User Manual - BC Group International Inc.

image

Contents

1. strong enough to carry the weight of the unit e At least 5 cm of shock absorbing material around the unit Nonabrasive dust free material for the other parts Repack the unit in a manner to ensure that it cannot shift in the box during shipment BC Biomedicals product warranty is page 8 of this manual The warranty does not cover freight charges C O D will not be accepted without authorization from BC Biomedical or its representative V CONTROL SWITCHES AND TERMINALS Front Panel Respira fon Pulse 4 500 Square 2Hz E A High Level ECG Triangle 2Hz 4 01 Sine 0 1Hz 0 P 02 60 0 5Hz RL LL 03 80 Sine 10Hz uv N mmHg 04 120BPM Sine 40Hz Base Lead 05 180BPM Sine 50Hz 80 Arterial 06 240BPM Sine 60Hz L Vent 07 300BPM Sine 100Hz B eahsMmn R Vent 08 Auto Auto ao ARES Pulm Art SSS A V e 30 PAW 31 2 BLK IT Bigeminy 32 RBBB Run of 5 PVC 33 44 VTach 34 PVC Early 45 VFIB 35 PVC Std 46 Paced 36 PVCRONT 47 Fetal Mat Amplitude mV LEAD II S ds Lead Test 51 1 0 52 1 5 53 2 0 Flashes Display 1 Power Switch Turns the power on and off 2 LCD Display Sets LCD display waveform values the right key to enter units and t
2. Frequency Band Pass Monitor Power Line Notch Filter Linearity ECG Lead Test SPECIFICATIONS 12 lead simulation derived from one resistively divided analog signal RL RA LA LL V1 6 500 or 1000 ohms to RL 1000 ohms to RL 0 5 V mV of low level Lead II 30 60 80 120 180 and 300 BPM 1 of selection 0 5mV 1 0mV 1 5mV and 2 0mV Lead 5 Lead II 1 0mV Automatic ECG Rate Test 2 0Hz 1 0 V p p biphasic 4 0sec 1 0mV 0 1 0 5 10 40 50 60 and 100 Hz 2 0 Hz 0 5mV 1 0mV 1 5mV and 2 0mV Lead II 5 Lead Il 1 0mV 4 second DC pulse 10 Hz sine point 40 Hz sine 50 Hz sine 2 Hz triangle wave Display flashes if lead resistance is 3 kOhms DC lead wire only Blood Pressure General Input Output Impedance Exciter Voltage Range Exciter Frequency Range Output Sensitivity Accuracy Calibrated Rate Dynamic Blood Pressure Selections Arterial Left Ventricle Right Ventricle Pulmonary Artery CVP Central Venous Pressure PAW Pulmonary Wedge Static Levels 300 Ohms 2 to 16 volts DC to 4000 Hz 5 or 40 uV V mmHg 1 full scale 1 mmHg 80 BPM 120 80 mmHg 20 0 mmHg 25 0 mmHg 25 10 mmHg 15 10 mmHg 10 2 mmHg 0 20 40 80 100 200 250 300 mmHg Arrhythmia Selections Atrial Fibrillation 1 amp 2 Premature Atrial Contraction Premature Ventricular Contraction PVC Early PVC Ron T PVC Multifocal PVCs Bigeminy Bigeminy Run of 5 PVCs Ventricular
3. Tachycardia Ventricular Fibrillation Second Degree Type 2 Right Bundle Branch Block Asynchronous Pacemaker Fetal Maternal ECG Respiration Normal Physiological Simulation Baseline Impedances 500 to 1000 Ohms Impedance Variations 0 1 0 2 0 5 1 0 and 3 0 Ohms Rates 0 Apnea 15 20 30 40 60 120 BPM Output Configuration Lead 1 11 RL LL Temperature 30 C 86 F 37 C 98 6 F 40 C 104 F Compatible with YSI 400 700 series Accuracy 0 25 IV RECEIPT INSPECTION RETURN 1 Inspect the outer box for damage 2 Carefully unpack all items from the box and check to see that you have the following items MaxiSim 2000 Patient Simulator e Carrying Case e MaxiSim 2000 User Manual 3 If you note physical damage or if the unit fails to function according to specification inform the supplier immediately When BC Biomedical or the company s representative is informed measures will be taken to either repair the unit or dispatch a replacement The customer will not have to wait for a claim to be investigated by the supplier The customer should place a new purchase order to ensure delivery 4 When returning an instrument to BC Biomedical or the company representative fill out the address label describe what is wrong with the instrument and provide the model and serial numbers If possible use the original packaging material for return shipping Otherwise repack the unit using e A reinforced cardboard box
4. User Manual MAXISIM 2000 Patient Simulator BC Biomedical Sv A Unit of BC Group International IV VI VI CONTENTS MANUAL REVISION RECORD INTRODUCTION 5 inr SPECIFICATIONS ehe n nie RECEIPT INSPECTION amp CONTROL SWITCHES AND TERMINALS 2 TECHNICAL SUPPORT l MANUAL REVISION RECORD This record page is for recording revisions to your MAXISIM 2000 User Manual that have been published by BC Biomedical or its authorized representatives We recommend that only the management or facility representative authorized to process changes and revisions to publications Make the pen changes or insert the revised pages e Ensure that obsolete pages are withdrawn and either disposed of immediately or marked as superseded and placed in a superseded document file and e Enter the information below reflecting that the revisions have been entered Rev No Date Entered Reason Signature of Person Entering Change Initial Release Adding CPV on Pg 4 KB 1 1 4 16 04 ll INTRODUCTION BC Biomedical s MaxiSim 2000 is a high performance simulator designed to simplify patient monitor testing and is designed to be used by trained service technicians It simulates electrocardiogram respiration dynami
