Home
USER`S MANUAL - Safe-T-Alert Marine
Contents
1. YOUR ALARM This CO Alarm is designed to be as maintenance free as possible To keep your alarm in good working order you must TEST THE ALARM WEEKLY using the Test Reset Button See the section Test Procedure in this manual for further information e VACUUM THE DUST OFF THE ALARM COVER At least once a year more frequently in dusty locations use the soft brush attachment from your vacuum to clean the alarm covers e CLEAN THE ALARM COVER WHEN DIRTY Wash the alarm cover by hand Use a cloth dampened in clean water Dry with a soft cloth DO NOT SPRAY CLEANING AGENTS OR WAXES DIRECTLY ONTO THE FRONT PANEL This action may damage the sensor cause an alarm or cause an alarm malfunction Only use household cleaning supplies or similar contaminates when the area around the alarm is well ventilated e OBSERVE THE COLOR OF THE INDICATOR LIGHT At frequent intervals and during your weekly test check the indicator light on the on the front panel of the alarm See the section Operation in this manual for further information HOW TO PROTECT YOUR FAMILY CAUTION The SAFE T ALERT 65 Series combination CO Alarm is designed to protect individuals from the acute effects of carbon monoxide exposure It will not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner To protect yourself family and guests you should INSTALL THE ALARM PROPERLY Carefully read and follow ALL the instructions i
2. has reached the end of its service life and you must replace the alarm The signal is the LED flashing RED RED GREEN GREEN with a beep every 25 30 seconds The EOL Signal may be reset by pushing TEST RESET button on the alarm This will reset the EOL Signal for a period of 72 hours 3 days for a total of up to 30 days After 30 days the signal cannot be reset and the alarm must be replaced DO NOT DISCONNECT THE ALARM UNTIL YOU HAVE A REPLACEMENT ALARM AVAILABLE TO INSTALL
3. heaters galley gas stoves and ovens furnaces defective engine exhaust systems charcoal portable grills other nearby Boats portable generators generator exhaust and other gas powered appliances All produce CO The following are also sources of CO that may affect your Boat Extended operation of unvented fuel burning appliances can build up high CO levels An idling boat or other vehicle in an open area or closed garage Temperature inversions can trap exhaust near the ground and water CO build up can be caused by reverse negative venting of fuel burning appliances including 1 Clogged loose or faulty stacks or chimneys of clothes dryers furnaces and water heaters etc 2 wind direction and or velocity 3 simultaneous operation of multiple fuel burning appliances and or exhaust fans e Portable Generators on your boat or neighboring boats AAWARNING LIMITATIONS OF CARBON MONOXIDE ALARMS THIS ALARM WILL NOT WORK WITHOUT POWER Some reasons for no alarm power are a blown or missing fuse broken wire a faulty wire connection or circuit breaker a discharged battery cut lead wires or improper supply or ground connections THIS ALARM WILL ONLY INDICATE THE PRESENCE OF GAS AT THE SENSOR CO may be present in other areas of the boat and outside the boat MTI recommends installing CO alarms in all sleeping areas and CO monitors around the deck of the boat Do not block or cover the alarm with any object that can pre
4. more information about CO safety and this equipment Make sure that the motor vehicles are not and have not been operating in an attached garage or adjacent to the residence PROCEDURES TO TAKE DURING A CO ALARM IN CANADA WARNING Actuation of this device indicates the presence of carbon monoxide CO gas which can KILL YOU If signal sounds 4 beeps and flashing or solid red light 1 Operate the Test Mute Immediately move to fresh air outdoors or by an open door window Check that all persons are accounted for Do not reenter the premises or move away from the open door window until the emergency responders have arrived the premises have been aired out and your alarm remains in its normal condition 2 call your emergency local service telephone number