Manual - Ambient
Contents
1. experience quality Version 1 3 3 48 Enter the TC menu to adjust the timecode frame rate timecode output level for pin 5 Lemo TC Select je for adjusting the frame rate Adjust by toggling the config switch left right push in to select new frame rate Available values 23 976 24 25 29 97 30 29 97D 30D fps D drop frame And again changes need to be confirmed Select Level to adjust output level on Lemo TC The adjustable range is from 45 dB to O dB Default level is O dB This equals 3 Vpp without load 1 5 Vpp or 0 dBu into 1 K Ohm Select by toggling left right select by pushing in the config switch www ambient de en 19 AMBIENT RECORDING ACN M L Version 1 3 3 48 E The SYS menu lets you adjust OLED brightness displays info about the device and lets you reset the Lockit to factory defaults Enter the configuration by pushing in the config switch Adjust display from 1 to 10 and push in to select value The curser will jump to the settings to select the time out Choices are Never 5 seconds 30 seconds 1 minute 5 minutes Select INFO to display information about the ACN ML Serial Number Main firmware version Mac address SYS gt Factory Reset Selecting yes and pressing the config switch restores factory defaults to JamTC Auto Sync Off TC 25 fps ACN Off Display brightness 3 display auto off 30 sec TC offset NULL 20 Ambient Recording GmbH 2015 experien
2. E For user bits is selected in the GEN gt JamTC settings is selected in the GEN gt JamTC settings and the device has already been if the GEN gt UB gt JamUB is set to manual OAmbient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 10 LED Indications As used to from former devices of the Clockit Time Code family the ACN ML has a red and a green flashing LED to display operation and battery status e red slowly blinking power applied unit switched off silent charge of backup cell eo red and green constantly lit unit switched off external power connected backup battery fully charged Trickle charge current at 12V typical 35mA O 1 2 3 Aseconds e eee red flashing in 1 second intervals running but not jammed or set e o green flashing in 1 second intervals running jammed or set manually This is the normal operation mode e es ee red double flash every 2seconds battery low not jammed or set e ee ce green double flash every 2seconds battery low jammed or set e eo 00 00 00 red double flash every second TC video not sync not jammed or set e eo oo oo 00 green double flash every second TC video not sync jammed or set The double flash on every second is shown while invalid combinations are configured or while syncing the genlock signal to time code after configuration changes or jamming e ooo e e combination of not sync and low battery not set or jammed e
3. JamTC menu 16 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 GEN gt UB gt Edit UB In Edit UB the user bits can be edited manually Decrease or increase by toggling left right Holding left right is fast backward forward Push to select value curser jumps to next digit When finished the selected new value needs to be confirmed Select new to apply or the cancel by selecting old EXIT takes you directly back to main menu without changes www ambient de en 18 AMBIENT RECORDING ACN ML Version 1 3 3 48 I The SYNC menu enables setting of the sync signal format type and rate Select the different settings by pushing the config switch Navigate by toggling the config switch left or right Defaulted Off PPF selects a pulse per frame signal This is used to trigger certain video cameras The PPF signal is available on pin 3 of the Lemo socket For the PPF signal rate single double quad can be selected along with a high low or low high transition Pushing the config serves the function of selecting items or parameters If any changes have been selected you will be asked to confirm If changes have been selected with active sync you need to reconfirm before apply m deactivates any sync signal This is the default setting and should be used if timecode only is required OAmbient Recording GmbH 2015 ACN ML TC gt FPS
4. amp Approvals Warranty Ambient Recording GmbH warrants the Master Lockit ACN ML synchronizer against defects in materials and workmanship for a period of ONE 1 year from date of original retail purchase This is a non transferable warranty that extends only to the original purchaser Ambient Recording GmbH will repair or replace the product at its discretion at no charge Warranty claims due to severe service conditions will be addressed on an individual basis THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AMBIENT RECORDING GMBH DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AMBIENT RECORDING GMBH IS NOT RESPONSIBLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM ANY BREACH OF WARRANTY OR UNDER ANY OTHER LEGAL THEORY Because some jurisdictions do not permit the exclusion or limitations set forth above they may not apply in all cases For all service including warranty repair please send the ACN ML along with proof of purchase date to your retailer or if not applicable to Ambient Recording GmbH Schleissheimer Str 181 C DE 80797 Muenchen Germany Please obtain a return authorization through the contact form on our website before sending in a unit May 2015 Klaus Grosser Ambient Recording GmbH Approvals C CE Conformity Statement Declaration of Conformity According to ISO IEC Guide 22 Manufacturer s Name A
