1. P 18 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e Again use the mouse to move to the next column Enter a GROUP NAME if desired for the data set by typing the group name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use commas or semicolons in the Group Name CURRENTLY EDITING Di File Settings Points Row RegisterEntry Register Bank REG ADDRESS GROUP NAME POINT HAME TRANSMITTER ID TRANS CHAN 0 Garage e Enter a POINT NAME if desired for the data point by typing the name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use commas or semicolons in the Point Name File Settings Points Row RegisterEntry Register Bank REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN 0 Garage Exhaust Far e Assign a sensor transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu This is the device ID of the remote output devices RD2402 amp RD2432 Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell To select the address click on the appropriate ID in the drop down menu P 19 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton
2. REG 4D0DRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN Again use the mouse to move to the next column Enter a GROUP NAME if desired for the data set by typing the group name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use commas or semicolons in the Group Name Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software File Settings Points Row RegisterEntry Register Bank Sethe GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN 0 Office West e Enter a POINT NAME if desired for the data point by typing the name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use commas or semicolons in the Point Name File Settings Points Row RegisterEntry Register Bank REG ADDRESS GROUP HAME POINT HAME TRANSMITTER ID TRANS CHAN 0 Office West SunShadel e Assign a sensor transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu This is the device ID of the remote output devices RD2432 Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell To select the address click on the appropriate ID in the drop down menu REG ADDRESS GAOUP NAME POINT HAME O Office Wrest Sunshade e Assign the appropriate digi
3. P 36 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 37 of 42 ACI MOD9200 MODBUS Gateway Programming Software Input Output Configuration Map Analog and Digital Inputs Programmer Software Input Register 00 to 99 to MODBUS Input Register 30001 to 30100 Digital Relay Outputs Programmer Software Digital Output Coil Register OO to 49 to MODBUS Coil Register 01 to 50 Analog Outputs Programmer Software Analog Output Holding Register 00 to 49 to MODBUS Holding Register 40001 to 40050 The Input Registers The MODBUS Input Register 30001 to 30100 are used to receiver all sensor inputs All wireless sensor information analog and discrete input will be displayed as numeric values All digital status alarms will be received and stored by MOD9200 as 1 or 0 1 input contact closed amp O input contact open The Digital Capture Time can be set to hold momentary contact closures long enough to be picked up by the system The Digital Capture Time can be set up to 240 minutes 4 hours in applications where an extended period of time is needed such as unoccupied period by pass All analog data will be received and stored as integer values For data types THERM 20k RTD 1k RTD 1k Ext and HUMIDITY the least significant digit of the integer value is the decimal number 1 e 8000 will mean 800 0 For the data type ANALOG there is no deci
4. Data Bits Parity Even Stop Bits i ar 5 ance e Select the appropriate Modbus Transport Mode RTU or ASCII and click OK to save the serial communication parameters to the Configuration File P 29 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software The transport mode selected needs to be the same as in the Master configuration e To Save the configuration file click on File gt Save It is recommended that the configuration ini file be saved in the trs config folder already setup 1 e C trs config Save Register Configuration My Recent Documents My Documents pE My Computer T amp File name Sunset Lane ini e l My Network Save as type cotrs config y ini Places P 30 of 42 Automation Components Inc 2305 Pleasant View Rd Middleton WI 53562 MOD Rev 8 0 2011 ACI MOD9200 MODBUS Gateway Programming Software l Sending The Configuration File To The MOD9200 Note Even if you are planning to use the RS485 RTU ASCIT MODBUS protocol option a network connection or crossover cable is required during the initial setup of the gateway for transporting the Gateway Configuration File via FTP e Always Save the configuration file to the folder trs config before sending it to the MOD9200 Gateway e To send the new configuration file to th
5. 8 Lost Communication Alarm Bit 4 set The Analog Output Holding Register alarms 0 Normal 32 Lost Communication Alarm Bit 6 set Alarm Status Examples Example 1 Input Register 30108 returns a value of 33 representing Input Register 30008 Low Battery Alarm Coil Register 08 Normal amp Holding Register 40008 Lost Communication Example 2 Input Register 30108 returns a value of 40 representing Input Register 30008 Normal Coil Register 08 Lost Communication amp Holding Register 40008 Lost Communication Example 3 Input Register 30128 returns a value of 42 representing Input Register 30028 Lost Communication Coil Register 28 Lost Communication amp Holding Register 40028 Lost Communication Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software Example 4 Input Register 30128 returns a value of 9 representing Input Register 30028 Low Battery Alarm Coil Register 28 Lost Communication amp Holding Register 40028 Normal d BTM9010 SensorView Monitoring amp Logging Application P 40 of 42 The SensorVull Monitoring and Logging software interfaces directly to the MOD9200D Gateway over an Ethernet network The combination results in a real time monitoring and logging system BTM9010 designed to work with a Windows based PC with an Ethernet LAN port The logged file is c
