1. INSTALLER S NAME OE INSTALLER S ADDRESS OE NOTE WARRANTY SERVICE MUST PERFORMED BY AN AUTHORIZED SERVICE AGENT YOU MAY REQUEST WARRANTY SERVICE BY CALLING 800 449 8691 YOU MAY ALSO REQUEST SER VICE VIA THE INTERNET BY SUBMITTING THE SERVICE REQUEST FORM WWW BLUESTARCOOKING COM In the Commonwealth of Massachusetts gas connections must be performed by a licensed plumber or licensed gas fitter P N 750306 Page 6 HANDLING REMOVE ALL WATCHES BELT BUCKLES JEWELRY RINGS AND ANY CLOTHING WITH METAL BUTTONS OR SNAPS TO PREVENT DAMAGE TO THE HOOD WHEN YOU BEGIN THE INSTALLATION PROCESS REMOVE THE HOOD FROM IT S ORIGI NAL CARTON AND PLACE THE HOOD ON A CLEAN NON ABRASIVE BLANKET INSPECT THE HOOD CAREFULLY FOR ANY DAMAGE OR IMPERFECTIONS BEFORE YOU BEGIN TO INSTALL THE HOOD IF ANY DAMAGE OR IMPERFECTIONS EXIST RECARTON THE HOOD AND CALL YOUR DEALER IMMEDIATELY DO NOT INSTALL A DAMAGED HOOD IT IS HIGHLY RECOMMENDED THAT RUBBER GLOVES BE USED TO PREVENT SCRATCHES ON THE HOOD AND TO PROVIDE YOU WITH A FIRM GRIP WHEN REMOVING THE HOOD FROM THE CARTON LOCATE THE FILTERS THE FILTERS ARE PACKED SEPARATELY DO NOT REMOVE HOOD FROM ORIGINAL CARTON UNTIL YOU ARE READY TO IN STALL UNPACKING CHECK THE PACKAGE FOR DAMAGE IF ANY DAMAGE IS VISIBLE YOU SHOULD MARK THE BILL OF LADING YOU SIGN THAT THERE MAY BE CONCEALED DAMAGE e INSURE THE CONTAINER IS UPRIGHT IF THE CONTAINER
2. Duct cover sold packed in separate box 2 of 2 PC60240 PC66240 24 Depth No blower Sold and Packaged Separately Six 6 Stainless Steel Baffle Filters Three 3 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram Duct cover sold packed in separate box 2 of 2 P N 750306Page 9 DIMENSIONS OF THE PRO LINE SERIES HOOD wz Low e INLET LOCATION FOR THE ELECTRICAL CONNECTION IS LOCATED NEAR THE REAR CENTER OF HOOD 2 5 FROM HOOD BOTTOM ELECTRICAL REQUIREMENTS 15 AMPS AT 120 VOLTS LIGHT BULBS ARE PAR 16 60 WATT HALOGEN BULBS ARE OPERATED BY A DIMMER SWITCH BLOWER IS VARIABLE SPEED AND MUST BE PURCHASED SEPERATELY Center Line Electrical Connection Cut out to fit L Bracket for specific Blower Application P N 750306 Page 10 SITE PREPARATION FOR PRO LINE SERIES IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING A HEIGHT OF 30 MINIMUM HEIGHT OFF OF COOKING SURFACE TO 36 MAXIMUM HEIGHT OFF OF THE COOKING SURFACE WILL SUIT MOST USERS IF MOUNTED AT A HEIGHT GREATER THAN 36 ABOVE THE COOKING SURFACE THE HOOD SHOULD BE AT LEAST 6 WIDER THAN THE COOKING APPLIANCE TO PROVIDE A PROPER CAPTURE OF HEAT AND GREASE REFER TO THE RANGE MANUFACTURER S GUIDELINES ONCE THE PROPER HEIGHT IS ESTABLISHED DRAW A LEVEL LINE WHERE THE BOTTOM OF THE H
3. 6 4 Fan2 5 3 P N 750306 Page 14 For remote fan use connection for Fan 1 INSTALLATION GUIDE FOR PRO LINE DUCT COVER REMOVE POP RIVETS FROM PRO HOOD THAT CORRESPOND WITH THE SMALL HOLES ON THE DUCT COVER INSTALL HOOD TO CORRECT HEIGHT BE CAREFUL TO LEAVE 12 FOR DUCT COVER SLIDE DUCT COVER OVER TOP OF HOOD MAKE SURE SMALL HOLES IN DUCT COVER FLANGE LINE UP WITH HOLES IN HOOD WHERE RIVETS WERE REMOVED FROM INSIDE HOOD ATTACH DUCT COVER TO HOOD USING SHEETMETAL SCREWS OPTIONAL ATTACHMENT y HOLES SMALL HOLES USED FOR FASTENING LARGE HOLE FITS OVER Ev EXISTING RIVET IN REMOVE RIVETS THAT HOLES IN DUCT COVER a 750306 15 DIMENSIONS OF THE PYRAMID STYLE SERIES HOOD P N 750306 Page 16 SITE PREPARATION FOR PYRAMID STYLE SERIES IN SELECTING THE PROPER HEIGHT TO MOUNT THE HOOD TAKE INTO CONSIDERATION THE STATURE OF THE PERSON OR PERSONS WHO WILL BE COOKING A HEIGHT OF 30 MINIMUM HEIGHT OFF OF COOKING SURFACE TO 36 MAXIMUM HEIGHT OFF OF THE COOKING SURFACE WILL SUIT MOST USERS IF MOUNTED AT A HEIGHT GREATER THAN 36 ABOVE THE COOKING SURFACE THE HOOD SHOULD BE AT LEAST 6 WIDER THAN THE COOKING APPLIANCE TO PROVIDE A PROPER CAPTURE OF HEAT AND GREASE REFER TO THE RANGE MANUFACTURER S GUIDELINES ONCE THE PRO
