Home

Port Commands Set

image

Contents

1. 63 0 15 3 Stat amp Activity vio icio Ioan SR o aee oro Pene 69 6 16 POM MINONO S osa eio etus sw ui tede do aru es uto EU NOE 71 6 17 Rate Limiting sarreran e aa 72 OPNS DOM orc CT 73 6 19 VLAN configuration sssssesessse 74 6 18 1 Port based VLAN sess 75 648 2 3802 TO VEA s act rop utem petes 78 6 20 Rapid Spanning Tree 83 6 19 1 RSTP System Configuration 83 6 19 2 Port Configuration cue rx herir eap RES Rus 85 6 21 SNMP Configuration 87 6 20 1 System Configuration sssse 87 6 20 2 Trap Configuration sssesssss 89 6 20 3 SNMPV3 Configuration 90 6 22 QoS OConfiguration sssssse 93 6 21 1 QoS Policy and Priority Type 93 6 21 2 Port based Priority 94 6 21 3 COS Configuration essssss 95 6 21 4 TOS Configuration eessssss 95 6 23 IGMP Configuration sssse 96 6 24 Pro Ring ll System ssseussss 98 6 25 LLDP Configuration sssssse 101 6 26 Security 802 1X Radius Configuration 102 6 25 1 System Configuration 102 6 25 2
2. 120 WB Pin out of PoE Endspan Hub Switch Note Pin Signal Name 1 TX VCC 2 TX VCC 3 TX VCC 4 5 6 TX VCC 7 8 and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise you may need to change one of the RJ 45 connector pin assignment attached with the UTP cable 121 Appendix B Command Sets Commands Set List User EXEC E Privileged EXEC P Global configuration G VLAN database V Interface configuration I System Commands Set Commands Level Description Example show config E Show switch switch gt show config configuration show terminal P Show console switch show terminal information write memory P Save user switch write memory configuration into permanent memory flash rom system name G Configure system switch config system name xxx System Name name system location G Set switch system switch config system location System Location location string XXX system description G Set switch system switch config system System Description description string description xxx system contact G Set switch system switch config system contact System Contact contact window string xxx show system info E Show system switch gt show system info information ip address G Configure the IP switch config ip address lp
3. X Ring2 Ring Information X Ring2 Version 0 043 49 Index Ring ID 1st Ring Port 2nd Ring Port Mode 1st Rdn Port 1st Rdn Port ID 2nd Rdn Port 2nd Rdn Port ID 1 1 Port O1 BLK Port 02_FWD NORMPort 09 FWD 1 Port 10 BLK 1 X ring2 Interface NOTE 1 When the X Ring2 function enabled the user must disable the RSTP 99 The X Ring2 function and RSTP function cannot exist on a switch at the same time 2 Remember to execute the Save Configuration action otherwise the new configuration will lose when switch powers off 100 6 25 LLDP Configuration Link Layer Discovery Protocol LLDP is defined in the IEEE 802 1AB it is an emerging standard which provides a solution for the configuration issues caused by expanding LANs LLDP specifically defines a standard method for Ethernet network devices such as switches routers and wireless LAN access points to advertise information about themselves to other nodes on the network and store the information they discover LLDP runs on all 802 media The protocol runs over the data link layer only allowing two systems running different network layer protocols to learn about each other B LLDP Protocol Pull down the selection menu to disable or enable LLDP function B LLDP Interval Set the interval of advertising the switch s information to other nodes B Click Apply LLDP Configuration LLDP Protocol Disable v LLDP Interval 30 sec Apply Help LLDP Interface
4. AABBCCDDEEFF Port O1 FFEEDDCCBBAA Port O1 MAC Address 458833445566 Port No Port o1 Delete Help Static MAC Addresses interface 107 6 27 2MAC Filtering By filtering MAC address the switch can easily filter the pre configured MAC address and reduce the un safety You can add and delete filtering MAC address MAC Address Table MAC Filtering Static MAC Addresses I MAC Filtering l All Mac Addresses Multicast Filtering 142B3C4D5E6F A1B2C3D4ESF6 MAC Address amp e4cSa3b2dif Delete Help MAC Filtering interface B MAC Address Enter the MAC address that you want to filter B Click Add W f you want to delete the MAC address from the filtering table select the MAC address and click Delete 108 6 27 3 All MAC Addresses You can view all of the MAC addresses learned by the selected port Select the port number m The selected port of static amp dynamic MAC address information will be displayed in here M Click Clear MAC Table to clear the dynamic MAC addresses information of the current port shown on the screen MAC Address Table All Mac Addresses Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering Port No Port 02 112244335566 STATIC 334455662211 STATIC FFE3D2CC213F STATIC Dynamic Address Count Static Address Count 3 Clear MAC Table All MAC Address interface 109 6 27 4 MAC Address Table Multicast Filtering
5. System Configuration Client Entries Port and IP Binding Port IP Port 01 0 0 0 0 Port 02 0 0 0 0 Port 03 0 0 0 0 Port 04 0 0 0 0 Port 05 0 0 0 0 Port 06 0 0 0 0 Port 07 0 0 0 0 Port 08 0 0 0 0 Port 09 0 0 0 0 Port 10 0 0 0 0 Apply Help Port and IP Bindings interface 39 6 7 TFTP It provides the functions allowing the user to update the switch firmware via the Trivial File Transfer Protocol TFTP server Before updating make sure the TFTP server is ready and the firmware image is located on the TFTP server 6 7 1 Update Firmware W TFTP Server IP Address Type in your TFTP server IP m Firmware File Name Type in the name of the firmware image file to be updated B Click Apply TFTP Update Firmware Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 168 16 2 Firmware File Name image bin Apply Help Update Firmware interface 40 6 7 2 Restore Configuration You can restore a previous backup configuration from the TFTP server to recover the settings Before doing that you must locate the image file on the TFTP server first and the switch will download back the flash image TFTP Server IP Address Type in the TFTP server IP Restore File Name Type in the correct file name for restoring B Click Apply TFTP Restore Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 19
6. The user commands available at the user level are a subset of Begin a Enter those available at the User EXEC session with switch gt logout or privileged level your switch quit Use this mode to Perform basic tests Display system information The privileged Enter the command is the enable Enter advanced mode Privileged EXEC command Switch disable to Use this mode to while in User exit Display advanced EXEC mode function status Save configuration 29 Global Configuration VLAN database Interface configuration Enter the configure command switch while in config privileged EXEC mode Enter the vlan database switch vlan command while in privileged EXEC mode Enter the interface of fast Ethernet command with a switch specific interface while in global configuration mode config if To exit to privileged EXEC mode enter exit or end To exit to user EXEC mode enter exit To exit to global configuratio n mode enter exit To exit to privileged EXEC mode enter exit or end 30 Use this mode to configure those parameters that are going to be applied to your switch Use this mode to configure VLAN specific parameters Use this mode to configure parameters for the switch and Ethernet ports Chapter 6 Web Based Management This section introduces the configuration and functions of the Web Based management 6 1
7. configuration no snmp community strings Community Remove the specified community Switch config no snmp community strings public no snmp server host Host address Remove the SNMP server host Switch config no snmp server host 192 168 1 50 no snmpv3 user User Name Remove specified user of SNMPv3 agent Switch config no snmpv3 user Test no snmpv3 access context name Context Name group Group Name security level NoAuthNoPriv AuthNoP riv AuthPriv match rule Remove specified access table of SNMPv3 agent Switch config no snmpv3 access context name Test group G1 security level AuthPr iv match rule Exact views V1 V1 V1 137 Exact Prifix views Read View Name Write View Name Notify View Name no snmpv3 mibview view View Name type Excluded Included sub oid OID Remove specified mibview table of SNMPV3 agent Switch config no snmpv3 mibview view V1 type Excluded sub oid 1 3 6 1 Port Mirroring Commands Set Commands Level Description Example monitor RX TX Both Configure source port of monitor function switch config interface fastEthernet 2 switch config if amp monitor RX monitor rx Port ID Set RX destination port of monitor function switch config monitor rx 2 monitor tx Port ID Set TX destination port of monitor function switc
