1505 – Birthing Bed
Contents
1. HEALTHCARE 1505 Birthing Bed User s Manual Index 10 Introduction About this Product Definitions Safety Environmental Specifications Installation Optional Accessories Operation Maintenance amp Cleaning Warranty amp Service 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 13 13 21 INTRODUCTION Aboutthis User Manual This User Manual contains instructions for the proper and safe use of Manually operated Birthing Bed and for patient amp user safety and comfort which has to be strictly followed This User Manual has to be read and followed by every person using or handling this Bed In case of any query kindly contact Janak Healthcare Pvt Ltd ABOUT THIS PRODUCT e These Manual Birthing Beds are non invasive medical devices having multipurpose use for obstetrics gynaec examination and post delivery recuperation if used as a Bed of the patient by medical paramedical hospital personnel to help and support the patient in diagnosis prevention monitoring treatment or alleviation of the disease For Obstetrics there is telescopic leg section which slides underneath the top frame This helps the patient to attain the lithotomic position and easy access for the obstetrician to take delivery near the pelvic region e These Birthing Beds are patient support and patient rest facility which help medical personnel in carrying out heir medical procedu
2. Date 14th June 2014 Safety Instructions Always use original accessories that have been designed and approved for use with the Manual Birthing Bed Ensure that the Bed is assembled and installed in accordance with the instructions given in this User Manual Restrict child visitors without proper attendants Supervision is necessary to avoid any mishap due to unintended movement ofthe Manual Birthing Bed Persons with reduced physical or mental abilities amp children must not be allowed to use amp handle the Manual Birthing Bed without proper supervision Do not allow any visitor to sit on the Manual Birthing Bed as it may cause overloading Refer section Operation Accessories or any devices used along with the Manual Birthing Bed should be as per its intended use specified and approved by Janak Healthcare Pvt Ltd The Manual Birthing Bed should always be kept and used in normal indoor hospital environment Do not keep any articles below the bed main frame It can damage the Linkages and Screw mechanisms Ensure that the Manual Birthing Bed is moved on a smooth stepless floor without any obstructions in its path to prevent any damage to the undercarriage ofthe bed Keep some gap between walls and Manual Birthing Bed while in stationary position and also while moving from one place to another Keep the User Manual handy with the Operator User for ready reference Always use a mattress of the correct size and ty
3. 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Hand Grips Hand Grips e Hand grips are fitted at both left hand amp right hand side of the birthing bed main frame Lithotomy Crutches Lithotomy Crutches e Adjustable swiveling crutches come ready fitted to the rod Insert the lithotomy crutches rod in the provision given on mainframe of the bed Tighten the rod as shown in picture Height of lithotomy crutch can be adjusted at any desired level using the handle 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Foot Support Foot Support High For low and high comfortable chair positions during labour pain two pairs of foot support are provided To fix the Low High Foot Rest insertthem in the location shown above provided in the Leg End Telescopic Section With due consideration to environmental limitations materials used to make the device are not affected by A contact with any bio chemicals or bio waste When used as per its intended purpose all materials used in the product and accessories do not facilitate any breeding or growth of bio contaminants on their own 12 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 MAINTENANCE amp CLEANING Maintenance Each time before putting the Bed into service the user must check that e All the functions are in satisfactory working conditi
4. a period specified in the warranty certificate such product shall perform as per its intended use The foregoing warranties shall not apply if the Product has been subjected to a physical abuse misuse abnormal use or use not consistent with Janak Healthcare Pvt Ltd s published directions b any modification by anyone other than Janak Healthcare Pvt Ltd or third parties designated by Janak Healthcare Pvt Ltd or c fraud tampering negligence or accidents depending upon the nature of the products Limitation Of Liability In no event shall Janak Healthcare Pvt Ltd be liable or obligated to the end user in any manner for any special non compensatory consequential indirect incidental statutory or punitive damages of any kind including without limitation for injury or loss of life lost profits lost sales lost revenue loss of any software or data or loss of use of any hardware software or data regardless of the form of action whether in contract tort negligence strict product liability or otherwise even if Janak Healthcare Pvt Ltd has been informed of or is aware of the possibility of any such damages in advance Janak Healthcare Pvt Ltd s total aggregate liability under this agreement and in relation to anything which Janak Healthcare Pvt Ltd has done or not done in connection with this agreement shall be limited to the price of the products purchased and paid for by the end user during the period in which such liab
