Contents
1. terminal screws are tightened excessively it may damage the screws and the module resulting in a short circuit or a malfunction e Be careful not to let any foreign particles such as chips and wire burrs get inside the module They may cause a fire as well as a breakdown or a malfunction of the module e Make sure to place the communication cable and the power cable to be connected to the module in a duct or fasten them using a cable clamp If the cables are not placed in a duct or fastened with a cable clamp their positions may become unstable or moved and they may be pulled inadvertently This may damage the module and the cables or result in a malfunction because of poor cable contact e When disconnecting the communication cable and the power cable from the module do not pull the cables by hand Loosen the screws in the part of the cable connected to the module and then remove the cable If the cable is pulled while being connected to the module it may damage the module or the cable or result in a malfunction because of poor cable contact Revisions The manual number is indicated in the right bottom of the front cover of this manual Date Manual Number Oct 2001 IB NA 0800208 A First printing O This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held respons
2. Box 39733 Bramley 201 8 Johannesburg South Africa Tel 27 11 444 8080 Messung Systems Put Ltd Electronic Sadan NO 111 Unit No15 M 1 D C BHOSARI PUNE 411026 Tel 91 212 793130 Mitsubishi Electric Asia Pte Ltd 307 ALEXANDRA ROAD 05 01 02 MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 Tel 65 470 2480 Country Region Sales office Tel Indonesia Thailand Hong Kong China Taiwan Australia P T Autoteknindo SUMBER MAKMUR Kompleks Agung Sedayu Propertindo Harco Mangga Dua Blok H No 4 JI Mangga Dua Raya Jakarta Pusat 10730 Indonesia Tel 62 21 336292 F A Tech Co Ltd 1138 33 34 Rama 3 Road Yannawa Bangkok 10120 Thailand Tel 66 2 295 2861 Ryoden International Ltd 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 Ryoden International Shanghai Ltd 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd Shanghai 200233 China Tel 86 21 6475 3228 Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd RD Wu Ku Hsiang Taipei Hsine Taiwan R O C Tel 886 2 2299 2499 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PostalBag No 2 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 QD351D 1 2 U HW JE Model code 13JT75 sa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100 8310 TELEX J24532 CABLE MELCO TOKYO NAGOYA WORKS 1 14 YADA MINAMI 5 HIGASHI KU NAGOYA JAPAN Spec
3. Intelligent Communication Module User s Manual before using this module 1 Overview This manual explains the specifications handling and names of component sections of the QD35ID1 QD35ID2 ID Interface Module hereinafter called ID Interface Module This module is compatible with the D 2N Series batteryless type Please check that the following items are included in the package ID Interface Module ID Interface Module User s Manual Hardware 2 Performance Specifications The following shows the performance specifications of the ID Interface Module QD35101 QD351D2 Connectable reader writer D 2N422RW C2 D 2N422RWS C2 Number of connectable 1 2 reader writers D NS422CAB10 10 m D NS422CAB20 20 m Connectable cable D NS422CAB40 40 m D NS422CAB100 100 m Maximum of two cables can be combined Data carrier that can be used D 2N03PS D 2N03PM Occupied points 32 points Occupied slot 1 slot ea a ae a 5VDC 0 40 A power supplied internally from 0 42 A power supplied internally from Curent the PLC the PLC External power supply 0 17A 0 33 A 24 V DC 0 13 kg 0 14 kg A reader writer and a data carrier are required in order to use the ID Interface Module For general specifications refer to the User s Manual of the PLC CPU to be used 3 Handling 3 1 Precautionary Item when Handling 1 Do not drop or apply severe shock to the module case since it is made of resin 2 Tighten the
4. MITSUBISHI ID Interface Module User s Manual Hardware QD35ID1 QD35ID2 Thank you for buying the Mitsubishi general purpose programmable logic controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MELSEE Q Mitsubishi Programmable Logic Controller 2001 MITSUBISHI ELECTRIC CORPORATION e SAFETY PRECAUTIONS e Please read the following before using the product When using this product please read this manual as well as the related manuals that are referenced in this manual and make sure that strict attention is paid to the safety and proper use of the product The precautionary notes in this manual cover only this product For the precautionary notes regarding the safety of the entire system using this product please read the User s Manual of the CPU module In this manual two levels of safety precautions Danger and Caution are used as shown below Improper handling may result in a dangerous situation leading to DANGER severe injuries and possible death Improper handling may result in a dangerous situation leading to CAUTION slight to moderate injuries and material damages Items marked by A CAUTION however may also result in serious consequences Please pay attention to this safety information as well Please keep this manual for reference and be sure to attach it to the product when the product is transferred to anot