5. c blood pressure and static temperature It offers three preprogrammed automatic test modes ECG rate ECG performance rate and BP level plus a built in ECG lead continuity test conduction eight ventricular one paced and one fetal maternal ECG simulation General MaxiSim 2000 Information Display Control ECG Output Connectors High Level Low level Power Case Weight Dimensions Standard Accessories Optional Accessories Arrhythmia selection includes two supraventricular two 2 digit numeric display keys 5 switches for BP respiration temperature and Power On Off Standard phone jack 10 AHA color coded standard safety banana connectors with detachable banana to snap adapter 9 V Alkaline battery or battery eliminator High impact plastic 0 5 kg 1 1 Ibs Height 47 mm 1 8 in Width 138 mm 5 4 in Length 190 mm 7 5 in MaxiSim 2000 Patient Simulator Carrying Case User Manual MaxiSim 2000 Unterminated or prewired BP Cable Unterminated or prewired 400 700 YSl series Temperature Cable 110 V or 220 V AC Adapter ECG General Lead Configuration Output Impedance Limb leads V Leads High Level Output Normal Sinus Rates Rate Accuracy Amplitudes Amplitude Accuracy Manual ECG Performance Test Square Wave DC pulse Sine Waves Triangle Wave Amplitude Amplitude Accuracy Automatic ECG Performance Test Gain Damping 2 Hz square wave Frequency Response Low
6. he left key to enter tens Press the top of the key to increase the value Press the bottom of the key to decrease the value 3 Enter Pressing this stores newly specified waveform value set by the keys 4 High Level ECG Standard phone jack connecting the high level Connector ECG output signal 5 BASE Baseline Sets the impedance between each lead The Impedance Slide respiration parameter breathing rate min is Switch selected and stored in the display 6 LEAD Slide Determines which lead is in use The position Switch of the switch must correspond to the type of patient monitor in use 7 Blood Pressure Sets the sensitivity to match the input sensitivity Slide Switch of the patient monitor either 5 or 40 UV V mmHg FV V mmHg The waveform is selected and stored in the display 8 Temperature Sets the temperature to be used Slide Switch 9 Lead Test For testing ECG leads Connect each end of Terminals the lead to one of the two Lead Test Terminals The LCD display will flash if the lead is OK 7 Rear Panel Batt elim 9v DC 6 6 W s v5 v6 v1 v2 v3 v4 6 O O 10 Low level ECG 10 AHA color coded 4mm safety Connectors terminals Snap to banana adapters for the terminals are NOTE optional with the MaxiSim 2000 Use only BC Biomedical AC Adapter plug in power 11 Battery Micro jack for connecting the 9V supply transformer Eliminator plug in power supply transformer supplied wi
7. mation e Product name and serial number e Revision level of your software e The specific steps which reproduce your problem error codes displayed on screen daytime phone number fax number and or email address if available e Your name company 10
8. medical or its local representatives be liable for direct indirect special incidental or consequential damages arising out of the use of or inability to use the MaxiSim 2000 Patient Simulator even if advised of the possibility of such damages BC Biomedical or its local representatives are not responsible for any costs loss of profits loss of data or claims by third parties due to use of or inability to use the MaxiSim 2000 Patient Simulator Neither BC Biomedical nor its local representatives will accept nor be bound by any other form of guarantee concerning the MaxiSim 2000 Patient Simulator other than this guarantee Some jurisdictions do not allow disclaimers of expressed or implied warranties in certain transactions therefore this statement may not apply to you Vil TECHNICAL SUPPORT BC Biomedicals MaxiSim 2000 Patient Simulator is backed by a superior support staff If the MaxiSim ever fails to work perfectly please contact the Technical Support Staff Written Communications You may write a letter with your comments and send it to BC Biomedical BC Group International Inc 3081 Elm Point Industrial Dr St Charles MO 63301 OR E mail sales bcgro upintl com Phone Support You can telephone the Technical Assistance Center at 314 638 3800 or 1 800 242 8428 between 8 00 AM and 4 30 PM Central Standard Time CST Monday through Friday except holidays Whichever method of contact you choose please provide the following infor
