this may be the reason the motor won t start Make sure that the battery connections are
21. ure Range 30 C to 70 C Dimensions 15 3 x 10 8 x 4 13 inch 390 x 275 x 105mm Weight 15 5 Ibs 7 kgs ee NOVA ELECTRIC 10 2000 CGL INVERTER MANUAL Page 3 URL www novaelectric com A DIVISION OF TECHNOLOGY DYNAMICS INC 100 SCHOOL STREET BERGENFIELD NJ 07621 2915 PHONE 201 385 0500 FAX 201 385 0702 2 1 1 2 1 2 2 2 1 2 2 2 Introduction This power inverter series are part of the most advanced line of mobile AC power systems available This model is used in a wide range of applications including mobile equipment shelters remote homes RVs sailboats and powerboats It will operate most televisions and VCRs personal computers small appliances and tools such as drills sanders grinders mixers and blenders within the power ratings shown in the table on the prior page To get the most out of the power inverter it must be installed and used properly Please read the instructions in this manual before installing and using this model Name and Main Function Front View ON OFF Switch Power ON OFF switch Leave in the OFF position during installation OVP Over voltage protection UVP Under voltage protection OTP Over temperature protection OLP Over load protection INPUT VOLTS display input voltage LOAD WATTS display AC load watts AC Outlet Outlet sockets available Australia New Zealand North America US Europe UK Ireland GFCI US Type Re