Home

03720-800-DU002-A User Manual Minilys

image

Contents

1. 06404 800 DU002 A bertin a TECHNOLOGIES This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 7 2 Replacing Spare Parts This paragraph lists the maintenance actions to be done by user on a regular basis to ensure MINILYS runs properly Wearing parts are Wearing parts Reference NOUS Why replacement 06404 810 NC004 6 months or to Necessary to maintain tubes during destruction homogenisation 06404 810 NC005 6 months or to Necessary to maintain tubes during destruction homogenisation 06404 810 NC001 1 year or to Necessary to maintain tubes during destruction homogenisation 7 2 1 Replacing Tube Blocking Rod The tube blocking rod can show signs of wear over time It should be replaced at least once every year 7 2 2 Replacing Fuse A scew driver is required to replace the fuse WARNING Turn off the system and unplug power cord before replacing the fuse L ne Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 22 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 7 3 Service Menu 7 3 1 Firmware Version By pressing the Stop button while switching ON the unit the screen displays the firmware version To return into the main status the user must press Start or
2. around air outlets for proper motor ventilation 3 Plug the MINILYS into the power supply using a compatible power cord WARNING This equipment must be powered from a main supply which has a protective ground terminal E o Ref 06404 800 DU002 A bertin my TECHNOLOGIES Page 13 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 5 Instructions for Use 5 1 Preparing Samples The samples have to be prepared in the tubes recommended by Bertin Technologies see 2 3 WARNING Each tube has to be filled with 1 4 ml of the sample 5 2 Starting a Run 5 2 1 Turning the equipment ON Turn ON the MINILYS by pressing the ON OFF button located on the rear panel near the AC power input 5 2 2 Starting Information When the unit is turned on the LCD screen and the speed light indicate the parameters of the last cycle operated WARNING Do not start the equipment without at least one tube and his appropriate holder 5 2 3 Opening the Cover WARNING Never open the cover while the unit is running Ref 06404 800 DU002 A bertin Page 14 23 TECHNOLOGIES age This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies To open the cover use the hole under the sticker Minilys and raise the cover until
3. displayed on the screen and the light is flashing red To return into the main status the user must press Start or Stop button Actions to be done in case of alarm are described in 6 3 6 2 2 Err Alarm The message Err is displayed on the screen and the light is flashing red to indicate several dysfunctions gt The engine cant start electric or mechanical issue gt The speed of the engine is too high electrical or sensor issue gt The temperature is too high intensive use Ref 06404 800 DU002 A be rt IN Page 19 23 TECHNOLOGIES This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies To return into the main status the user must press Start or Stop button Actions to be done in case of alarm are described in 6 3 Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 20 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 6 3 What to Do When an Alarm Message Occurs seo 1 Check that nothing prevents the cover from closing The cover is not locked properly 2 Press cover and ensure the handle is locked properly Detecti eal Turn off the unit etection system 1s fau y y 2 Contact technical assistance Check that the voltage on the back of the Power s
4. of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 5 2 6 Closing the Cover Close the cover just by putting it in low position 5 2 7 Adjusting the Duration of the cycle 66 JJ The user can change the cycle s duration using the and buttons of the Time area The cycle s duration ranges from 5 seconds to 240 seconds in increments of 1 second If the user holds the button or the increment speed rises 5 2 8 Adjusting the Speed The user can change the speed value using the and are 3 speeds pre programmed in the display gt Speed 1 left light corresponding to 3 000 rom gt Speed 2 central light corresponding to 4 000 rpm gt Speed 3 right light corresponding to 5 000 rpm 66 99 buttons of the Speed area There 5 2 9 Running a Program When the parameters of the run have been set the lysing starts by pressing the Start button During the cycle a timer in seconds counts down the remaining time before the end of the cycle The status light is flashing green WARNING Never open the cover while the unit is running 5 2 10 Ending a Run At the end of a run the holder is stopped and the unit displays the duration and the speed of the ended run The status light is green WARNING Wait until the complete stop of the unit before opening the cover Ref 06404 800 DU
