1. control a television use the provided HDMI cable to connect the TV to the CCU Use the provided Ethernet cable to connect the CCU to your home network Requires Professional Installation Install electronic door lock to the requested door Put 2 AA batteries in each of the RFID readers and attach them with 3M double sided tape to the main entry exit point of the house one on either side of the door Use the power cord to plug the CCU into a wall outlet then switch the CCU on On a computer access the Home Enhancement Suite settings at http homesuite Configure your individual settings and click the save button 10 Repeat step 6 for all other ID s desired 11 Log off the web server and enjoy your newly automated room ECE 477 Digital Systems Senior Design Project Rev 8 09 Product Use Instructions To get the most out of the Home Enhancement Suite proper customization and usage is required These steps will hopefully guide you through each step in customizing settings to your personal taste as well as the appropriate actions after a profile has been set up 1 Ensure the Central Control Unit is properly installed and powered on 2 Log on to the Home Enhancement Suite Web Interface The default address is http homesuite If the default address does not work properly attempt to configure network settings to allow DHCP If this is not possible a second solution is to create a static IP address for the device More i
2. ECE 477 Digital Systems Senior Design Project Rev 8 09 Homework 13 User Manual Team Code Name Home Enhancement Suite Group No 10 User Manual Outline Brief marketing style product description Product illustration annotated with callouts for each control display Product setup instructions Product use instructions Product troubleshooting instructions Evaluation SCORE DESCRIPTION Excellent among the best papers submitted for this assignment Very few corrections needed for version submitted in Final Report Very good all requirements aptly met Minor additions corrections needed for version submitted in Final Report Good all requirements considered and addressed Several noteworthy additions corrections needed for version submitted in Final Report Average all requirements basically met but some revisions in content should be made for the version submitted in the Final Report Marginal all requirements met at a nominal level Significant revisions in content should be made for the version submitted in the Final Report Below the passing threshold major revisions required to meet report requirements at a nominal level Revise and resubmit Resubmissions are due within one week of the date of return and will be awarded a score of 6 provided all report requirements have been met at a nominal level ECE 477 Digital Systems Senior Design Project Rev 8 09 Home E
3. al Profile screen Fig 3 you can adjust any of the settings available as well as your username and password To make the changed settings permanent click the appropriate Save button Usar Battings TestDummy s Settings Welcome to your settings page Please adjust any settings by entenng the valves and committing them by pressing the Swe button Username wil change your profile name Light Level wil set the defauit light level when your card is scanned TY Channel wil set the defaut channel on your TY when your card is scorned TY Volume wil set the defaut volume on your TY when your card is scanned User Nama TestDurnny Light Laval 0 9 B TY Channel 42 TY Volume fa Password wil change your password to enter this webpage Password password Swe Figure 3 Personal Profile Screen 6 After all the settings have been saved swipe your RFID card at the nearest reader to activate the settings 7 To manually adjust any settings without accessing the web interface just press the Save button on the CCU when your profile is the active one in the room and those settings will be saved to your profile ECE 477 Digital Systems Senior Design Project Rev 8 09 Troubleshooting Instructions The following is a list of potential problems and solutions For any problem first try unplugging the Home Enhancement Suite and plugging it back in If you are not a certified electrician do not attempt anythin
4. g listed as work for a certified electrician labeled CE Before doing any troubleshooting on the Home Enhancement Suite make sure the unit has been unplugged Problem Potential Cause Solution Power Light is off 1 Lack of power 1 Ensure power cord is undamaged and 2 Main board is damaged plugged in 2 Call manufacturer for maintenance No beeping noise when RFID is scanned No confirmation displayed on LCD 1 Batteries are dead 2 RFID connection is unstable 3 Main board is damaged la Ensure working batteries are placed in RFID readers 1b Restart device testing both readers and main board RFID readers 2 Call manufacturer for maintenance LCD does not display welcome message or username 1 LCD connection to main board unstable 2 LCD or main board is damaged 1 Unplug from wall and check that the connection is secure between the LCD and PCB CE 2 Call manufacturer for maintenance Light or TV does not turn on when RFID card is scanned Light or TV is set to a wrong setting compared to user settings 1 Port connections to main board unstable 2 Ports or main board damaged 1 Ethernet connection is unstable 2 RFID connection to main board unstable 3 RFID or main board is damaged 1 Ensure all port connections are correct on both ends 2 Restart device testing with default settings 3 Call manufacturer for maintenance 1 Make sure settings are proper
