Home

RC Duo 2 - Walker Industrial

image

Contents

1. 0 o gojo o o 0 000 I E oai ee Ensure remote is powered on section 2 and sensor is in confi te mode section The sensor s ad dress illuminates on the keypad EXAMPLE address The new setting is im mediately saved and displayed on the key set value by illumina EXAMPLE mounting EXAMPLE 10 13 ft pad ting it on the keypad height F4 3 0 3 9 m 3 1 factory default EXAMPLE Programming of this ON blinks hes Press F immediately 4 13 16 ft 4 4 9 m Press parameter is now ee establis followed by factory default complete Repeat for o other parameters Note If any keys are blinking programming failed In this case repeat programming Page 1 RB Additional functions SN LED indicator On Continuously Safety curtain spot detected Blinking Low battery Safety curtain spot detected AND low battery EYJ Beeper function Remote must be turned on to access beeper function BEEPER ON Press and hold B for 2 seconds BEEPER OFF Press and hold B for 2 seconds Beeper function turns off when remote turns off This setting must be re activated each time the remote is turned on Sensor scan mode Use sensor scan mode to determine available sensor addresses The active address is now All addresses assigned to illuminated on the keypad sensors in proximity are illu minated on the keypad Select the corresponding ad dress to establis
2. EN ISO BIRCHER Reglomat C D UO 2 Bidirectional remote control HEM General information ERE Parts of the remote 9001 Quality international eve Transmitter receiver infrared Status indicator LED safety curtain infrared spot detector Numerical keys 1 to 9 2 5 cm spacing for safety curtain infrared spot finder Function keys A to F Start button power on 2 sec amp establish connection Battery compartment Battery compartment cover Quick reference guides stored in slot on battery compartment cover o 0 gt el l zilol mn mlolo w gt EFJ Shortcut buttons VO On Yes only for certain parameters X Off No only for certain parameters Turns beeper function on off hold for 2 sec A F Scans for available addresses sensors hold for 2 sec IE Turning on the remote The RC Duo 2 must be powered on before it can communicate with the sensor POWER ON Press and hold G for 2 seconds POWER OFF Press and hold G for 2 seconds The remote will automatically turn off after 2 minutes if no button is pressed Communication with the sensor Establishing connection with the sensor Once the remote has been powered on G will illuminate in red and begin to blink To establish a connection with a particular
3. h communi cation with a specific sensor Press F for 2 seconds to enter sensor scan mode EYY Safety curtain spot detector Use the 2 width mark on the RC Duo 2 to determine e g when the infrared safety curtain is 2 from the face of a sliding door Status Display Beeper function if turned on see section 4 2 No Safety curtain spot detected Green No beeping 4 Safety curtain spot detected Red Constant beeping ie A 2 5cm BW Safety instructions A N Only use this remote for it s intended purpose Do not point the IR beam towards your eyes or those of others Observe all national and international door safety regulations Only trained qualified personnel may install sensors This unit may only be opened and repaired by Bircher Reglomat Always consider the safety functions of your DE as a whole never just in relation to one individual section of the system The installer is responsible for carrying out a risk assessment and installing sensors and door systems correctly WW Technical data Technology Active infrared 40 kHz Max air humidity 90 non condensing Operating temperature 20 C to 40 C Batteries 3 AAA 1 5 V batteries Declaration of conformity Manufacturer Bircher Reglomat AG Wiesengasse 20 CH 8222 Beringen Switzerland www bircher reglomat com Importer Bircher America Inc 870 Pratt Ave N Schaumburg IL 60193 USA ww
4. sensor aim at the sensor and pess The sensor s address 1 7 will illuminate on the keypad The sensor s LED will briefly illuminate to confirm U RC Duo 2 is now ready to program the sensor For help in selecting a particular sensor out of several see section 4 3 sensor scan mode The connection between the RC Duo 2 remote control and the sensor can only be established while the sensor is in configuration mode Configuration mode is activated when the sensor is switched on For safety reasons this mode is exited automatically 30 minutes after the last setting has been made and the connection between the remote control and the sensor is interrupted The connection can be re established in one the following ways IN Pressing a button on the sensor OR Interrupting the electrical power supply to the sensor OR Using the access code function on the remote control only available on some sensor models Please refer to the sensor user manual for more information Setting sensor parameters The RC Duo 2 functions bidirectionally with the sensor This means that changes to the settings on the sensor are immediately signalled back SING sensor to the remote control EXAMPLE the steps for setting the Hercules sensor mounting height parameter F4 are shown below A heed o1oo 0 I I I I To address the desired The sensor ack Now press desired parameter nowledges it s current new value i I I I I I I 0 0 0
5. w bircherreglomat com Standards taken into account EN 61000 6 2 EN 61000 6 3 Important note Bircher Reglomat reserves the right to change any information in this document without notice For the latest version please visit www bircherreglomat com or call 800 252 1272 to request a copy BIRCHER Reglomat B Bircher Reglomat Wani B 870 Pratt Avenue N ember ge member Schaumburg IL 60193 Phone 847 952 3730 Toll Free 800 252 1272 Fax 847 952 2005 E E th rt peta S T Email sales bircherreglomat com association Web www bircherreglomat com Page 2 05 12 US01 006