Fire department or 911 Note CO may also have accumulated outside the boat cabin Turn off all generators and other fuel burning appliances If possible turn off the boats engine and get off the boat move to fresh air away from the boat If you cannot leave the boat turn off all generators and appliances and slowly move the boat toward shore while radioing for help Keep all passengers in well ventilated areas away from engine exhaust TROUBLE SHOOTING GUIDE PROBLEM CAUSE AND SOLUTION GREEN operational LED 1 Wire Connection off 2 Reversed Wiring 3 Main Power Off 4 Missing or Blown Fuse 5 Call 800 383 0269 No sound in test 1 Call 800 383 0269 No RED LED in Test Locke
5. ANUAL ALL RIGHTS RESERVED M 65Marine12012012 1 ATTENTION This user s manual contains important Carbon Monoxide CO alarm installation operation troubleshooting and warranty information Read follow and keep this manual for future reference NOTE If you install or purchase this alarm for another person give this manual to that person IMPORTANT This unit must be replaced within five years of its installation date This unit has an End of Life EOL signal that will sound after 5 years of use Record the installation date in the section Owner s Replacement Record in this manual for future use The replacement date indicates the date beyond which the device may no longer detect carbon monoxide The device should be replaced WHY EVERY BOAT NEEDS A M 65 SERIES CO ALARM Everyone is at risk for carbon monoxide poisoning Particularly sensitive are children pregnant women the elderly and people with lung or heart disease or anemia Carbon monoxide CO is an odorless colorless gas that prevents the blood from carrying oxygen to vital organs CO is 200 times more likely to replace oxygen in the blood The Consumer Product Safety Commission CPSC recommends using at least one CO alarm located outside of sleeping areas For best security locate additional CO alarms in each sleeping area The electronic CO sensor in your SAFE T ALERT CO alarm is very sensitive to CO gas It will not react to most other gases HOW TO TAKE CARE OF
6. BEEN IN STORAGE BEFORE EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE BY PRESSING THE TEST RESET BUTTON A WARNING WARNING THE TEST BUTTON ONLY TESTS THE ALARM CIRCUIT NOT THE SENSORS TO TEST THE CO SENSOR USE A CAN OF SAFE T ALERT CO TEST GAS TO TEST THE 400 PPM CALABRATION POINT DO NOT TRY TO GENERATE CO TO TEST THE ALARM The TEST RESET button tests all ELECTRICAL functions of the alarm It does not check the sensor operation The alarm may be tested at any time The TEST Mute switch is located on the front of the alarm Press and hold the test button for 1 second IMPORTANT If this alarm does not test properly return it immediately for repair or replacement If the alarm is over five years old replace it VISUAL AND AUDIBLE ALARM SIGNALS This SAFE T ALERT CO Alarm is designed to be easy to operate The alarm has two indicator lights that display a specific color for each monitored condition There also is a matching sound pattern for alarm conditions The Red CO LED will flash and the alarm will sound 4 BEEPS then silent for 5 Seconds IMMEDIATE ACTION IS REQUIRED See Procedures To Take During An Alarm This cycle will continue until the TEST Mute button on the front of alarm is pressed Ventilate the boat The RED light will stay ON until the CO has cleared or the alarm will reactivate in approximately 6 minutes if the CO is still present DO NOT RE ENTER THE Boat This alarm will return to normal operation after the Boat is p