6. WI 53562 ACI MOD9200 MODBUS Gateway Programming Software REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN 3458 0 Garage Exhaust Fan e Assign the appropriate digital or relay output TRANS CHAN to the data register by clicking in the cell to open a drop down menu Click on the appropriate transmission channel 01 to 04 to select oe a Se Se i REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN 0 Garage Exhaust Fan 3456 a 1 2 3 4 e The active transmission channels or output number are factory set as follows eer Tetieewat NAY wey and relay 2 output module to relay 4 output to 4 analog output module g Analog Output Holding Register Configuration e Select the Analog Output Holding Register table by clicking the RegisterBank tab REG ADDRESS GROUP NAME Input Registers 0 Garage Digital Qutput Coil Registers Analog Output Holding Registers P 20 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 21 of 42 ACI MOD9200 MODBUS Gateway Programming Software First we will assign the REG ADDRESS by clicking in the cell Before entering register addresses ensure the RegisterEntry AutoSet is turned off as shown Tum AutoSet ON TRANSMITTERID TRANS CHAN Turn AutoSet OFF Enter the Register address in the REG ADDRESS window The valid range is 0 to 49 Eii SS File Settings n B
7. amp B to the MODBUS master When running the RS485 loop into a breaker panel use wire with appropriate insulation for the voltage present See Figure 1 P 6 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software Multiple RS485 Devices If more than one RS485 device is used the devices should be daisy chained or straight line connected by connecting all the A wires to the A terminals and the B wires to the B terminals Do not use spur lines or a star configuration RS485 Terminating Resistor If the MOD9200 is at the end of a RS485 loop a terminating resistor should be installed to match the electrical impedance characteristic of the twisted pair loop and prevent signal echoes from corrupting the data b Network Setup Note Even if you are planning to use the RS485 RTU ASCIIT MODBUS protocol option a network connection or crossover cable is required during the initial setup of the gateway for transporting the Gateway Configuration File via FTP Connect the MOD9200 Gateway to a 10 100Base T Ethernet network or use a crossover cable to connect directly to the PC Note Only 1 TCP IP connection is allowed at a time either a MODBUS Polling Master or the Programmer Configuration Tool DO NOT try to use both at the same time Apply 24 VAC 60 Hz power to the MOD9200 Gateway c Setting A New IP Ad
8. gt Browse and select the CD ROM Drive with the ConfigTool disk Double click on setup exe Follow the on screen instructions to complete the installation 2 To open the program click on Start gt Programs gt ConfigTool To create a new configuration file see the instructions To send an existing configuration file to the MOD9200 Gateway see the instructions on previous pages 3 After sending a configuration file the Gateway will automatically reset itself and initialize the new configuration file 4 If the Gateway is configured to use the MODBUS Serial transport protocols RTU or ASCII the Gateway needs to be connected to the appropriate serial communication connections Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software For more information please contact ACI2305 Pleasant View Rd Middleton WI 53562 Telephone 1 608 831 2585 www workaci com P 42 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562
9. Bank REG ADDRESS GROUP NAME TRANSMITTER ID TRANS CHAN DATA FORMAT D First Floor YP Office 1 THERM 20k 1 First Floor YP Office 2 HUMIDITY 2 First Floor general Office 1 THERM 20k 3 Warehouse North 1 THERM 20k 4 Warehouse West 1 THERM 20k ANALOG_INPUTS 5 Warehouse East 1 THERM 20k The columns may be resized by placing the cursor over one side of the column When the cursor changes to two arrows hold down the left mouse button and drag the side of the column to resize it Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software f Digital Output Coil Register Configuration e Select the Digital Output Coil Register table by clicking the RegisterBank tab File Arnie Points Row RegisterEntry Register Bank REG FUNCTION REG ADDRESS Input Registers SMITTERID TRANS C Digital Output Coil Registers Analog Qutput Holding Registers e First we will assign the REG ADDRESS by clicking in the cell Before entering register addresses ensure the RegisterEntry AutoSet is turned off as shown Fiese a regist REG ADDRESS GROU Turn AutoSet ON TRANSMITTER ID TRANS CHAN Turn AuteSet OFF e Enter the Register address in the REG ADDRESS window The valid range is 0 to 49 File Settings Points Row RegisterEntry Register Bank r REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN o
10. screen instructions to complete the installation e Ifthe Programmer setup program does not start automatically click on Start gt Run gt Browse and click on the Programmer CD ROM Double P 11 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software click on setup exe Follow the on screen instructions to complete the installation d Creating A MODBUS Configuration File e Tocreate anew MOD9200 configuration file open the Programmer by clicking on Start gt Programs gt Trs Programmer 6 XX File Settings Points Row RegisterEntry Register Bank e To open a new configuration table Click on File gt New Gateway File A blank configuration table will open File Settings Points Row RegisterEntry Register Bank REG FUNCTION REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT e The default startup is the Input Register configuration table and System Setup page e By clicking the RegisterBank tab you can go to the Digital Output Coil register configuration table or Analog Output Holding Register configuration table P 12 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 e Input Register Configuration ACI MOD9200 MODBUS Gateway Programming Software e Each row of the configuration table is a unique data register having 8 special a