5. Of EN 60950 1 with correct polarity voltage range and current rating Disregarding recommended power requirements may damage the product or even risk explosion of the internal backup cell Do not perform software updates in situations in which the integrity of mains supply cannot be granted such as thunderstorms and remove connections from and to all devices directly or in directly connected to mains When using the wireless connection place it centrally and keep it distant from sources of possible interference such as microwaves or electrical devices with large metal surfaces Only use the original external antenna directly and firmly attached to the socket Extension or use of 3rd party accessories is not permissible Only use the included WiFi dongle that was carefully evaluated for best performance and leave it connected all the time Re attaching the WiFi dongle during operation will require a system restart Never open the unit Inappropriate and unauthorized access will void the warranty and imply possible risk of harm to the user When disposing the unit follow the legal requirements for recycling electronic equipment www ambient de en 3 AMBIENT RECORDING ACN ML Version 1 3 3 48 4 Powering The ACN ML can be powered by 5 to 24 Volts DC via either indicated Hirose 4 pin connectors pin 1 carrying GND pin 4 positive voltage The connectors are configured loop through Only apply power through one socket Upon app
6. goes red and sync failed will be displayed The slave Lockits now compare their own time with the regularly received time stamps and will adjust their tune value to stay closely in sync with the master the system latency is down to half a video line SD if all Lockits are well in tune to each other initially The latency in us measured time in seconds since start of C Jam current tune value and proposed tune value are displayed in an expert view window that is accessed by selecting SYS gt INFO and then pushing the toggle switch to right line 1 Line 2 is debug info line 3 is used for tune value In this mode a unit that was slave and has been power cycled for instance for changing batteries will automatically re sync when booted The master unit will be in C Jam mode but not send sync signals after reboot Should it become necessary to reboot the master a former slave may be used to initiate the C Jam and become master This way the set timecode is maintained It is recommended maintaining one master and to re sync the set after power cycling to avoid complications caused by more than one master in operation on location which may lead to unpredictable errors Troubleshooting sync failed messages For timecode e lfthe frame rates of sending and receiving device differ in integer vs non integer frame rates or PAL vs NTSC e g 25 fps and 29 97 fps the sync command is rejected e f e f jammed before
7. ooo e 0 combination of not sync and low battery set or jammed 0000000000 alternating colors during firmware update www ambient de en 25 AMBIENT RECORDING ACN M L Version 1 3 3 48 11 Firmware Update New features improvement and fixes for the ACN ML will be available for download from our website http ambient de en product master lockit Download the update file to a WiFi capable computer and log in to your Master Lockit s web interface Make sure your WiFi adapter is set to DHCP and use the WiFi s SSID name as password And enter masterlockit local or 70 0 0 7 in the address line pf your browser Select Firmwareupdate from the System dropdown menu on the upper right corner Select Choose File browse the location of the file just downloaded it should read update xxxx tar gz then click on Upload amp Restart Your Master Lockit should now automatically update and reboot when finished TC 15 23 53 20 P ML Demool Tirmecode bhet relate that ant Metadata Export Firmwareupdate F 1 re ST mo EN Ther Sie comme should fran the Gone update act y l amp Ambient Re arder Note if the update involved changes to the TC generator firmware the Lockit circuitry will sequently shut down until both LEDs start to flash alternating and finally goes into charging mode with the red LED on solid and the green flashing Do not interrupt this process or remove power until this stage has complet