4. AIR DUCT MUST VENT OUT OMMENDED YOU PURCHASE A MULTI DOORS PURPOSE DRY CHEMICAL OR FOAM TYPE FIRE EXTINGUISHER FOR YOUR HOME STORE IT IN CLOSE PROXIMITY TO YOUR APPLIANCES P N 750306Page 3 WARNING TO REDUCE THE RISK OF A RANGETOP GREASE FIRE CONTINUED 9 IF YOU ARE FLAMING LIQUOR OR OTHER SPIRITS AND YOUR APPLIANCE IS INSTALLED UNDER A VENT HOOD TURN THE FAN OFF THE DRAFT CREATED COULD CAUSE THE FLAMES TO SPREAD OUT OF CONTROL FOR YOUR SAFETY NEVER USE YOUR APPLIANCE OR ANY OTHER COOKING APPLIANCE AS A SPACE HEATER TO WARM OR HEAT THE ROOM USE ONLY DRY POTHOLDERS MOIST OR DAMP POTHOLDERS ON HOT SURFACES MAY RESULT IN STEAM BURNS DO NOT ALLOW POTHOLDERS TO TOUCH HOT BURNER AREAS DO NOT USE A TOWEL OR OTHER BULKY MATERIAL AS A POTHOLDER TO REDUCE THE RISK OF BURNS IGNITION OF FLAMMABLE MATERIALS AND SPILLAGE THE HANDLE OF ANY POT OR PAN SHOULD BE POSITIONED SO THAT IT DOES NOT EXTEND OVER ADJACENT BURNERS OR THE FRONT OF THE APPLIANCE CLEAN VENTILATING FANS AND GREASE BAFFLES OFTEN GREASE SHOULD NOT BE ALLOWED TO ACCUMULATE WARNING TO REDUCE RISK OF INJURY TO PERSONS DUE TO A GREASE FIRE SMOTHER THE FLAMES WITH A CLOSE FITTING LID COOKIE SHEET OR METAL TRAY THEN TURN OFF THE BURNER TAKE CARE TO AVOID AND PREVENT BURNS IF FLAMES DO NOT EX TINGUISH EVACUATE THE PRMISES AND CALL THE FIRE DEPARTMENT NEVER HANDLE OR PICK UP A FLAMING PAN DO NOT USE WATER INCLUDING WET DISHCLOTHS OR TOWELS A VIOLEN
5. DIMENSIONS PROVIDE FOR SAFE AND EFFICIENT OPERATION OF THE HOOD IF FOR SOME REASON THE HOOD IS MOUNTED GREATER THAN 72 FROM THE FLOOR IT MUST BE 6 WIDER THAN THE RANGE ALL PC MODELS TOP DUCT ONLY NOTE THE PC HOOD CAN BE DUCTED TO THE REAR WITH THE USE OF A 90 DGREE ELBOW NOT INCLUDED CHECK MANUAL FOR RECOMMENDED TRANSITIONS REAR DISCHARGE TOP DISCHARGE P N 750306 Page 18 PYRAMID STYLE DUCT INFORMATION BS PC3624 BS IBPC600 BS PC3624 BS IBPC1200 TR6X15 10 BS PC4224 BS IBPC600 BS PC4224 BS IBPC1200 TR6X15 10 BS PC4824 BS IBPC1200 TR6X15 10 BS PC5424 5 200 6 15 10 BS PC6024 5 200 6 15 10 BS PC6624 5 200 6 15 10 BS IBPC600 IS SIZED FOR A 6 DUCT TRC8 6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT SIZE TO 8 FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION PROPER INSTALLATION OF DUCTING IS EXTREMELY IMPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM e ALL CFM S ARE BASED ON TESTS AT 0 1 STATIC PRESSURE WITHOUT STATICE PRESSURE ALL CFM S WOULD BE OVERSATED 9 SIRAIGHT RUNS OR GRADUAL TURNS ARE BEST e NEVER USE FLEXIBLE DUCT WORK 9 PROPER PERFORMANCE IS DEPENDENT ON PROPER DUCT INSTALLATION USE QUALIFIED AND TRAINED INSTALLER 9 CONSULT WITH LOCAL CODES FOR MAKE UP AIR REQUIREMENTS P N 750306Page 19 INSTALLATION OF YOUR PYRAMID STYLE BLOWER IN
6. description of the claimed defect and proof of purchase of the Product including the original retail receipt or invoice to establish the Warranty Period Prizer Painter must also be given an opportunity to inspect any defective Product warranty repairs must be performed by a factory authorized service agent Service will be provided during normal business hours The purchaser will be responsible for any labor performed at overtime or premium rates The purchaser 15 also responsible for making the Product accessible for service P N 750306Page 25 PERFORMANCE CHECKLIST This checklist has been developed to assure proper installation of your appliance To validate your warranty you must mail or fax this form and a copy of your receipt to Warranty Department Prizer Painter 600 Arlington Street Reading PA 19611 Fax 610 376 2596 Customer Information Please Print Product Information Please Print Name Model No Address Serial No City Purchase Date State Zip Code Installation Date e mail Installer s Name Telephone Company CHECK ALL THAT APPLY Dealer Telephone Unpacking Packaging Condition GOOD O BAD Baffles Included YES NO Flue optional on some units YES NO Owner Manual Included YES NO User Manual Included YES NO Appearance and Aesthetics Exterior clean and scratch free YES NO Interior clean YES NO Installation Read User Man
7. 750306 Page 20 For remote fan use connection for Fan 1 INSTALLATION GUIDE FOR FLUE PYRAMID STYLE HOOD 1 MEASURE FROM TOP OF THE CANOPY TO CEILING AND SUBTRACT 1 8 FOR CLEAR ANCE 2 PLACE THE DUCT COVER TOP INSIDE THE DUCT COVER BASE AND LOWER UNTIL DE SIRED HEIGHT IS FOUND TO ELIMINATE SCRATCHES MAKE A MARK ON THE DUCT COVER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15 FROM THE TO TAL HEIGHT NEEDED 3 USE THE RETAINING SCREWS TO FASTEN IN PLACE 4 SLIDE THE DUCT COVER IN PLACE AND FASTEN FROM INSIDE CANOPY USING SHEET METAL SCREWS NOTE FOR INSTALLATIONS WITH CEILINGS ABOVE 9 USE OPTIONAL CUSTOM FLUES SEE PRODUCT LITERATURE FOR DETAILS Item 4 MODEL A DIM B MAXIMUM C DIM BS PC3024 15 27 12 Item 2 BS PC3624 15 21 12 BS PC4224 13 277 15 5 4824 13 277 18 Duct Cover BS PC5424 15 27 24 BS PC6024 5 2T gt BS PC6024 5 PA 24 12 30 5 cm P N 750306Page 21 WIRE DIAGRAM FOR BLUESTAR PL AND PC HOODS Connection to Terminal Block Ground HARNESS PREWIRED 115 Volt from Panel Fan 1 6 4 Fan2 5 3 For remote fan use connection for Fan 1 P N 750306 Page 22 CLEANING AND MAINTENANCE YOUR HOOD MUST BE KEPT CLEAN AND MAINTAINED PROPERLY BAFFLE FILTERS e BAFFLE FILTERS SHOULD BE EXAMINED PERIODICALLY TO ASSURE THAT ALL SUR FACES AND PARTS ARE