7. NUMBER HERE 31632 N Ellis Drive Unit 301 Volo IL 60073 NOTE Mark the RA number in the area shown on the outside of the box 2012 MTI Industries Inc PROCEDURES TO TAKE DURING AN ALARM Follow the alarm procedures for your country The emergency number depends on your travel location See Note below PROCEDURES TO TAKE DURING A CO ALARM IN THE USA WARNING Actuation of this device indicates the presence of carbon monoxide CO gas which can KILL YOU If signal sounds 4 beeps and flashing or solid red light 1 Operate the Test Mute button 2 Call your emergency local service Phone Number fire department or 911 3 Immediately move to fresh air outdoors or by an open door window Check that all persons are accounted for Do not reenter the premises or move away from the open door window until the emergency responders have arrived the premises have been aired out and your alarm remains in its normal operation 4 After following steps 1 3 if your alarm reactivates within a 24 hour period repeat steps 1 3 and calla qualified appliance technician Phone Number to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturers instructions or contact the manufacturer directly for
8. SPECIFICATIONS MODELS M 65 541 M 65 541 R M 65 541 MS M 65 541 R MS M 65 542 M 65 542 R M 65 542 MS M 65 542 R MS POWER SUPPLY 12 VDC NOMINAL CURRENT DRAW 108mA OPERATIONAL TEMPERATURE 40 F to 158 F 40 C to 66 C RELATIVE HUMIDITY 15 5 TO 95 4 AUDIBLE OUTPUT 85 dB 10 feet CO ALARM TRIGGER 4 15 Minutes 400 ppm CASE DIMENSIONS M 65 541 5 5 W x 3 5 H x 1 38 D M 65 542 6 5 W x 3 5 H x 1 38 D WARRANTY 1 Year Limited TESTING LABORATORY ETL STANDARD UL 2034 Third Edition OWNERS REPLACEMENT RECORD Replace this SAFE T ALERT M 65 SERIES CO alarm within 5 years of the installation of the alarm Installation Date Replace Date Installer NOTE The replacement date indicates the date beyond which the device may no longer detect accurately LIMITED PRODUCTS WARRANTY MTI INDUSTRIES INC warrants to the original retail purchaser that its products will be free from defects of material or workmanship for a period of One 1 year from the date of retail purchase If proven to have been defective in original materials or workmanship and returned delivery costs prepaid MTI INDUSTRIES INC will replace this product free of charge LIMITS OF WARRANTY Replacement is your exclusive remedy under this limited warranty or any other warranty including any implied warranty of merchantability for a particular purpose Any and all implied warranties or merchantability or fitness for a particular purpose shall b
9. d in alarm 1 Call 800 383 0269 1 Check Battery Voltage 2 Call 800 383 0269 Malfunctioning alarm LED flashing RED GREEN Beeps every 25 seconds Battery voltage is good and alarm will not reset End of Life Signal 1 Press Test Reset button LED flashing RED RED to reset for 72 hours Can repeat GREEN GREEN Beeps for up to 30 days Every 25 seconds 2 Replace alarm ABOUT THIS ALARM Because CO is a colorless odorless tasteless and highly poisonous gas it can endanger lives even at low levels of concentration The CO Alarm will alert you to potentially dangerous situations The following symptoms may be related to CO POISONING Discuss these symptoms with ALL household members and Boat guests e Mild Exposure Headaches running nose sore or watery eyes often described as flu like symptoms e Medium Exposure Dizziness drowsiness vomiting Extreme Exposure Unconsciousness brain damage and death NOTE Reported cases of CO gas poisoning indicate that while victims are aware they are not well they are disoriented They are unable to save themselves by exiting the boat or calling for assistance Small children and pets may be affected first Your SAFE T ALERT Series alarm helps protect your family members and guests from CO produced while using your Boat CO gas is produced when any type of fuel is incompletely burned Potential sources of CO in and around your Boat can include gas or diesel engine exhaust portable space
10. e UL or recognized permanent wire connectors It is acceptable to connect the 65 Series CO alarm to the main disconnect The alarm will be off along with all other 12 volt equipment when the main disconnect is turned to the off position The Boat must not be occupied when the main disconnect is in the off position SPECIAL WIRING NOTICE DANAGER FIRE RISK DO NOT CONNECT A SAFE T ALERT alarm to non Safe T Alert supplied solenoid You must use a new solenoid with the correct electrical rating Failure to follow these instructions can damage the unit and void the warranty Important The M 65 Series Flush Recess mount case requires 