8. 1 Supply adequate power source The red LED should blink slowly in a 2 seconds interval This indicates charging of the internal backup battery is in progress If battery is filly charged red and green LED will come on solid 2 Switch on the Master Lockit by pressing down the 3 function wheel and holding it until the OLED display comes on 3 You can now immediately start to manually set the required timecode frame rate Manually enable the ACN by selecting C Jam and choose an ACN channel NOTE make sure that all your Lockit Devices on set are in the same ACN channel 4 Wait until the square indicator on the left bottom of the display has become solid blue to indicate the metadata server has completed booting Use a smartphone tablet or computer to log in to the Master Lockit s WiFi The password for log in will be the same as the WiFi name The default setting will be displayed in the format ML xxxxx representing a 5 digit random phrase This can be changed by the user 5 Open a browser and enter http masterlockit local respectively http 10 0 0 1 or open the Master Lockit Web Interface in TonMeister or LockitSCRIPT App 6 Hit System Reset in the System Menu This will clean the Master Lockit from all old clip metadata and ACN connections for a fresh start TC 15 21 15 05 7 til Demeo 7 Rename WiFi if desired for better identification Especially for multi camera shoots it is highly recommended to rename the Maste
9. RECORDING Lockit Timecode Master Lockit ACN ML gt MASTER LOCKIT ACN ML www ambient de Rev 1 3 3 48 experience quality ACN ML Table of contents O MP A AA IN oe G2 8 3 8 4 8 5 10 11 12 13 Version 1 3 3 48 Introduction Package Contents Safety instructions Powering Description Quick Start Guide Setup Menu Diagram Menu Description Generator Menu Sync Menu Time Code Menu System Menu ACN Menu LED Indications Firmware Update Physical Specifications Warranty amp Approvals Recommended accessories www ambient de en experience quality page U PR 0 0 N 13 15 18 19 20 21 25 25 26 27 29 AMBIENT RECORDING ACN ML Version 1 3 3 48 1 Introduction The ACN ML Master Lockit combines the state of the art high accuracy Lockit timecode technology by Ambient with advanced metadata administration and sharing over the Lockit Network It implements a dual system design through a full featured ACN Lockit circuitry with adapted software for no compromise fail safe timecode integrity and a powerful multi core CPU platform for unsurpassed mobile metadata processing Providing local and set spanning line level accurate timecode and metadata over ACN plus WiFi routing for Lockit Network apps and certified devices it can work both autonomously as hub or satellite in your timecode and metadata network An integrated backup cell with automatic charge when supplied w
10. Version 1 3 3 48 FPS y FPS 23 976 amp 24 25 amp 29 97 amp 30 amp 29 97D Level V Select TC level 0 dB to 45 dB y Display lt gt Info Factory Reset Display Y Brightness 1930 10 y AutoOff never 5sec xe SMIN INFO y Factory Reset 4 loads default settings y MODE MODE 4 ACN OFF e JAM CJAM TX RX JAM amp onetimejam gt CJAM 4 continuousjam autosyno TX transmit external free orrecrunTC RX V receive free or recrunTC 000000 y Select ACN channel 11 20 26 Back to ACN ACN Y MODE CHNL amp ANT PWR SYNC MODE ACN OFF amp JAM amp CJAM amp TX RX Selected mode highlighted S gt OFF disablesACN 00000 CHNL 4 select ACN channel 11 to 26 ANT y Select LNA off on PWR 4 ACN RF power 8 to 18 dBm SYNC notavailablein TX or RX JAM Y Send sync broadcast yes lt gt no C JAM Start continuous jam yes e no it C Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 8 Menu Description POWER The Master Lockit must be powered from either of it s 4 pin Hirose sockets The operating voltage range is 5 24V DC regulated with pin 1 being GND and pin 4 carrying V per the industry standard NOTE The two power sockets are wired in parallel for loop through of voltage It is mandatory that only one socket must carry supply voltage at any given time With power applied red LED ove
11. caly jam to externally fed timecode and will not re jam as it has consistent present signal displayed by a lock symbol that has replaced the A It will revert to a ready for re jam when the external TC source stops and restarts for 3 seconds or is disattached for the same time Off defeats the Jam mode completely The generator will not react to incomming TC This is useful to protect your TC master becoming accidentially misadjusted when using it to jam other equipment with a bi directional cable Note the jam indicator on the main screen is permanently changed to a lock The manual once option will let you jam the generator one time only and is indicated by an M that the unit is ready to accept a TC jam Once jammed the unit will switch Off mode with an according lock symbol To reopen the input for jamming with present external timecode repeatedly press the config switch to toggle through the modes Of course you can also change the mode or reboot the unit www ambient de en 15 AMBIENT RECORDING ACN M L Version 1 3 3 48 GEN gt EDIT This allows manual editing of timecode values Decrease or increase by toggling left right Hold for fast forward backward Push to select Pushing while on the frames position sets time and takes you to the confirm screen Per default the cursor sits on old This prevents resetting your timecode inadvertently To keep the previous time just press while the cursor is o