8. CLEAN e THE FILTERS ARE DISHWASHER SAFE OR IN A SINK WITH HOT SOAPY WATER EASY PERIODIC CLEANING WILL ASSURE OPTIMUM FILTER PERFORMANCE e DO NOT USE CAUSTIC DETERGENT TO CLEAN THE FILTERS ABRASIVE CLEANERS MAY HARM OR DAMAGE THE FINISH DO NOT DISASSEMBLE THE BAFFLE FILTER DISASSEMBLY WILL VOID THE WAR RANTY CANOPY e DONOT USE ABRASIVE CLEANERS STEEL WOOL PADS ABRASIVE CLOTHS OR CLEAN ERS WITH CHLORIDES DO ALLOW GREASE TO ACCUMULATE FOR BEST RESULTS WIPE THE CANOPY DOWN WITH A SOFT CLOTH AND HOT SOAPY WATER THE CLEANING OF THE OUTSIDE OF THE HOOD DEPENDS ON THE MATERIAL USED AS A DECORATIVE EXTERIOR FOR STAINLESS STEEL AND POWDER COATED METALS CLEAN WITH SOAP AND WATER ONLY DO NOT USE ABRASIVE OR AGGRESSIVE CHEMICALS REPLACING THE LIGHT BULBS e UNSCREW HALOGEN LIGHT BULB e REPLACE HALOGEN WITH 60 WATT 115 VOLT HALOGEN PAR 16 LIGHT BULB P N 750306Page 23 WARRANTY WHAT IS COVERED Prizer Painter provides the following limited warranties to the original retail purchasers of Products sold and installed in the continental United States and Canada on or after February 22 2002 Initial Seven 7 Day Limited Warranty Prizer Painter warrants that all cosmetic components of its products will under normal use and service be free from defects in materials and workmanship for a pe riod of seven 7 calendar days from the date of delivery the Warranty Period to the original retail pur chaser For
9. E OF CONTENTS Table NR 2 3 4 YORI l i uu un un m 5 o s a ha om TREE 6 S 1101 99 1 10 1 2 9 21 229 2 2919 9 19 2229 9 22 22 9 222292919 21 292 22229 9222229 9 209 I Packing list for your Vent Hood 8 9 AE J a gsc gt x xu 8 IE 9 Installation of Pro Line Series DimensionS 2 2 4 411 5 4 4 6 10 Sl Ti Y AON 11 EGC OPC OL RC O I MNT T MS 12 Doct llonni u u u uu u u luas uu 13 Blower Installation 14 Custom Duct Installation 15 Installation of Pyramid Style Dimensions uuu u u A 16 DIC ie Br AU ONE 17 The 5 Ilo Db 18 Duct 1111111111 99996 a 19 Blower Installation e ne
10. EF Genuine Restaurant Ranges for the Home INSTALLATION USE AND CARE MANUAL FOR PROFESSIONAL VENTILLATION FOR THE HOME IMPORTANT PLEASE READ AND FOLLOW THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION HOWEVER WE RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA TION DO NOT REMOVE PERMANANTLY AFFIXED LABELS WARNINGS OR DATA PLATES FROM YOUR APPLIANCE THIS MAY VOID THE MANUFACTURER S WARRANTY AND OR HINDER EFFECTIVE SERVICING AND MAINTENANCE THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE AND THE CONSUMER IS TO RE TAIN THEM FOR FUTURE REFERENCE PLEASE OBSERVE ALL LOCAL AND NATIONAL BUILDING CODES AND ORDINANCES IF NO LO CAL CODES ARE APPLICABLE PLEASE FOLLOW ALL WIRING REQUIREMENTS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 EDITION PLEASE CHECK WITH A QUALIFIED AND TRAINED INSTALLER OR YOUR LOCAL CODES FOR ANY MAKE UP AIR REQUIREMENTS THIS HOOD IS FOR RESIDENTIAL USE ONLY AND IS NOT DESIGNED FOR INSTALLATION OVER A COMMERCIAL PRODUCT MAKE SURE ALL POWER IS TURNED OFF AT THE MAIN BREAKER OR FUSE BOX BEFORE MAKING ANY CONNECTIONS TO AVOID RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS TURN OFF THE ELECTRIC ITY TO THE HOOD FROM THE POWER SUPPLY BEFORE CLEANING OR SERVICING This product is intended for domestic use only NTERTE W LISTED Copyright 2007 Prizer Painter Stoves Works P N 750306Page 1 TABL
11. IS NOT UPRIGHT MAJOR DAM AGE CAN OCCUR TO YOUR APPLIANCE IF DAMAGE IS DISCOVERED DO NOT REFUSE DELIVERY CONTACT THE DEALER AND FILE APPROPRIATE FREIGHT CLAIMS SAVE ALL PACKAGING MATERIAL DO NOT CONTACT THE MANUFACTURER YOUR APPLI ANCE WAS SHIPPED FROM THE DEALER YOU PURCHASED IT FROM SHIPPING DAMAGE CLAIMS ARE TO BE RESOLVED BETWEEN THE CUSTOMER SHIPPING CARRIER AND DEALER THE MANUFACTURER MAY ASSIST IN RESOLVING ANY SUCH CLAIMS BUT SUCH ASSISTANCE DOES NOT RELIEVE YOU OF YOUR RESPONSIBILITY e MOVE THE CONTAINER AS CLOSE TO ITS INSTALLATION LOCATION AS POSSIBLE THIS WILL REDUCE MOVING AND HANDLING YOUR APPLIANCE ONCE IT IS OUT OF ITS SHIP PING CONTAINER DO NOT DISCARD PACKAGING WITHOUT FIRST LOCATING THE FILTERS e INSPECT ALL MOLDED PACKAGING BEFORE DISCARDING ANY DAMAGE MUST BE REPORTED BEFORE INSTALLING THE HOOD ONCE THE HOOD HAS BEEN INSTALLED NO RETURN WILL BE AC CEPTED MAKE SURE BLOWERS ARE FREE FROM OBSTRUCTIONS PACKING AND DEBRIS TEST RUN BLOWERS BEFORE FINALIZING INSTALLATION CHECK WITH MANUFACTURER BE FORE ATTEMPTING TO USE OTHER THAN BLUESTAR BLOWER SYSTEMS FOR TECHNI CAL INFORMATION CONTACT BLUESTAR SERVICE 610 376 7479 P N 750306Page 7 PACKING LIST FOR PRO LINE HOOD SERIES PL30240 24 depth No blower Sold and Packaged Separately Two 2 Stainless Steel Baffle Filters Two 2 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wi
