Home

IO-NET Programmable Control System. A Product Overview

image

Contents

1. It provides a convenient method of mounting IO NET hardware within a rack cabinet or other enclosure The printed circuit boards are mounted on the grearplate using nylon push on printed circuit board standoffs part no HW0130 The space at the top of the gear plate has mounting holes for a 24 volt power supply FP0474 or alternatively another termination board e g second 16 Way Relay Board can be mounted horizontally Material 1 6 mm mild steel Finish Zinc plated amp colour passivated Ship Wt 2 3 kg Part No FA1185 Dim mm 430 x 450 x 10 IO NET Gear Plate FA1185 Page 6 IO NET Cabinet The IO NET Cabinet is capable of containing the following arrangements 1 x IO NET Controller plus 3 x 32 Way Termination Boards or 16 Way Relay Boards 2 x IO NET Controllers plus 5 x 32 Way Termina tion Boards or 16 Way Relay Boards For this arrangement the Controllers are mounted on the inside of the door with adhesive standoffs HW0208 with flat ribbon cabling across to the Termination Boards The cabinet part number ME0088 comes complete with a 003 cam lock Australian standard while ME0089 has a 60124 lock NZ standard A gear plate is not necessary for mounting IO NET components in this cabinet The back plate of each cabinet is pre drilled with mounting holes to suit a variety of PCB mounting arrangements and is supplied with a quantity of loose PCB standoffs that can be fitted in the appropriate holes t
2. Unit Power Supply 24V 0 5A Mimic Display Board 3mm LEDs Mimic Display Board 5mm LEDs 16 Way Unprot Term Bd c w Resistors IO NET Controller PROM standard IO NET Compiler included in PA0700 IO NET Controller PROM large mem IO NET is also available from LT0185 IO NET Programmable Control System Product Overview V1 0
3. A inductive Cable Termination Capacity 1 5 sq mm max Ship Wt 350 g Part No PA0470 Dim mm 27 0 x 93 x 25 16 Way Relay Board PA0470 RZDU to RS232 Interface The RZDU to RS232 Interface is a small printed circuit board that converts Remote Zone Display Unit serial communications from a fire indicator panel into RS232 compatible signals This module is required for an IO NET Controller to receive information from a compatible Vigilant fire alarm panel Operating Voltage 17 to 30 volts dc Current 5 mA Part No PA0481 Dim mm 104 x 72 x 23 ShipWt 100 g RZDU to RS232 Interface PA0481 RS485 Fibre Optic Radio Interface This uses non proprietary items therefore consult distributor Page 5 IO NET System Components 1200 Baud Modem The 1200 Baud Modem is an optional component of an IO NET system It is required for IO NET data communications over non metallic media or over telecommunications circuits where Austel approval is required or for communication over long distances Refer to the User Manual for the details of wiring between the Modem and the Controller Voltage 5 volts dc from IO NET Controller Current 15 MA Austel permit A94 37D 0100 Dim mm 130 x 49 x 23 Part No PA0464 ShipWt 100 g 1200 Baud Modem PA0464 IO NET Gear Plate The IO NET gearplate is predrilled with mounting holes for an IO NET Controller and Termination Boards or 16 Way Relay Boards
4. T PROM Larger memory Programming Lead LM0041 SF0087 IO NET Controller PROM LT0185 IO NET Programmable Control System Product Overview V1 0 Page 7 IO NET System Components Other Products Some of the other products that can be used with IO NET are listed below Modbus Bridge The Modbus Bridge is used to interface an IO NET system with a Building Management System or other third party monitor ing system It makes the input status of all IO NET Controllers and the zone status of any connected fire alarm panels available in the widely supported Modbus communications protocol Part No FP0675 Dim mm 450 x 280 x 80 ShipWt 5 5 kG Picture Frame Display Cabinet This is a low profile metal cabinet with a lockable front opening door The door is covered by a translucent acrylic panel making it an ideal enclosure for wall mounted mimic and or control panels Internal mounting arrangements are provided for up to four Mimic Display Boards and up to two IO NET Controllers Part No ME0073 Dim mm 550 x 440 x 58 ShipWt 5 kg Mimic Display Board The Mimic Display Board contains 16 red LEDs positioned in line at 12 7 mm centres to provide index lamps for a mimic panel Two versions of the board are available PA0753 has 5mm LEDs that extend 25 mm so as to protrude through the acrylic door panel of the Picture Frame Display PA0738 has shorter 3 mm LEDs and mounts behind a mimic panel with the LEDs v