8. 6 9 Fault Relay Alarm The Fault Relay Alarm function provides the Power Failure and Port Link Down Broken detection With both power input 1 and power input 2 installed and the check boxes of power 1 power 2 ticked the FAULT LED indicator will then be possible to light up when any one of the power failures occurs As for the Port Link Down Broken detection the FAULT LED indicator will light up when the port failure occurs certainly the check box beside the port must be ticked first Please refer to the segment of Wiring the Fault Alarm Contact for the failure detection B Power Failure Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails W Port Link Down Broken Tick the check box to enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken BW MAC Violation Tick the check box to enable the function of lighting up FAULT LED on the panel when MAC address is violated Fault Relay Alarm Power Failure Power 1 LlPower 2 Port Link Down Broken Opor 1 LlPort 2 LlPort 3 LlPort 4 L Ports Mport 6 iViPort 7 Liports L Port 9 LlPort 10 MAC Violation MAC Violation Fault Relay Alarm interface 49 6 10 SNTP Configuration SNTP Simple Network Time Protocol is a simplified version of NTP which is an Internet protocol used to synchronize the clocks of computers to some time reference Because time usually just advances the time on different no
9. DHCP server The default IP address will be replaced by the assigned IP address on DHCP server After the user clicks Apply a popup dialog shows up to inform the user that when the DHCP client is enabled the current IP will lose and user should find the new IP on the DHCP server m P Address Assign the IP address that the network is using If DHCP client function is enabled this switch is configured as a DHCP client The network DHCP server will assign the IP address to the switch and display it in this column The default IP is 192 168 16 1 or the user has to assign an IP address manually when DHCP Client is disabled WB Subnet Mask Assign the subnet mask to the IP address If DHCP client function is disabled the user has to assign the subnet mask in this column field WB Gateway Assign the network gateway for the switch If DHCP client function is disabled the user has to assign the gateway in this column field The default gateway is 192 168 16 254 DNS1 Assign the primary DNS IP address DNS2 Assign the secondary DNS IP address B And then click Apply 34 IP Configuration DHCP Client Disable v IP Address 192 168 16 1 Subnet Mask 255 255 255 0 Gateway 192 168 165 254 DNS1 0 0 0 0 DNS2 0 0 0 0 Apply Help IP configuration interface 35 6 6 DHCP Server DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for assigning dynamic IP addresses to devices on a networ
10. and capability on the LAN IEEE802 1d spanning tree IEEE802 1w rapid spanning tree Supports X ring Il Provides redundant backup feature and the recovery time below 10ms The quality of service determined by port Tag and IPv4 Type of service IPv4 Different Service Supports IEEE802 1p class of service per port provides 4 priority queues Supports 100 entries of MAC address for static MAC and another 100 for MAC filter Supports 3 mirroring types RX TX and Both packet IP Security Login Security Bandwidth Control SNMP Trap Supports IGMP snooping v1 v2 256 multicast groups and IGMP query Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder Supports IEEE802 1X Authentication RADIUS Support ingress packet filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 100K 102400Kbps 10 100 100K 256000Kbps 1000 Ingress filter packet type combination rules are Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The packet filter rate can be set from 100K 102400Kbps 10 100 100K 256000Kbps 1000 Supports Flow Control for Full duplex and Back Pressure for Half duplex Supports System log record and remote system log server Supports SMTP Server and 6 e mail accounts for receiving event alert Provides one relay output for port
11. 1 bx index htm User name root Password ITI M Login screen 32 6 4 System Information User can assign the system name description location and contact personnel to identify the switch The version table below is a read only field to show the basic information of the switch B System Name Assign the system name of the switch The maximum length is 64 bytes m System Description Describes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer default B Andthen click Apply System Information System Name D E System Description 8 10 100TX 2 10 100 1000T Mini GBIC Combo w 8 PoE Injec System Location System Contact Apply Help Firmware Version v1 11 Kernel Version v1 58 MAC Address OOOF38674FFB Switch settings interface 33 6 5 IP Configuration The switch is a network device which needs to be assigned an IP address for being identified on the network Users have to decide a means of assigning IP address to the switch B DHCP Client Enable or disable the DHCP client function When DHCP client function is enabled the switch will be assigned an IP address from the network
12. 31 Security IP4 192 168 16 41 Security IP5 192 168 16 110 Security IP6 192 168 16 120 Security IP7 192 168 16 130 Security IPS 192 168 16 140 Security IP9 192 168 16 210 Security IP10 192 168 16 220 Apply Help IP Security interface 55 6 12 User Authentication Change web management login user name and password for the management security issue User name Type in the new user name The default is root Password Type in the new password The default is root Confirm password Re type the new password B Andthen click Apply User Authentication User Name root New Password m Confirm Password me Apply Help User Authentication interface 56 6 13 Port Statistics The following chart provides the current statistic information which displays the real time packet transfer status for each port The user might use the information to plan and implement the network or check and find the problem when the collision or heavy traffic occurs Port The port number Type Displays the current speed of connection to the port Link The status of linking Up or Down State It s set by Port Control When the state is disabled the port will not transmit or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 octets oversize CR
13. Configure SMTP switch config smtp serverip IP address server IP 192 168 1 5 smtp sender Configure sender of switch config smtp snder sendername mail aaa bbb com smtp authentication Enable SMTP switch config smtp authentication authentication smtp account Configure switch config smtp account account authentication account John smtp password password Configure authentication password switch config smtp password 1234 smtp rcptemail Index Email address Configure Rcpt e mail Address switch config smtp rcptemail 1 Alert Qtest com show smtp Show the information switch show smtp of SMTP no smtp Disable SMTP switch config no smtp function event device cold start Systemlog SMTP Both Set cold start event type switch config event device cold start both event authentication failure Systemlog SMTP Both Set Authentication failure event type switch config event authentication failure both 142 event ring topology change Systemlog SMTP Both Set X ring topology changed event type switch config event ring topology change both event systemlog Set port event for switch config interface Link UP Link system log fastethernet 3 Down Both switch config if amp event systemlog both event smtp Set port event for switch config interface Link UP Link SMTP faste
14. DIES RIEGO WIE DIET DEED e Priority 40 41 43 45 Fave rel ven en fave zl mes rre ere Priority 48 Fave reni ren fines ave ven ven renee Priority 56 Lowest ER z nA x nme m mE ms A z Apply Help QoS Configuration interface 6 21 2 Port based Priority Configure the priority level for each port With the drop down selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port 94 m Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen W Click Apply to have the configuration take effect 6 21 3 COS Configuration Set up the COS priority level With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port B COS priority Set up the COS priority level 0 7 High Middle Low Lowest B Click Apply 6 21 4 TOS Configuration Set up the TOS priority With the drop down selection item of Priority Type above being selected as TOS only TOS first this control item will then be available to set the queuing policy for each port B TOS priority The system provides 0 63 TOS priority level Each level has 4 types of priority High Middle Low and Lowest The default value is Lowest priority for each level When the IP packet is received the system will check the