1 1 2 38mm clearance behind the wall MODEL M 65 541 M M 65 542 M 1 Basic Model M 65 541 M M 65 542 M Select a wall location at least 4 off the floor Cut a 5 5 8 143mm W x 3 1 8 79mm H hole For the 60 541 Drill a 1 4 6mm hole for the wires 2 Connect Supply to the Red wire lead Install a 1 amp fuse in the positive circuit Connect the Black wire to the 12 volt Ground 3 Reconnect the power supply Warm up 10 minutes then test the alarm 65 54 1 542 Black 12 volt Battery MODEL M 65 541 M R M 65 542M R Relay Control 1 Model M 65 541 M R M 65 542 M R With Normally Closed relay This unit supplies a relay with contacts rated 12 VDC 3 amp max The relay is energized whenever the alarm is operational It may be used to shut down a generator or
11. e limited to the warranty period from the original date of retail purchase MTI INDUSTRIES INC its dealers and distributors shall in no case be responsible or in any way liable for any incidental or consequential damages for any reason Some states do not allow the limitation or exclusion of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations may not apply to you This warranty gives you specific rights and you may also have other rights which may vary from state to state PRODUCT NOT WARRANTED NOTE There are no user serviceable parts inside the case Opening any SAFE T ALERT product for any reason voids the warranty This warranty does not cover damage or failure resulting from acts of God abuse misuse neglect or faulty installation WARRANTY RETURN PROCEDURES It is MTl s experience that a CO Alarm is sounding for a reason Call ask your dealer to call or e mail our Customer Service Department as listed below to trouble shoot the situation Customer Service Phone No 800 383 0269 E mail Service mtiindustries com Fax No 847 546 9007 Website www mtiindustries com If Customer Service determines that the unit is defective a Replacement Authorization RA number will be issued No product will be accepted for service or replacement without first obtaining a RA number If authorized return this product to MTI Industries Inc Warranty Dept RA INSERT RA
12. ead Install a 5 amp fuse in the positive circuit Connect the Black wire to the 12 volt Ground 4 Interconnect Wiring Connect Blue wires from each alarm and Yellow wires from each alarm Continue connecting in series Daisy Chain 5 Reconnect the power supply Warm up 10 minutes then test the alarm Only use UL or recognized permanent wire connectors to replace any unit installed with spade connectors or wire nuts OPERATION When the unit is first powered up the CO sensor requires a ten 10 minute initial warm up period to clean the sensor element and achieve stabilization The GREEN LED indicator will flash on and off during the 10 minute warm up period This unit cannot go into a alarm during the warm up period See Test Procedure in this manual After the warm up period the GREEN power ON indicator should glow continuously If the ON indicator light does not light see the section Trouble Shooting Guide in this manual for further information Do not attempt to fix it yourself Brownout Protection The unit can tolerate short power interruptions and brownouts where the circuit voltage drops as low as 1 VDC If the brownout lasts too long the unit will reset and operate as described above LOW POWER OPERATION This alarm will operate normally down to 7 VDC Do not operate this alarm below 7 VDC TEST PROCEDURES A WARNING TO REDUCE THE RISK OF CARBON MONOXIDE POISONING TEST THIS ALARM S OPERATION AFTER THE BOAT HAS