5. gramming module Logic equations are typed into the compu ter and saved as a text source file A compiler program operating on the PC generates the program file and downloads it into the PROM If program size permits each PROM may be repro grammed several times before it becomes full and must be replaced To assist with IO NET system setup and trouble shooting a diagnostics program is provided with the IO NET programming unit and compiler This enables the system data to be viewed on a per sonal computer The IO NET Controller is a single printed circuit board Demountable terminals for the power supply connection 24 volts dc and the serial data communications are located at one end of the board Input and output plug in connectors are located on each side of the board These must be connected to separate termination boards using flat ribbon cable looms Part No Dim mm ShipWt PA0498 270 x 165 x 25 310g Page 3 IO NET System Components mu al E E SAT A RL o Ned zaia Za rie te ye ye 32 Input Protected Termination Board 16 amp 32 Input Protected Termination Boards The 16 Input and 32 Input Protected Termination Boards are used for connecting field wiring to the IO NET Controller These termination boards include transient Suppression components to protect the IO NET inputs from electrical tran sients They must be used to terminate all IO NET Controller input cabling that extends beyond the IO NET encl
6. h TANI ALP ne ah PE MAHA IO NET Controller PA0498 IO NET Controller Each IO NET Controller has 32 digital inputs and can provide up to 32 programmable outputs From this starting point the system can be expanded up to a maximum of 128 Controllers on one IO NET communications line although physical constraints may limit a system to less than this At least 32 Controllers can be supported on a 1mm line up to 3 km long Each Controller also supports a high level Remote Zone Display Unit input link from a compatible Vigilant fire alarm system This makes the locally connected fire alarm system zone states available to the output logic of that Controller In addition the data from the high level input link of up to eight Controllers can be sent over the IO NET system and so made available to the output logic of all other Controllers Without programming apart for setting address switches up to 32 IO NET Controllers can function as a point to point telemetry system enabling the status of individual inputs to be transferred to outputs over a pair of wires This means that for this application up to 512 inputs at one point 16 Controllers can be repeated as 512 outputs at a second point while at the same time 512 inputs at the second point can be repeated at the first point Alternatively the Controllers could be distributed throughout a site In this case each Controller would send its input state to and receive its outp
7. he wiring is not extended beyond the IO NET Controller enclosure Typical uses include connection of mimic lamps and control panel switches to an IO NET Control ler A version of this board is available for connec tion to LEDs without their own current limiting The current limiting 3k3 series resistors set the current to approximately 7 mA from 24Vdc High efficiency LEDs must be used Cable Termination Capacity 1 5 sq mm max Part No Dim mm ShipWt PA0483 no resistors 69x46x18 100g PA0769 c w resistors 69x46x18 100g mm si Li ts a oe SSPE EEE DS 16 Way Unprotected Termination Board c w Resistors PA0769 Termination Board Looms Each termination board requires a Flat Ribbon Cable FRC loom to enable it to be connected to the Controller Looms are available in a variety of lengths as listed below Part No Length m Ship Wt LM0049 0 25 20 g LM0046 0 5 30 g LM0056 1 4 70 g LM0044 2 0 95 g LM0045 5 0 220 g Loom 0 5 metre FRC LM0046 LT0185 IO NET Programmable Control System Product Overview V1 0 IO NET System Components 16 Way Relay Board The 16 Way Relay Board has the same physical dimensions and footprint as the 32 Way Protected Termination Board It comes complete with a 1 4 metre flat ribbon cable for connection to one of the IO NET output connectors Relay Coil Current 12 mA at 24 volts Contact Configuration Single pole changeover 30V 2A resistive 1
8. i i MERI i R g IKI basal bead PA ITE sk SOP EA ALAA Sg ed eae Pedal QL AD Fee iniii Prhe H ocra PI FIRE amp EVACUATION SYSTEMS y VIGILANT IO NET Programmable Control System Description IO NET is a low cost distributed field programma ble control system that combines flexible control with networking communication facilities It han dles small or large numbers of inputs and or outputs whether concentrated at a single location or distributed over a wide area All inputs are multi level and can therefore provide the line supervision of input wiring often required for alarm applications In addition the IO NET Controller can receive high level communications from a fire alarm system and use that information as additional input conditions for control logic This combination of features makes IO NET suitable for a wide range of control and telemetry applications e g Alarm monitoring AS 1668 Fire Fan Control Mimic display of alarms PLC with remote indication Point to point telemetry Remote annunciation Stand alone PLC IO NET uses a proprietary token passing bus communication protocol that ensures efficient network operation Peer to peer communication is easily achieved as no master station is required to control network traffic The network continues to function quickly even when the volume of informa tion to be transmitted is high A 2 wire data only or a 3 wire data and powe