5. on The keypad see diagram below consists of a 3 digits LCD screen 6 buttons and 4 lights 3 lights for the speed 1 light green or red for the status of the equipment The LCD screen and the speed light indicate the parameters of the last cycle operated T ao Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 8 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies Screen Time setup me Speed setup me Start Validation button Speed 3 Speed 2 Speed 1 Stop Cancel button Status light Green light ready to start Flashing green in progress Flashing red error Orange light number of cycles The user can adjust the different homogenization settings see 5 with this interface Buttons called and of the Time area are used to adjust the cycle duration Buttons called and of the Speed area are used to choice the speed of the cycle 2 6 Technical Features Technical characteristics Power requirements 50 Hz 60 Hz Power consumption Fuse specifications Physical Environmental conditions ia Height 397 mm cover open Operating temperature 15 85 HR lt 2000 m Operating characteristics Ref 06404 800 DU002 A bertin es TECHNOLOGIES age This document is the property of Bertin Technologies It cannot be used reproduced or d
6. replaced by the user with a screwdriver see 7 2 1 1 5 Biological Risks Wear gloves when handling samples and follow strictly all of the safety instructions related to bio hazardous agents to prevent any risk of contamination The waste produced by the normal operation of the instrument must be disposed of in biological waste containers and handled by specialized companies 1 1 6 Maintenance The equipment can only be repaired by either the authorised distributor or the manufacturer 1 1 7 Noise Level The equipment s noise level is below 75 dBa when in operating mode at the maximum speed 1 1 8 Electromagnetic Interference WARNING This is a Class A apparatus The equipment may cause radio electric interference in a residential environment In this case it is recommended that the user takes appropriate measures 1 1 9 Intensive Use If this device is used in an intensive manner high speed and long cycle duration the temperature of the system will increase A high temperature level may cause the thermal security protection to function In this case the electrical power input of the motor will be cut automatically to avoid overheating of the device 1 2 Warranty Bertin Technologies certifies that this product is free of defects at the time of shipment This warranty is limited to a period of one 1 year and it does not apply to the following parts fuses tube adapter This warranty is not applicable in the follo
7. s technical specifications and the following information are subject to change without prior notice 1 1 Safety Information This user manual must be read carefully before operating the Minilys If there is any doubt or concern about the safety of the equipment please contact your local distributor 1 1 1 Use of the lysing kits Depending on the parameters of the MINILYS speed cycle duration waiting time between two cycles an important overheating of the lysing tubes may lead to their sudden degradation To prevent any risk to the user when running the MINILYS it is scrupulously recommended to use the lysing kits produced by Bertin Technologies and respect the use limits defined for each lysing kit Those limits specify maximum level for parameters speed number of cycles cycle duration waiting time between two cycles etc It will ensure good biological samples preparation The use limits of every Lysing kits are available on the website www precellys com or in each Bertin Technologies Kit 1 1 2 Risk of Electric Shock Although this equipment is fully insulated and grounded it is important for all users to be aware of the potential hazard of using liquids close to a power supply If any liquids are spilled disconnect immediately the instrument from the main power supply remove the power cord from the AC power input on the rear panel and clean the equipment and the surrounding area Do not reconnect the equipment until it h