5. c Pressure 800 to 1060 hPa Altitude lt 2000m INSTALLATION 1 Unpack all the components carefully 2 Ifthe packing is drenched by rain water or other liquids inform this matter to the operator 3 Each Manual Birthing Bed is supplied with the following components as per packing list Bed fitted with castors Mattress Telescopic Leg End Extension Hand Support with Grip and Stainless Steel Tray 1No Rubber Buffer with bush 4Nos Stainless Steel Head amp Foot Board Product specific 2Nos Safety Side Railings Product Specific 1 Pair Lithotomy Crutches Foot Rest Upper Foot Rest Lower 1 Set Polymer Moulded Handle 1No Notify if any damage has occurred during transportation either to the authorized agent or directly to Janak Healthcare Pvt Ltd A Installation ofthe Bed should be done only by Janak Healthcare Pvt Ltd trained technicians 4 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Buffers e Fixtherubber buffer in the buffer holder with bush and bolt at all 4 corners as shown above Head amp Foot Boards e Insert the head end and leg end bows 1 fitted with laminated panels in its brackets 2 at head end and leg end respectively by extending equal forces with both the hands in the bracket as shown above 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 1 V Pole Insert the Telescopic I V Pole in
6. e clinic hospital management etc who will be responsible for the safe operation of this Manual Birthing Bed User User is a person who is capable of assessing clinical condition of patient e g specialist medical personnel doctors nursing staff attendants etc On the basis of their training experience or through the instructions they are entitled to operate the Manual Birthing Bed on their own responsibility or to carry out work on it and are able to recognize and control possible risks to the patient as well as the Manual Birthing Bed Patient The patient is a person who is ill infirm disabled or in need of care amp occupying this Manual Birthing Bed Each time the Manual Birthing Bed is allotted to a new patient it is recommended that the patient is instructed by the operator or the user about the functions important for his her comfort and safety SAFETY In this User Manual the following safety symbols are used Danger This symbol will appear wherever safety instructions are designed to protect people from physical harm The symbol stands for imminent danger of death or serious injury Caution This symbol will appear where situations are described which might be dangerous and which might inflict slight injuries CT Advice This symbol will appear in front of additional helpful pieces of advice A dotin front of the text implies the action that is required to be taken 1505 Birthing Bed UserManual Rev No 0
7. e com
8. elves if they get entrapped A Do not use the Safety Side Railing to lift or move the Manual Birthing Bed di Users should carefully evaluate the need for safety side rails and periodically check patients in accordance with facility protocols for safe positioning 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 The Safety Side Railings should always be in raised position when attaining lowest height position orwhen To facilitate and allow the gynaec delivery and post delivery procedures on patients this Birthing Bed is A attaining Trendelenburg Reverse Trendelenburg tilt positions specially provided with telescopic leg section and lithotomy crutches due to which the safety side rails near leg section are not provided In absence of safety side railings near leg section user discretion and supervision is advised for patients using the Birthing Bed for post delivery resting purpose A If these safety measures are not observed injuries can be caused to hands knees fingers feet legs or other body parts of patient due to unintended entrapment Adjustment of Telescoped Leg End Section To operate the leg end section Remove the Leg End Mattress and place itin a safe place Remove the Leg Bow and place itin a safe place Pull up the Leg End Telescopic frame and slide it inside the main frame For extending the Leg End Telescopic frame follow the above three steps in reverse order