15. LLDP Commands Set xiii eee 134 Mac Filter Table Commands Set 135 SNMP Commands Set ueueueseses 135 Port Mirroring Commands Set 138 802 1x Commands Set eeeeeesessss 139 TFTP Commands Set sss 141 SystemLog SMTP and Event Commands Set 141 Fault Relay Alarm Commands Set 143 SNTP Commands Setini i 144 Pro Ring Il Commands Set 145 PoE Commands Set cccccesceccecceccececceceecaeceeeas 146 Chapter 1 Introduction The 8 Port 10 100TX 2 Port 10 100 1000T Dual Speed SFP Combo w 8 PoE Injector Managed Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Besides the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 cable 1 1 Hardware Features IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX IEEE802 3ab 1000Base T IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP Standard IEEE802 3af Power over Ethernet IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authenticatio
16. Multicasts are similar to broadcasts they are sent to all end stations on a LAN or VLAN Multicast filtering is the function which end stations can receive the multicast traffic if the connected ports had been included in the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations W P Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 B Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address W Click Add to append a new filter of multicast to the field or select the filter in the field and click Delete to remove it MAC Address Table Multicast Filtering Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering l 239 000 000 100 qm 239 000 001 100 aE fact as 239 000 002 100 2 ee IP Address 239 0 3 100 Port 01 Port o2 l Port o3 I Port o4 Member Ports Port 05 Port D06 M Port o7 M Port as Tl Port o9 Port 10 Add Delete Help Multicast Filtering interface 110 6 28 Power over Ethernet Po Oni ani uw 0 NO Enable Power Limit From ee rt state Classfication amp 9 cy Priority This segment shows the Power over Ethernet function Power over Ethernet Actual Power Consumption 0 W Main Supply Voltage 480 dV Firmware Version 2 03 P
17. Orange White 2 Orange 3 Green White 4 Blue 6 Green 27 5 3 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None COM2 Properties i 2 x Port Settings Bits per second Els Data hits fe Parity oe j Stop bits nh M Elow control None w Advanced Restore Defaults The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in root default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen User Name root Password Console login interface 28 5 4 CLI Management The system supports the console management CLI command After you log in on to the system you will see a command prompt To enter CLI management interface type in enable command switch gt e switch CLI command interface The following table lists the CLI commands and description 5 5 Commands Level Access About This Mode1 Method
18. Select the ports to join the trunk group The system allows a maximum of four 61 ports to be aggregated in a trunk group Click Add and the ports focused in the right side will be shifted to the left side To remove unwanted ports select the ports and click Remove m When LACP enabled you can configure LACP Active Passive status for each port on the State Activity tab BW Click Apply m Use Delete to delete Trunk Group Select the Group ID and click Delete Port Trunk Aggregator Setting Aggregator Setting Aggregator Information State Activity System Priority MN Group ID Trunk 1 Select Lacp Enable Work Ports Apply Delete Help Notice The trunk function do not support GVRP and X Ring Port Trunk Aggregator Setting interface four ports are added to the left field with LACP enabled 62 6 15 2 Aggregator Information LACP disabled Having set up the aggregator setting with LACP disabled you will see the local static trunk group information on the tab of Aggregator Information Port Trunk Aggregator Setting Aggregator Setting Aggregator Information 1 State Activity System Priority n Group ID Trunk 2 x Select Lacp Work Ports 2 lt lt Add Remove Apply Delete Help Notice The trunk function do not support GYRP and X Ring Assigning 2 ports to a trunk group with LACP disabled Port Trunk Aggregator Information Aggr
19. Standard 6 hours 6 am MDT Mountain Daylight MST Mountain Standard 7 hours 5 am PDT Pacific Daylight PST Pacific Standard 8 hours 4 am ADT Alaskan Daylight HAW Hawaiian 10 hours 2am Standard CET Central European FWT French Winter MET Middle European 1 hour 1 pm MEWT Middle European Winter SWT Swedish Winter EET Eastern 2 hours 2 pm European USSR Zone 1 BT Baghdad USSR 3 hours 3 pm Zone 2 ZP5 USSR Zone 4 45 hours WAST West Australian 7 hours 7 pm Standard 51 CCT China Coast 48 hours USSR Zone 7 JST Japan Standard 49 hours USSR Zone 8 EAST East Australian Standard GST Guam Standard USSR 10 hours Zone 9 IDLE International Date Line NZST New Zealand 12 hours Midnight Standard NZT New Zealand WB SNTP Sever URL Set the SNTP server IP address You can assign a local network time server IP address or an internet time server IP address WB Switch Timer When the switch has successfully connected to the SNTP server whose IP address was assigned in the column field of SNTP Server URL the current coordinated time is displayed here B Daylight Saving Period Set up the Daylight Saving beginning date time and Daylight Saving ending date time Please key in the value in the format of YYYYMMDD and HH MM leave a space between YYYYMMDD and HH MM gt YYYYMMDD an eight digit year month day specification gt HH MM a five digit i
20. breakdown power fail Alarm Relay current carry ability 1A DC24V 1 Topology Change 2 Power Trap 3 MAC Violation Firmware Update Configuration Upload Download Provides DHCP Client DHCP Server Port and IP Binding Provides DNS client feature and supports Primary and Secondary DNS server Supports SNTP to synchronize system clock in Internet Supports TFTP firmware update TFTP backup and restore Supports binary format configuration file for system quick installation Each port allows importing 128bits of alphabetic string of word on SNMP and CLI interface 1 3 Package Contents Please refer to the package content list below to verify them against the checklist W 8 Port 10 100TX 2 Port 10 100 1000T Dual Speed SFP Combo w 8 PoE Injector Managed Industrial Switch x 1 User manual x 1 Pluggable Terminal Block x 1 Mounting plate x 2 RJ 45 to DB9 Female cable x 1 Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Chapter 2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension 8 10 100TX w Pro Ring Managed Industrial Switch dimension W x D x H is 72mm x 105mm x 152mm 2 2 Front Panel The Front Panel of the 8 10 100TX w Pro Ring Managed Industrial Switch is shown
21. by dis communication between the sub VLANs even they are located in the same LAN and have the same IP subnet mask Better yet the configuration is simple than assigning each VLAN as per port based VLAN to customer each home Note 1 2 It s not necessary to type 1 in the tagged VID The hybrid port will forward the frames of VLAN 1 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the same Untagged VID This column field is available when Link Type is set as Access Link and Hybrid Link Assign a number in the range between 1 an 4094 Tagged VID This column field is available when Link Type is set as Trunk Link and 80 Hybrid Link Assign a number in the range between 1 an 4094 W Click Apply to have the configuration take effect W Youcan see the link type untagged VID and tagged VID information of each port in the table below on the screen VLAN Configuration VLAN Operation Mode 802 10 v Cl Enable GVRP Protocol Management Vlan ID D Apply 802 1Q Configuration Group Configuration Port Link Type Untagged Vid Tagged Vid Port 01 Access Link F3 Apply Port Link Type Untagged Vid Tagged Vid Port 01 Access Link 1 Port 02 Trunk Link 1 23 Port 03 Hybrid Link 1 23 Port 04 QinQ 1 23 55 Port 05 Access Link 1 Port 06 Access Link 1 Port 07 Access Link 1 Port 08 Access Link 1 Port 09 Access Link 1 Port 10 Acc
22. partner switch hub workstation etc must be less than 100 meters 328 ft long W Fiber segment using single mode connector type must use 9 125 um single mode fiber cable User can connect two devices in the distance up to 30km W Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2km distances B Gigabit Copper SFP mini GBIC combo port The Industrial switch has the auto detected Giga port Gigabit Copper SFP combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for the connection up to 1000Mbps The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according to the transceiver With fiber optic it transmits at speed up to 1000 Mbps and you can prevent noise interference from the system Note The SFP Copper Combo port can t both work at the same time The SFP port has the higher priority than copper port if you insert the 1000M SFP transceiver which has connected to the remote device via fiber cable into the SFP