12. N P N 750306Page 13 INSTALLATION OF YOUR PRO LINE SERIES BLOWER INSTALLATION OF BS IBPL600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM REMOVE SHIPPING BRACKET SEE ITEM 1 FROM HOOD DO NOT DISCARD SCREWS INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET LOCATE THE TERMINAL BLOCK INSIDE THE ELECTRICAL SUPPLY BOX CONNECT FAN 1 WIRE TO TERMINAL BLOCK 74 CONNECT FAN 1 WIRE TO TERMINAL BLOCK 6 CONNECT THE 115 VOLT WHITE SUPPLY WIRE TO TERMINAL BLOCK 72 CONNECT THE 115 VOLT BLACK SUPPLY WIRE TO TERMINAL BLOCK 71 INSTALLATION OF BS IBPL1200 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM REMOVE SHIPPING BRACKET FROM HOOD DO NOT DISCARD SCREWS FOR FAN 1 INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET LOCATE THE TERMINAL BLOCK INSIDE THE ELECTRICAL SUPPLY BOX CONNECT FAN 1 WIRE TO TERMINAL BLOCK 4 CONNECT FAN 1 WIRE TO TERMINAL BLOCK 6 CONNECT THE 115 VOLT WHITE SUPPLY WIRE TO TERMINAL BLOCK 72 CONNECT THE 115 VOLT BLACK SUPPLY WIRE TO TERMINAL BLOCK 71 FOR FAN 2 CONNECT FAN 2 WIRE TO TERMINAL BLOCK 73 1 CONNECT FAN 2 WIRE TO TERMINAL BLOCK 75 Item 1 shipping bracket should be used with remote blower as the attachment for the flue Once removed attach blower as described above Shipping bracket Blower motor bracket Connection to Terminal Block x Ground HARNESS PREWIRED 115 Volt from Panel Fan 1
13. OOD WILL REST IF PRACTICAL MOUNT A BOARD EQUAL TO THE WIDTH OF THE HOOD ALONG THE LINE SO YOU MAY REST THE HOOD ON IT WHILE INSTALLING MARK A CENTER LINE ON THE WALL EQUAL TO THE ENTIRE HEIGHT OF THE HOOD TO ASSIST WITH THE PROPER DUCT ALIGNMENT AND HOOD PLACEMENT DETERMINE STUD LOCATION AND MARK IT CLEARLY BECAUSE OF THE WEIGHT OF THE HOOD MAKE SURE THAT THE MOUNTING SCREWS ARE DRIVEN INTO THE STUD AND NOT JUST THE DRYWALL IT MAY BE NECES SARY TO DRILL ADDITIONAL HOLES INTO THE CANOPY FOR PROPER ALIGNMENT IF ONLY ONE STUD CAN BE LOCATED TOGGLE BOLTS OR ADDITIONAL FASTENING MUST BE INSTALLED TO FIRMLY SECURE THE TO THE WALL INSTALL A 115 VOLT 15 AMP ELECTRICAL LEAD IN THE HOLE MARKED ON THE ROUGH IN DIAGRAM FIG A EXAMPLE LOCATION FOR A 36 HOOD IS 2 5 FROM THE BOTTOM CENTERED ON THE HOOD VERIFY THAT THE DUCTING IS IN THE CORRECT LOCATION FOR YOUR APPLICA TION Center Line Electrical Connection Cut out to fit L Bracket for specific Blower Application FIGURE A P N 750306Page 11 THE CORRECT HEIGHT OF YOUR PRO LINE SERIES HOOD 20 76 2 cm Min 36 21 4 cm Max 66 F 167 6cm 182 9 cm THE BOTTOM OF THE HOOD SHOULD BE 30 MINIMUM TO 36 MAXIMUM ABOVE THE COUNTERTOP THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66 TO 72 ABOVE THE FLOOR THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72 ABOVE THE FLOOR OR MORE THAN 36 ABOVE THE COUNTE
14. PER HEIGHT IS ESTABLISHED DRAW A LEVEL LINE WHERE THE BOTTOM OF THE HOOD WILL REST IF PRACTICAL MOUNT A BOARD EQUAL TO THE WIDTH OF THE HOOD ALONG THE LINE SO YOU MAY REST THE HOOD ON IT WHILE INSTALLING MARK A CENTER LINE ON THE WALL EQUAL TO THE ENTIRE HEIGHT OF THE HOOD TO ASSIST WITH THE PROPER DUCT ALIGNMENT AND HOOD PLACEMENT DETERMINE STUD LOCATION AND MARK IT CLEARLY BECAUSE OF THE WEIGHT OF THE HOOD MAKE SURE THAT THE MOUNTING SCREWS ARE DRIVEN INTO THE STUD AND NOT JUST THE DRYWALL IT MAY BE NECES SARY TO DRILL ADDITIONAL HOLES INTO THE CANOPY FOR PROPER ALIGNMENT IF ONLY ONE STUD CAN BE LOCATED TOGGLE BOLTS OR ADDITIONAL FASTENING MUST BE INSTALLED TO FIRMLY SECURE THE HOOD TO THE WALL INSTALL A 115 VOLT 15 AMP ELECTRICAL LEAD IN THE HOLE MARKED ON THE ROUGH IN DIAGRAM FIG A EXAMPLE LOCATION FOR A 36 HOOD IS 2 5 FROM THE BOTTOM 18 FROM THE CENTER LINE VERIFY THAT THE DUCTING IS IN THE CORRECT LOCATION FOR YOUR APPLICA TION 2 1 2 Electrical Connection FIGURE A P N 750306Page 17 THE CORRECT HEIGHT OF YOUR PYRAMID STYLE HOOD 30 76 2 cm Min 36 91 4 cm Max 66 72 167 Gcm 182 9 cm THE BOTTOM OF THE HOOD SHOULD BE 30 MINIMUM TO 36 MAXIMUM ABOVE THE COUNTERTOP THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66 TO 72 ABOVE THE FLOOR THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 72 ABOVE THE FLOOR OR MORE THAN 36 ABOVE THE COUNTERTOP THESE