8. 002 A bertin Page 17 23 TECHNOLOGIES age This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 5 2 11 Interrupting a Run The user can stop a run by pressing the Stop button The holder is stopped and the unit displays Stp By pressing Start or Stop button the LCD screen and the speed light indicate the parameters of the last cycle operated The unit is ready to a new run WARNING Wait until the complete stop of the unit before opening the cover 6 Alarms 6 1 Alarm Messages before Starting a Run When the user presses the Start button to start a run the system checks information from the cover sensor before allowing a run to start If the cover is not properly closed the unit displays toP and the status light is flashing red Ref 06404 800 DU002 A be rt IN Page 18 23 TECHNOLOGIES This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies By pressing Start or Stop button the unit returns into the main status ready to start 6 2 Run Interruption by Alarm Messages A run in progress can be stopped by alarm messages 6 2 1 Cover Alarm If the cover is opened while a run is in progress the cover alarm sets off and the run stops immediately The message toP is
9. BT DO3 Na bertin TECHNOLOGIES Ref 06404 800 DU002 A perunt NEW GENERATION Tissue homogenizer SAMPLE PREPARATION amp CELL LYSIS Headquarters Parc d Activit s du Pas du Lac 10 bis avenue Amp re Montigny le Bretonneux France Address BP 284 78053 Saint Quentin en Yvelines Cedex France Phone 33 0 1 39 30 60 00 Fax 33 0 1 39 30 09 50 Locations Aix en Provence 33 0 4 42 60 46 00 Bordeaux 33 0 5 56 40 79 79 Tarnos 33 0 5 59 64 86 48 Toulouse 33 0 1 39 30 60 00 S A S au capital de 3 000 000 Euros 422 511 204 RCS VERSAILLES Code APE 71 12 Bp Siret 422 511 204 00030 TVA Intracommunautaire FR 92422511204 www bertin fr ISO 9001 BUREAU VERITAS Certification Aix Tarnos Montigny le Bretonneux 1 1 1 Meleti Lohse 1 10 1 1 4 1 1 9 TL6 ANE 1 1 8 1 1 9 1 2 1 3 1 4 Ro 2 alk ee 2 3 2 4 ZS 2 6 3 3 1 J2 4 4 1 4 2 Table of contents NTU OCLC TION arai Rene 4 Safety IMTOMMMO 1 0 AE RE RE ER TRE RE 4 D COR E e E epee ens sede ce sess ce E aacasee EAE E 4 RISK OF Ve CEO 11016 CPR SE 4 Jatetoldgeye if 0 lt 1 21110 9 PR 4 SR A ed eraeee deat ted ead E em iacea ieee cetaks 5 POOO ARAI K eea E O 5 EAE S E E A AA E PE UE eneabieetenctdneneeetieetoes 5 Neen See hee E E es re se eee 5 Electromagnetic Interference is D OS ee er ee Re ee eee een ee eee
10. Stop button 7 3 2 Number of Cycles When the unit is switch on by pressing the Stop button during 5 seconds the screen displays the accumulated number of cycles done by the unit The 3 lights of the speed are on and the status light is orange The number displayed has to be multiplied by 10 to know the number of cycles To return into the main status the user must press Start or Stop button 7 4 Cleaning and Decontamination 7 4 1 Recommendations The casing of the unit can be cleaned up with a sponge or a damp cloth moistened with water or alcohol WARNINGS For safety purposes and to prevent any damage of the unit the recommendations listed below should be strictly followed gt Do not spray water or alcohol directly on the unit especially in the air openings Always disconnect the power cord before cleaning Do not use any type of scrapers Do not use caustic soda or acetone Do not use an aerial decontamination process vv vV Yy 7 4 2 Example of Decontamination Procedure lf a tube breaks when a run is in progress decontaminate parts that may have been contaminated with an appropriate disinfectant The decontamination procedure is of the sole responsibility of the user Parts that may have been contaminated can be cleaned with a sponge or a damp cloth moistened with bleach at 6 Cl In case another decontamination procedure is to be applied please first contact technical assistance to e