23. port the connection of the accompanying copper port will link down If you insert the 100M SFP transceiver into the SFP port even without a fiber connection to the remote the connection of the accompanying copper port will link down immediately To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Triangle Mark f Transceiver to the SFP module Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver 19 LC connector to the transceiver 20 To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it Out Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver 21 Chapter 4 Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is as below Data cola server Human Management Interface Enterprise Switch Industrial Switch Industrial Switch Field Management Programmable logic controller Distribute I O control system Serial Device Server Field Automa
24. server Port Commands Set Commands Level Description Example interface fastEthernet G Choose the portfor X switch config Zinterface Portid modification fastEthernet 2 124 duplex Use the duplex switch config interface full half configuration fastEthernet 2 command to specify _ switch config if duplex full the duplex mode of operation for Fast Ethernet speed Use the speed switch config interface 10 100 1000 auto configuration command to specify the speed mode of operation for Fast Ethernet the speed can t be set to 1000 if the port isn t a giga port fastEthernet 2 switch config if amp speed 100 no flowcontrol Disable flow control of interface switch config if no flowcontrol security enable Enable security of interface switch config interface fastEthernet 2 switch config if security enable no security Disable security of switch config interface interface fastEthernet 2 switch config if no security bandwidth type all Set interface ingress switch config Zinterface limit frame type to fastEthernet 2 accept all frame switch config if bandwidth type all bandwidth type Set interface ingress switch config Zinterface broadcast multicast flooded unicast limit frame type to accept broadcast multicast and flooded unicast frame fastEthernet 2 switch config if bandwidth type broadcast multicast flood
25. the connection parameters and the status of each port is listed beneath W Port Use the scroll bar and click on the port number to choose the port to be configured m State Current port state The port can be set to disable or enable mode If the port state is set as Disable it will not receive or transmit any packet B Negotiation Auto and Force Being set as Auto the speed and duplex mode are negotiated automatically When you set it as Force you have to set the speed and duplex mode manually WB Speed lt is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only m Duplex It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only B Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rate of another device the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time When disabled the receiving device will drop the packet if too much to process WB Security When the Security selection is set as On any access from the device which connects to this port will be blocked unless the MAC address of the device is included in the static MAC address table See the segment of MAC Address Table
26. your network Lease Time sec It is the time period that system will reset the dynamic IP assignment to ensure the dynamic IP will not been occupied for a long time or the server doesn t know that the dynamic IP is idle And then click Apply DHCP Server System Configuration System Configuration Client Entries Port and IP Binding DHCP Server Disable Low IP Address 192 168 16 100 High IP Address 192 168 16 200 Subnet Mask 255 255 255 0 Gateway 192 168 16 254 DNS 0 0 0 0 Lease Time sec sea00 Apply Help DHCP Server Configuration interface 37 6 6 2 Client Entries When the DHCP server function is enabled the system will collect the DHCP client information including the assigned IP address the MAC address of the client device the IP assigning type status and lease time DHCP Server Client Entries System Configuration Client Entries Port and IP Binding IP addr Client ID Type Status Lease 192 168 16 101 00 99 88 77 66 55 dynamic DHCP 86383 192 168 16 100 00 0F 38 FF F5 01 dynamic DHCP 85762 DHCP Client Entries interface 38 6 6 3 Port and IP Bindings Assign the dynamic IP address bound with the port to the connected client The user is allowed to fill each port column with one particular IP address When the device is connecting to the port and asks for IP assigning the system will assign the IP address bound with the port DHCP Server Port and IP Binding
27. 101 6 26 Security 802 1X Radius Configuration 802 1x is an IEEE authentication specification which prevents the client from accessing a wireless access point or wired switch until it provides authority like the user name and password that are verified by an authentication server such as RADIUS server 6 25 1 System Configuration After enabling the IEEE 802 1X function you can configure the parameters of this function IEEE 802 1x Protocol Enable or disable 802 1x protocol Radius Server IP Assign the RADIUS Server IP address Server Port Set the UDP destination port for authentication requests to the specified RADIUS Server Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS Server Shared Key Set an encryption key for using during authentication sessions with the specified RADIUS server This key must match the encryption key used on the RADIUS Server NAS Identifier Set the identifier for the RADIUS client Click Apply 102 802 1x Radius System Configuration System Configuration Port Configuration Misc Configuration 802 1x Protocol Enable v Radius Server IP 192 168 16 237 Server Port 18 12 Accounting Port 1813 Shared Key 12345678 NAS Identifier Nas L2 SWITCH Apply Help 802 1x System Configuration interface 103 6 25 2 Port Configuration You can configure the 802 1x authentication state for each port The state provides
28. 2 168 16 2 Restore File Name data bin Apply Help Restore Configuration interface 41 6 7 3 Backup Configuration You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later It helps you to avoid wasting time on configuring the settings by backing up the configuration WB TFTP Server IP Address Type in the TFTP server IP Backup File Name Type in the file name B Click Apply TFTP Backup Configuration Update Firmware Restore Configuration Backup Configuration TFTP Server IP Address 192 168 16 2 Backup File Name data bin Apply Help Backup Configuration interface 42 6 8 System Event Log This page allows the user to decide whether to send the system event log and select the mode which the system event log will be sent to client only server only or both client and server What kind of event log will be issued to the client server depends on the selection on the Event Configuration tab There are four types of event Device Cold Start Authentication Failure X Ring Topology Change and Port Event available to be issued as the event log 6 8 1 Syslog Configuration B Syslog Client Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only be sent to the
29. 45678 mac address table filter G Configure MAC switch config mac address table hwaddr address table filter filter hwaddr 000012348678 MAC show mac address table P Show all MAC address switch show mac address table table show mac address table P Show static MAC switch show mac address table static address table static show mac address table P Show filter MAC Switch show mac address table filter address table filter no mac address table Remove an entry of switch config Zinterface static hwaddr MAC address table of fastEthernet 2 MAC interface static switch config if amp no mac address table static hwaddr 000012345678 no mac address table G Remove an entry of switch config zno mac address filter hwaddr MAC address table table filter hwaddr 000012348678 MAC filter no mac address table G Remove dynamic switch config no mac address entry of MAC address table table SNMP Commands Set Commands Level Description Example 135 snmp system name System Name Set SNMP agent system name switch config snmp system name l2switch snmp system location Set SNMP agent switch config snmp system System Location system location location lab snmp system contact Set SNMP agent switch config snmp system System Contact system contact contact where snmp agent mode v1v2c v3 v1v2cv3 Select the agent mode of SNMP switch config snmp agent mode viv2cv3 sn