15. R MAKING ANY CONNECTIONS WARNING WARNING TO REDUCE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOW ING INSTALLATION WORK AND ELECTRICAL BY THE MANUFACTURER IF YOU HAVE WORK MUST BE PERFORMED BY QUALIFIED ANY QUESTIONS PLEASE CALL 610 374 7679 INDIVIDUALS IN ACCORDANCE WITH ALL BEFORE CLEANING OR SERVICING UNIT APPLICABLE CODES AND STANDARDS IN SWITCH POWER OFF TO THE UNIT AT THE CLUDING ALL FIRE RATED CONSTRUCTION SERVICE PANEL AND LOCK OUT THE SER DONOT DAMAGE ANY EXISTING ELECTRI VICE PANEL IF THE SERVICE PANEL CAN CAL OR HIDDEN UTILITIES WHEN DRILL NOT BE LOCKED OUT PLEASE AFIX A ING CUTTING AND OR REMOVING A WALL WARNING DEVICE PROMINENTLY SUCH AS TAG TO THE SERVICE PANEL DUCTED FANS MUST VENT OUTDOORS SUFFICIENT AIR IS REQUIRED TO PROPERLY WARNING EXHAUST GASES THROUGH THE FLUE OF PICAN YY NATURAL AND LIQUID PROPANE FUELED COOKING EQUIPMENT TO AVOID ANY BACK USE THIS UNIT IN THE MANNER INTENDED TO REDUCE THE RISK OF RANGETOP GREASE DRAFTING FOLLOW ALL LOCAL AND NA FIRE TIONAL CODES AND STANDARDS FOR NEVER LEAVE THE APPLIANCE UNAT PROPER AIR REQUIREMENTS TENDED DURING USE BOIL OVERS MAY e USE ONLY METAL DUCTWORK OCCUR CAUSING SPILLS WHICH MAY IG NEVER VENT DUCTED EXHAUST AIR INTO NITE ANOTHER ROOM OR GARAGE TO REDUCE DO NOT USE WATER ON GREASE FIRES THE RISK OF FIRE AND TO PROPERLY VENT NEVER PICK UP A FLAMING PAN IT IS REC EXHAUST
16. RTOP THESE DIMENSIONS PROVIDE FOR SAFE AND EFFICIENT OPERATION OF THE HOOD IF FOR SOME REASON THE HOOD IS MOUNTED GREATER THAN 72 FROM THE FLOOR IT MUST BE 6 WIDER THAN THE RANGE ALL PL MODEL HOODS HAVE THE FLEXIBILITY TO EITHER DUCT FROM THE TOP OR REAR CHECK MANUAL FOR RECOMMENDED TRANSITIONS 10 TOP DISCHARGE REAR DISCHARGE P N 750306 Page 12 PRO LINE DUCT INFORMATION T TT BS PL3024 BS IBPL600 6 BS PL3624 BS PL3624 BS IBPL1200 TR6X15 10 BS PL4224 BS IBPL600 BS PL4224 TR6X15 10 BS PL4824 TR6X15 10 BS PL5424 TR6X15 10 BS PL6024 TR6X15 10 BS PL6624 BS IBPL1200 TR6X15 10 BS IBPL600 IS SIZED FOR A 6 DUCT TRC8 6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT SIZE TO 8 FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION PROPER INSTALLATION OF DUCTING IS EXTREMELY IMPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM e ALL CFM S ARE BASED ON TESTS AT 0 1 STATIC PRESSURE WITHOUT STATIC PRESSURE ALL CFM S WOULD BE OVERSTATED e STRAIGHT RUNS OR GRADUAL TURNS ARE BEST e NEVER USE FLEXIBLE DUCT WORK e PROPER PERFORMANCE IS DEPENDENT ON PROPER DUCT INSTALLATION USE A QUALIFIED AND TRAINED INSTALLER e CONSULT WITH LOCAL CODES FOR MAKE UP AIR REQUIREMENTS L BRACKETS FOR THE INTERNAL BLOWER PACKAGES CAN BE MOUNTED FOR EITHER TOP OR REAR DISHARGE BS IBPLI200 BLOWERS REQUIRE AN ADDITIONAL PURCHASE OF A 10 TRANSITIO
17. STALLATION OF BS IBPC600 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM REMOVE SHIPPING BRACKET SEE ITEM 1 FROM HOOD DO NOT DISCARD SCREWS INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET LOCATE THE TERMINAL BLOCK INSIDE THE ELECTRICAL SUPPLY BOX CONNECT FAN 1 WIRE TO TERMINAL BLOCK 4 CONNECT FAN 1 WIRE TO TERMINAL BLOCK 6 CONNECT THE 115 VOLT WHITE SUPPLY WIRE TO TERMINAL BLOCK 72 CONNECT THE 115 VOLT BLACK SUPPLY WIRE TO TERMINAL BLOCK 1 INSTALLATION OF IBS IBPCI200 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM SUN amus REMOVE SHIPPING BRACKET FROM HOOD DO NOT DISCARD SCREWS 36 HOOD W 1200 CFM THE STIFFENER MUST ALSO BE REMOVED FOR FAN 71 1 INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE SHIPPING BRACKET LOCATE THE TERMINAL BLOCK INSIDE THE ELECTRICAL SUPPLY BOX CONNECT FAN 1 WIRE TO TERMINAL BLOCK 4 CONNECT FAN 1 WIRE TO TERMINAL BLOCK 6 CONNECT THE 115 VOLT WHITE SUPPLY WIRE TO TERMINAL BLOCK 72 CONNECT THE 115 VOLT BLACK SUPPLY WIRE TO TERMINAL BLOCK 1 FOR FAN 2 CONNECT FAN 2 WIRE TO TERMINAL BLOCK 73 2 CONNECT FAN 2 WIRE TO TERMINAL BLOCK 75 Item 1 shipping bracket should be used with remote blower as the attachment for the flue Once removed attach blower as described above x Ground WHITE HARNESS PREWIRED 115 Volt from Panel Fan 1 6 4 Fan2 5 3 P N