12. ce quality ACN ML Version 1 3 3 48 The ACN menu accesses Lockit Network configuration ACN gt MODE Off Per default this is OFF so all options will be hidden To change hit and select the desired option ACN gt MODE gt JAM The JAM mode enables sending of a sync command to other ACN ready devices on same mode and channel or to receive a sync command from them This serves to remotely one time jam sync all units on the set from one arbitrary unit T C JAM as continuous jam builds up on jam Repeated bursts of timestamps are sent out every couple of seconds jamming previously unset devices which adjust their clock reference to the received information and re transmitting status information This is also the metadata mode and thus the one in which the Master Lockit will mostly be used either as hub or as satellite ACN gt MODE gt TX This mode converts the unit into a timecode transmitter that will distribute external TC through ACN to units in RX mode If progressing timecode is detected the ACN ML jams to it and sends out a jam command to the slaves When the external timecode stops a stop command is sent to the slaves If static timecode value is recognized as sent by a video camera or similar the timecode is stopped while a static timecode is sent on the timecode output of the slaves as well as on the output of the unit that is in TX This feature enables synchronized remote roll of devi
13. ces that support recording triggered by timecode www ambient de en 21 AMBIENT RECORDING ACN ML Version 1 3 3 48 ACN gt MODE gt RX This is the corresponding receiver setting for the TX mode as described above Note in TX RX record run timecode mode no sync signal will be generated SM After switching from OFF to any of these 4 modes you will be EE redirected to pick an ACN channel from 11 through 26 NOTE all devices communicating via ACN need to be on the same channel AND firmware version You also can run different modes each on a dedicated channel on the set ACN gt MODE ON After having picked an ACN channel for radio transmission the ACN menu will show several options Lets you reconfigure the previously chosen transmission channel Lets you enable a Low Noise Amplifier for enhanced range NOTE This comes at the expense of backup battery life ACN gt PWR PWR lets you increase the output power of the transmitter between 8 to 18dBm For changes a PIN is required 22 Ambient Recording GmbH 2015 experience quality Version 1 3 3 48 The default of 8 dBm is globally permissible Check if your local regulations allow higher output before requesting a PIN ACN gt SYNC Selecting SYNC opens the screen for sending out a sync command to all ACN devices that are one the same JAM mode and channel Depending on the mode the confirm page reads slightly different Defa
14. e of increased power drain As ACN is switched on this will be reflected accordingly in the bottom line the rectangular icon next to it gives information about the server It will start blank and soon change to solid after boot up C Jam indicates the selected ACN mode 11 the radio channel If the unit is configured to be the C Jam master these indicators will change to sync sent with each C Jam broadcast every couple of seconds If the display is switched off power save pushing the config switch once will turn it on again without doing any changes Also a timecode jam activates the display 14 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 MAIN MENU Pushing the config switch briefly will replace the lower line with the main menu You can navigate forth and back through the various sections by toggling the 3 function wheel in the corresponding direction and select the highlighted sub menu by pushing again Pressing the config switch when EXIT is highlighted exits to the main screen If no action is performed the unit will revert to the main screen after a few seconds This menu will lead you through a subset of parameters regarding the timecode generator GEN gt JamTC First sub menu is to configure how the generator can be jammed from external AUTO is the default setting When activated the screen will display an A to the left to the running timecode The generator will automati