30. About Web based Management There is an embedded HTML web site residing in flash memory on CPU board of the switch which offers advanced management features and allows users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web Based Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen 6 2 Preparing for Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are listed as below IP Address 192 168 16 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 16 254 User Name root Password root 31 6 3 System Login 1 Launch the Internet Explorer on the PC 2 Key in http the IP address of the switch and then Press Enter File Edit View Favorites Tools Help Address e http 192 168 16 1 The login screen will appear right after Key in the user name and password The default user name and password are the same as root 5 Press Enter or click the OK button and then the home screen of the Web based management appears Connect to 192 168 16
31. C Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving good packets including undersize less than 64 octets oversize CRC error fragments and jabbers via this port Tx Abort Packet The aborted packet while transmitting Packet Collision The counts of collision packet Packet Dropped The counts of dropped packet Rx Beast Packet The counts of broadcast packet Rx Mcast Packet The counts of multicast packet Click Clear button to clean all counts 57 Port Statistics Clear Help Port Statistics interface 58 Port rope Link State TX Good Tx Bad Rx Good Rx Bad Tx Abort Packet Packet RX Bcast RX Mcast Packet Packet Packet Packet Packet Collision Dropped Packet Packet Port 01 100TX DownEnable 0 0 0 0 0 0 0 0 0 Port 02 100TX DownEnable 0 0 o 0 0 0 0 0 0 Port 03 100TX DownEnable 0 0 0 O0 0 0 0 0 0 Port 04 100TX DownEnable 0 0 0 0 o O 0 0 0o Port 05 100TX DownEnable 0 0 0 0 0 0 0 0 0 Port 06 100TX DownEnable 0 0 0 O0 0 0 0 0 0 Port 07 100TX Up Enable 466 0 1132 0 0 0 0 137 1 Port 8 100TX DownEnable 0 0 0 0 0 0 o o o Port 09 1GTX mGBICDownEnable 0 0 0 O0 0 0 0 0 0 Port 101GTX mGBICDownEnable 0 0 0 0 0 0 0 0 0 6 14 Port Control In Port control you can configure the settings of each port to control
32. CP clients 192 168 1 1 dhcpserver leasetime G Configure lease time switch config dhcpserver Hours in hour leasetime 1 dhcpserver ipbinding IP address Set static IP for DHCP clients by port switch config interface fastEthernet 2 switch config dhcpserver ipbinding 192 168 1 1 123 show dhcpserver P Show configuration of switchzzshow dhcpserver configuration DHCP server configuration show dhcpserver clients P Show client entries of switch show dhcpserver clients DHCP server show dhcpserver ip P Show IP Binding switch show dhcpserver ip binding information of DHCP binding server no dhcpserver G Disable DHCP server switch config no dhcpserver function security enable G Enable IP security switch config security enable function security http G Enable IP security of switch config Zsecurity http HTTP server security telnet G Enable IP security of switch config security telnet telnet server security ip G Set the IP security list switch config Zsecurity ip 1 Index 1 10 IP 192 168 1 55 Address show security P Show the information switch show security of IP security no security G Disable IP security switch config no security function no security http G Disable IP security of switch config no security http HTTP server no security telnet G Disable IP security of switch config no security telnet telnet
33. Click Apply 85 RSTP Port Configuration System Configuration Port Configuration Path Cost Priority 1 200000000 0 240 44 P2P Admin Edge Admin M 20000t 128 Auto v true false priority must be a multiple of 16 Apply Help RSTP Port Status Path Port Oper Port cost Kx P2P Edge Neighbor State Role Port 01200000 128 True True False Disabled Disabled Port 02200000 128 True True False Disabled Disabled Port 03200000 128 True True False Disabled Disabled Port 04200000 128 True True False Disabled Disabled Port 05 200000 128 True True False Disabled Disabled Port 06 200000 128 True True False Disabled Disabled Port 07 20000 128 False True False Forwarding Designated Port 08200000 128 True True False Disabled Disabled Port 09 20000 128 True True False Disabled Disabled Port 10 20000 128 True True False Disabled Disabled RSTP Port Configuration interface 86 6 21 SNMP Configuration Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices imple
34. Disable Accept Reject and Authorize Reject The specified port is required to be held in the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable When disabled the specified port works without complying with 802 1x protocol Click Apply 802 1x Radius Port Configuration System Configuration D Port Configuration Misc Configuration Port State Port 02 Port 03 Port 04 Authorize Reject Authorize Apply HajtBisable Port Authorization Port State Port 01 Disable Part 02 Disable Port 03 Disable Port 04 Disable Port 05 Disable Port 06 Disable Port 07 Disable Port 08 Disable Port 09 Disable Port 10 Disable 802 1x Per Port Setting interface 104 6 25 3 Misc Configuration Quiet Period Set the period which the port doesn t try to acquire a supplicant TX Period Set the period the port waits for retransmit next EAPOL PDU during an authentication session B Supplicant Timeout Set the period of time the switch waits for a supplicant response to an EAP request W Server Timeout Set the period of time the switch waits for a server response to an authentication request BH Max Requests Set the number of authentication that must time out before authen
35. Lantech IPES 2208C 8 Port 10 100TX 2 Port 10 100 1000T Dual Speed SFP Combo w 8 PoE Injector Pro Ring Managed Industrial Switch User Manual V1 04 Nov 2009 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures W Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver W Connect the equipment into an outlet on a circuit different from that to which the receiver is connected W Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures C
36. P on two switches they are able to automatically exchange the information of their VLAN database Therefore the user doesn t need to manually configure whether the link is trunk or hybrid the packets belonging to the same VLAN can communicate across switches Tick this checkbox to enable GVRP protocol This checkbox is available while the VLAN Operation Mode is in 802 1Q mode mH Management VLAN ID Only when the VLAN members whose Untagged VID PVID equals to the value in this column will have the permission to access the switch The default value is 0 that means this limit is not enabled all members in different VLANs can access this switch Select the port you want to configure Link Type There are 3 types of link type Access Link A segment which provides the link path for one or more stations to the VLAN aware device An Access Port untagged port connected to the access link has an untagged VID also called PVID After an untagged frame gets into the access port the switch will insert a four byte tag in the frame The contents of the last 12 bit of the tag is untagged VID When this frame is sent out through any of the access port of the same PVID the switch will remove the tag from the frame to recover it to what it was Those ports of the same untagged VID are regarded as the same VLAN group members Note Because the access port doesn t have an understanding of tagged frame the column field of Tagged VID is not availab
37. Port Based then press Apply to set the VLAN Operation Mode in Port Based mode W Click Add to add a new VLAN group The maximum VLAN groups are up to 64 75 VLAN Configuration VLAN Operation Mode Port Based Enable GVRP Protocol Management Wlan ID o Apply Group Name VLAN 1 VLAN ID 7o Port D1 Port 02 Port 03 Port 04 Add Remove Apply Help VLAN Port Based Add interface m Enter the group name and VLAN ID Add the selected port number into the right field to group these members to be a VLAN group or remove any of them listed in the right field from the VLAN m And then click Apply to have the configuration take effect B You will see the VLAN list displays 76 VLAN Configuration VLAN Operation Mode Port Based gt Enable GVRP Protocol Management Wlan ID o WYLAN 1 79 Add Edit Delete Help VLAN Port Based Edit Delete interface m Use Delete to delete the VLAN m Use Edit to modify group name VLAN ID or add remove the members of the existing VLAN group NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 77 6 18 2 802 1Q VLAN Virtual Local Area Network VLAN can be implemented on the switch to logically create different broadcast domain When the 802 1Q VLAN function is enabled all ports on the switch belong to default VLAN of VID 1 which means they lo