11. such as SensorVull Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 14 of 42 ACI MOD9200 MODBUS Gateway Programming Software First we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu Select the appropriate function File Settings Points Row RegisterEntry Register Bank FUNCTION REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT ANALOG_INPUTS m4 DISCRETE_INPUTS OLDING_REGS 7 SENSOR_CNTRL T Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell When the RegisterEntry AutoSet is turned on REG ADDRESS is automatically filled with the next sequential number from 0 to 99 Turn AutoSet ON POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT Turn AutoSet OFF File Settings Points Row REG FUNCTION ANALOG INPUTS Again use the mouse to move to the next column Enter a GROUP NAME for the data set by typing the group name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use delimiters lt gt in the Group Name w HODBUS Configuration Tool File Comm Aow REG FUNCTION REG ADDRESS GROUP NAME POINT ANALOG INPUT p Sth Floor Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e Enter a POINT NAM
12. 0K See page 15 to set the Capture Time WH2630B D Space Temp Humidity pees OA2630A Outdoor Temp Outdoor OMONS Letter 20g wumy OPEN hem 208 OH2630A_ Outdoor Humidity e o Therm 20K DH2630A D_ Duct Humidity DH2630B C E F Duct Temperature Duct Humidity PR emaa FT2630A B Fluid Temperature a ES oem Totalizer 01 Count CH 03 Totalizer 02 Count CH 04 1K P 16 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 17 of 42 ACI MOD9200 MODBUS Gateway Programming Software Select the appropriate DATA FORMAT value by clicking in the cell to open a drop down menu DATA FORMAT ATD 1k RATO 1k Ext ANALOG DIGITAL HUMIDITY MOISTURE The LOG column is used to identify the file the register will be logged to when using SensorVull Monitoring and Logging software Enter the name of the appropriate log file specified in the SensorVulI LOG CONFIG menu The file names are case sensitive B Editor File Settings Points Row REG FUNCTION REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG ANALOG_INPUTS 0 5th Floor Conf Am A 38E 1 THERM 20k ENERGY _COOU To create a new data register row click on Row gt Append Continue to do this for each row data register that needs to be configured The completed configuration example for an office building is as follows File Settings Points Row RegisterEntry Register
13. Automation Components Inc User s Manual MOD9200D MODBUS Transceiver ACI MOD9200 MODBUS Gateway Programming Software License Agreement for Automation Components Inc Software IMPORTANT READ THESE TERMS CAREFULLY BEFORE INSTALLING THIS SOFTWARE THESE TERMS AND CONDITIONS ESTABLISH A CONTRACT BETWEEN YOU INDIVIDUALLY IF YOU ARE AGREEING TO IT IN YOUR OWN CAPACITY OR IF YOU ARE AUTHORIZED TO AGREE ON BEHALF OF YOUR COMPANY OR ANOTHER ORGANIZATION BETWEEN THE ENTITIY FOR WHOSE BENEFIT YOU ACT YOU AND ACI BY INSTALLING THIS SOFTWARE PACKAGE YOU ACKNOWLEDGE THAT YOU HAVE READ THIS LICENSE AGREEMENT THAT YOU UNDERSTAND IT AND THAT YOU AGREE TO BE BOUND BY ITS TERMS IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT OR IF YOU DO NOT UNDERSTAND THEM PROMPTLY RETURN THE UNOPENED PACKAGE AND ALL ACCOMPANYING ITEMS TO ACI FOR A FULL REFUND 1 Grant of License for Registered Users ACI grants you a non exclusive non transferable license to use the software program with which this license is distributed the Product including any documenta tion files accompanying the Product Documentation on any single computer You may use the Product on a second computer so long as only one 1 is used at a time 2 Backup Copy You may make one backup copy of the Product You may use it only to reinstall the Product 3 Ownership You have no ownership rights in the Product Rather you have a license to use the P
14. D Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software Table of Contents L notou NI oso ts pte sets rede pss E E E E J a MOD9200 Gateway System ccc ccccccccccccceceeeseeseeecceeeeesaaseeeeeeceeeeesaaaeneees 5 Ii MODBUS Transceiver Installation amp Network Setup 00 cc cceeeeeeeeeeeeeees 6 a Transceiver Installato eas nd sd seat ees ate ed ss cranes eet edt 6 b Network SC OUD x coicccsstcceceianosinasoin setedaratocerantsusdinnss nek ne ek AENA N EEN AE ie 7 c Setting A New IP Address cccccccccscssseccccceecceeseseeeeccceeeesaaaeeeecceeeeeseaaaneees 7 d Manually Resetting The Factory Default IP Address ee eeeeeeeees 9 HI Configuration Software 0 0 0 0 ccccccccccccccseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 a Configuration Software Description cccccccssssseeeecceeeeeeeeeceaaaaaeeeeseeeeess 11 b System Requirements ec tee scetcte yas secesssacestenee nieteean eau ate neodeussanenenecmeceseonadeaenedes 1 c Configuration Software Installation 0 0 cc ccccccccccccececeeeeeeeeeeeeeeeaaaeeeees 1 d Creating A MODBUS Configuration Fille ccccccccccceesneseeeeeeeeeeees 12 e Input Register Configuration 0 0 cc ccsssseesssssseeceeeeeeeeeeeeeeeaaaaaeeeeeeeeeees 13 f Digital Output Coil Register Configuration 0 cc ccsssseeeeeeeeee
15. E for the data point by typing the name in the cell Enter the name in the cell by using the mouse to click on the next column Note DO NOT use delimiters in the Point Name File Comm Row REG FUNCTION REG ADDRESS GROUP NAME POINT NAME TRE ANALOG INPUT Sth Floor Cont Arn e Assign a sensor transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell To select the address click on the appropriate ID in the drop down menu Each transmitter is factory configured with a unique ID refer to the sensor product data sheet for the location of the transmitter ID or Conf Am 4 P 15 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop down menu Click on the appropriate transmission channel 01 to 04 to select NAME TRANSMITTER ID TRANS CHAN TRANS TIMEQLIT try 3BE e The active transmission channels are factory configured as follows Analog CH 01 Analog CH 02 Digital CH 01 hie Therm 20K WT2630B Space Temp SetPoint Override Discrete Therm 20K Analog See page 15 to set the Digital Capture Time Therm 2