15. ed Now reboot the Master Lockit by pressing the 3 function wheel as usual The display should now welcome you with a new firmware version 26 Ambient Recording GmbH 2015 ACN ML 12 Dimensions Weight Power Connectors Lemo TC Lemo ACN experience quality Version 1 3 3 48 Physical specifications L W Hy 91 102 x 65 x 33 mm net incl sockets not incl antenna or WiFi Stick 0 282 Kg 35mA 1 5A Lemo series OB 5 pin matching connector FGG JGG 0B 305 CLADxx pin 1 GND pin 2 LTC IN pin 3 ASCII IN OUT pin 4 Tune reference 1 92 MHz out pin 5 LTC OUT adjustable output level Lemo series OB 5 pin matching connector FGG JGG 0B 305 CLADxx pin 1 GND pin 2 LTC IN pin 3 currently not used pin 4 currently not used pin 5 LTC OUT 3 3 Volts DC OUT Lemo ACN remarks e GPO is a timer driven output with TTL output signal 47 Ohm series resistor e GPlis atimer driven input and even a timer driven output with an open drain transistor It has configurable pull up 30k and pull down 20k resistors e The event switch has a 200 mA fuse between pin 3 and 4 Antenna SMA F www ambient de en 27 AMBIENT RECORDING IEEE 802 15 4 2 4 GHz Band 11 2405 13 2415 15 2425 17 2435 19 2445 21 2455 23 2465 N Ul 2475 28 Ambient Recording GmbH 2015 Version 1 3 3 48 ACN ML experience quality ACN ML Version 1 3 3 48 13 Warranty
16. ill keep both systems alive for even lengthy set reconstructions or breaks and secure a coordinate shutdown on power drain 2 OAmbient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 2 Package Contents e ACN ML Master Lockit e ACN Antenna attached to ACN ML e USB WiFi Stick attached to ACN ML e Manual 3 Safety instructions For your own safety and trouble free use of your ACN ML Master Lockit please carefully read through the instructions below Always keep a copy of these instructions and hand them out with the unit to other users This unit is exclusively intended for indoor use Keep it safe and away from water rain and humidity and dry under all circumstances even when powered off Clean gently with a slightly moistened cloth and never let water detergents or liquids of any kind get into the unit as this will imply the risk of short circuits and electrical hazard Keep distant from sources of heat and never expose to direct sunlight Admissible ambience temperature is from 5 to 50 Celsius Do not throw or expose to mechanical impact and keep it safe from hard vibrations Only use genuine accessories such as cables antennae etc which have been included with the unit or supplied by an authorized dealer Always observe integrity and the pertinent compatibility with all units connected to Powering from external sources is exclusively limited to the use of LPS sources in compliance to part 2 5
17. it is allowed to be setto hub mode for proper metadata networking Also only one unit must be sending out a C Jam broadcast Although not mandatory it s still advised to be the hub Make sure that all the others are in satellite mode blue interface 9 Enter the tab Timecode in your hub s interface to set TC and enable C Jam broadcast All other Lockit devices on set will switch to the hub s TC Now you are ready to shoot Congratulations you have successfully configured your Lockit Network All you need to do now is switch on the units every morning set TC on your hub enable it s C Jam transmission and look at the battery status of the remote units within the web interface every so often to know when replacement is required Other functions in the Master Lockit Web Interface Timecode Remote Control hub mode only As you already know one of the Master Lockits on set is the hub This will enable the options in the Timecode tab to enter a TC manually or by the system clock of the device to which you are accessing the interface When the Master Lockit has jammed to the desired time the running TC in the upper left corner will pulse Now you re set to push the Start C Jam Broadcast and sync up the set NOTE C Jam Broadcast can only be triggered after the generator set which is indicated by a green flashing LED on the unit Doing this will help you avoid messing up the timecode when the C Jam master has accidenta
18. la norme NMB 003 du Canada May 2015 Sebastian Fell Ambient Recording GmbH 30 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 14 Recommended accessories ACM TL Mounting accessory for attaching the device to a 3 8 thread ACM FS Adapter 3 8 to cold shoe MLC L1B10 Ethernet cable Master Lockit to Arri Alexa RJ45 to Lemo Series 1B 10 pin 0 5 m MLC L1B10P Ethernet cable Master Lockit to Arri Alexa and powering RJ45 to Lemo Series 1B 10 pin 0 5 m with breakout to Hirose 4 pin for powering www ambient de en 31 AMBIENT RECORDING ACN ML Version 1 3 3 48 AK HS4 Adapter cable Hirose 4 pin to Hirose 4 pin 0 5 m AK HS4 LOB2 Adapter cable 12 V to Hirose 4 pin 0 5 m AK HS4 PC2M Adapter cable Hirose 4 pin Anton Bauer D Tap male 0 6 m LTC OUT Adapter cable Lemo Series OB 5 pin to BNC LTC OUT Epic N Adapter cable Lemo 5 pin to Lemo series 00 4 pin for use with RED Epic Scarlet 32 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 TC 1 0 Adapter cable Lemo 5 pin to Lemo 5 pin for use with ARRI Alexa LTC OUT35 35F Lemo 5 pin to TRS 3 5 mm 90 right angle amp jack For feeding microphone and timecode into DSLR microphone cable to left channel length 20 cm TC cable to right channel length 40 cm Pad 20 dB ANT 2 4 SMA M Antenna straight ANT 2 4 SMA M90 Anten