5. ly saved on the web interface 2 Restart device testing with default settings 3 Unplug from wall and check the connection between the RFID Ethernet and PCB CE 4 Call manufacturer for maintenance Light levels are adjusting inappropriately or not at all 1 Light sensor in an area incapable of correct sensing 2 Light sensor or main board is damaged 1 Make sure light sensor is not blocked from receiving correct light level of the room 2 Test by attempting maximum and minimum light levels in well lit room 3 Call manufacturer for maintenance Web Page is inaccessible 1 Ethernet connection is unstable 2 Network settings incorrect 3 Main board is damaged 1 Ensure device is properly connected to switch or computer 2 Make sure network settings are properly configured to access 3 If needed create static IP address for device 4 Call manufacturer for maintenance
6. nformation on how to do this can be found at http www portforward com 3 At the Welcome screen Fig 1 follow the link to user settings found on the left hand site of the screen User Sattings Welcome LEDs eBck co tagal Stack Version v5 41 eeeee o Build Date Apr 13 2012 00 08 00 Buttons AAAAC ad interface for the Home ze Hare You wil be able to Potentiometer 12 any settings at your leisure You can your own personal entertainment abia to enjoy your favorite lifestyle at a swipe of a card On the left you can log in to your persons settings page or edt anothers if you have the password Availeble for change ere Light Level TV Channel and TV Volume Th an option to change your usermeme and For more information on the Home Enhancement Suite Web Interface plaase fefar to the User Manual either om the Sabo Technologies Inc website or from the Manual included with your purchase Figure 1 Welcome Screen 4 At the User Settings screen Fig 2 there will be five user profiles available for customization Enter the one corresponding to your RFID card The default credentials to enter your profile page are as follows User lt the shown username gt Password password ECE 477 Digital Systems Senior Design Project Rev 8 09 User Settings Maase choose your profie and authenticate with your password Danial Allan Nathan Testoummy Figure 2 User Settings Screen 5 At your Person
7. nhancement Suite User Manual he Home Enhancement Suite is a modular home automation system It can be set up to Te a variety of household systems such as lighting home entertainment and home security The Home Enhancement Suite uses Radio Frequency Identification RFID cards to identify which user is in a given room and automatically sets the room to their preset settings Each user has the ability to set up an individualized profile or have their settings linked to a general profile Setup of the system is done via a web server and can be completed in just minutes The system includes remote doorway sensors eliminating the need for unsightly cables or expensive in wall installation These can be used to unlock a door to allow entry When a user enters the house through a locked door they simply wave their RFID card in front of the reader which can be left in your wallet without the hassle of finding the right key If the RFID card is recognized the door will open and the user can enter It s just that simple At the same time the lights are turned on to the user s preferred setting and the TV is turned on and tuned to the user s preferred channel You might like to watch the news after work or if you return later in the evening having the lights come on automatically keeps you from needing to fumble with difficult to use light switches The system keeps track of who is in a room and uses the settings of the user with the highest prio
8. rity which is set through the web interface If a user with a higher priority like a parent enters the room when a user with a lower priority like a child is already occupying the room the settings will switch automatically to the parent s settings If the higher priority user then leaves the room the settings will switch back to the user with the highest priority still in the room ECE 477 Digital Systems Senior Design Project Rev 8 09 Product Illustration Main Device Casing LCD Screen Save Button X10 Interface Chord Port HDMI Interface Chord Port Electronic Lock Chord Port ECE 477 Digital Systems Senior Design Project Rev 8 09 Product Setup Instructions In the box HDMI Cable Central Control Unit CCU Telephone Cable 4 AA Battery 2 Remote RFID Unit Lamp Control Unit Ethernet Cable X10 Sending Unit Power Cord 4 RFID Cards 1 Unpack the CCU and set it on a sturdy surface in a room with access to an Ethernet port Aw Rw 8 9 To control lighting Attach one end of the provided telephone cord to the central control unit a b Attach the remaining end of the telephone cord to the X10 Sending Unit g Plug the sending unit directly into a wall power outlet don t use surge protector Plug the room s main lamp into the Lamp Control Unit and plug that into the wall Note Lamp must be placed so that light is shed on the central control unit To

Download Pdf Manuals

image

Related Search

Related Contents

eHEF User Manual  DYNAMIC WT 9 OCT-ME-FR - Vol à voile Colmar Planeur  Hitachi CP-X201 User's Manual  User Manual for Mobile Banking VER 1.1  Proxima ASA VCC-5775P User's Manual  ¡Atención!    KBX-11  

Copyright © All rights reserved.
Failed to retrieve file