5. al power supply by reversing the polarities of 24 V and 24 G If they are connected in reverse the ID Interface Module will not operate 5 2 Wiring of the Power Supply Terminals Perform the wiring of the power supply terminals as shown in the figure below IN 24VDC To external power supply 24V To 24 V GND 5 3 Connecting and Disconnecting the Reader Writer and the Cables The following shows how to connect and disconnect the reader writer and the cables 1 Connecting 1 Insert the convex part of the plug into Concave part the concave part of the jack h ee Convex part 2 Insert the plug securely into the position until the plug locks you will hear a click sound Re 2 Disconnecting pes 1 Release the lock by pulling the lock release mechanism section of the plug X in the direction of the arrows gt te 2 Hold and pull the plug in the direction of the arrow 6 External Dimension Diagrams The following figure shows the external dimensions of the QD35ID1 The external dimensions of the QD35ID2 are also the same QD35ID1 RUN DC24V SD RD ERR R Bending radius near connector 40mm Unit mm Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faul
6. her location or party DESIGN PRECAUTIONS e Provide a safety circuit externally to the PLC so that the safety of the overall system is always maintained in case of an external power supply failure or a PLC main unit breakdown Accidents may occur due to an erroneous output or a malfunction e Design the circuit in such a way that the external power supply is turned on after the PLC main unit is powered on Turning on the external power supply first may cause accidents due to an erroneous output or a malfunction CAUTION e Do not bundle the reader writer cables together with the main circuit or the power cable and do not install them close to each other They should be installed at least 100 mm away from each other Failure to do so may generate noise resulting in a malfunction INSTALLATION PRECAUTIONS CAUTION e Use the PLC in an operating environment that meets the general specifications described in the manual Using the PLC in any other operating environments may cause an electric shock a fire or a malfunction or may damage or degrade the PLC e Before installing the module securely insert the module fastening latch at the lower part of the module into the installation hole on the base unit Q Series modules must be fixed to the base unit with screws using the specified torque If the module is not installed properly it may cause the module to malfunction fail or fall off e Tighten the installation scre
7. ible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2001 MITSUBISHI ELECTRIC CORPORATION CONTENTS eR GNIS AU ch Mtr eee e Tere eee ee eee er rrr rrr Tre 1 2 Performance Specifications w ccccccscsceceeessssead cccnecceeeseseeeeuec cs eeeeessenanessveueeete 1 500 f 10 epee meee ea er EEEE 2 3 1 Precautionary Item when Handling cccccccceeeeeeeceeeeeeeeeeseeeeenneeeeees 2 3 2 Installation Enviroment vesscsseesessseeee A en 2 3 3 Cable installation ice cccccneeccrrecersccncantncncany ce euauussuuuiennuuee aiacetitiieets 2 4 Names of Component Sections cccceecccceeeeeeeeeeeeneeeeeeeeeeeeeeeseneeaeeeees 2 SOA AC ale preempt eemerent ct cc oes ton nt nits ietee nnn teatime mmeaenanat tana saatnn te 4 5 1 WINING Preca tionsS cacti utili cere ecard eee eatUunnNtNN 4 5 2 Wiring of the Power Supply Terminals cccccceeeeeeeeeeeeeeeeeeeeeees 4 5 3 Connecting and Disconnecting the Reader Writer and the Cables 5 6 External Dimension Diagram Ss cc iciiacie i ccceccdeedeidencececeesl ali aa 6 About the Manuals The following table lists manuals regarding this product Use this table to order necessary manuals respective to the functions used Related Manuals Manuals Manual name Manual No Model code Q Corresponding ID Interface Module User s Manual of 080199 QD35ID1 QD35ID2 13JT76 Please read the
8. ifications subject to change without notice Printed in Japan on recycled paper