13. m W x 3 1 8 79mm H hole 60 541 M MS drill 1 4 6mm hole for the wires 2 Connect the Red wire to the 12 volt supply Install a 1 amp fuse in the positive circuit Note you must use a separate 1 amp fuse for each alarm Connect the Black wire to the 12 volt Ground 3 Interconnect Wiring Connect Blue wires from each alarm and Yellow wires for each alarm Continue connecting in series Daisy Chain 4 Reconnect the power supply Warm up 10 minutes then test the alarm 65 541 542 MS lack CO Alarm Black gt a 12 volt Battery MODEL M 65 541 M R MS M 65 542 M R MS 1 Model M 65 541 R M 65 542 M R MS With Normally Closed relay This unit supplies a relay with contacts rated12 VDC 3 amp max The relay is energized whenever the alarm is operational It may be used to shut down a generator or to open an optional gas solenoid valve The relay may also be used to interface to alarm systems using either the normally closed or normally open contact depending on the requirements of the alarm system In the event of an alarm the relay will shut off It will automatically re energize after the unsafe levels of CO clears Select a wall location at least 4 off the floor M 65 541 M R MS Cut a 5 5 8 143mm W x 3 1 8 79mm H hole M 65 542 M R MS drill 1 4 6mm hole for the wires 2 Do not connect to an existing installed solenoid SEE SPECIAL WIRING NOTICE 3 Connect Supply to the Red wire l
14. n this manual Test your unit every week Alarms that do not work will not alert you to hazardous levels of CO and need to be replaced See the section Test Procedure in this manual for further information MAKE REGULAR VISUAL INSPECTIONS Check all fuel burning equipment including gas water heaters galley gas stoves space heaters gas dryers and all pilot lights Check the color of the pilot flame The color should be blue MAKE REGULAR VISUAL INSPECTIONS OF THE ENGINE AND GENERATOR EXHAUST SYSTEMS Cracked exhaust systems can allow CO to enter the living area of your boat PROFESSIONALLY MAINTAIN YOUR ENGINE AND GENERATOR Although gas engines and generators produce CO a poorly tuned engine and generator will produce greater amounts CO KEEP THE COCKPIT AND PASSENGER AREA WELL VENTILATED When idling traveling at slow speeds or when the canvas is up at any speed under certain conditions high CO levels can collect in the open air and can enter enclosed areas station wagon effect WHERE TO INSTALL CO ALARMS MTI recommends installing a CO gas alarm in each sleeping area The NFPA and Consumer Product Safety Commission recommends installing a CO alarm outside the sleeping area The 65 Series CO alarm complies with that recommendation INSTALL ALARM at least 4 inches off the floor WHERE NOT TO INSTALL M 65 SERIES ALARMS DO NOT INSTALL behind furniture drapes curtains in closets or areas that will block air flow to the ala
15. rm DO NOT INSTALL within 12 inches 30cm of opening windows hatches exterior doors heating or return vents or other drafty areas DO NOT INSTALL on an outside wall DO NOT INSTALL on a wall switch controlled by a power line ground fault circuit or to a circuit breaker NOTE Older Boats may have little or no insulation and therefore are draftier Carefully consider mounting locations The following diagrams provide additional alarm installation information Galley Sea FIGURE 1 Sleeper Couch CO DETECTOR LOCATION m FORMINIMOM CURE FOR ADDITIONAL SECURITY Do not install within Do not install within 12 of a window that can open Do not instal CL l within 12 of vents Do Not install behind drapes or furniture FIGURE 2 INSTALLATION INSTRUCTIONS A WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT INA MALFUNCTION OR FAILURE OF THE ALARM AND MAY VOID THE WARRANTY SHOCK HAZARD Turn off power before installing Power Supply 12 VDC Recommended Wire Size 14 GA TO 18 GA Connect the alarm to a properly fused circuit maximum over protection device rating 6 amps All connections must be in accordance with the National Electrical Code in the Unites Stated and the Canadian Electric Code in Canada Connect to wiring or circuit that CANNOT be turned off by a switch or ground fault protector Only us