11. as been fully inspected 1 1 3 Incorrect Operation Operating this equipment in other ways than those detailed in this user manual may impair the protection of the unit gt Do not turn the unit upside down during working the Minilys must always rest on its 4 feet for fear of damaging internal components or breaking plastic casing gt Do not operate the unit when the casing is removed potentially lethal voltage exists within the instrument gt Do not operate the unit with the safety ground disconnected gt Do not install unauthorised cards spare components or accessories as this may impair the safety of the unit and the warranty will be void gt Do not overfill the tubes as this may lead to liquid contamination and impair the safety of the unit gt Check that the voltage indicated on the rear panel of the unit matches to the local power supply gt Check that the power cord is properly plugged in Colour codes are as follows 1 r Ref 06404 800 DU002 A bertin Page 4 23 TECHNOLOGIES age This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies International Phase Bo Earth Ground Yellow amp Green 1 1 4 Fuses The equipment contains two replaceable external fuses located on the rear panel If one of the fuses is to be replaced please use the following fuse 5x20 F 2 A H 250 V It can easily be
12. in grinding tubes at variable speeds It can simultaneously agitate tubes with biological sample volumes up to 7 mL at very high speed Minilys main advantages include vvvvyv Easy tube loading removal holder Easy decontamination zones which have to be decontaminated are easily accessible Flexible and easy cycle programming time speed No alteration of the biological samples and no cross contamination Efficient and homogeneous lysis in all the tubes The Minilys lyser homogeniser is shown hereafter Cover Tube blocking rod Tube adapter Air opening Metalic holder Keypad Air opening Power ON switch Main supply plug Fuses holder 2 2 Tube Motion Thanks to the equipments design every tube of the same size follows the same motion to ensure the same level of lysis and homogenization for each sample The centre of gravity of the tubes follows a tri dimensional path on a sphere s surface While the mixture contained in grinding tubes moves in all directions it moves primarily in the vertical axis to allow for efficient homogenization The movement generated by the MINILYS equipment is called a precession movement i e grinding tubes are not rotated Each 2mL tube has a stroke of 16mm projected on the main vertical axis Each 7mL tube has a stroke of 17mm projected on the main vertical axis i A r Ref 06404 800 DU002 A bertin Page 7 23 TECHNOLOGIES age This doc
13. ing items gt Ve VY VV Vv Vv Vy 1 Minilys 2 holders for 2mL tubes 2 holders for 7mL tubes 1 user manual 1 CE Declaration of Conformity 1 QC report 1 AC power cord 2 extra fuses 1 10mm allen key for shipment screw plug adapter or a compatible power cord not included is required for the UK and other countries such as the USA Canada Japan etc 2 Remove the MINILYS from the box and place it on a clean horizontal and stable surface weight of the Minilys 8 kg WARNING Do not operate the equipment if the shipment screw is not totally removed from the equipment see 4 2 3 Unpack the MINILYS with care and inspect it carefully Report any damage to the carrier immediately 4 Save the packaging material especially the shipment screw in case a return is necessary 4 2 Installation and Connecting the Power Supply 1 Remove the shipment screw located under the equipment 4 e Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 12 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies WARNING Save this shipment screw it must ABSOLUTELY be put back in place before shipping the unit If the unit is returned to the distributor or manufacturer without this protection in place the warranty will be void 2 Ensure that both air openings are clear WARNING Allow at least 15cm of space
14. isclosed without the prior written permission of Bertin Technologies CR EE Acceess o es Deseleraion time ea A 3 digit LCD back light Display 1 lights 3 colors green red and orange Capacity 3 x 2ml Number of tubes or 1 x 7ml Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 10 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 3 Transport Storage 3 1 Transport Avoid violent shocks that may damage the equipment Before transporting the equipment it is necessary to gt Close the cover gt Screw the shipment screw under the equipment gt Use the foam and the box provided with the equipment 3 2 Storage The unit must be stored in a dry area at a temperature ranging from 0 to 50 4 a m Ref 06404 800 DU002 A bertin saws TECHNOLOGIES age This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 4 Installation WARNING Do not connect the unit to the main supply before the installation is over Do not turn the unit upside down expect for unscrewing the shipment screw the Minilys must always stand on its 4 feet in order to avoid damaging internal components or breaking plastic casing 4 1 Unpacking 1 Check the content of the box The box must contain the follow
