Home
Datasheet - MetricTest
Contents
1. approximately 1 7 dB of range for 98 peak noise Bellcore TR TSY 000196 Issue 2 Using Bellcore TR TSY 000196 Issue typical Deadzones measured on 45 dB reflections typical 4 Wavelength dependent OTDR Module Ordering Information Part Number TD 14MXX XX X VFL Module Available Enter last two digits of module number Select Power Meter for OTDR modules 4415 4425 4436 4439 4442 and 4456 0 No power meter 1 10 dBm Power Meter 2 20 dBm Power Meter Select Power Meter for OTDR modules 4453 4454 4473 and 4476 0 No Power Meter 3 10 dBm InGaAs Power Meter 4 20 dBm InGaAs Power Meter Note No Power Meter Options for module 4498 Select Light Source Option 0 No Light Source 1 Dual wavelength with only dual optical module 2 Single wavelength with only single optical module Note no light source option for 4498 or multimode wavelength modules Select Connector polish for Modules 2 Ultra PC Single mode 3 Angled PC Single mode 4 62 5 um PC Multimode 444X modules only 6 62 5 um PC MM Ultra PC SM 4456 and 4457 modules only 7 62 5 um PC MM Angled PC SM 4456 and 4457 modules only VFL XX FC SC ST fixed connectors Optical Spectrum Analyzer OSA Specifications Module 4791 NI 4792 Wavelength range Wavelength accuracy Resolution bandwidth Power Range Polarization dependence Channel table Return Loss Cyclic Time Stabil
2. nm 20 nm 1550 nm 20 nm 1550 nm 20 nm 1550 nm 20 nm 1300 nm 20 nm 1550 nm 20 nm 1410 nm 10 nm 1300 nm 20 nm 1300 nm 20 nm 1625 nm 10 nm 1625 nm 10 nm 1625 nm 10 nm 1550 nm 20 nm 1310 nm 20 nm 1310 nm 20 nm 1625 nm 10 nm 1550 nm 20 nm 1550 nm 20 nm Fiber Type Single mode Single mode Single mode Single mode Multimode Single mode Single mode Multimode and Multimode and Single mode Single mode Single mode Single mode Single mode 1550 nm lt 15 nm 1550 nm 50 dB 1550 nm 4 5 meters 1550 nm 12 meters Deadzone 1550 nm 12 meters 1550 nm 12 meters 1550 nm 6 meters 1550 nm 10 meters 1300 nm 7 meters 1550 nm 7 0 meters 1410 nm 7 0 meters 1300 nm 7 meters 1300 nm 9 meters 1625 nm 7 meters 1625 nm 7 meters 1625 nm 7 0 meters 1550 nm 7 0 meters 1310 nm 10 meters 1310 nm 11 meters 1625 nm 7 0 meters 1550 nm 12 meters 1550 nm 12 meters Linearity 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB 04 dB dB Pulsewidth 10 ns to 20 us 10 ns to 20 us 10 ns to 20 us 10 ns to 30 us 4ns to 1 us 10 ns to 20 us 10 ns to 20 us 4ns to 10 us 4 ns to 20 us 10 ns to 20 us 10 ns to 20 us 10 ns to 30 us Distance Resolution 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 0001 km 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 meters 0 1 me
3. troubleshoot and optimize performance in today s complex hybrid networks and in those planned for tomorrow So NetTest undertakes a continuous and intensive product development program to ensure that its instruments and systems perform to the highest technical standards As a result the specifications in this document N E I l E S I are subject to change without notice ISO 9001 certified RevA 10 01 formerly GN Nettest
