User`s Manual for JFX-2002
Contents
1. According to specific gravity of natural gas to install gas leakage alarm 1 1 Natural gas and coal gas its specific gravity is lighter than air so it suspends on the ceiling Therefore it is adviseable to locate the alarm 30cm below the ceiling at a distance about 1 5m away from gas appliance 1 2 Liquid petroleum gas its specific gravity is heavier than air so it sinks down on the bottom Therefore it is adviseable to locate the alarm 30cm above the floor at a distance of 1 meter away from a gas appliance Green Yellow Red Test Green Red Test Red Yellow Green Test 2 Required to attention 1 Do not face it to oil smoke and steam of cooking range 2 Do not install it at the airness area 3 Do not be obstructed by window curtain or cabinet 4 Do not install it at the area with heavy vapor such as washing room 3 About output wire 3 1 Red wire Positive power input This wire must be connected to a permanent 12v DC positive source Black wire Negative power input This wire must be connected to a permanent 12v DC negative source 3 2 Yellow wire Relay Common COM contact Blue wire Relay Normally open NO contact White wire Relay Normally closed NC contact The above three wires only need to be connected if you intend to trigger an external device such as a siren or monitoring system 3 3 Connect with exhaust fan Connect both blue and yellow wire with exhaust switch NO 3 OPERATION GUIDE 1 Warm up situa
2. User s Manual Gas Leakage Alarm Please read particulars before you use it NO 1 TECHNICAL PARAMTER 1 Features 1 1 Independent mode when detector used independently there is only sound and light alarm 1 2 Compatible mode it can be connected with one of the following five mode A Wired network B Wireless network C Electromagnetic valve D Wireless network and exhaust fan E Wireless network and Electromagnetic valve If you intent to choose one of the above connection you shoud pay a premium for your choice 1 3 If It is strictly compliance with quality system It can be effective to prevent fire by flammable gas such as coal gas liquid petroleum gas and natural gas carbon monoxide and monitor automatically 1 4 Widely use in house coal station colliery car and so on 2 SPECIFICATION 1 Power supply AC220V AC230V AC240V AC110V DC12V 2 Start warm up current lt 60MA 3 Working voltage 6VDC 4 Static current lt 40MA 5 Alarm current lt 150MA 6 Static consume lt 1 W 7 Alarm consume lt 3W 8 Alarm volume 290dB 9 Working environment temperature 5 C 60 C Humidity lt 97 RH 10 Alarm density Coal gas 1000 5000ppm Liquid petroleum gas 1000 5000ppm Natural gas 1000ppm 5000ppm 11 Responding time lt 30S 12 Alarm output normally open and closed signal control exhaust fan electrical magnetic valve signal CNO 2 INSTALLATION GUIDE 1 Fitting Locations
3. t weekly to proof of reliability of detector 2 Maintenance Ensure the alarm grills are always free of dust and cobwebs Disconnect power and lightly dust the grills with a soft brush Never use chemical sprays to clean the alarm enclosure Never allow water to enter the alarm enclosure Do not throw out the alarm or disassemble the alarm 3 Warranty Lingbao Electronics Co Ltd warrant to the purchaser that the product described herein is free from defects in the material or workmanship under normal use for three year from the date of purchase During the warranty period UPON PROOF OF PURCHASE we will either repair or replace the product without charge for either parts or labour The purchaser shall bear all posting and insurance costs to our company This warranty does not cover damage resulting from e Negligence of the precautions in the installation operation manual e Alterations performed by unauthorised persons e Abuse
4. tion Upon connecting power to the gas alarm the Green LED will start to flash This indicates the warm up period It will stop flashing after approximately 3 5 minutes With the Green LED constantly illuminated the gas alarm is ready to detect 2 Alarm situation Upon detecting gas the Red LED will start to flash and the siren will activate 3 Fault display When the yellow LED light flashed with the sound of buzzer it displayed the sensor have ever fault please send it to repaire If there is not yellow LED light when the sensor has fault the red and green lights flash alternately If the above condition occurs you should disconnect power to gas alarm for 1 minute and then re apply NO 4 ALARM SOLUTION When the alarm is warning solutions are needed immediately 1 Shut off wipe valve of gas 2 Open all window to let gas out of room 3 Do not touch any electrical switch plug telephone or door ring 4 Do not use match or lighter Turn off all fire immediately 5 Do not test the gas leakage with fire 6 Do not shut off the alarm power because the alarm is automatically stop to alarm once gas leakage disappeared 7 Check off the gas leakage reason and immediately notify gas supply to send professional technician to repair it NO 5 OTEHRS 1 Test Spay some inflammable gas into the detecting hole of alarm If it gives off clear pulse alarm signal that means the alarm detector is all right Suggestion do the tes
Download Pdf Manuals
Related Search
Related Contents
LG 55LB6300 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive Jensen JCR-208 User's Manual Village des Métiers, de la Formation et de l`Emploi Mode d`emploi EverFocus EN1080P23LED Life Fitness T5i User's Manual NETWORK SIGNAL PROCESSOR NSP gz-mg680 gz-mg650 gz-mg630 instructions manual de instrucciones Copyright © All rights reserved.
Failed to retrieve file