16. IAL PUNITIVE OR EXEMPLARY DAMAGES FOR LOSS OF BUSINESS LOSS OF PROFITS BUSINESS INTERRUPTION OR LOSS OF BUSINESS INFORMATION ARISING OUT OF THE USE OF OR INABILITY TO USE THE PROGRAM OR FOR ANY CLAIM BY ANY OTHER PARTY EVEN IF ACI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ACI S AGGREGATE LIABILITY WITH RESPECT TO ITS OBLIGATIONS UNDER THIS AGREEMENT OR OTHERWISE WITH RESPECT TO THE PRODUCT AND DOCUMENTATION OR OTHERWISE SHALL NOT EXCEED THE AMOUNT OF THE LICENSE FEE PAID BY YOU FOR THE PRODUCT AND DOCUMENTATION BECAUSE SOME STATES COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU 8 Export Restrictions THIS LICENSE AGREEMENT IS EXPRESSLY MADE SUBJECT TO ANY LAWS REGULATIONS ORDERS OR OTHER RESTRICTIONS ON THE EXPORT FROM THE UNITED STATES OF AMERICA OF THE PRODUCT OR INFORMATION ABOUT SUCH PRODUCT WHICH MAY BE IMPOSED FROM TIME TO TIME BY THE GOVERNMENT OF THE UNITED STATES OF AMERICA YOU SHALL NOT EXPORT THE PRODUCT DOCUMENTATION OR INFORMATION ABOUT THE PRODUCT AND DOCUMENTATION WITHOUT CONSENT OF ACI AND COMPLIANCE WITH SUCH LAWS REGULATIONS ORDERS OR OTHER RESTRICTIONS 9 Termination This License Agreement is effective until it is terminated You may terminate this License Agreement at any time by destroying or returning to ACI all copies of the Product and Documentation in your possession or under your control ACI may termin
17. P Address e The Gateway can manually be reset to the default IP Address by moving the jumper J6 from Norm to Init e Turn off the power to the Gateway and move the jumper from Norm to Init Turn on power and the Gateway can be communicated with using the Factory Default IP Address 192 168 0 1 Subnet Mask 255 255 255 0 The Config File is no longer active while the jumper is in the Init position A new Config File can be downloaded to the Gateway if desired e To reactivate the Config File turn off the power to the Gateway and move the jumper back to Norm Turn the power back on and the Config File will become active The Gateway will have the IP Address that was set in the Config File TCP IP APPLICATION NOTE When using the MOD9200D in TCP IP mode the MODBUS Master polling interval should be set to occur within 2 minutes 59 seconds or less If no polling activity occurs within 3 minutes the MOD9200D will automatically close the network connection and the MODBUS Master will have to close and re open the connection to re establish communications The MODBUS Master should not attempt to re open the network connection for at least 3 1 2 minutes after the network connection has been closed __ Only 1 TCP IP connection is allowed at a time P 9 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Softw
18. are P 10 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software HI Configuration Software a Configuration Software Description e The MODBUS data registers of the Gateway need to be configured prior to use The configuration program Trs Programmer exe can be found on the disk or CD ROM on the back cover of this manual will configure the data register as follows Assign the Input Register function Analog or Discrete Assign wireless Digital Output Coil Register function Assign wireless Analog Output Holding Register function Assign the register address Assign the Wireless Sensor ID and transmission channel Assign the data type e The MOD9200 Transceiver can have up to 100 addresses 0 to 99 data registers configured to be either Analog or Discrete 50 digital outputs and 50 analog outputs e Error registers are directly mapped to the data registers 400 addresses 400 to 499 For example errors for data register 55 will be in error register 455 b System Requirements e PC Notebook or desktop with Windows 98 XP Vista or Windows 7 e Ethernet connection e 10 MB of hard drive memory available c Configuration Software Installation e If other applications are running close them before inserting the ConfigTool CD into the CD ROM Drive The Programmer setup program should automatically start running Follow the on
19. ate this License Agreement for any reason including but not limited to if ACI finds that you have violated any of the terms of this License Agreement Upon notification of termination you agree to destroy or return to ACI all copies of the Product and Documentation and to certify in writing that all known copies including backup copies have been destroyed All provisions relating to confidentiality proprietary rights and non disclosure shall survive the termination of this Product License Agreement Additionally it is understood that termination of this Agreement will not effect a refund of any license fees paid or owed to ACI 10 General This License Agreement shall be construed interpreted and governed by the laws of the State of Wisconsin without regard to conflicts of law provisions thereof The exclusive forum for any disputes arising out of or relating to this License Agreement shall be an appropriate federal or state court sitting in the State of Wisconsin USA This License Agreement shall constitute the entire Agreement between the parties hereto Any waiver or modification of this License Agreement shall only be effective if it is in writing and signed by both parties hereto If any part of this License Agreement is found invalid or unenforceable by a court of competent jurisdiction the remainder of this License Agreement shall be interpreted so as to reasonably effect the intention of the parties P 2 of 42 Automation Components Inc MO
20. dress P 7 of 42 e The MOD9200 is shipped from the factory with an IP address of 192 168 0 1 and a subnet mask of 255 255 255 0 Note To initially connect to the Gateway the networked PC must have a Static IP address in the form of 192 168 0 X where X is gt 1 with a subnet mask of 255 255 255 0 e The IP Address is changed by changing the IP Address in the Gateway Config File Open either an existing config file or a new config file Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 8 of 42 ACI MOD9200 MODBUS Gateway Programming Software using the Programmer Software Click on Settings gt TCP IP Transport ec he File Settings Points Row RegisterEntry RE Unit Identifier gt GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG Serial Transport vV TCP IP Transport Miscellaneous Enter the new IP Address and Subnet Mask and click OK The new IP Address will take affect when the Config File is downloaded to the Gateway fi 92 168 0 1 255 255 209 0 Router Setup Webserver Only 192 168 0 254 Router IP Address Forwarded Port OK Cancel Router Setup Webserver Only NOT USE Applicable for RM9500 WebLogger Setup ONLY Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software d Manually Resetting The Factory Default I