9. endelenburg Head down position as shown above Castors amp Braking Mechanism The Manual Birthing Bed is equipped with four 125 mm High Grade Synthetic Castors two diagonally opposite castors are with brakes To lock the Castors movements press the latch and to unlock release the latch 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Head amp Foot Boards The Head and Foot Board are located at the head and foot end of the Bed frame The Head and Foot Board can be removed or attached in a single step by extending equal force with both the hands in the bracket by ensuring the proper matching of the brackets with board holder fitted in the main frame e The Head and Foot Boards can be removed for ease of access to the patient from head and foot side Donothang any heavy items on the Head and Foot Boards Safety Side Railings To use the Safety Side Railings Immobilize the Manual Birthing Bed Fix the railing in the specific slot provided on the main frame Please take care of finger and hand entrapment while operating the Safety Side Railings Although the safety side railings have been designed to reduce the risk of patient injury the potential exists for patient entrapment particularly in agitated or disoriented patients patients who have cognitive disability or have uncontrolled body movement as well as patients who lack the physical strength to extract thems
10. ility arises The limitations set forth above shall be deemed to apply to the maximum extent permitted by applicable law and notwithstanding the failure of the essential purpose of any limited remedies In order to maintain functional safety and right to claim under the warranty only original replacements parts may be used For ordering replacement parts customer service request and further question please contact our technical support department MANUFACTURER S ADDRESS Corporate Office Janak Healthcare Pvt Ltd Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com Registered Office Janak Healthcare Pvt Ltd Janak House Opp Indian Oil Corp Depot Sheikh Misry Road Wadala E Mumbai 400037 Tel 91 22 2412 0171 2413 0407 Fax 91 22 2413 9870 Toll Free No 1800 22 8020 Email technicalsupport janakhealthcare com ce 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 17 Notes 18 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 2 JANAK EALTHCARE JANAK HEALTHCARE PVT LTD Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcar
11. its provisions 1 one on each side on the long side of the main frame of birthing bed at head end as shown above A Dispose the packing material waste in accordance with the local waste disposal regulations prevailing OPERATION Before putting the Manual Birthing Bed into use for the first time ensure that all the transport securing devices and packing film are removed Clean and disinfect the Manual Birthing Bed prior to the first time use The Manual Birthing Bed should be used on a flat floor The force required to move the Manual Birthing Bed from one place to another with without patient may vary depending on the flooring conditions Check if all the operations are functioning properly This Manual Birthing Bed should be operated only by an authorized and trained person who has knowledge of its operation A Do not load the Bed more than the Safe Working Load as mentioned above 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Adjusting the Backrest Section e The backrest can be lowered amp raised as desired with the help of screw mechanism provided at the head end Adjusting the Height e The height can be lowered amp raised as desired with the help of pedal fixed on the hydraulic pump 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Adjusting the Trendelenburg Position Rotate the handle provided to attain Tr
12. must not contain any substances which bring about any change in the structure or adhesive property ofthe plastic The Manual Birthing Bed should be properly cleaned and disinfected to avoid infection and stains before allotmentto a new patient anual Birthing Bed 8 remove all the detachable accessories and components before cleaning Any prolonged contact of urine or acid on mild steel can corrode the surface Keep the surface dry at Wearing suitable protective clothing clean the surface with a disposable cloth soaked in a neutral detergent and hot water We recommend use of approved disinfectant and cleaning agents to clean the Manual Birthing Bed e g Bacillocid or other similar agents Start by cleaning the upper sections of the Manual Birthing Bed amp work along all horizontal surfaces Work methodically towards the lower sections of the Bed Take extra care to clean areas that may trap dust or dirt All detachable accessories and its component can be cleaned separately Do not expo se the Manual Birthing Bed to excessive moisture as corrosion may cause personal injury or equipment damage Disposal Product and its defective parts especially elements made of plastic steel and rubber material should be disposed off in accordance with the statutory rules and regulations prevailing for such disposal The user is advised to contact Janak Healthcare Pvt Ltd for further assistance 1505 Birthing Bed UserManual Rev N
13. o 0 Date 14th June 2014 JANAK HEALTHCARE Routine Inspection Check List Inspection by the User Recommended Frequency Every new allotment but not later than one month Checks Observation OK NotOK Description of faults Visual check of the mechanical components Main Frame Damage Deformation Sliding Leg Section Smooth movement Mattress Damage Side Railing Locking Un locking Secure fastening Screws and Rivets Loosened Missing Performance check of mechanical components Detachable Lithotomy Crutches Secure retention Detachable Head amp Foot Boards Secure retention Castors Locking Release mobilization Safety Side Railings Locking Un locking Secure fastening Sliding Legrest Engagement Accessories Fastening Damage Missing Sign Result of inspection Date 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Troubleshooting Guide Problem Possible Causes Remedy Height Function not e Hydraulic pump failure e Repair or replace hydraulic pump working e Foot pedal loose damaged e Tighten the foot pedal or replace Tilt function amp Backrest e Screw mechanism broken Repair or replace screw not working damaged mechanism 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 WARRANTY amp SERVICE Janak Healthcare Pvt Ltd warrants solely to the end users of this product that for