9. nal is a Lead Il waveform with 0 5V mV of low level Lead II The high level ECG connection standard phone jack is situated in the upper left hand corner of the instrument Remove the batteries and disconnect the AC Adapter if you do not intend to use the MaxSim 2000 for an extended period of time Respiration The respiration signal is transferred via ECG connections The position of the LEAD switch determines which lead is in use The position of the switch must correspond to the type of patient monitor being used The BASE baseline impedance switch sets the impedance between each lead The respiration parameter breathing rate min is selected and stored in the display Blood Pressure The sensitivity switch pVN mmHg must be set to match the input sensitivity of the patient monitor either 5 or 40 pVN mmHg The waveform is selected and stored in the display Prewired cables and diagrams for connecting various types of monitors are available from BC Biomedical Unterminated cables are also available CABLE CONNECTION MATRIX BLOOD PRESSURE CABLE DIN Plug Pin No Color Function 4 Black Output 1 Red Output 3 White Exciter 5 Green Exciter 2 Blue ECG ref Temperature See below The type of cable used determines the type of probe simulated either 400 or 700 series YSI probes Temperature is selected by a slide switch Prewired 400 700 YSl series temperature cables to connect to the
10. temperature connector are available from BC Unterminated cables are also available CABLE CONNECTION MATRIX UNIVERSAL TEMPERATURE CABLES OUTPUT 1 OUTPUT 2 DIN Plug Pin No Color 400 Series 700 Series 1 Green Tip No conn 2 Red No conn Tip 3 White No conn Ring 4 Black Barrel Barrel Lead Testing ECG leads should be tested regularly Connect each end of a lead to one of the two Lead Test terminals The display will flash if the lead is OK Rear Panel Connectors Low Level ECG Leads There are ten AHA color coded 4mm safety terminals located on the rear panel Snap to banana adapters for the terminals are optional with the MaxiSim 2000 Battery Eliminator BC Biomedical s AC Adapter plug in power supply transformer allows you to use the MaxiSim 2000 anywhere a standard electrical outlet is available To attach the AC Adapter insert the adapter s small connector into the micro jack labeled Batt Elim 9V DC onthe right rear of the unit Plug the large connector into the nearest standard electrical outlet 9 VI WARRANTY BC Biomedical warrants that the MaxiSim 2000 Patient Simulator will substantially conform to published specifications and to the documentation provided that it is used for the purpose for which it was designed BC Biomedical will for a period of twelve 12 months from date of purchase replace or repair any defective analyzer if the fault is due to a manufacturing defect In no event will BC Bio
11. th the unit for use in operating the unit from any standard electrical outlet USE 1 Power The power switch is the slide switch situated at the bottom right hand corner of the panel The instrument should be switched off when not in use to save the battery A flashing display indicates low battery power 2 Battery Replacement NOTE The battery is situated in the base of the instrument Use a 9 volt Do not use mercury alkaline battery air or carbon zinc batteries 3 Top Panel Controls and Connectors Display and Keyboard The MaxiSim 2000 has a two digit display To the left of the LCD display is a listing of available waveforms and two digit codes Access a waveform by displaying its corresponding two digit code Use the two keys below the LCD display to enter units and tens the right key is for units the left is for tens Pressing the top of the keys increases the values while pressing the bottom of the keys decreases the values The selected waveform is stored by pressing Enter Repeat the above procedure if you desire to store several waveforms By using the left hand key tens you can switch between waveforms stored in the instrument NOTE When the apparatus is switched on the display will show the When the instrument program version for a short period before switching into standard is switched off all mode stored information will be canceled Manual ECG High Level Output The high level ECG output sig