21. e MOD9200 Gateway click on File gt File Transfer and a dialog box will appear Editor File Settings Row New Gateway File Open Gateway File Save Save As File Transfer Exit B File Transfer File Name r TCPIP 192 168 0 1 IP Address TCPAP G Comm Status Disconnected Connect Disconnect File Status Cancel P 31 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e Click on Select File and a window will open Move to the trs config directory and select the appropriate file from the list Trs Suite in1 Select File EJ Look in 9 config A SensorVull ini a3 2 Trs Suite ini My Recent Documents G Desktop My Documents PE My Computer p QQ My Network File name Te Suite ini Places Files of type Config files c treconfig ini Cancel e Click on Open to automatically enter the selected file path as the File Name e Enter the current IP Address of the Gateway Note This can be different than the IP Address entered into the configuration file P 32 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software File Transfer C trs4configi Trs Suite ini Fi
22. eeeeeeeeeeeeeaaaaseeeeeseeeees 4 a Installing The MOD9200 MODBUS Gateway ee eeeeeeeeeeeeeeeeeeeens 4 b Installing The MOD9200 Configuration Software 0 0 0 eeeeeeeeeeeeees 4 P 4 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software I Introduction The MOD9200 MODBUS network receiver utilizes reliable Spread Spectrum Mesh Network Radio technology When used with other wireless sensors the system can transmit remote sensor readings status alarm indications and control signals to a MOD9200 centralized networked monitoring station or controller MODBUS Gateway without the need for extensive wiring The MOD9200 is compatible with any control system or Programmable Logic Controller PLC panel that utilizes the TCP IP or RS485 RS232 RTU ASCH MODBUS communication protocols a MOD9200 Gateway System e MOD9200 MODBUS Network Receiver e Receives input from up to 50 remote wireless sensor modules and or wireless output modules RD2402 amp RD2431 per Transceiver e Signal repeater router can be used to extend the wireless sensor transmission distance if needed Ethernet Network Connection or RS485 RS232 Connection MOD9200 Configuration Software Wireless Wall Temp amp Humidity Sensor bS Wireless Remote Digital Analog f em a Input Modules amp E Totali o Fa nput Modules amp Energy lotal zer MODBUS Network _ N
23. ees 18 g Analog Output Holding Register Configuration 0 00 cc eeeeeeeeeeeeeees 20 h Setting the Mesh Network ID for the repeater router devices 23 i Miscellaneous Menu cccccccccccccccccccceeeeseeeessseseeeeeceeeeeeeeeeeeaaaaaaaseseeeeeees 23 j Configuring The Gateway For TCP IP MODBUS i eeeeeeeeeeeees 23 k Configuring The Gateway For RS485 RS232 RTU ASCIT MODBUS 26 l Sending The Configuration File To The MOD9200 ee eceeeeeees 31 m Activating The Config File 20 0 0 ccccsssesssseeececccceeeeeeeeeesaaaaaeseeeeeeees 33 IY Data A COUISIQION esis scccacesecceycessacecacusaqudetenaessueseaneessxiassterus E EEEE E Eiai 36 a MODBUS Standard cc cccccccccccccceeceaeeeeeeeeesseseeeeeeeeeeeeeeeeeaaaaaaeeeseseeeees 36 b MOD9200D MODBUS Transceiver Application Parameters 36 o The Input RGIS CC iS ioc asoscacuctissicesonseaiescsuapcevadsewecndsiapieenchiesdancioapcenathewesudiiuaeencioen 37 e The Digital Output Coil Registers ccccceccccceeeceaseeeeeeeeeeeeeaas 38 e The Analog Output Holding Registers 2 0 0 0 ccesscsssssseeeeeeeeeeeeeeees 38 The Alarm Registers s scescsesscaseceseasstacsrsaseees pete nessonasanesqiasbswsounrenciereseadaancongimaees 38 d BTM9010 SensorView Monitoring amp Logging Application 0 40 V Quick Setup IMstructioms cc cccccccccsssseeeseessseeeeeeee
24. ents Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software 192 168 0 1 IP Address 255 255 295 0 Subnet Router Setup Webserver Only 9 1680 254 Router IP Address Forwarded Port OF Cancel k Configuring The Gateway For RS485 RS232 RTU ASCIT MODBUS Protocol P 26 of 42 When using the MODBUS Serial Line communications protocol the Gateway needs to be assigned a unique Identifier Slave Address to differentiate it from other serial devices on the network To enter the Gateway Unit ID Slave Address into the Configuration File click on the Menu Comm gt Unit Identifier im Editor _ sunzet_lane_bl File Comm Row F IF Address ER H Unit identifie ANALOG INPUTS Click on the drop down menu arrow and select the Gateway Unit ID from the drop down menu and click OK The default Unit ID is 1 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 27 of 42 ACI MOD9200 MODBUS Gateway Programming Software REG ADDRESS GROUP NAME POINT HAME rs 0 Rth Floor Cont Am A rs 1 Ath Floor Conf Rim B rs 2 Ath Floor Cont Aim C rs T O Cancel Co J 2 7 Fe oo PB Click on Menu Comm gt Serial Transport to activate the Serial Comm Port dialog box Unit kientiher GROUP NAME POINT NAME v Serial Transport TCP IP Transport Network ID Miscellaneous Use the Serial C
25. etwork Wireless Digital s Relay Outputs Wireless Immersion amp p gt M l y Remote Sensors a MOD9200D Wireless Outside Air MODBUS Transceivers i T amp i l emperature B Wireless Digital Humidity Repeater Increases a a Transmission Distance if needed Sub System Overview P 5 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software II MODBUS Transceiver Installation amp Network Setup a Transceiver Installation e Choose a location close to the computer network hub or RS485 loop e Mount the gateway on the wall using four 8 screws e 24 VAC Input Connect 24VAC 60 Hz and earth ground to the input terminals using 18 AWG wire as shown in the product data sheet e TCP IP If using TCP IP use RJ45 Category 5 Ethernet cable to connect the Gateway J2 to the network hub or computer See Figure 1 e RS232 If using RS232 RTU ASCI use the MOD9200 RS232 cable sold separately to connect the Gateway J1 to the serial port on the computer See Figure 1 TCP IP Connection J2 Connection J1 Default IP Saag PROC Serr in Jumper ze Heo j 0 F00000m HI LO Bias Not Available TERM Resistor NA nest A maaar a i qi 4 VAC 24 VAC Bosne Input erminals Figure 1 e RS485 If using RS485 RTU ASCII use 18 gauge shielded twisted pair wire to connect the Gateway Terminals A