4. SPECIFICATION SHEET CMA4000 OPTICAL TEST SYSTEM Mainframe Specifications Display Floppy Drive Keyboard I O Ports Hard Drive Dimensions H x W x D Weight Power Power Supply Battery Battery Life Recharge Time Environmental Operation Temperature Humidity Maximum Altitude Storage Temperature Humidity Maximum Altitude Ordering Information CMA4000i Includes VGA LCD Display 21 3 cm 8 4 inch color or 20 8 cm 8 2 inch monochrome 3 5 inch Intergral alpha numeric external keyboard optional Standard 2 RS 232 Serial 1 Parallel VGA Mouse and 1 PS 2 External Keyboard Port 2 Gigabytes minimum 24 1 x 34 3 x 9 5 cm 9 5 x 13 5 x 3 75 inches 4 9 kg 11 0 Ibs Includes mainframe battery and module Autoswitching 100 132 VAC 47 63 Hz 184 250 VAC 47 63 Hz 10 15 VDC 2 Sealed lead acid battery pack 6 hours typical depending on operating mode 1 5 2 hours AC Power Battery 0 C to 45 C 32 F to 122 F 0 C to 40 C 32 F to 104 F 95 RH max non condensing 95 RH max non condensing 15 240 meters 50 000 feet 15 240 meters 50 000 feet 25 C to 60 C 13 F to 140 F 95 RH max non condensing 15 240 meters 50 000 feet Floppy drive operator s manual Understanding OTDR training manual AC charger adapter two batteries carry strap protective display cover serial data transfer kit and choice of AC power cord select one from below Mainfr
5. ame Selection required TD 14XXE Select Hard Drive Option 1 No Hard Drive OTDR Only 3 Hard Drive Option 4 Hard Drive amp DOS 6 22 Option 5 Hard Drive amp Windows 95 Option Select Display Option 1 Monochrome Display 2 Color Display Available for use with OTDR modules Color display required for use with OSA modules AC Power Cord Options TD 11685 US Japan AC power cord TD 30358 European AC power cord TD 30359 UK AC power cord TD 30360 Swiss AC power cord TD 30362 Australian AC power cord TD 30361 Italian AC power cord a NETTEST formerly GN Nettest OTDR Specifications Spectral Width RMS Dynamic Range Initial Reflective Deadzone Initial Non Reflective 1310 nm lt 10 nm 1550 nm lt 10 nm 1310 nm 30 dB 1550 nm 28 dB 1310 nm 3 meters 1550 nm 3 meters 1310 nm 10 meters 1310 nm lt 10 nm 1550 nm lt 10 nm 1310 nm 36 dB 1550 nm 34 dB 1310 nm 3 meters 1550 nm 3 meters 1310 nm 10 meters 1310 nm lt 10 nm 1550 nm lt 10 nm 1310 nm 40 dB 1550 nm 40 dB 1310 nm 3 5 meters 1550 nm 3 5 meters 1310 nm 6 meters 1310 nm lt 10 nm 1550 nm lt 15 nm 1310 nm 43 dB 1550 nm 46 dB 1310 nm 3 meters 1550 nm 3 5 meters 1310 nm 10 meters 850 nm lt 10 nm 1300 nm lt 10 nm 850 nm 23 dB 1300 nm 26 dB 850 nm 3 5 meters 1300 nm 3 meters 850 nm 6 5 meters 1310 nm lt 12
6. gs Horizontal Scale Settings Stored Data Points Language Capability Mass Storage Meets CDRH Class 1 Requirements Eye Safe 21 CFR 0 0025 of distance measurement distance resolution index uncertainty 1 400000 1 699999 ORL 2 point 2 point LSA dB KM dB KM LSA splice dual splice loss reflectance 4 Trace Overlay Delta Trace Compare Align Stack Real Time Fast Scan Medium Scan Slow Scan Timed Average user selectable Trace display event table integrated trace display with event information window header page measurement parameters ASCII report overlay template Automated high speed fiber analysis 0 125 0 25 0 5 1 2 4 8 dB module dependent 0 001 km div to 0 448 km div 2 km 0 001 km div to 57 304 km div 256 km IOR 1 5 16 000 Dial a language English Chinese Spanish Portuguese French Russian German Italian Swedish Korean Hungarian Over 65 000 traces with hard drive Up to 180 traces for a standard 8 89 cm 3 5 inch 1 44 MB floppy disk Up to 125 traces internal storage Adapters for Ultra Polish UC 130 15 DIN 47256 UC 130 40 Diamond HP HMS 10 UC 130 20 D4 UC 130 45 Diamond HMS 0 UC 130 25T FC UC 130 50 Diamond HMS 10 A UC 130 30T ST UC 130 55A SC UC 130 35 SMA 905 906 Adapters for Angle Polish UC 130 60 FC NTT UC 130 70 DIN HRL 10 UC 130 60A FC Seiko Giken UC 130 75 ST UC 130 65 SC UC 130 80 Diamond E 2000 1 SNR 1 with up to 256k averages Typical subtract
