Home

(Ver A) Universal Homecare Bed Manual (Ver A)

image

Contents

1. G0500007REVCO7 5 ASSEMBLY INSTRUCTIONS BED END ASSEMBLY FIGURE 7 FIGURE 8 COMPLETED ASSEMBLY e On full electric models first compress and secure motor extension before assembly e Standing directly in front of the bed end position it as close to the bed as possible e With one hand reach over end and lift up bed e Tilt the bed end slightly back toward you e Engage lower rivet slightly and tilt end toward bed e Lower bed into corner lock e Repeat for head end G0500007REVCO7 6 ASSEMBLY INSTRUCTIONS CONT DRIVE SHAFT ASSEMBLY e The drive shaft is comprised of two sections inner and outer tubes e Depress spring button and insert until desired hole 1s reached determined by which bed manual or electric hi lo Outer Tube Spring Button FULL ELECTRIC FIGURE 9 G0500007REVCO7 7 ASSEMBLY INSTRUCTIONS CONT DRIVE SHAFT ASSEMBLY HEAD END GEARBOX s w 6 EEE a r C DRIVE SHAFT ASSEMBLY e Connect the drive shaft assembly to the bed by first attaching either side of drive shaft to the foot end gearbox Then attach other end to head end gearbox G0500007REVC07 8 ASSEMBLY INSTRUCTIONS CONT FULL ELECTRIC HI LO SLIDE IN AND ROTATE TO COUPLER ROTATE TO UNLOCK e z TES UNLOCKING COUPLER GEARBOX e On electric hi lo model beds only Release the spring loaded coupler by gently rotating it clockwise until coupler engages with gearbox COUPLER G050000
2. PIN STORAGE POSITION 72 HANDLE POSITION STORAGE AND OPERATING OPERATION e Remove clevis pin and move handle to operating position then reinsert clevis The crank is now ready to operate e To store bed reverse instructions above G0500007REVC07 13 BED OPERATION CONT TRENDELENBERG POSITION e Lower bed to its lowest height Disengage the hi lo drive shaft by compressing the spring fitting and removing the drive shaft from the motor or bed end e Raise the foot bed end using the hand pendant or crank The head end will remain in the low position REVERSE TRENDELENBERG e Raise bed to its highest height Disengage the hi lo drive shaft by compressing the spring fitting and removing the drive shaft from the motor or bed end e Lower foot bed end using the hand pendant or crank The head end will remain in the high position G0500007REVCO7 14 SPECIFICATIONS DECK HEIGHT BED HEIGHT HIGH POSITION BED HEIGHT LOW POSITION LENGTH DECK WIDTH G0500007REVCO7 15 SPECIFICATIONS CONT ELECTRICAL e UL 73 CSA approved e MOTORS e 1 10 Hp 115VIts 60Hz 1 6 amps WEIGHT e Normal operating conditions 450 Ibs evenly distributed CONSTRUCTION e Frame l0ga 135 high strength low alloy steel Roll formed e Sleeping surface 11ga 120 cold rolled steel FINISH e 5 stage bath e 1 S21F acid bath cleans grease and oil from metal e 2 Fresh water rinse e 3 QuiliPhos 20 phosphate
3. 7REVCO7 9 BED OPERATION PENDANT Shown for Models SD0100A SD0105A SD0204A Lower Head Raise Head Lower Bed Raise Bed Lower Foot Raise Foot e Check all J box connections and plug power cord into a properly grounded outlet 110volt 60 Hz e Inthe event of a power failure the emergency crank provided can be used to adjust the head hi lo and foot sections of the bed e NOTE Semi Electric pendant does not have bed height adjustment hi lo functions G0500007REVC07 10 BED OPERATION CONT JUNCTION BOXES Shown for Models SD0100A SD0105A amp SD0204A POWER __ 7 PENDANT Font HI LO HEAD FULL ELECTRIC JUNCTION BOX PRES i POWER PENDANT SEMI ELECTRIC JUNCTION BOX G0500007REVC07 11 BED OPERATION CONT MANUAL CRANK BED CRANK HEAD CRANK FOOT CRANK To raise bed Turn the center crank e 70 lower bed Turn the center crank handle clockwise handle counter clockwise To raise headspring section Turn the e To lower head spring section Turn left hand crank handle clockwise the left hand crank handle counter To raise foot spring section Turn the clockwise r ght hand crank handle clockwise e 70 lower foot spring section Turn the right hand crank handle counter clockwise G0500007REVC07 12 BED OPERATION CONT MANUAL CRANK cont Note After unpacking bed remove handles from sleeping surface and attach as shown below CLEVIS