38. Port Configuration sesssssss 104 6 25 3 Misc Configuration esesssss 105 6 27 MAC Address Table 106 6 27 1 Static MAC Address sss 106 027 2 MAGFIlleringsa uie ret ot 108 6 27 3 All MAC Addresses ssseessss 109 6 27 4 MAC Address Table Multicast Filtering 110 6 28 Power over Ethernet sssse 111 6 29 Factory Default ssssesssss 113 6 30 Save Contiguration 114 6 31 System Reboot suueee 115 Troubles shooting 116 Appendix A RJ 45 Pin Assignment 117 RJ 45 Pin Assignments 117 HJ 45 Pin Assignment of PoE 120 Appendix B Command Sets 122 System Commands Set sssssesssse 122 Port Commands Se t cccccccccceeseeeessseseeeeeeeees 124 Trunk Commands Set eeeeeeeseesss 127 VLAN Commands Set eeeeeeeesessss 128 Spanning Tree Commands Set 130 QOS Commands Set eesussssss 133 IGMP Commands Set eeeeeeseeeessss 133 Multicast Filtering Commands Set 134
39. Static MAC Addresses m Click Apply to have the configuration take effect 59 Port Control State Negotiation Speed Duplex Flow Control Security Enable Auto x 100 Fui z Enable x ort j Apply Help duisi Group miTvpe Link State Negotiation Config Actual Config Actual Y Port 01 N A 100TX Down Enable Auto 100 Full N A Enable N A OFF Port 02 N A 100TX Down Enable Auto 100 FullN A Enable N A OFF Port 03 N A 100TX iDown Enable Auto 100 Full N A EnableN A OFF Port 04 N A 100TX Down Enable Auto 100 Full N A EnableN A OFF Port 05 N A 100TX Down Enable Auto 100 Full N A EnableN A OFF Port 06 N A 100TX Down Enable Auto 100 Full N A EnableN A OFF Port 07 N A 100TX Up Enable Auto 100 Full100 HalfEnable OFF OFF Port 08 N A 100TX Down Enable Auto 100 Full N A Enable N A X OFF Port 09 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port 10 N A 1GTX mGBIC Down Enable Auto 1G Full N A Enable N A OFF Port Control interface 60 6 15 Port Trunk Port trunking is the combination of several ports or network cables to expand the connection speed beyond the limits of any one single port or network cable Link Aggregation Control Protocol LACP which is a protocol running on layer 2 provides a standardized means in accordance with IEEE 802 3ad to bundle several physical ports together to form a single logical channel All the
40. TOS level value in the IP packet that has received For example the user sets the TOS level 25 as high the system will check the TOS value of the received IP packet If the TOS value of received IP packet is 25 priority high and then the packet priority will have highest priority W Click Apply to have the configuration take effect 95 6 23 IGMP Configuration The Internet Group Management Protocol IGMP is an internal protocol of the Internet Protocol IP suite IP manages multicast traffic by using switches routers and hosts that support IGMP Enabling IGMP allows the ports to detect IGMP queries report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message shown as follows A message sent from the querier IGMP router or switch Query asking for a response from each host belonging to the multicast group A message sent by a host to the querier to indicate that the Report host wants to be or is a member of a given group indicated in the report message A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group The switch support IP multicast you can enable IGMP protocol on web management s switch setting advanced page then the IGMP snooping information displays IP multicast addresses range are from 224 0 0 0 through 239 255 255 255 IGMP Protocol enable or disable the IGMP protocol IGMP Query en
41. able or disable the IGMP query function The IGMP query information will be displayed in IGMP status section B MLD Query enable or disable the MLD query function The MLD query information will be displayed in MLD status section B Click Apply 96 IGMP MLD Snooping IP Address VLAN ID Member Port Mode Disable uery Q y IGMP IGMP Configuration interface 97 6 24 Pro Ring Il System Pro Ring Il is a new Ring mechanism for Lantech Industrial Switches in which it eliminates the need to pre set the Master switch in old Pro Ring and yet to protect the network by much secure topologies than ever Pro Ring Il works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier Pro Ring Ill can be backward compatible with old Pro Ring by down grading the Ring scheme to old one Legacy Ring m Enable Legacy Ring To enable the X Ring function tick the checkbox beside the X Ring2 Operation Mode string label If this checkbox is not ticked all the ring functions are unavailable M 1 amp 2 Ring Ports Pull down the selection menu to assign the ports as the member ports 1 Ring Port is the working port and 2 Ring Port is the backup port When 1 Ring Port fails the system will automatically upgrade the 2 Ring Port to be the working port W Andthen click Apply to have the configuration take effect X Ring2 X Ring2 Operation Mode Legacy Ring v L
42. address Subnet address of switch 192 168 1 1 255 255 255 0 mask Gateway 192 168 1 254 122 ip dhcp G Enable DHCP client switch config ip dhcp function of switch show ip P Show IP information of switch show ip switch no ip dhcp G Disable DHCP client switch config no ip dhcp function of switch reload G dad w perform a cold switch config Zireload default G Restore to default switch config default admin username G Changes a login switch config admin username Username username XXXXXX maximum 10 words admin password G Specifies a password switch config tadmin password Password maximum 10 words XXXxxx show admin P Show administrator switchzzshow admin information dhcpserver enable G Enable DHCP Server switch config dhcpserver enable Dhcpserver disable G Disable DHCP Server switch config no dhcpserver dhcpserver lowip G Configure low IP switch config dhcpserver lowip Low IP address for IP pool 192 168 1 100 dhcpserver highip G Configure high IP switch config dhcpserver highip High IP address for IP pool 192 168 1 200 dhcpserver subnetmask G Configure subnet switch config dhcpserver Subnet mask mask for DHCP clients subnetmask 255 255 255 0 dhcpserver gateway G Configure gateway for switch config dhcpserver Gateway DHCP clients gateway 192 168 1 254 dhcpserver dnsip G Configure DNS IP for switch config dhcpserver dnsip DNS IP DH
43. all configuration to the flash memory Save Configuration Save Configuration interface 114 6 31 System Reboot Reboot the switch in software reset Click Reboot to reboot the system System Reboot Please click Reboot button to restart switch device Reboot System Reboot interface 115 Troubles shooting W Verify that is using the right power cord adapter DC 24 48V please don t use the power adapter with DC output higher than 48V or it may damage this device W Select the proper UTP STP cable to construct the user network Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections that depend on the connector type the switch equipped 1000 Category 3 4 or 5 cable for 10Mbps connections 1000 Category 5 cable for 100Mbps connections or 100 Q Category 5e above cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet B Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions W f the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assi
44. ame B Click Remove to remove unwanted context name MIBview Table Configure MIB view table ViewName set up the name Sub Oid Tree fill the Sub OID Type select the type exclude or included Click Add to add context name Click Remove to remove unwanted context name 92 6 22 QoS Configuration Quality of Service QoS is the ability to provide different priority to different applications users or data flows or to guarantee a certain level of performance to a data flow QoS guarantees are important if the network capacity is insufficient especially for real time streaming multimedia applications such as voice over IP or Video Teleconferencing since these often require fixed bit rate and are delay sensitive and in networks where the capacity is a limited resource for example in cellular data communication In the absence of network congestion QoS mechanisms are not required 6 21 1 QoS Policy and Priority Type Here you can choose to use an 8 4 2 1 queuing scheme or a strict priority scheme or select the priority type to configure QoS policy WB Qos Policy Select the QoS policy rule Using the 8 4 2 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from High to lowest queue For example while the system processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the middle queue and 8 frames of the high queue will be processed at the same time i
