1. Frequently Asked Questions    MicroFI D Flame Ionization Monitor    In general  any volatile organic compound  VOC  with the following properties is detected by the MicroFI D       Boiling point  lt 185 degrees C    Vapor pressure  gt  1 mm Hg    lonization potential from 8 0 eV to 15 4 eV    For a listing of compounds detected by the MicroFlD  please refer to Technical Tip Volume 7 Number 1  Please note this Technical Tip also provides ionization  potential data for each compound   Learn more   Technical Tip Volume 7 Number 1     Please refer to Photovac   s Technical Tip titled    MicroFlD Flame l onization Monitor Operational Reference Guide    for a walk through of the MicroFID calibration  procedure   Learn more   Technical Tip Volume 3 Number 1     The recommended calibration interval for the MicroFlD is every eight hours of operation    Methane at a concentration of 500 PPM in a balance of ultra zero air is recommended for MicroFID span calibration  A cylinder of 500 PPM methane calibration gas   part number MX396028  can be purchased from Photovac  Inc  Please contact Customer Service at 781 290 0777 to place an order     Photovac recommends that the 0 1 micron filter  part number MX396015  on the MicroFID inlet is changed every forty hours of typical use  During the first few  days of operation the filter should be checked every eight hours of use to determine how quickly the filter becomes dirty or clogged  In dusty environments or  when sampling very high concentra
2. ber 5 for the procedure to determine a response factor   Learn more   Technical Tip Volume 7   Number 5     The data stored in your MicroFID datalogger can be downloaded to a PC for archiving and editing  When downloading data to a PC  Terminal emulation software  must be used  One such available package is Microsoft Windows HyperTerminal  Instructions for downloading logged data into Windows are outlined in Technical  Tips  Please select the Windows operating system below that you are currently using for the appropriate Technical Tip     The message  Detector Cooling  Please Wait  is an indication that the MicroFlD has flamed out but the detector chamber is too warm to allow a controlled restart  of the flame  Turn off the MicroFlD and wait 5 minutes  Try to restart the detector following the instructions in the MicroFID user   s manual  If the MicroFlD does  not restart  perform a cold start on the MicroFID  Please refer to Technical Tip Volume 7  Number 6 for further details on the cold start procedure   Learn  more   Technical Tip Volume 7  Number 6     The brass frit on the MicroFlD should be replaced every twelve months  More frequent replacement may be necessary if humid samples are monitored on a  regular basis     
3. ransportation regulations to ship the MicroFlD with hydrogen in the internal tank  Instructions for emptying the internal  hydrogen tank prior to shipment can be found in Section 5 2 in the MicroFlD User   s Manual     Hydrogen should be transported separately in an appropriate cylinder accompanied by a properly completed Shipper   s Declaration form  Consult your shipping  company for complete instructions     A response factor is a correction factor that normalizes the MicroFlD   s response to a single compound  Since any flame ionization detector can be more or less  sensitive to a single compound  the response factor is used to normalize that unique response relative to methane     Please note  Response factors should only be used where the instrument operator is certain that only a single compound is present  If multiple compounds are  present  the response factor should always be set to 1 0     Since every manufacturer   s detector design is unique  response factors from other manufacturers or other Photovac instruments must not be used with the  MicroFI D  Please refer to Technical Tip Volume 3  Number 2 for a complete listing of the response factors developed for the MicroFIlD   Learn more   Technical Tip       o   a  3  D  w  z     3      D  5  N    If no response factor is listed for a particular compound  Photovac has not developed a response factor of that compound  In this case you can develop your own  response factor  Please refer to Technical Tip Volume 7  Num
4. tions  it may be necessary to check the filter more often  If water or other liquids are aspirated  the filter should be changed  immediately     Hydrogen used to fuel the flame ionization detector in the MicroFlD must be ultra high purity hydrogen  99 999  pure  This grade of hydrogen is also referred to  as Grade 5  The hydrogen must have less than 1 PPM hydrocarbon contamination     You can obtain hydrogen in various size cylinders  Regardless of the cylinder size  the cylinder must have a fill pressure of at least 1800 psig in order to  completely fill the MicroFlD internal cylinder  The tank should have no more than 2400 psig  The hydrogen cylinder must also have CGA 350  male outlet for  connection to the MicroFID refill adapter  part number MX396004      Please note  The refill adapter is shipped as standard equipment with the instrument  You cannot fill the internal MicroFlD hydrogen tank without the refill  adapter     The MicroFlD should not be stored in its carrying case  part number MX396007   in its original shipping container or any container which is unventilated if the  MicroFID is FULLY OR PARTIALLY CHARGED WITH HYDROGEN GAS  MicroFIDs and all portable flame ionization instruments should always be stored in a well   ventilated area when charged with hydrogen  For further details on hydrogen safety  please refer to Technical Tip Volume 3  Number 5   Learn more   Technical Tip    g  o     3  D  Ww  z     3  o  oO  S        It is illegal under US Department of T
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
+ Infos Xerox - Top Edge Engineering  Roland Recorder CD-2e User's Manual  Samsung Màn hình LED 19" với thiết kế đen bóng Hướng dẫn sử dụng  Sony 4-178-247-13(2) User's Manual  添付文書:90848328-01A - Boston Scientific  LiftMaster 412HM User's Manual  Dynex 2-Outlet Quick Setup Guide  Renkforce E-SA9M User's Manual    Tese 6,8 MB - Técnico Lisboa    Copyright © All rights reserved. 
   Failed to retrieve file