9. isible through holes in the panel Both PCBs connect directly to the output connectors on the IO NET Controller via standard flat ribbon cables Part No Dim mm Ship Wt PA0738 248 x 98 x 16 100 g PA0753 248 x 98 x 28 100 g IO NET is a product of Vigilant Fire amp Evacuation Systems 211 Maces Road Bromley Box 19 545 Christchurch 8006 New Zealand Distributed in Australia by Grinnell Detection Products 16 18 Shearson Crescent Mentone VIC 3194 Telephone 03 9584 2544 Fax 03 9584 6134 Page 8 System Part Numbers FP0474 FP0675 FA1185 HW0130 HW0208 LM0041 LM0044 LM0045 LM0046 LM0049 LM0056 LT0115 ME0073 ME0088 ME0089 PA0464 PA0470 PA0474 PA0475 PA0479 PA0480 PA0481 PA0483 PA0498 PA0700 PA0736 PA0738 PA0753 PA0769 SF0087 SF0088 SF0139 Power Supply 24V 2 5A Modbus Bridge IO NET Gearplate PCB Standoff 6 25 mm mounting PCB Standoff adhesive base Programming Lead included in PA0700 Loom 2 metres Loom 5 metres Loom 0 5 metres Loom 0 25 metres Loom 1 4 metres IO NET User Manual included in PA0700 Picture Frame Display Cabinet IO NET Cabinet 003 Lock IO NET Cabinet 60124 Lock 1200 Baud Modem 16 Way Relay Board 32 Input Protected Termination Board 32 Output Protected Termination Board 16 Input Protected Termination Board 16 Output Protected Termination Board RZDU to RS232 Interface 16 Way Unprotected Termination Board IO NET Controller IO NET Programming
10. it to the serial port of the PC and to the 24 volts power supply Generate or edit a text file containing the required logic equations on the PC compile the text file using the program LT0115 IO NET User ming software then download it into the PROM in the Programming Unit Turn off the power supply to the Programming Unit remove the PROM and i rika NA m aG Wt insert it back into the IO NET Controller The agian an 5 g programming process is complete F0088 si i LT0115 230 x 325x 7 450 g Note The Programming Lead LM0041 the IO NET Compiler SF0088 and the IO NET User Manual LT0115 are all included when Part No PA0700 IO NET Programming Unit is ordered IO NET Controller PROM This is a blank replacement microprocessor PROM for the IO NET Controller It comes already for use in the non programmed mode operation of the IO NET Controller and has completely blank user program space for operation in programmed mode A standard Controller PROM part number SF0087 is supplied inserted into each IO NET Controller and if program size permits this PROM may be reprogrammed a number of times Eventu ally the user program space will become full and a IO NET Programming Unit PA0700 replacement PROM must then be obtained For applications where the program size is larger than normal a PROM with more RAM and over 5 times more program storage capacity is available SF0087 IO NET PROM Standard memory SF0139 IO NE
11. o suit the particular arrangement There is also space in the cabinet for a small mains power supply PA0736 and standby battery Material 1 0mm mild steel Finish Baked epoxy powdercoat Cream Wrinkle BFF998CW Protection Category IP50 sealing can be added to increase protection to IP51 Part No Dim mm ME0088 003 lock ME0089 60124 lock ShipWt 494 x 449x 82 4 8kg 494 x 449x 82 4 8kg IO NET Cabinet ME0088 ME0089 Cabinet shown with Controller 16 Way Relay Board 16 Way Output Board 32 Way Input Board and Power Supply fitted These items are not supplied with the Cabinet LT0185 IO NET Programmable Control System Product Overview V1 0 IO NET System Components IO NET Programming Unit The IO NET Programming Unit transfers the program to the IO NET Controller PROMs This process is required for a controller to operate in programmed mode The Programming Unit is supplied complete with a cable to connect between the PC and the Programming Unit the compiler programming software for a PC and the IO NET User Manual An external 24 volts dc supply is required 19 2 to 28 3 volts Complete instructions on how to program an IO NET PROM are contained in the IO NET User Manual and this should be read before any pro gramming is carried out Briefly the process is as follows Remove the PROM from the IO NET Controller and insert it into the Programming Unit Connect the Programming Un
12. osure Cable Termination Capacity 1 5 sq mm max Part No Dim mm Ship Wt PA0479 16 Way 135x93x23 100 g PA0474 32 Way 270 x 93 x 23 200 g 32 Input Protected Termination Board PA0474 Page 4 seen eese Controller EEE WPS wes wee ewe Eee AN ANANA 16 Way Relay Board 16 amp 32 Output Protected Termination Boards The 16 Output and 32 Output Protected Termina tion Boards are used for connecting field wiring to the IO NET Controller These termination boards include transient Suppression components to protect the IO NET inputs from electrical tran sients They must be used to terminate all cabling that connects directly to IO NET Controller outputs and extends beyond the IO NET enclosure Cable Termination Capacity 1 5 sq mm max Part No Dim mm Ship Wt PA0480 16 Way 135 x 93 x 23 100 g PA0475 32 Way 270x93x23 200 g CUORE TO CELL eer mun a 16 Output Protected Termination Board PA0480 ka LOI ee i Cagna ari E da iii TENGEN HE ha noia ng te SR SR ija naja de To e Sprea FEE 32 Output Protected Termination Board PA0475 LT0185 IO NET Programmable Control System Product Overview V1 0 Unprotected Termination Boards Unprotected Termination Boards are small printed circuit boards providing direct screw terminations for 16 inputs or 16 outputs of an IO NET Controller No transient protection is provided so these boards should only be used where t
