Home
User manual
Contents
1. minutes and try again Is Is the lamp blown 0 Is the lamp blown 0 blown Replace lamp with new one Is the light generator too hot Check with installation while operating instructions Reinsert the power cord Light switches ON and OFF is the fan blocked Clear the airways Secure airflow is not blocked Is Is the fan broken fan broken ls the fan broken Replace the fan with a new one Replace the fan with a new one fan with a new one Is the lamp old Replace the lamp with a new one Clean the filters with a damp The light output has Are the filters dirty cloth Finish by wiping off with a aie dry lint free cloth diminished Clean the harness common end Is the fibre harness common end with a damp cloth Finish by wiping off with a dry lint free cloth 8 Spare parts and Accessories Roblon item no Model designation 65124200 13861 from Philips 12V Halogen 640601 22 KDE1206PTV2 from Sunon Trafo 68002121 230V 12V 60W electronic 68001212 120V 12V 60W electronic 78000270 Yellow colour filter with bracket Colour filter 78000271 Green colour filter with bracket 78000272 Blue colour filter with bracket 78000273 Red colour filter with bracket Roblon accepts no responsibility for possible errors in printed and electronic material Roblon reserves the right to alter or discontinue products without notice 2012 Roblon A S Roblon Roblon Lighting Tel 45 9620 3300 Nordh
2. Glass Supply voltage 230 V 50 60 Hz Lamps 42W Philips type 13861 12V Halogen Power consumption 42 W Fuse Integrated auto Power cord Cord w o earth connection Dimming Mechanical dimming on 01200131 and 01200153 Ballast Electronic Thermal protection Integrated in transformer Cooling system 12 VDC axial fan 60x25mm Fan noise level 26 db A Ambient temperature 15 40 C Lamp type Halogen Lamp life time 6000 hours Lamp colour temp 2900K Material Steel Powder coated Dimensions L x H x W 162 x 98 x 77mm Weight 900 g Safety approvals CE D cULus F E 4 Installing the light generator 1 Insert the harness common end fully into the light port on the light generator 2 Tighten the finger screw at the light port 3 Check that the requirements of installation and ventilation are met 4 Connect the supply cord to the main power supply Fibre types FL 2001 can be used with both plastic PMMA and glass fibre If PMMA fibre is used there should be mounted a heat filter in front of the lamp 5 Fixating the light generator to a surface 1 Loosen the screw at the top of the light generator to open the cover 2 Be careful not to damage the lamp Remove it if necessary 3 Mount the light generator with one or two screws not included through the holes on each side of the lamp 4 Reinstall the lamp and close the cover again l E gt a i a 4 7 A N m sL 6 Mountin
3. FL 2001 1 Halogen light generator for Fibre Optic Lighting systems User Manual 0120012 g9 mode g 37293 gli oot use Mu pat 20 Hz mp ip Rating hovi a voltage 45 VA 1386 powe philip g oP on co rated aut www robe These mounting instructions describes mounting and installation of the following products Item no o O N NO o oo o gt op Q o o oo o os os 0120 0121 0120 0131 0120 0151 0120 0153 FL 2001 1 FL 2001 1D FL 2001 1 FL2001 1D OI 230V 9 230V Mechanical dimmer OI 120V 9 120V Mechanical dimmer toblon 1 Introduction This manual serves you as a guideline to how the system is operated in the safest way Following the recommendations in this guideline all contributes to e Enhanced functionality e Extended lifetime of components e Uninterrupted illumination Your Roblon halogen light generator type FL 2001 is intended for indoor use in fibre optic lighting systems using either glass or PMMA fibres This light generator is prepared for use in cabinets or showcases either closed or semi closed compartments Contents 1s INTRODUCTION een Beeren tems 2 PRODUCT OVERVIEW AND PACKING LIST un 35 TECHNICAE INFO ne oO N O A O C UY m m UN aL O O Z a 2 Product overview and packing list Contents of the box FL 2001 1 User manual 3 Technical info Light port size 089 mm Fibre type PMMA
4. avnsvej 1 Fax 45 9620 3399 9900 Frederikshavn info roblon com Denmark www roblon com
5. g of optional colour filters not included 1 Loosen the screw 2 Open the cover 3 Mount the filter bracket making sure that it is fitted back to back with the already installed heat filter bracket Two self tapping screws are supplied in the colour filter kit A screwdriver Torx 10 is needed 4 Close the cover again and secure the screw Maintenance The outside of the cabinet may be cleaned with a damp cloth lf the environment is very dusty it is recommended that the interior be inspected and cleaned every 3 month or with suitable intervals If it is necessary to clean the lamp and reflector do so using a lint free cloth Do not touch the cleaned surfaces with the fingers as this will reduce the performance on lamp life The best results may be ensured by fitting a new lamp under such conditions 111 Never apply detergents containing alcohol to PMMA fibres Changing a lamp Switch of disconnect unit from power Open the top cover Lift the lamp out of the lamp holder Disconnect the lamp Fit a new lamp type Philips no 13861 Take care not to touch the lamp or reflecting surfaces with bare fingers Should this accidentally happen remove the lamp amp clean as previously described 6 Close the cover OTK WN 7 Trouble shooting Is the power ON Turn ON the power Is the power cord No light Check with the installation Is the light generator too hot instructions Cool off for 10
Download Pdf Manuals
Related Search
Related Contents
Directed Electronics AVITAL 4603 User's Manual Politique de protection de la vie privée User manual pompe à palettes RE 6, RZ 6 et groupe de pompage User Manual WDecD-TN DCC Accessory Decoder - Bahn-in Copyright © All rights reserved.
Failed to retrieve file