19. lly run out of power and restarted during a camera roll In 8 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 this case you may also re jam the generator and activate the C Jam broadcast directly on the Master Lockit It is important you only do this with no units in active record ACN Radar hub mode only You can add all ACN enabled Lockit devices to be monitored and controlled by the ACN Radar Just make certain the correct timecode rate and sync format if applicable of the camera recorder are selected and enable the ACN by selecting the C Jam mode using the ACN channel used on the hub Ultimately all units should be blinking blink green to indicate correct sync while displaying the same timecode At the same time they will appear on the ACN radar on the hub s web interface showing you additional valuable information The hub will list all Lockits ever logged in A green header indicates there is an active connection through ACN while a gray header indicates a unit is offline NOTE Remove any units that are not or no longer in your active setup by clicking on the trash can You may also rename the remaining Lockits freely or according to their WiFi name just make sure you monitor each unit for battery replacement If the heading is gray the unit has lost power Metadata Network If the Master Lockit is connected to a supported camera or recorder with metadata interface go to the Metadata Netw
20. lying external power the internal battery will automatically be charged The power source must be capable of supplying 1 5A for charging the internal battery While in operation the active power source is indicated in the upper right corner of the display EXT means external power is applied with appropriate voltage and current whereas INT indicates that the unit is running on its integrated backup cell Typical values in operation with backup cell charged 500mA 5V DC 220mA O 12V DC 120mA O 24V DC 4 OAmbient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 5 Description 00900 5 6 OM 2 AMBIENT MASTER LOCKIT ACN MI eure MITO WiFi adapter attached to USB A port do not remove or replace USB A port not in use DC IN through 4 Pin HRS see page 4 Ethernet port for metadata transfer RJ45 OLED display see page 14 ff IR transceiver communication port for ACC501 controller 3 function configuration switch 3 function pushing in toggle left right Status LEDs see page 26 ACN antenna SMA type attached to unit do not remove Lemo ACN socket see page 27 Lemo TC socket see page 27 DC IN through 4 Pin HRS see page 4 Reset button see page 13 3 8 thread mount EB OQ Q 9 amp 9 C 9 6 9 O www ambient de en 5 AMBIENT RECORDING ACN M L Version 1 3 3 48 6 Quick Start Guide Prepare for a new project
21. mbient Recording GmbH Manufacturer s Address Schleissheimer Str 181 C DE 80797 Muenchen Germany declares that the product ACN ML Master Lockit is in conformity with EN 60950 1 2006 A11 2009 A1 2010 A12 2011 AC 2011 EN 300 440 1 V1 6 1 EN 300 440 2 V1 4 1 EN 301 489 1 V1 9 2 EN 301 489 3 V1 4 1 which is indicated and affirmed by the applied CE marking www ambient de en 29 AMBIENT RECORDING ACN ML Version 1 3 3 48 FE FCC Statement The FCC requires that the following statements be included in this manual for ACN ML FCC 8 15 19 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Canada CNR Gen Section 7 1 3 This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectri
22. n old To accept the edited TC move the cursor to highlight and press down Either way will take you back to the main menu CAUTION Resetting the generator will restart the sync signal Doing this while recording will result in a corrupted file GEN gt OFFSET An offset can be entered between the jammed timecode and the timecode on the output of the ACN ML Use this to compensate the processing delay that some file base cameras produce If offset is enabled it will be displayed in the main screen This shifts only the timecode while the sync signal stays locked to the frame start of the jammed timecode running in background The offset has a range of 10 frames in 0 05 frames steps equals 2 ms at 25 fps GEN gt UB In the UB menu the user bits are being displayed The user bits can be edited manually and the jam behavior managed itt ALIAS de GEN gt UB gt JamUB Under JamUB the jamming behavior is managed normal the user bits are being taken from external timecode manual the user bits are not being overwritten by external timecode This mode is to be used if you want a custom entry such as date and camera ld insert user bits can be inserted on the fly Note if the source time code was unplugged for more than 3 seconds and reconnected the ACN ML will re jam If inserting changed user bits after interrupted timecode you must also set the ACN ML to jam once or off in the