13. r supply multi dropped connection is the standard IO NET system com munications medium without special cables Data speeds are selectable from 1200 to 9600 baud RS485 modem radio and fibre optic communica tions may also be used An IO NET System consists of at least one Con troller The Controller is connected to Termination Boards using flat ribbon cable looms If connection to fire indicator panel communications is required then a RZDU to RS232 interface is also needed Features Mm 32 Inputs on each Controller E Each input common OV clean contacts end of line resistor Supervised BM Inputs in programmed mode are multi level Open Circuit Normal Alarm Short Circuit 32 Outputs on each Controller Open collector closure to OV 30 volts 100 mA max High level link compatible with Vigilant fire Some Examples of IO NET Applications Programmable Controller 32 Inputs IO NET 32 Outputs Controller Remote Mimic Panel 32 Ouputs amp IO NET Controller 4 Controller IO NET Controller Vigilant RZDU High Level Link indicator panel Remote Zone Display Unit RZDU protocol BM Supervised cable connection to Input and Output Termination Boards WH Controller operating voltage 17 5 28 volts dc WH Controller current 6 5 mA plus 0 3 mA for every open collector output turned on plus connected load E Programmed and unprogrammed modes E Readily programmed on site or off site using a personal comp
14. ut state from one other Controller This unprogrammed mode of operation is selected by a dip switch on each Controller Powerful programmable control may be achieved on each IO NET Controller by selecting the programmed mode of operation The conditions of all remote local and high level inputs in a system are available to programmable Boolean logic expressions Logic expressions may include local LT0185 IO NET Programmable Control System Product Overview V1 0 ee gra rsa pei Md per i n E er E be e CEE IO NET System Components THE Pret y tif J 151115 at Tre TUA ETA T aa Sl ea a E FE pa A J gE F r 2 dr a Ct em gt pane A DOG et re de Pl N Timer status Variables Output Status Controller and Network Status as well as local and global input status Complex functions make operations such as change of state annunciation and others possible The logic expressions and parameters for specific outputs timers and variables are stored in a nonvolatile low cost PROM on the corre sponding IO NET Controller All Controllers in a Programmed IO NET System do not need to operate in Programmed Mode Controllers operat ing in Unprogrammed Mode can be used to gather input conditions provided no outputs are used The IO NET PROM programming process is quickly accomplished either on site or off site using a personal computer and a small programming unit The PROM is inserted into the pro
15. uter and a small program ming unit E Programmable parameters stored in non volatile PROM which can be reprogrammed several times depending on program size Hm Data Transmission multidrop line driver switching 0 to 24 volts RS485 modem and fibre optic link also available E Communication cable length 3km 2400 baud 1 km 9600 baud using multidrop line driver transmission longer with mo dems WH Controller address 0 to 31 unprogrammed mode 32 Controllers 0 to 127 pro grammed mode 128 Controllers m Communication baud rates 1200 2400 4800 9600 Hm 16 amp 32 Way Protected Input Termination Boards exclude FRC Loom 16 amp 32 Way Protected Output Termination Boards exclude FRC Loom 16 Way Relay Board includes FRC Loom FRC Looms from 0 25 to 5m Optional cabinet 494W x 449H x 82D Optional gear plate pre drilled for Controller and Termination or Relay Boards Typical Applications Alarm monitoring AS 1668 Fire Fan Control Mimic display of alarms PLC with remote indication Point to point telemetry Remote annunciation Stand alone PLC CP L L L L L Point to Point Telemetry IO NET IO NET Controller Controller 32 Ouputs 32 Inputs 32 Ouputs 32 Inputs each Controller each Controller Mimic Outputs IO NET IO NET as Controller Controller required 32 per Controller Page 2 LT0185 IO NET Programmable Control System Product Overview V1 0 Fj amp Li s

Download Pdf Manuals

image

Related Search

Related Contents

Home Decorators Collection 1911110270 Use and Care Manual  大合奏!バンドブラザーズP しもべツール  be.ez LEvertigo Black Pearl  Klimax Kontrol  INSTALLATION INSTRUCTIONS  Automatic No-bark Collar  Conceptronic Portable Bluetooth Travel Stereo Speaker  Mode d`emploi - Bibliothèque Interuniversitaire de la Sorbonne  Manuale d`uso per l`utente Direct Potmachine  Mark Levinson N40 User's Manual  