26. he MODBUS Client Server Model and utilizes the MODBUS messaging services over TCP IP or RS485 RS232 to communicate toa MODBUS Client e For implementation information please refer to the Modbus Standard Library at www modbus org Both the MODBUS Application Protocol Specification and the MODBUS Messaging On TCP IP Implementation Guide are available for download there b MOD9200D MODBUS Transceiver Application Parameters e When interfacing 3 party monitoring software or controllers to the MOD9200 Gateway be sure to set the appropriate MOD9200 Gateway Unit Identifier see page 18 and for TCP IP connect to the MOD9200 Gateway Port 0502 If either the Serial RTU mode or Serial ASCII mode are used connect through the appropriate COM serial port e TCP IP APPLICATION NOTE When using the MOD9200D in TCP IP mode the MODBUS Master polling interval should be set to occur within 2 minutes 59 seconds or less If no polling activity occurs within 3 minutes the MOD9200D will automatically close the network connection and the MODBUS Master will have to close and re open the connection to re establish communications The MODBUS Master should not attempt to re open the network connection for at least 3 1 2 minutes after the network connection has been closed Only 1 TCP IP connection is allowed at a time e The MOD9200 MODBUS Gateway receives data from up to fifty 50 wireless sensors and updates its data registers on a real time basis
27. ialog Screen Click on Settings gt Miscellaneous Unit Identifier POINT NAME TRANSMITTER ID TRANS CHAN m oy Serial Transport Sunshade 38E o TCP IP Transport Network ID hie een Set the transmitter transmission timeout interval requires a minimum of 30 min by clicking in the Transmitter Timeout cell to open a drop down menu Use the scroll bar to scroll down to the appropriate value 1 to 60 min or type the value in the cell to automatically scroll to the appropriate value This will be used to generate an error message if the transmitter fails to transmit in the specified time interval m Transmitter Timeout min r Digital Capture Time 240 Seconds C Minutes Digital Scaling Units Wo Digital Scaling On Degrees F Degrees C Register Value When Sensor Lost Retain Last Value Set to 19999 To select the timeout interval click on the appropriate value in the drop down menu The Digital Input Capture Time can be set to hold a momentary contact closure such as the override button on the WT2630B C for a period of time Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software Default is 0 min amp recommended value is 1 min so the controller has time to recognize the contact closure The Digital Capture Time can be set up to 240 minutes 4 hours in applications where a
28. ime 6 Limited Warranty ACI WARRANTS THAT THE PRODUCT WILL OPERATE SUBSTANTIALLY IN ACCORDANCE WITH THE THEN CURRENT DOCUMENTATION SHOULD THE PRODUCT NOT SO OPERATE YOUR EXCLUSIVE REMEDY AND ACI S SOLE OBLIGATION UNDER THIS WARRANTY SHALL BE AT ACI S SOLE DISCRETION CORRECTION OF THE DEFECT OR REFUND OF LICENSE FEES PAID BY YOU FOR THE PERIOD DURING WHICH THE DEFECT WAS NOT CORRECTED AND MATERIALLY AFFECTED THE OPERATION OF THE PRODUCT ANY USE BY YOU OF THE PRODUCT IS AT YOUR OWN RISK THIS LIMITED WARRANTY IS THE ONLY WARRANTY PROVIDED BY ACI REGARDING THE PRODUCT EXCEPT FOR THE LIMITED WARRANTY ABOVE THE PRODUCT IS PROVIDED AS IS TO THE MAXIMUM EXTENT PERMITTED BY LAW ACI DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ACI DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE PRODUCT WILL MEET ANY REQUIREMENTS OR NEEDS YOU MAY HAVE OR THAT THE PRODUCT WILL OPERATE ERROR FREE OR IN AN UNINTER RUPTED FASHION OR THAT ANY DEFECTS OR ERRORS IN THE PRODUCT WILL BE CORRECTED OR THAT THE PRODUCT IS COMPATIBLE WITH ANY PARTICULAR PLATFORM SOME JURISDICTIONS DO NOT ALLOW THE WAIVER OR EXCLUSION OF IMPLIED WARRANTIES SO THEY MAY NOT APPLY TO YOU 7 Limitation of Liability IN NO EVENT WILL ACI BE LIABLE TO YOU OR ANY THIRD PARTY FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION INDIRECT SPEC
29. le Name TCPIP 192 168 0 1 IF Address TCP IP cz Comm Statue Disconnected Connect Disconnect Fieisteadytobesent File Status O Sedme cear e Click on Connect and the status of the connection will be displayed in the Comm Status window When the Gateway is connected click on Send File to the send the config file to the Gateway m Activating The Config File e Once the config file has been sent to the Gateway it will become active immediately If you have changed the IP Address in the config file you will lose your connection and have to reconnect using the IP Address and Subnet Mask that was sent in the new config file P 33 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 34 of 42 ACI MOD9200 MODBUS Gateway Programming Software A File Transfer IC Atrstconfigi Trs Suite ini File Hame M TCFPAP 1 932 168 0 1 IP Address TCP IP ie Comm Status Disconnected Connect Disconnect A Fi Status Cancel To confirm that the appropriate configuration file is saved on the Gateway reopen the File Transfer Dialog and click on Get File to retrieve a copy of the active configuration file from the Gateway The Editor will automatically save this file in the folder trs config with the file name of _config ini Click on File gt Open Config File and select the _config ini file Click on Open
30. mal and data is displayed in counts 0 to 4095 For example the setpoint pot of the WT1630B is setup as an ANALOG data type with ranges from 0 Cool to 4095 Warm For the data type TOTALIZER there is no decimal and data is displayed in counts 24 bits When the count reaches 16 777 215 24 bits the count value rolls over to O and begins again Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e The Digital Output Coil Registers The MODBUS Coil Register 01 to 50 are used for command remote wireless digital outputs relays module 1 e ED2402D amp the SD2432D devices Values to be entered or sent is l on and O off The MODBUS Coil Register 101 to 150 will be automatically assigned by the MOD9200 These 50 registers will display the status of the relays commanded via the previous Register 01 thru 50 After the remote unit executed the command issued by the MOD9200 It will send a feedback status of the relays to the MOD9200 e The Analog Output Holding Registers The MODBUS Holding Register 40001 to 40050 are used to command remote wireless analog outputs 0 10VDC or 0 5 VDC module such as the D2432D devices Value to be entered or sent is from 0 to 4095 counts representing the full output range The MODBUS Holding Register 40101 to 40150 will be automatically assigned by the MOD9200BNT These 50 registers objects