45. an no vlan group 2 GroupID group ID IEEE 802 10 VLAN vlan 8021q name V Change the name of switch vlan Zvlan 8021q name en VLAN group ifthe test vid 22 VID group didn t exist this command can t be applied vlan 8021q port V Assign a access link switch vlan vlan 8021q port 3 d A ag for VLAN by port if thejaccess link untag 33 UntaggedVID port belong to a trunk group this command can t be applied vlan 8021q port V Assign a trunk link for switch vlan vlan 8021q port 3 didus VLAN by port ifthe trunk link tag 2 3 6 99 TaggedVID List port belong to a trunk jor group this command switch vlan Zvlan 8021q port 3 can t be applied trunk link tag 3 20 vlan 8021q port V Assign a hybrid link for switch vlan vlan 8021q port 3 PortNumber 129 hybrid link untag UntaggedVID tag TaggedVID List VLAN by port if the port belong to a trunk group this command can t be applied hybrid link untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 hybrid link untag 5 tag 6 8 vlan 8021q trunk V Assign a access link switch vlan vlan 8021q trunk 3 Form umben for VLAN by trunk access link untag 33 access link untag UntaggedVID group vlan 8021q trunk V Assign a trunk link for switch vlan vlan 8021q trunk 3 PortNumber 7 trunk link tag VLAN by trunk group trunk link tag 2 3 6 99 TaggedVID List dd switch vlan Zvlan 8021q trunk 3 trunk link tag 3 20 vlan 8021q tr
46. as below Lantech IPES 2208C 8 10 100TX 2 10 100 1000T Dual Speed SFP x o Managed Industrial Switch PWR RM PWR1 PWR2 FAULT P9 Console v daS 0004 00 LOOOL OOL OL o PO Link Active LOOOL OOL OL dS 0001 00 9600 N 8 1 P5 P6 FWD een P7 P8 P5 P6 P3 i ee el P1 P2 P1 P2 10 100TX Front Panel of the industrial switch 2 3 Bottom View The bottom panel of the 8 10 100TX w Pro Ring Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm PWR2 FAULT PWR r 1AQ24V j 1 V2 V2 V1 V14 DC48V Bottom Panel of the industrial switch 2 4 LED Indicators The diagnostic LEDs that provide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for the switch The switch unit is power on The industrial switch is the master of X Ring group NT ee al The industrial switch is not a ring master in jor X Ring group m je 1 eee LONE et RN wow Se al a a C eA eee EE The port is transmitting or receiving packets inkin Upper LED 3 from the TX device Ea No device attached L LED On Off On Off On Off On Off On Off On Off On The SFP port is The SFP portis linking Link Active blaine NINE port is transmitting or receiving packets P9 P10 Green fro
47. ate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse the above steps 3 4 Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert AC or DC power wires into the contacts 1 and 2 for power 1 or 5 and 6 for power 2 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG 3 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG m E NUDO NN A A l The closed circuit will open whenthe l failure occurs oie Cet iic bn Seid is ERU Mf Fault Alarm Contacts 3 amp 4 3 6 Cabling W Use four twisted pair Category 5e or above cabling for RJ 45 port connection The cable between the switch and the link
48. ch config ring2 mode ring2 mode legacy ring G Enable legacy ring switch config ring2 mode legacy ring ring2 ringport G Configure Legacy switch config ring2 ringport 1 2 1st Ring Port 2nd Ring 1st 2nd Ring Port Ring Port ring2 mode x ring2 G Enable x ring2 switch config ring2 mode x ring2 ring2 add G Add x ring2 entry switch config ring2 add norm 1 1 pasv actv norm Ring ID 1st Ring Port 2nd Ring Port 1st Rdn Port 1st Rdn Port ID 2nd Rdn P ort 2nd Rdn Port ID normal type RID 1 1 port port 1 2 port port 2 1 rdn port port 3 1 rdn port ID 1 2 rdn port port 4 2 rdn port ID 1 23141 145 ring2 del G Delete ring2 entry switch config ring2 del 1 index ring2 show G Show X Ring2 switch config ring2 show configuration no ring2 G Disable X ring2 switch config no ring2 PoE Commands Set Commands Level Description Example P Enter POE configure switch poe poe mode system knockoff P Set PoE system Port switch poe system knockoff disabled Knockoff Disabled disabled disable Enable Disable system ac disconnect P Set PoE system AC switch poe system ac Enable Disable Disconnect disconnect disable system capacitive detect P Set PoE system switch poe system capacitive Enable Disable Capacitive Detection detect enable port PortNumbers state P Set PoE port State switch poe port 1 s
49. de stations will be different With the communicating programs running on those devices it would cause time to jump forward and back a non desirable effect Therefore the switch provides comprehensive mechanisms to access national time and frequency dissemination services organize the time synchronization subnet and the local clock in each participating subnet peer Daylight saving time DST is the convention of advancing clocks so that afternoons have more daylight and mornings have less Typically clocks are adjusted forward one hour near the start of spring and are adjusted backward in autumn BH SNTP Client Enable disable SNTP function to get the time from the SNTP server W Daylight Saving Time This is used as a control switch to enable disable daylight saving period and daylight saving offset Users can configure Daylight Saving Period and Daylight Saving Offset in a certain period time and offset time while there is no need to enable daylight saving function Afterwards users can just set this item as enable without assign Daylight Saving Period and Daylight Saving Offset again B UTC Timezone Universal Time Coordinated Set the switch location time zone The following table lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC Atlantic Standard 4 hours EDT Eastern Daylight 50 EST Eastern Standard 5 hours 7 am CDT Central Daylight CST Central
50. ected 7 5131 Static Trunking Group Group Key 2 Port Member Port 01 Port 02 Aggregation Information of Switch 1 5 Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured 66 WB Switch 2 configuration Port Trunk Aggregator Setting Aggregator Setting Aggregator Information State Activity System Priority 1 Group ID Trunk 1 7 Select Lacp fEnable Id Work Ports lt lt Add Remove gt gt Apply Delete Help Notice The trunk function do not support GYRP and X Ring Switch 2 configuration interface Set System Priority of the trunk group The default is 1 Select a trunk group ID by pull down the drop down menu bar Enable LACP Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically Port Trunk Aggregator Information s o ge x Aggregator Setting J Aggregator Information l State Activity Groupi Actor Partner Priority 1 1 MAC 000F38FFF501 001F3820820E PortNo Key Priority Active PortNo Key Priority 7 5131 selected 5 513 1 8 5131 selected 3 513 1 Aggregation Information of Switch 2 67 5 Click on the tab of Aggregator Information to check the trunked group information as the illustration shown above after the two switches configured 68 6 15 3 State Activity Having set up the LACP aggre
51. ed unicast bandwidth type Set interface ingress switch config interface 125 broadcast multicast limit frame type to accept broadcast and multicast frame fastEthernet 2 switch config if bandwidth type broadcast multicast bandwidth type broadcast only Set interface ingress limit frame type to only accept broadcast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast only bandwidth in Value Set interface input bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth in 100 bandwidth out Value Set interface output bandwidth Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth out 100 show bandwidth Show interfaces bandwidth control switch config interface fastEthernet 2 switch config if show bandwidth state Enable Disable Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command switch config interface fastEthernet 2 switch config if state Disable 126 to disable the port show interface configuration sho
52. egacy Ring 1st Ring Port 2nd Ring Port Port 01 Port a2 98 X Ring2 W Enable X Ring2 To enable the X Ring2 function tick the checkbox beside the X Ring2 Operation Mode string label If this checkbox is not ticked the ring functions are unavailable W Ring ID Set the Ring ID value to carry different RID frames to other switch m 1 amp 2 Ring Ports Pull down the selection menu to assign the ports as the member ports 1 Ring Port is the working port and 2 Ring Port is the backup port When 1 Ring Port fails the system will automatically upgrade the 2 Ring Port to be the working port Mode Normal Active passive 1 amp 2 Redundant Ports Pull down the selection menu to assign the ports as the member ports 1 Rnd Port is the working port and 2 Rnd Port is the backup port When 1 Rnd Port fails the system will automatically upgrade the 2 4 Rnd Port to be the working port m 1 amp 2 Redundant Ports ID Set the Rnd ID port value to carry different Rnd ID frames to other switch B And then click Ladd have the configuration take effect X Ring2 X Ring2 Operation Mode X Ring2 v X Ring2 Configuration Index Ring ID 1st Ring Port 2nd Ring Port Mode 1st Rdn Port 1st Rdn Port ID 2nd Rdn Port 2nd Rdn Port ID 1 1 Port 01 Port 02 NORM Port 09 1 Port i0 1 Ring ID 1st Ring Port 2nd Ring Port Mode 1st Rdn Port 1st Rdn Port ID 2nd Rdn Port 2nd Rdn Port ID NONE NONE w NORM v NONE NONE w