18. T STEAM EXPLO SION MAY ENSUE DO NOT TURN ON HOOD TO EVACUATE SMOKE TURN OFF HOOD USE AN EXTINGUISHER ONLY IF YOU HAVE A CLASS ABC EXTINGUISHER AND YOU CAN OPERATE IT THE FIRE IS SMALL AND CONTAINED WHERE IT STARTED THE FIRE DEPARTMENT HAS BEEN NOTIFIED YOU CAN FIGHT THE FIRE WITH YOUR BACK TOWARDS AN UNOBSTRUCTED EXIT WARNING THIS PRODUCT IS FOR GENERAL VENTILATION APPLICATIONS DO NOT USE TO EXHAUST HAZ ARDOUS FLAMMABLE OR EXPLOSIVE MATERIALS PRIOR TO CLEANING OR SERVICING THE UNIT SWITCH POWER OFF AT THE SERVICE PANEL AND LOCK OUT THE PANEL IF THE PANEL CANNOT BE LOCKED OUT AFFIX A PROMINENT WARNING TAG TO THE SERVICE PANEL DO NOT USE PORCELAIN OR ABRASIVE CLEANERS ON THIS PRODUCT THIS MAY RESULT IN COSMETIC DAMAGE TO THE SURFACE LIKE SCRATCHES AND OR DISCOLORIZATION ALL BRASS TRIM PIECES REQUIRE SPECIAL CLEANING DO NOT USE ABRASIVE CLEANERS OR FURNITURE POLISH THIS WILL RESULT IN DISCOLORIZATION TO THE BRASS SURFACE P N 750306 Page 4 DLUESTRR The Only Genuine Restaurant Range for the Home Since 1880 we have been dedicated to quality We believe that our success can only be measured by the continuing success of our customers We achieve customer satisfaction by ensuring that each of our employees understands meets and exceeds customer expectations We establish and maintain an environment that encourages all employees to pursue continuous improvement in qual ity and productivity Our quality policy 1s monito
19. duct damage from natural disasters fires floods earthquakes or other acts of God loss of electrical power to the Product for any rea son alteration for outdoor use damage due to the use of harsh chemicals e g cleaning products improp erly applied or any other circumstances beyond Prizer Painter s control This Limited Warranty is also invalid if the original factory installed serial number has been altered or removed from the Product The Purchaser 15 responsible for proper installation and normal care and maintenance of the Product This warranty gives you specific legal rights and you may also have other rights which vary from State to State OBTAINING WARRANTY SERVICE warranty claims must be reported to Prizer Painter Stove Works Inc 600 Arlington St Reading Pennsylvania 19611 prior to the expiration of the applicable Warranty Period If a warranty claim relates to cosmetic parts any such claim must be reported to Prizer Painter within seven 7 calendar days after the Product has been delivered The purchaser must call the factory at the toll free 1 800 449 8691 to re port a warranty claim or to obtain information about warranty service If any warranty claim 1s not submit ted as required by this Limited Warranty any such claim will be invalid and will not be honored At the time the warranty claim 15 made the purchaser must provide the model number of the Product the serial number of the Product proof of delivery a
20. esponsible for the cost of additional mileage non standard service and special equipment to remove the Product for service so that there is accessibility on all sides of the Product The repair or replacement of the Product or the return of the purchase price will be the purchaser s sole and exclusive remedy for any breach of this Limited Warranty or any other claim with respect to the Product including those claims based on contract warranty or tort In no event will Prizer Painter s liability for any defective Product exceed the purchase price thereof This exclusive remedy will not be deemed to have failed of its essential purpose so long as Prizer Painter is willing and able to repair and or replace de fective Products in the manner prescribed herein or to provide a refund if in Prizer Painter s sole judgment repair or replacement 15 not feasible or appropriate under the circumstances WARRANTY WHAT IS NOT COVERED This Limited Warranty 1s the sole and exclusive warranty provided for the Product and extends only to original retail purchasers in the continental United States and Canada This Limited Warranty is not trans ferable to any subsequent purchasers or users If any implied warranties arise under any applicable law including but not limited to implied warranties of merchantability and fitness for particular purpose then the duration of those implied warranties will last only as long as the express warranties stated above Prizer Pa