7. iberConnect 1 UST we 3mm Test Fiber Boxes XXX XXX Connector Style FB XXX XXX SM 300M FB XXX XXX M5 100M FB XXX XXX SM 1KOM FB XXX XXX M6 100M FB XXX XXX SM 5KOM Standard fiber lengths Single mode SM 300m 1Km and 5Km Multimode MM 100m Standard Connectors SM and MM UFC UFC UST UST USC USC Additional connector styles combinations and lengths for the Fiber Test Boxes are available upon request FS Series Microscopes FS 200 Fiber Microscope with 200x optics FS 200C Fiber Microscope with 200x optics with coaxial illumination FS 400C Fiber Microscope with 400x optics with coaxial illumination i NetTest Optical Division 6 Rhoads Drive Utica New York USA Tel 1 315 266 5000 FAX 1 315 798 4038 E Mail marketing ont nettest com Web www nettest com NetTest Companies e Australia 61 39 890 6677 Brazil 55 11 5505 6688 Canada 1 905 479 8090 China 86 10 64 67 98 88 France 33 1 30 08 88 88 Germany 49 89 99 89 010 Italy 39 02 95 12 621 Mexico 52 5557 8248 e Nordic 45 72 11 23 00 Singapore 65 220 9575 Spain 34 91 372 92 27 Sweden 46 8 555 410 65 UK 44 1883 349110 USA 1 978 983 3800 NetTest develops manufactures and markets advanced equipment and systems for the test and measurement of telecommunication data communication and optical networks We provide vendors carriers enterprises a and research laboratories with the network testing solutions they need to
8. ity Power accuracy 1520 1570 nm 20 pm typical lt 0 05 nm 10 to 70 dBm per channel 20 to 60 dBm per channel lt 0 25 dB Automatically generated up to 400 channels lt 35 dB 4 seconds maximum 0 2 dB per hour 0 5 dB 23 C 1520 1620 nm 20 pm typical lt 0 05 nm 10 to 70 dBm per channel lt 0 25 dB Automatically generated up to 400 channels lt 35 dB 4 seconds maximum 0 2 dB per hour 0 5 dB 23 C Modes of Operation Acquisitions Language Capability Graph Table and Drift Modes Real Time Average Peak Hold and Channel Drift Model 4791 only Multi Test Functions Wavelengths Output Transmission Mode Output Fiber Optical Connector Stability Spectral Width Safety Single mode Light Source factory installed Same as OTDR 8 dBm minimum CW 2 KHz 9 125 um SM fiber Same as OTDR 0 2 dB 8 hours Same as OTDR Same as OTDR Power Meter factory installed Detector Type Range Calibrated Wavelengths Universal Connector Resolution Store Reference Mode Accuracy Linearity 2 mm Ge PIN photodiode or InGaAs photodiode 10 to 55 dBm or 20 to 45 dBm with AM460 filter 850 1310 1410 1550 1625 nm Yes use AM 430 xx adapter caps 0 01 dB 0 01 Watts Yes 4 0 18 dB 5 dBm to 50 dBm 8 0 36 dB 10 dBm to 5 dBm and 50 dBm to 55 dBm 0 04 dB 5 dBm to 50 dB