23. na right angle www ambient de en 33 experience quality MADE IN GERMANY Ambient Recording GmbH Schleissheimer Stra e 181 C D 80797 Munich vox 49 89 36005510 0 fax 49 89 651855 www ambient de info ambient de O 2015 Ambient Recording GmbH
24. ork tab This is where to select the connected camera from the supported devices This version of firmware only supports the Arri ALEXA Follow the instructions on the screen Note The required serial number for Arri ALEXA can be found on top of the camera as well as within the system menu The Metadata Network tab allows monitoring of proper connections from other Lockit devices to cameras or recorders if present LockitSCRIPT or TonMeister apps logged into the hub s WiFi will also be displayed Metadata Export The Metadata Export tab allows you to watch the collected clip metadata from all devices in the Lockit Network The Master Lockit in hub mode will display all transmitted clip metadata from all Lockit devices connected to a supported camera NOTE Master Lockits in satellite mode stores clip metadata from the camera to which it is connected while transmitting it to the hub mode enabled Master Lockit as well To get an overview of all the clips on set always check the hub s web interface www ambient de en 9 AMBIENT RECORDING ACN M L Version 1 3 3 48 The clip contains technical camera metadata the amount and specific content is determined by the camera type When the LockitSCRIPT app is connected to the Master Lockit this technical metadata is supplemented by the content metadata of this script supervising app You are able to filter clips by camera TC or shooting day Monitor them or export the info
25. que subi m me si le brouillage est susceptible d en compromettre le fonctionnement FCC 15 21 Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC 15 105 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help ICES 003 This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a
26. r Lockit s WiFi name to clearly identify its position and determine whether or not the unit is set to hub mode You do that in the WiFi Settings within 6 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 the Settings Menu or by just hitting the WiFi symbol in the header After hitting reconfigure the Master Lockit will reset its WiFi so you will need to log in again with new credentials TC 15 22 24 16 Hub Mode 5 Mi Demedl rime nate Metadata Mat mur kb Metadata lapot WiFi settings on T m A UN e ort a Vh m ta f AEL Q armar Reu NOTE This name must be at least 8 digits long Names like soundcart_HUB camera 1 or simply ascending numbers can later greatly help to better identify the individual units This works well with the option to assign unit names in the ACN radar page of the hub 8 Continue with the next Master Lockit one after another After that enable Hub Mode on ONE and ONLY ONE of your Master Lockits by switching it to Hub on the upper right corner of the headline Now the interface will turn from blue to orange and you should see all other ACN enabled Lockit devices in range are then displayed in ACN radar www ambient de en 7 AMBIENT RECORDING ACN M L Version 1 3 3 48 FC 157195230 Deu ACN Radar Master Lochi 140 061 Mj TR ST 77 Ul Ext Power io FRE 2 WARNING Only one Master Lock
27. r the display will slowly blink to indicate charging of the integrated backup cell Fully charged red and green LED will be lit permanently The battery will keep the unit powered for a couple of hours depending on the processing load of the unit To turn on the ACN ML press and hold the config switch for four seconds A The unit will come on showing basic system information such as model Serial number and Firmware version After boot up has completed you will be greeted by the home screen EU If the unit has not been configured the only additional information will ME be a rectangle in the lower left corner indicating the metadata server status No icon means server is offline blank booting solid online and ready If the unit had been configured it may display the last settings and look something like this NOTE After a complete power loss C Jam broadcast will be suspended and can only be started after re jamming the internal generator indicated by a green blinking LED To turn off the unit press and hold the switch for 4 seconds while on the home screen The display will show To power down confirm by pressing again Release the button to abort and the unit will revert to the main screen after 3 seconds Note if the unit becomes stuck displaying powering down due to indifferent server status you may keep the button pressed for 10 seconds count the LED blinks until a message Should appear to release the bu