31. n extended period of time is needed such as unoccupied period by pass Set the Digital Capture Time interval seconds or minutes by clicking on Seconds or Minutes Click in the Digital Capture Time cell to open a drop down menu Use the scroll bar to scroll down to the appropriate value 0 to 240 or type the value in the cell to automatically scroll to the appropriate value To select the timeout interval click on the appropriate value in the drop down menu Digital Scaling On check box Should be UNCHECKED Check only when configuring the MOD9200BNT BACnet receiver or the MOD9200LON LonWorks Receiver Units Select the appropriate default temperature scale F C Register Value When Sensor Lost The user has the options to select whether the sensor value should remain unchanged or set to 19999 when the communication link is lost with the sensor after the transmitter timeout period j Configuring The Gateway For TCP IP MODBUS P 25 of 42 Click on the menu Comm gt TCP IP to select the TCP IP configuration menu S K q Ero E 4 File Points Row RegisterEntry Register Bank IRE Unit Identifier 5 GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG Serial Transport TCP IP Transport Network ID Miscellaneous Type in the appropriate IP address and click OK The TCP IP transport protocol is automatically setup Automation Compon
32. nsport mode requires 7 bits and Extended ASCII requires 8 bits e The number of Data Bits needs to be the same as in the Master configuration Serial Comm Port Properties Maximum Speed S600 Modbus Transport Connection Preferences fe ATU ASCII Data Bits E Parity Iz Stop Bits 1 T A ance P 28 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e Parity is used for simple error checking Select the proper Parity even odd or none by clicking on the selection arrow and selecting either even odd or none If none is selected 2 stop bits are required e Parity needs to be the same as in the Master configuration 5 Serial Comm Port Properties Maximum Speed a600 z Modbus Transport i i Connection Preferences ATU Data Bits 7 Prarity fe ASCII Stop Bits OF Cancel e The appropriate number of Stop Bits depends on the Parity selected If even or odd parity is selected 1 stop bit is used If a Parity of none is selected 2 stop bits are used Select the Stop Bits by clicking on the selection arrow and selecting either 1 or 2 Stop Bits need to be the same as in the Master configuration 5 Serial Comm Port Properties M asimum Speed a600 Modbus Transport Connection Preferences fe RTU C ASCII
33. omm Port configuration dialog box to select the appropriate internal communication parameters Connect Speed Connect Preferences and Transport Mode for the Transceiver Properties Maximum Speed 38400 x Modbus Transport Connection Preferences RTU ASCII Data Bits g Parity Stop Bits 1 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software e There are two different serial transmission modes defined in MODBUS the RTU mode and the ASCII mode They define the bit contents of the message fields transmitted serially on the line and determine how information is packed into the message fields and decoded e The MOD9200 transmission mode and serial port parameters need to be exactly the same as those configured for the Master e Select the Maximum Speed In the Serial Comm Port configuration window click on the drop down selection arrow and select the Maximum Speed for communication speeds range from 9600 bps to 38400 bps e Communications speed needs to be the same as in the Master configuration Serial Comm Port Properties Masinun Speed Modbus Transport Connection A C RTU i ASCII Data Bits Parity Stop Bits 1 a z ance e Select the number of Data Bits click on the selection arrow and select either 7 or 8 bits The RTU transport mode requires 8 bits Standard ASCII tra
34. ompatible with Excel and other Office applications The logged information can be easily retrieved for additional energy and performance analysis The BTM9010 system is suitable for energy monitoring and audit applications building performance diagnostics high temperature building treatment and other applications Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software V Quick Setup Instructions a b P 41 of 42 Installing The MOD9200 MODBUS Gateway 1 Locate the Gateway close to a computer 10 100 Base T network hub or RS485 RS232 connection 2 Connect the Gateway to the TCP IP network using RJ45 Category 5 Ethernet cable or a crossover cable see Fig page 4 3 Apply 24 VAC 60 Hz power to the input terminals of the Gateway The Gateway current draw is less than 0 1 Amp 4 The Gateway is shipped with an IP address of 192 168 0 1 and a subnet mask of 255 255 255 0 see page 8 for instructions on changing the IP address Note To initially connect to the Gateway the networked PC must have a static IP address with a subnet mask of 255 255 255 0 5 The Gateway is ready to be configured Installing The MOD9200 Configuration Software 1 Insert the Programmer 6 00 X disk or CD into the CD ROM Drive the setup program should start automatically If the setup program does not start automatically click on Start gt Run