21. inter will not under any circumstances be liable for any special indirect incidental or con sequential damages of any kind including but not limited to loss of business or profits loss of use or installation or removal costs Nor will Prizer Painter be responsible for any shipping costs related to the repair or replacement of any Product under this Limited Warranty Some States do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long implied warranties last so the above limitations may not apply to you This Limited Warranty does not apply to commercial usage or to any Products installed in any non residential settings such as day cares bed and breakfasts hotels nursing homes churches etc This Lim ited Warranty also does not cover and specifically excludes chipping porcelain calibrations and normal adjustments after installation and setup burner adjustments normal care and maintenance cleaning of parts shipping damage discoloration of the griddle rust gasket materials ceramic materials and fuses Additionally there is no warranty coverage for any Products that fail or have been damaged due to altera tions or modifications abuse misuse neglect improper installation instruction handling operation maintenance or storage accidental or intentional damage normal wear and tear unauthorized service or repairs including unauthorized adjustments or calibrations performed on the Pro
22. nnn nene 9 20 Fuelha LS ET ST E ERROREM 21 WD a eee cece acetone eee eects 22 Cleaning and MaIntuianee i 23 N Ji m 24 25 Performance CheckllIst a 26 27 P N 750306 Page 2 TO REDUCE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOW ING IMPORTANT PLEASE READ AND FOLLOW THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION HOWEVER WE RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLA TION DO NOT REMOVE PERMANANTLY AFFIXED LABELS WARNINGS OR DATA PLATES FROM YOUR APPLIANCE THIS MAY VOID THE MANUFACTURER S WARRANTY AND OR HINDER EFFECTIVE SERVICING AND MAINTENANCE THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE AND THE CONSUMER IS TO RE TAIN THEM FOR FUTURE REFERENCE PLEASE OBSERVE ALL LOCAL AND NATIONAL BUILDING CODES AND ORDINANCES IF NO LO CAL CODES ARE APPLICABLE PLEASE FOLLOW ALL WIRING REQUIREMENTS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 EDITION PLEASE CHECK WITH A QUALIFIED AND TRAINED INSTALLER OR YOUR LOCAL CODES FOR ANY MAKE UP AIR REQUIREMENTS THIS HOOD IS FOR RESIDENTIAL USE ONLY AND IS NOT DESIGNED FOR INSTALLATION OVER A COMMERCIAL PRODUCT MAKE SURE ALL POWER IS TURNED OFF AT THE MAIN BREAKER OR FUSE BOX BEFORE SERVIC ING O
23. purposes of this Limited Warranty cosmetic components include top grates ring grates plate rail kick panel body sides glass control panel door panel back guards oven seals light bulbs and enameled parts All warranty claims for cosmetic items must be reported immediately within seven calen dar days of delivery or such claims will not be honored Please refer to your installation checklist to acti vate your limited warranty One 1 Year Limited Warranty Prizer Painter warrants that all functional components except cast iron burner tops of its products will under normal use and service be free from defects in materials and workmanship for a period of one 1 year from the date of delivery the Warranty Period to the original retail purchaser For purposes of this Limited Warranty functional components include all components of the product other than the cosmetic components covered by the initial seven day limited warranty and the cast iron burner tops covered by the 10 year limited warranty Floor models are not covered under the One 1 Year Limited Warranty but are covered by a Ninety 90 Day Labor and a one 1 Year Limited Parts Warranty with proof of date of install and a completed Installation Checklist Demonstration units are not covered under the one 1 Year Limited Warranty Please refer to your installation checklist to activate your limited warranty Failure to send a complete and accurate copy of the installation checklist
24. red by the highest levels of management We hope you enjoy your new appliance and we THANK YOU again for believing in our product as much as we do The staff and team at Prizer Stove Works PRO LINE HOOD AREND P N 750306Page 5 WELCOME to the exciting world of BlueStar M cooking You have purchased one of the finest appliances available for home use which shows that you take cooking seriously As the owner of a new BlueStar appliance you can look forward to years of cooking enjoyment You will prepare meals with the speed and accuracy of a professional chef right in your own kitchen equipment is designed and manufactured to the highest quality standards in the in dustry specifically to meet the needs of the world s most demanding chefs you From simmering to saut ing bak ing and broiling these versatile appliances provide the flexibility you need in any cooking application Commercial styling adds a touch of elegance to your kitchen like no other appliance can What s more this high quality high performance appliance is backed by our professional service network from coast to coast to provide you with quick competent technical service should the need arise Please take a few moments now to fill in the information below for your future reference In the event you require parts or service this information will be needed to ensure DATE OF PURCHASE OE 5 ADDRESS DATE OF INSTALLATION