15. nansiiionennu een ENEAS EESE aE nE TOKES RENES 17 Seek ENON A o E N 17 eek AIS PO AO a RUN serres a a a 18 6 PANNE E I A E A OE OE EN A OEO E OEA EA E EN E E O T 18 6 1 Alarm Messages before Starting a Run 18 6 2 Run Interruption by Alarm MESSAGES ies tdeiswincccientdieeinincienteteeidecintdeeeinmtiewins 19 6 2 1 CON OPA E O EN EA EEA 19 6 2 2 EE o E EE TE E A EA ET A A I A E E A EE A E EET 19 6 3 What to Do When an Alarm Message Occurs 21 T MAMMENN COLE E E 21 7 1 Trouble SOO ING dE mo a inp onn ana aa aR a a on a 21 Le RDA SAS PR a E ETT 22 pene Replacing Tube BIO CROSS nee ne ee no con 22 lee Replacing Eli ER tious cntateeicntim a euhdncimtmaleprina awh dectharnalc nanan ainanelapinanendsimanehe seis 22 rece CS A E E A E A A E E A E TA 23 ol SO asdceaesaneadossaeece eodecedeecesteases used escees 23 gone Number Re ES 0 i a nen eee an ee ee ee ee ce 23 7 4 Cleaning and Decontamination cccscccceecceeecceeeceuceceucecsueeceeecsusenseeseueessueeseeessueeaes 23 7 4 1 SCO OS OS nee Ne ea eee eee 23 7 4 2 Example of Decontamination Procedure 23 oz e Ref 06404 800 DU002 A be rtin Page 3 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 1 Introduction This user manual includes the required information regarding unpacking installation operation and maintenance of the MINILYS The product
16. nsure the compatibility of the new procedure with the instrument Ref 06404 800 DU002 A bertin Page 23 23 TECHNOLOGIES This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies
17. oR eres eee ee Ree 5 Te AO ne E T E ee a ne 5 PRUE PR MTN siriasi crr r a a En ne 6 Manufacturer Mormann a nn 6 CES e g E A E AEE EE Mer E Mer Veen E EE E E CTR 6 Description of the MINIL VS nsme mncnaenemecmnnsomemmorensnnsmesenecmenesuessess 7 Produc ONE te ott weet a E 7 TUDE MOO e A cette gacp cates ae cee oongaceoeneeeceteouedo 7 Dey SUC RS TUN I oc coc hereto E a a a eaee ce 8 FF MOI UCN MV RP PR Re ea weca de tamneees 8 Presentation of the i CY AO nd a a vds 8 CHG AN me LUE CS aaa dtematcamctssaamtemiacancaasedute nantes 9 Transport Storage aaa a is se ne ie 11 CAS BORD Ro dl oi ie 11 1 gt 6 ae AA EEE ge ee nee eee ee eee ae ee 11 BOYS eA FO Boas Re 12 MTA NG seats ecto Seta E PEA A E E 12 Installation and Connecting the Power Supply 12 om e Ref 06404 800 DU002 A be rtin Page 2 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 5 Instructions OUR ee ae es nnne 14 BAd Prepa oN Ole e E R EEEE 14 de COLE AI ECS A mL LS ER oseeteeedoeong ce sebaecedeeseseeece besceseresecense basses A 14 5 2 1 Turning the OLIEN EONRSS eme eee 14 9 2 2 Aarna OR e a a 14 5 2 0 CSA TV COR E ne 14 5 2 4 Tubes holder to be used 15 5 25 Loading Grinding Tubes 4 19 5 2 6 COS AO A CONS E 17 SATA Adjusting the Duration of the cycle nn nec ere encens 17 5 2 8 Adjusting the SDS 17 5 2 9 Running a Progra secscssec
18. ument is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies The tubes must be compatible with the holder and must withstand 600 G of linear acceleration during 3 minutes without suffering any deformation see use instruction 1 1 1 and recommended references 2 3 Precession movement doing biological sample homogenization also causes an increase of temperature of the samples and the equipment 2 3 Lysing kits MINILYS The Minilys lysing kits range is strictly the same than the Precellys lysing kits range This range includes tubes ready to use containing beads adapted to every sample type References of the lysing kits are available on the website www precellys com 2 4 Programming The MINILYS has been designed to operate at a maximum speed of 5 000 rpm A run consists of one cycle within witch the cover must not be opened Speed as well as cycle duration can be adjusted by the keypad Parameters Operating range i a 3 000 4 000 or 5 000 rp Cycle duration From 5 to 240s in increments of 1 second The operator is responsible for programming the unit For high speed operation it is recommended to reduce each cycle duration and let the unit cool down between 2 cycles at least 2 minutes A security device disables the unit to prevent overheating 2 5 Presentation of the Keypad The LCD screen lights up when the MINILYS is switched