14. on before the Manual Birthing Bed is allotted to the next patient e Lubrication of all the mechanical joints pins moving parts tightening of the bolts should be carried ou east once in three months to avoid unnecessary sound and wear amp tear of the Manual Birthing Bed e At regular intervals carry out a visual inspection and check for any mechanical damage e g loose missing rivets screws etc any damage or malfunction is observed immediately report this matter to the operator the Manual Birthing Bed is not in use it should be stored in a dry and rodent free indoor environment on a surface with gradient not more than 5 degrees the Manual Birthing Bed is not in use for long term it is necessary to conduct a test to check for functioning and any mechanical damage that may have been caused at e Depending on the usage certain moving parts may require replacement due to wear amp tear We recommend imely replacement with original spares for safety and trouble free operation 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 Cleaning amp Disinfecting The Manual Birth Do not use water agents The cleaning ag Immobilize the all times ing Bed is not suitable for machine wash or steam cleaning jetfor cleaning he Manual Birthing Bed cannot tolerate the influence of strong solvent basic or alkaline liquids amp caustic ents
15. pe with this bed Before operating the Bed make sure the patient is safely positioned on the mattress to avoid any inadvertent entrapment or imbalance Janak Healthcare Pvt Ltd recommends the use of original Mattresses that have been designed amp tested specifically for this Manual Birthing Bed Also ensure that the dimensions amp construction of Mattress should minimize gaps where entrapment could occur The shape and height of Head and Side Railings is optimized to provide patient safety from accidental roll over at the same time facilitating the User to provide easy access for treatment and assistance to the patient f Mattress impermeability could be affected by needle sticks Users should be instructed to avoid punctures caused by improper use of needle sticks Failure to do so could result in cross infection amp patient injury The mattress should be regularly inspected for punctures rips tears or other such damage amp replace with suitable mattress if required N Patients should not be allowed to smoke while on Obstetric Labour Table as it may cause fire hazard and personal injury or equipment damage could occur Mattress sheets amp pillows generally do not have flame retardant properties 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 ENVIRONMENTAL SPECIFICATIONS Usage Storage and Transport Temperature 10 C to 50 C Relative Humidity 0 to 95 non condensing Atmospheri
16. res comfortably minimizing the risks while moving and handling the patient e These Birthing Beds are manufactured and supplied in non sterile condition for use in normal hospital environment e These Birthing Beds are mechanically operated for certain profiling movements to achieve clinical positions with the help of screw mechanism e These Birthing Beds are not diagnostic measuring monitoring or a therapeutic device or we say that it can prevent or alleviate disease e These Birthing Beds are also useful for intensive care critical care in hospitals and nursing homes Manual Birthing Bed Features Ce Please refer 1505 catalogue for salient features of this product Technical Data LE Please refer 1505 catalogue for Technical Data ofthis product Optional Accessories Ea Please refer 1505 catalogue for various accessories available and compatible with this product 1505 Birthing Bed UserManual Rev No 0 Date 14th June 2014 1505 Manual Birthing Bed In this Manual Birthing Bed there are TWO screw mechanisms used to attain the clinical positions of Backrest and Trendelenburg amp Reverse Trendelenburg Tilt The Height Adjustment is achieved through a hydraulic pump and pump pedal This Manual Birthing Bed is available with Safety Side Railings and 125 mm high grade synthetic castors and handle for operating screw mechanism DEFINITIONS Operator Operator is the person appointed by the owner i
Download Pdf Manuals
Related Search
Related Contents
PARAMENIDES: - Karl Cassar High Definition Digital Video Camera User Manual herunterladen Toshiba Portégé Z20t-B2112 取扱説明書[DC-2ECA/3ECAシリーズ] (2.26 MB/PDF) UltraSeal XT® plus - Åhrén Dental Consult Yann Boucher RECOMENDACIONES MANUAL DE INSTALACION, USO Y Remington R-91 User's Manual Sun SPARC Enterprise T5140 and T5240 Servers Installation Guide Copyright © All rights reserved.