35. roduct as long as this License Agreement remains in full force and effect Ownership of the Product Documentation and all intellectual property rights therein shall remain at all times with ACI Any use of the Product by any other person business corporation government organization or any other entity is strictly forbidden and is a violation of this License Agreement You may not make more copies of the Product than specified in this agreement or allowed by applicable law despite this limitation publish the Product for others to copy or rent lease or lend the Product 4 Copyright The Product and Documentation contain material that is protected by United States Copyright Law as well as other intellectual property law and international treaty provisions All rights not granted to you herein are expressly reserved by ACI You may not remove any proprietary notice of ACI from any copy of the Product or Documentation 5 Restrictions You may not publish display disclose rent lease modify loan distribute or create derivative works based on the Product or any part thereof You may not reverse engineer decompile translate adapt or disassemble the Product nor shall you attempt to create the source code from the object code for the Product You may not transmit the Product over any network or between any devices although you may use the Product to make such transmissions of other materials You may access the Product from only one computer at a t
36. tal or relay output TRANS CHAN to the data register by clicking in the cell to open a drop down menu Click on the appropriate transmission channel 01 to 04 to select P 22 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software NAME TRANSMITTER ID TRANS CHAN TRANS TIMEOUT e The active transmission channels or output number are factory set as follows Device Digit a Amalog and relay 2 output module to relay 4 output to 4 analog output module h Setting the Mesh Network ID for the repeater router devices CURRENTLY EDTING ANALC Row RegisterEntry Register Bank Unit Identifier POINT NAME TRANSMITTER ID TRANS CHAN Serial Transport SunShade Ed TCP IP Transport Network ID e ar e The mesh network ID of the MOD9200 Gateway can be set to specific network from 1 to 64 The MOD9200 functions as a network coordinator Any repeater router that has the same network ID will be able to communicate and channel sensor information to the MOD9200 i Miscellaneous Menu P 23 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 24 of 42 ACI MOD9200 MODBUS Gateway Programming Software The transmitter timeout interval default temperature degrees C F and Digital Input Capture Time are set globally for all sensors using the Miscellaneous D
37. to open the file in the Editor Confirm that the file is the same as the original configuration file File Settings Points Row REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG ANALOG_INPUTS 0 3rd Floor Sensors Temp 33BC 33BC 1 THERM 20k ENERGY_COOL ANALOG_INPUTS 1 3rd Floor Sensors RH 33BC 33BC 2 HUMIDITY HUMIDITY ANALOG_INPUTS 2 3rd Floor Sensors Temp 338D 33BD 1 THERM 20k ENERGY_COOL ANALOG_INPUTS 3 3rd Floor Sensors RH 338D 33BD 2 HUMIDITY HUMIDITY ANALOG_INPUTS 4 3rd Floor Sensors Temp 33BE 33BE 1 THERM 20k ENERGY_COOL ANALOG_INPUTS 5 3rd Floor Sensors RH 33BE 33BE 2 HUMIDITY HUMIDITY ANALOG_INPUTS 6 3rd Floor Sensors Temp 33BF 33BF 1 THERM 20k ENERGY_COOL Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 35 of 42 ACI MOD9200 MODBUS Gateway Programming Software NOTE The _config ini file is a dynamic file If multiple MOD9200 Gateways are being administered from the same PC the _config in1 file will be a copy of the configuration file from the last Gateway administered Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 ACI MOD9200 MODBUS Gateway Programming Software IV Data Acquisition a MODBUS Standard e MODBUS is an application layer messaging protocol for client server communication between devices connected on different types of buses or networks e The MOD9200 functions asa MODBUS Server in t
38. ttributes REG FUNCTION REG ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG P 13 of 42 Identifies the function of the register Analog or Digital Discrete Note If selecting the Digital Discrete function be sure to set the appropriate Digital Capture Time Page 15 Assigns the address of the data register 0 to 99 Automatically assigns the address of the error register 400 to 499 1 e data register address 400 Assigns a group name to the data register Multiple data registers can have the same group name This is useful for monitoring and data logging programs Assigns a unique name to the data register to help identify the location of the sensor transmitter Multiple point names can have the same group name Assigns a wireless sensor transmitter address to the data register Each wireless sensor is factory configured with a unique hexadecimal address Assigns a wireless sensor transmitter data channel to the data register A wireless sensor transmitter may have up to four 4 analog channels and 4 digital status alarm channels Assigns the data type to the register temperature RTD or Thermistor 20K analog voltage totalizer or humidity This register is left blank if the REG FUNCTION 1s Digital Discrete Assigns the data register to a log file so the data can be logged over time This field is only used when the gateway will be used with a data logging program
39. will display the status of the analog output commanded via the previous Register 40001 thru 40050 After the remote unit executed the command issued by the MOD9200 It will send a feedback status of the analog output value to the MOD9200 e The Alarm Registers The MODBUS Register 30401 to 30500 are the alarm registers for all the input and output data points Input Register 30001 to 30100 Coil Register 101 to 150 and Holding Register 40101 to 40150 Each point utilizes 6 binary bits of information representing the alarm conditions of the Input Register Digital Output Coil Register and Analog Output Holding Register P 38 of 42 Automation Components Inc MOD Rev 8 0 2011 2305 Pleasant View Rd Middleton WI 53562 P 39 of 42 ACI MOD9200 MODBUS Gateway Programming Software Holding Register Input register Bit 5 amp 6 Bit 1 amp 2 000000 a Coil Register Bit 3 amp 4 The Present Value of each register displays a decimal value representing the alarm status of all 3 point types Each point type returns an individual alarm value in decimal format All 3 point types decimal values are added together to represent the status of the 3 alarm status The decimal values of different point types are The Input Register alarms Normal Low Battery Alarm Bit 1 set a 2 Lost Communication Alarm Bit 2 set The Digital Output Coil Register alarms 0 Normal