19. upply is not suitable unit matches that delivered by the main power supply cord 1 Leave the unit off 2 Ensure air openings are clear Engine temperature has reached the pening safety limit 3 After 30 minutes of cooling if the alarm is still on contact technical assistance Speed regulation or detection system 1 Turn off the unit is faulty 2 Contact technical assistance 7 Maintenance WARNING Potentially dangerous voltage exists inside the instrument to ensure the user s safety only the technical assistance authorized persons by Bertin Technologies can remove the shell to repair the unit Do not turn the unit upside down the MINILYS must always rest on its 4 feet for fear of damaging internal components or breaking plastic casing 7 1 Troubleshooting Guide List of main problems during the use and actions to be done are presented in the following table 1 Check main power voltage No power on the main power Check the voltage of the unit matches that No display on the plug delivered by the main power supply screen Check the unit is plugged in properly Faulty fuse oe fuse Faulty displ t Turn off the unit au isplay system 2 Contact technical assistance If a dangerous or potentially dangerous product is contained in the tube apply the proper decontamination procedure One or several The cap is not properly screwed tubes are not tight or the tube is faulty s Ref
20. wing circumstances gt The equipment has not been installed operated maintained or shipped according to the instructions described in this user manual gt The equipment has been repaired or modified by unauthorised personnel gt The equipment serial number has been damaged or removed bertin Ref 06404 800 DU002 A TECHNOLOGIES Page 5 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 1 3 Minilys Reference Code MINILYS 06404 200 RD000 1 4 Manufacturer Information BERTIN TECHNOLOGIES Parc d activites du Pas du Lac 10 bis avenue Ampere BP 284 78053 Saint Quentin en Yvelines Cedex France Tel 33 0 1 39 30 60 00 Fax 33 0 1 39 30 60 85 1 5 Technical Support First read this user manual very carefully If you cannot solve the problem after having used this manual please contact the nearest distributor s office or Bertin Technologies Customer Support Department located in France see the address above bert TECHNOLOGIES in Ref 06404 800 DU002 A Page 6 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies 2 Description of the MINILYS 2 1 Product Overview The MINILYS lyser homogeniser has been designed to lyse and to homogenise biological samples contained
21. you reach the top of the body 5 2 4 Tubes holder to be used Each tubes holder is specific to a grinding tubes size which can be used with the Minilys Use the appropriate holder with the tubes of the lysing kits range defined by Bertin Technologies on the website www precellys com Holder for 3 x 2mL tubes Holder for 1 x 7mL tubes 5 2 5 Loading Grinding Tubes Lysing tubes filled with samples are placed on the holder and are held down by the tubes blocking rod The Minilys has a capacity for 3x2 mL tubes or 1x7 mL tubes During a run only same type of tubes can be located on the tubes holder WARNING When loading tubes make sure that gt The holder is properly positioned in his housing gt The tubes are properly positioned in the holder in case of using only one 2 mL tube put the tube at the central position on the 2ml holder see photo hereafter tin Ref 06404 800 DU002 A scenes Hedi Page 15 23 This document is the property of Bertin Technologies It cannot be used reproduced or disclosed without the prior written permission of Bertin Technologies Correct and only position for 1 tube Correct and only position for 2 tubes gt The tube blocking rod is properly pushed this part must be positioned on the cap of each tube and under the metallic finger on the right side Tube blocking rod locked position Ref 06404 800 DU002 A bertin TECHNOLOGIES Page 16 23 This document is the property