4. EATED IN THE BED END HOOKS OTHERWISE INJURY OR DAMAGE MAY RESULT KEEP ALL MOVING PARTS FREE OF OBSTRUCTIONS I E BLANKETS SHEETS HEATING BLANKETS PADS TUBING WIRING AND OTHER TYPES OF PRODUCTS G0500007REVC07 1 ASSEMBLY INSTRUCTIONS FOR HOMECARE BED FOOT SECTION Figure 1 NOTE spring fabric not shown for clarity e Lay the head and foot section on their sides approximately 90 to each other See Figure 1 e Slide the sections together until the hook on the foot section catches the rivet on the head section G0500007REVC07 2 ASSEMBLY INSTRUCTIONS CONT Figure 2 e Straighten sections and position as shown in figure 2 e Position head wing as shown SPRING CLIPS FOOT FABRIC HEAD Figure3 WING e Attach fabric halves together using spring clips which are attached to the foot fabric See Figure 3 G0500007REVCO7 3 ASSEMBLY INSTRUCTIONS CONT HEAD TUBE LANYARD PIN ASSEMBL Figure4 Note Insert clevis pin thru extension tube and into pivot lever Install washer and attach cotter pin See Fig 4 G0500007REVCO7 4 ASSEMBLY INSTRUCTIONS CONT HEAD END CASTER ASSEMBLY SWIVEL LOCKING Figure5 FOOT END e Insert casters in bed ends by lining up caster shaft with hole in bottom of bed end legs and gently pressing in until secured The two locking casters should be placed where accessible preferably at opposite corners of the bed See Figure 5
5. LLINIEX For The Quality Of Life Homecare Bed GER Fin a EF i sc gt GRAHAM FIELD HEALTH PRODUCTS G0500007REVC07 ZA WARNING ZA WARNING ZA WARNING ZA WARNING ZA CAUTION N CAUTION N CAUTION N CAUTION N CAUTION N CAUTION WARNING CAUTION SUMMARY KEEP HANDS AND FEET CLEAR OF ALL MOVING PARTS DO NOT ALLOW SMALL CHILDREN ON OR NEAR BED DURING OPERATION DO NOT ALLOW THIS DEVICE TO BE OPERATED BY SMALL CHILDREN WHEN OPERATING THE HI LO KNEE OR BACK FUNCTION OF THE BED ALWAYS ENSURE THAT THE INDIVIDUAL CONFINED TO THE BED IS POSITIONED PROPERLY WITHIN THE CONFINES OF THE BED DO NOT LET ANY EXTREMITIES PROTRUDE OVER THE SIDE OR BETWEEN THE BED RAILS WHEN PERFORMING ANY FUNCTIONS DO NOT USE UNAUTHORIZED SIDE RAILS WARNING CAUTION LABELS APPLIED TO THE BED OUTLINE HAZARDS OR UNSAFE PRACTICES THAT COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE PENDANT CORD MUST BE ROUTED AND SECURED PROPERLY TO ENSURE THAT CORD DOES NOT BECOME ENTANGLED AND EVENTUALLY SEVERED DURING USE MAKE SURE ELECTRIC CORDS DO NOT GET TANGLED AROUND THE BED SIDE RAILS OR LEGS DURING NORMAL OPERATION OF THE BED WHEN USING NASAL OR MASKED TYPE ADMINISTERING EQUIPMENT OXYGEN OR AIR TUBING MUST BE ROUTED AND SECURED PROPERLY TO ENSURE THAT TUBING DOES NOT BECOME ENTANGLED AND EVENTUALLY SEVERED DURING NORMAL OPERATION OF BED BEFORE OPERATING INSURE THAT THE BED FRAME RIVETS ARE PROPERLY S
6. ake sure all plugs are fully inserted or attached Bed frame and sleeping surface Visually check all welds Head section Knee section Main Frame Check joints between sleeping surface sections for loose fasteners Cleaning The metal parts of the bed are covered with a baked epoxy coating Clean all coated parts with mild detergent and warm water Periodically raise head and feet sections of the bed and remove dust from frame Also periodically remove mattress and clean mattress deck Lubrication and Mechanical Lightly grease all actuator screw threads with white lithium grease Lubricate all caster roller and swivel bearings with light machine oil Check all bolts and tighten as needed WARRANTY Two year warranty for defects in workmanship and materials of mechanical components frame and electronics During the warranty period defective items will be repaired or replaced at manufacturer s option at no charge G0500007 REVCO7 19 U S A Corporate Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 G0500007REVC07 http www grahamfield com
7. coat inhibits rust and helps maintain electrical charge during powder application e 4 Fresh water rinse e 5 QuiliRinse 404 seals metal for powder coating e All parts are then coated with a colored epoxy powder and baked 35 minutes at 375 degrees The powder coating finish is to be approximately 2 5 mils thick The coating will be a smooth uniform finish without runs wrinkles or grit G0500007REVCO7 16 Universal Bed Replacement Parts 3a 3b 4a 4b 9 d 11b 11c N 2 4a 4b em b Bed End Capping Brown 2 Ea lla Foot Section Assy Full Elec Hi Lo Rod Manual Extension Tube Square 14a 600 4100 901 Head Section Assy G0500007REVCO7 17 Universal Bed Electronics Replacement Parts Bed Models SD0105A SD0204A Bed Models SD0105N SD0204N Item Description 1 2 4 5 7 27 600 0666 913 Foot Motor Assem Univ N G0500007REVCO7 18 EE 2 __ BET 35 2 2 2 2 2 2 2 MAINTENANCE AND SAFETY CHECKS Once per vear or between patient placements ELECTRONICS Check all controls to make sure all functions work properly Foot control Head control Hi Lo if applicable Check all cables for damaged or frayed wires Power cord Foot actuator wire Head actuator wire Hi Lo actuator wire Pendant cord Check to make sure all wires are routed and attached properly so they do not interfere with any moving parts Check to m