28. rmation in one of the provided export formats 10 Ambient Recording GmbH 2015 experience quality ACN ML Version 1 3 3 48 7 Setup Menu Diagram This passage will guide you through the menu structure of the Master Lockit as accessible via the three function wheel on the top and OLED display All TC related adjustments such as frame rate level and offset as well as selecting correct ACN settings must be performed here Main Display will always show jam mode timecode frame rate and power status in the upper section Mid section gives sync info if applicable lower section displays either ACN related info such as server status mode and channel or menu Y push select switch down to enter the main or sub menu and to confirm toggle left right to navigate or increase decrease value Y push again to confirm selected value Default settings are Main Menu GEN SYNC TC SYS ACN amp EXIT an 4 JamTC EDIT gt OffSet lt gt UB JamTC 4 AUTO Off manual once Edit 4 HH MM SS FF Offset J Offset 00 00 10 frames in 0 05 increments UB VL JamUB EDIT UB EXIT JamUB normal amp manual amp insert EDIT UB 4 00 00 00 00 EXIT 4 back to main menu y SYNC L PPF OFF PPF 4 1x e 2x e VHIGH gt 1 4Pulses Per Frame rising fallingedge OFF 4 NO SYNC OUTPUT y TC y FPS Level www ambient de en 11 SYS ACN Exit AMBIENT RECORDING ACN ML
29. tton for a failsafe shutdown If everything fails gently pinch www ambient de en 13 AMBIENT RECORDING ACN M L Version 1 3 3 48 into the reset hole on the bottom side with a SIM release tool paperclip or similar This will immediately cut the power Just press gentle and briefly MAIN SCREEN The main screen is displayed during normal operation mode lt displays the most important status information These include following The upper left corner indicates the jam mode A is for auto M for manual once while the lock symbol in this example would indicate off blocking jamming of the internal generator from external 03 50 on the top right beside the battery indicates the TC generator to Lemo output offset EXT shows that the unit is powered from external If the external source is switched off or depleted the integrated backup cell will take over indicated by INT Note the cell is automatically charged when external power is applied regardless of the unit being switched on To keep the meta data server running and accessible always make sure you start your day with a backup fully recharged over night 25F is the selected frame rate for the timecode generator PPF 4x High informs that the sync output on Lemo B is set to 4 pulses per timecode frame with rising slope LNA indicates active Low Noise Amplification of the ACN receiver improving range performance in critical situations at the sacrific
30. ult is on no to adjust toggle to yes and push to enter NOTE Only ONE unit is allowed to send out C JAM sync broadcasts It is recommended to choose the Master Lockit that also serves as metadata hub After sending out the sync command including timecode and user bits the other units reply and the number of units which replied and were successfully synced are displayed After this the display falls back to main screen In C JAM mode the sync is repeated every 5 seconds and the display will indicate the transmission or reception ME Exits to the main operation screen www ambient de en 23 AMBIENT RECORDING ACN ML Version 1 3 3 48 9 The C JAM Mode C Jam is an enhanced jam algorithm for maximum operation comfort and safety One unit frequently sends out broadcasts to which the other devices intelligently align and adjust their clock speed Once established accuracy falls within one video line or 10uS but even when radio cuts out Lockit accuracy of one frame drift per day is still maintained Thus you never have to worry about misaligned timecode This is also the mode used for enhanced metadata transfer over ACN Any ACL 204 or ACN ML in range that has not been synced or has an offset bigger than 0 5 seconds will be jammed After the initial c jam the master sends a sync command every five seconds Slave units display sync rcvd and their LED goes to solid green for a second If synching fails the LED
Download Pdf Manuals
Related Search
Related Contents
Use the Sleepform User Instructions and get the most out of User`s Manual Manuel de l`utilisateur Anwenderhandbuch Product User Manual - E. G. Kantawalla Private Ltd. HTC One X 7月8日の作業のお知らせ(PDF形式, 583.31KB) Product Manual 261.0215 Projecteur halogène 15 millions de lux Bedienungsanleitung tanJack optic SX Este símbolo tiene como finalidad prevenirle de la Copyright © All rights reserved.