9. iter connection Terminal for connecting 24 V power supply and Class D grounding Class 3 grounding Power supply terminal 1 LED display list LED name Display contents On Flashing O Off Normal operation displa Transmission status display Data being Not transmitted transmitted RD __ Reception status display Data being received SD ERR Error status display Error has occurred Normal reader writer 5 Wiring The following explains the wiring of the ID Interface Module 5 1 Wiring Precautions External wiring that is not easily affected by noise is required as one of the conditions to make a full use of the functions of the ID Interface Module and to configure a highly reliable system The following describes the precautions on the external wiring of the ID Interface Module 1 Do not wire the ID Interface Module close to or bundle with the main circuit cable a high voltage power cable or a load cable from other than the PLC Failure to follow this instruction may make the ID Interface Model susceptible to noise and surge induction They should be installed at least 100 mm away from each other 2 If a group of devices such as an inverter and a servo motor are to be used always ground them using Class D grounding Class 3 grounding Otherwise they may be affected by the electromagnetic field from the module main unit and the cables and there is the risk of malfunction 3 Do not connect the extern
10. terminal block and module installation screws within the specified torque range as follows Tightening torque range Terminal block terminal screws M3 42 to 58 Necm Module fixing screw normally not required M3 1 36 to 48 Necm 1 The module can be easily fixed onto the base unit using the hook provided at the top of the module However it is recommended that the module will be secured with the dedicated installation screws if it is subject to significant vibration or shock 3 2 Installation Environment For further details refer to the user s manual for the CPU module used 3 3 Cable installation When connectiong a reader writer cable or an extension cable to ID intaface module be sure that excessive force does not apply to the connector connection of the module ID interface module Connector connection section Reader writer cable Extension cable The bending radius for installation should be 40mm or longer lt 4 Secure the cable so that excessive external force does not apply the connector connection 4 Names of Component Sections QD351D1 QD351D2 RUN DC24V SD RD ERR READER WRITER QD35ID1 RUN C DC24V pen E CI WES G ERR C_ Co RN COI o DC24v 9C CID CHT pod COAR 2 ERCI CER DX Name Contents S LED displa LED display Refer to 1 for the display contents Reader writer connector Connector for reader wr
11. ts in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties N For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Brazil U K Germany South Africa India Singapore Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 Tel 1 847 478 2100 MELCO TEC Rep Com e Assessoria Tecnica Ltda Av Rio Branco 123 15 and S 1507 Rio de Janeiro RJ CEP 20040 005 Brazil Tel 55 21 221 8343 Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Herts AL10 8XB UK Tel 44 1707 276100 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 MSA Manufacturing Pty Ltd P O
12. ws within the specified torque If the screws are loose it may cause the module to fall off or malfunction If the screws are tightened excessively it may damage the screws and the module and cause the module to fall off or malfunction e Connect the reader writer cables securely to the connectors of the module After connecting make sure to check that the cables are not loose If the cables are loose poor cable connections may cause erroneous inputs and or outputs e Do not directly touch the conducting parts and electronic parts of the module It may cause the module to malfunction or fail WIRING PRECAUTIONS CAUTION e Before starting any installation or wiring work make sure to shut off all phases of the power supply externally Failure to completely shut off all phases of the power supply may result in an electric shock as well as a damage or a malfunction of the product e Always ground the FG terminal using Class D grounding Class 3 grounding or higher designated specifically for the PLC Otherwise there is a risk of an electric shock or a malfunction e Wire correctly to the PLC upon checking the rated voltage and terminal layout of the product Connecting a power supply not having the rated voltage or conducting incorrect wiring may cause a fire or a breakdown e Tighten the terminal screws using the specified torque If the terminal screws are loose it may cause the module to short circuit or malfunction If the