16. roperly ventilated MALFUNCTION SERVICE SIGNAL If any malfunction is detected the Operational CO LED will alternate Red Green and the alarm will sound once every 15 seconds Press the Test Mute button If the Test Mute button does not clear the signals check the battery voltage If the battery voltage is not low and the unit will not return to normal operation immediately remove the alarm and return for service or warranty replacement See the warranty section in this manual OPERATION AUDIBLE SIGNAL VISUAL SIGNAL WARM UP NONE FLASHING GREEN NORMAL NONE STEADY GREEN CO ALARM 4 BEEPS STEADY RED 5 SECONDS OFF ALARM BEEP EVERY ALTERNATING MALFUNCTION 25 SECONDS RED GREEN END OF LIFE BEEPS EVERY RED RED GREEN GREEN SIGNAL 25 30 SECONDS FLASHING MEMORY FEATURE This alarm has a Peak Level Memory feature that remembers the approximate amount of CO that activated it The memory feature does not record brief exposure to CO that would not activate the alarm This alarm will indicate one of four levels with chirps and blinks with the CO LED To activate alarm level memory press the TEST RESET button for less than 1 second 1 Chirp and 1 Green Blink CO memory is clear 2Chirps and 2 Red below 100 ppm 3 Chirps and 3 Red Blinks below 200 ppm 4Chirps and 4 Red Blinks above 200 ppm End of Life Signal The Sensor has a 5 Year In Service Life All 65 Series models include an End of Life EOL Signal indicating the sensor
17. to open an optional gas solenoid valve The relay may also be used to interface to alarm systems using either the normally closed or normally open contact depending on the requirements of the alarm system In the event of an alarm the relay will shut off It will automatically re energize after the unsafe levels of CO clears Select a wall location at least 4 off the floor 60 542 M R Cut a 5 5 8 143mm W x 3 1 8 79mm H hole 60 541 M R drill 1 4 6mm hole for the wires 2 Do not connect to a previously installed solenoid SEE SPECIAL WIRING NOTICE 3 Connect Supply to the Red wire lead Installa5 amp fuse inthe positive circuit Connect the Black wire to the 12 volt Ground 4 Reconnect the power supply Warm up 10 minutes then test the alarm 65 541 542 R Black To Red from 65 541 F 6S S42 R Connect Either White Wire to MODEL M 65 541 M MS M 65 542 M MS 1 Model M 65 541 M 65 542 M MS Multi station interconnect Maximum 10 units and 2000 feet of wire Allows multiple M 65 541 542 MMS alarms to be connected together When one of the alarms detects unsafe levels of CO or gas it will activate It will also activate the audible alarm of all the interconnected units Only the alarm that detected CO or gas will have its Red LED light lit up so that you can determine the cause of the alarm Select a wall location no between 4 and 20 off the floor 60 542 M MS Cut a 5 5 8 143m
18. vent carbon monoxide from reaching the sensor THIS ALARM IS INTENDED FOR USE IN BOATS It does not monitor external deck areas where CO may be present It is not designed to measure compliance with commercial and industrial standards THIS ALARM MAY NOT BE HEARD The alarm s loudness is designed to meet or exceed regulatory standards however the alarm may not be heard if alarms are located in remote locations or behind closed doors or curtains Persons who are hard of hearing have consumed alcoholic beverages taken prescription non prescription or illegal drugs may not hear the alarm DO NOT Install within 5 feet 1 5M of any cooking appliance WARNING TO REDUCE THE RISK OF CARBON MNOXIDE POISONING TEST ALARM OPERATION WHEN NOT IN USE FOR 10 DAYS OR MORE AND BEFORE EACH TRIP THIS ALARM IS DESIGNED TO DETECT CARBON MONOXIDE THE ALARM IS NOT DESIGNED TO DETECT SMOKE OR FIRE THIS ALARM MAY NOT ALARM AT LOW CO LEVELS It is not designed to measure compliance with the Occupational Safety Health Administration OSHA commercial or industrial standards Individuals with medical problems may consider using warning devices which provide audible and visual signals for CO concentrations under 30 ppm SAFECTALERT MARINE CARBON MONOXIDE CO ALARM M 65 Series Surface Mount Models M 65 541 M 65 541 R M 65 541 MS M 65 541 R MS 65 Series Flush Recess Mount Models M 65 542 M 65 542 R M 65 542 MS M 65 542 R MS USER S M
Download Pdf Manuals
Related Search
Related Contents
Installation and Care Guide Betriebsanleitung Geld-Gewinn-Spiel CLIMATISEUR MOBILE Modèle CM 23 T be.ez LA robe MacBook Pro 17 B&W Cómo Utilizar el Lector de DVD DX Series DX-16 - Imagine Communications P:\产品\说明书\User Manual\Word-User Manual\Conference System Vision Fitness X1500 User's Manual Copyright © All rights reserved.
Failed to retrieve file