9. m Visual Fault Locator field installed Wavelength Output Transmission Mode 650 10 nm 0 dBm CW or 2 Hz Output Fiber 9 125 um SM fiber Safety IEC 825 Class 2 FDA 21 CFR 1040 10 Class 2 Notes 1 Specification applies to 10 dBm meter Available with 1410 nm light source only Available with 1625 nm light source only Power Meter Connector Options select one when ordering power meter AM 430 15 D4 AM 430 75 VFO PFO AM 430 20 SMA 906 AM 430 85 DIN AM 430 25 Diamond GFS 3 AM 430 90A SC AM 430 45 FC AM 430 95 E2000 AM 430 50 ST AM 430 100 FDDI VFL Connector Options FC SC ST fixed connector Optional Accessories must be added as separate line item TD 400A Hard case w handle amp wheels TD 430 CMA serial transfer data kit TD 401 Hard transit case TD 435 Display cover TD 410 Deluxe soft case TD 30163 OTDR User s Manual TD 415 Soft carry bag TD 35992 OSA User s Manual TD 405 Printer w cable TD 459US US style keyboard TD 420 Tripod TD 459GE German CE style keyboard TD 309 Printer paper 5 rolls TD 459FR_ French CE style keyboard TD 409 Case of paper 25 rolls TD 459SP_ Spanish CE style keyboard TD 453 12V lead acid battery TD 459IT Italian CE style keyboard TD 29621 12V DC power adapter FiberConnect Bare Fiber Testing Adapters Single mode j Ultra Angled P FiberConnect 1 UFC FiberConnect 1 AFC F Fi FiberConnect 1 USC FiberConnect 1 ASC p r F
10. nm 1550 nm lt 12 nm 1625 nm lt 12 nm 1310 nm 40 dB 1550 nm 40 dB 1625 nm 40 dB 1310 nm 3 5 meters 1550 nm 3 5 meters 1625 nm 3 5 meters 1310 nm 7 0 meters 1310 nm lt 12 nm 1410 nm lt 12 nm 1550 nm lt 12 nm 1625 nm lt 12 nm 1310 nm 36 dB 1410 nm 36 dB 1550 nm 36 dB 1625 nm 36 dB 1310 nm 3 5 meters 1410 nm 3 5 meters 1550 nm 3 5 meters 1625 nm 3 5 meters 1310 nm 7 0 meters 850 nm lt 10 nm 1300 nm lt 10 nm 1310 nm lt 10 nm 1550 nm lt 10 nm 850 nm 23 dB 1300 nm 25 dB 1310 nm 22 dB 1550 nm 21 dB 850 nm 3 5 meters 1300 nm 3 0 meters 1310 nm 3 meters 1550 nm 3 meters 850 nm 6 5 meters 850 nm lt 10 nm 1300 nm lt 10 nm 1310 nm lt 10 nm 1550 nm lt 10 nm 850 nm 22 dB 1300 nm 24 dB 1310 nm 33 dB 1550 nm 31 dB 850 nm 4 5 meters 1300 nm 4 5 meters 1310 nm 4 0 meters 1550 nm 3 5 meters 850 nm 8 meters 1550 nm lt 10 nm 1625 nm lt 10 nm 1550 nm 34 dB 1625 nm 36 dB 1550 nm 4 meters 1625 nm 4 meters 1550 nm 11 meters 1550 nm lt 10 nm 1625 nm lt 10 nm 1550 nm 40 dB 1625 nm 40 dB 1550 nm 4 meters 1625 nm 4 meters 1550 nm 11 meters Module 4415 4425 4436 4439 4442 4453 4454 4456 4457 4473 4476 4498 Center Wavelength 1310 nm 20 nm 1310 nm 20 nm 1310 nm 20 nm 1310 nm 20 nm 850 nm 20 nm 1310 nm 20 nm 1310 nm 20 nm 850 nm 20 nm 850 nm 20 nm 1550 nm 20 nm 1550 nm 20 nm 1550 nm 20 nm 1550
11. ters 0 1 meters 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 0 001 kft 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi 1 ft 0 0001 mi Distance Sampling 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 0 25 0 5 1 range dependent 2 4 8 16 meters 2 4 8 16 meters 2 4 8 16 meters 2 4 8 16 meters 2 4 8 meters 2 4 8 16 meters 2 4 8 16 meters 2 4 8 16 meters 4 2 4 8 16 meters 2 4 8 16 meters 2 4 8 16 meters 2 4 8 16 meters Distance Range 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 64 km 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 2 4 8 16 32 Setting 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km 64 128 256 km Loss Resolution 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB 0 001 dB Additional OTDR Specifications OTDR Source Connector Adapter Options Notes Laser Safety Distance Accuracy Group Refractive Index Setting Loss Modes Trace Compare Modes Data Acquisition Information Output Analysis Vertical Scale Settin
Download Pdf Manuals
Related Search
Related Contents
Beewi BBZ351 Bedienungsanleitung Peach 312260 ink cartridge Catalogue de coffres Copyright © All rights reserved.
Failed to retrieve file