25. ring Diagram PL36240 PL42240 24 depth No blower Sold and Packaged Separately Four 4 Stainless Steel Baffle Filters Two 2 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram PL48240 PL54240 24 Depth No blower Sold and Packaged Separately Six 6 Stainless Steel Baffle Filters Three 3 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram PL60240 PL66240 24 Depth No blower Sold and Packaged Separately Six 6 Stainless Steel Baffle Filters Three 3 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram P N 750306 Page 8 PACKING LIST FOR PYRAMID STYLE HOOD SERIES PC30240 24 depth No blower Sold and Packaged Separately Two 2 Stainless Steel Baffle Filters Two 2 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram Duct cover sold packed in separate box 2 of 2 PC36240 PC42240 24 depth No blower Sold and Packaged Separately Four 4 Stainless Steel Baffle Filters Two 2 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram Duct cover sold packed in separate box 2 of 2 PC48240 PC54240 24 Depth No blower Sold and Packaged Separately Six 6 Stainless Steel Baffle Filters Three 3 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram
26. s and lights Switches work YES NO Lights work YES NO Electrical Connection Correct Voltage YES NO Grounded Electric YES NO Polarity correct YES NO MAIL IN COPY P N 750306Page 27
27. ual YES NO Product was installed Level YES NO Properly Hung 1 YES O NO Clearances min 30 above counter YES NO Controls and lights Switches work YES NO Lights work YES NO Electrical Connection Correct Voltage 1 YES NO Grounded Electric YES NO Polarity correct 1 YES NO CUSTOMER COPY P N 750306 Page 26 PERFORMANCE CHECKLIST This checklist has been developed to assure proper installation of your appliance To validate your warranty you must mail or fax this form and a copy of your receipt to Warranty Department Prizer Painter 600 Arlington Street Reading PA 19611 Fax 610 376 2596 Customer Information Please Print Product Information Please Print Name Model No Address Serial No City Purchase Date State Zip Code Installation Date e mail nstalers Name Telephone Company Dealer Telephone CHECK ALL THAT APPLY Unpacking Packaging Condition GOOD BAD Baffles Included YES NO Flue optional on some units YES NO Owner Manual Included YES NO User Manual Included YES NO Appearance and Aesthetics Exterior clean and scratch free YES NO Interior clean YES NO Installation Read User Manual YES NO Product was installed Level YES NO Properly Hung YES NO Clearances min 30 above counter YES NO Control
28. within 15 days of installation will invalidate your limited warranty Ten 10 Year Limited Warranty Prizer Painter warrants that all functional components of its cast iron burner tops will under normal use and service be free from defects in materials and workmanship for a period of ten 10 years from the date of delivery the Warranty Period to the original retail purchaser Please refer to your installation checklist to activate your limited warranty Failure to send a complete and accurate copy of the installation checklist within 15 days of installation will invalidate your lim ited warranty If any Product fails to comply with the foregoing Limited Warranties during the applicable Warranty Pe riod Prizer Painter will at its option either 1 pay the reasonable labor and material costs to have the Product repaired by a factory authorized service agent 11 replace the Product or defective component of the Product or 111 if in Prizer Painter s sole judgment circumstances are such as to preclude the remedy ing of any breach of warranty by repair or replacement then Prizer Painter will refund the purchase price paid by the original purchaser repairs or replacement service must be performed by a factory author ized service agent Additionally all Products must be accessible for service in the home and must be ac cessible via public highways within 100 miles roundtrip of a factory authorized service agent The pur chaser will be r