53. egator Setting J Aggregator Information State Activity Static Trunking Group Group Key 1 Port Member 12 Static Trunking Group information W Group Key This is a read only column field that displays the trunk group ID 63 B Port Member This is a read only column field that displays the members of this static trunk group 64 LACP enabled Having set up the aggregator setting with LACP enabled you will see the trunking group information between two switches on the tab of Aggregator Information WB Switch 1 configuration Set System Priority of the trunk group The default is 1 Select a trunk group ID by pull down the drop down menu bar Enable LACP Include the member ports by clicking the Add button after selecting the port number and the column field of Work Ports changes automatically me Ge qe Port Trunk Aggregator Setting Aggregator Setting Aggregator Information State Activity System Priority fi Group ID Trunk 1 Select Lacp Enable x Work Ports Port 03 Port 05 lt lt Add Remove gt gt Apply Delete Help Notice The trunk function do not support GYRP and X Ring Switch 1 configuration interface 65 Port Trunk Aggregator Information Aggregator Setting Aggregator Information j State Activity Groupi Actor Partner Priority 1 1 MAC 001F3820820E OOO0F3S8FFFS501 PortNo Key Priority Active PortNo Key Priority 3 513 1 selected 8 5131 5 513 1 sel
54. ess Link 1 802 1Q VLAN interface Group Configuration Edit the existing VLAN Group W Select the VLAN group in the table list B Click Edit 81 VLAN Configuration VLAN Operation Mode s0210 z MV Enable GVRP Protocol Management Wlan ID o Apply 802 1Q Configuration Delete Group Configuration interface W You can modify the VLAN group name and VLAN ID VLAN Configuration WLAN Operation Mode 802 19 Iv Enable GVRP Protocol Management Vian ID o Apply Group Name VLAN 3 VLANID f Apply Group Configuration interface B Click Apply 6 20 Rapid Spanning Tree The Rapid Spanning Tree Protocol RSTP is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol 6 19 1 RSTP System Configuration W Theuser can view spanning tree information of Root Bridge B Theuser can modify RSTP state After modification click Apply NOTE RSTP mode The user must enable the RSTP function first before configuring the related parameters Priority 0 61440 The switch with the lowest value has the highest priority and is selected as the root If the value is changed the user must reboot the switch The value must be a multiple of 4096 according to t
55. fine a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version IP Address Enter the IP address of the trap manager Community Enter the community string for the trap station Trap Version Select the SNMP trap version type v1 or v2c W Click Add m To remove the community string select the community string listed in the current managers field and click Remove SNMP Trap Configuration System Configuration Trap Configuration SNMPv3 Configuration Trap Managers Current Managers New Manager Remove Add 192 168 16 21 TrapHost v1 IP Address 192 168 16 23 192 168 16 22 TrapHost2 v2 Community TrapHost3 Trap version Help Trap Managers interface yi C v2c 89 6 20 3 SNMPV3 Configuration Configure the SNMP V3 function Context Table Configure SNMP v3 context table Assign the context name of context table Click Add to add context name User Table Configure SNMP v3 user table B User ID set up the user name W Authentication Password set up the authentication password m Privacy Password set up the private password B Click Add to add context name aa d B Click Remove to remove unwanted context name Group Table Configure SNMP v3 group table B Security Name User ID assign the user name that you have set up in user table WB Group Name set up the group name B Click Add to add co
56. g G Setunregister stream switch config igmp unregister flooding flooding igmp unregister G Set unregister stream switch config igmp unregister blocking blocking flooding show igmp P Displays the details of switch show igmp configuration configuration an IGMP configuration no igmp G Disable IGMP switch config no igmp snooping function no igmp query G Disable IGMP query switch no igmp query Multicast Filtering Commands Set Commands Level Description Example multicast filtering IP Addr Configure multicast filtering entry of interface Switch config interface fastEthernet 2 switch config if multicast filtering 228 1 1 1 no multicast filtering IP Addr Remove multicast filtering entry of Switch config interface fastEthernet 2 interface switch config if no multicast filtering 228 1 1 1 LLDP Commands Set Commands Level Description Example lldp enable G Enable LLDP function switch config lldp enable lidp interval Time sec G Configure LLDP switch config lldp interval 20 134 interval Mac Filter Table Commands Set Commands Level Description Example mac address table static 1 Configure MAC Switch config interface hwaddr address table of fastEthernet 2 MAC interface static switch config if mac address table static hwaddr 0000123
57. gator on the tab of Aggregator Setting you can configure the state activity for the members of the LACP trunk group You can tick or cancel the checkbox beside the state label When you remove the tick mark of the port and click Apply the port state activity will change to Passive Active The port automatically sends LACP protocol packets m Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device NOTE A link having two passive LACP nodes will not perform dynamic LACP trunk because both ports are waiting for an LACP protocol packet from the opposite device Port Trunk State Activity Aggregator Setting Aggregator Information State Activity Port LACP State Activity Port LACP State Activity 1 N A 2 N A 3 M Active 4 N A 5 M Active 6 N A 7 N A 8 N A 9 N A 10 N A Apply Help State Activity of Switch 1 69 Port Trunk State Activity Aggregator Setting 1 Aggregator Information State Activity Port LACP State Activity Port LACP State Activity 1 N A 2 N A 3 N A 4 N A 5 N A 6 N A 7 V Active E Iv Active E N A 10 N A Apply Help State Activity of Switch 2 70 6 16 Port Mirroring The Port mirroring is a method for monitor traffic in switched networks Traffic through ports can be monitored by one specific port which means traffic goes in or out monitored source ports will be duplicated into mir
58. ge rate If this charge rate is within the window of the PD signatures the device is considered to be discovered And then click Apply to carry into effect Port The index of PoE ports Enable State Check it to enable the PoE function to the port Power Limit From Check it to decide the power limit method gt Classification When this check box is ticked the system will limit the power supply to the powered device in accordance with the related class Legacy Check it to support the legacy power devices Priority Pull down the selection menu item to choose the priority of power supplying Port Limit lt 15400 mW User can key in the power limit value which is under 15 4 Watts Mode Displays the operating mode of the port Current mA Displays the operating current of the port Voltage V Displays the operating voltage of the port Power mW Displays the power consumption of the port Determined Class Displays the PD s class And then click Apply to carry into effect 112 6 29 Factory Default Reset switch to default configuration Click Default to reset all configurations to the default value Factory Default Iv Keep current IP address setting Iv Keep current username amp password Reset Help Factory Default interface 113 6 30 Save Configuration Save all configurations that you have made in the system To ensure the all configuration will be saved Click Save Flash to save the
59. gically are regarded as members of the same broadcast domain The valid VLAN ID is in the range of number between 1 and 4094 The amount of VLAN groups is up to 256 including default VLAN that cannot be deleted Each member port of 802 1Q is on either an Access Link VLAN tagged or a Trunk Link no VLAN tagged All frames on an Access Link carry no VLAN identification Conversely all frames on a Trunk Link are VLAN tagged Besides there is the third mode Hybrid A Hybrid Link can carry both VLAN tagged frames and untagged frames A single port is supposed to belong to one VLAN group except it is on a Trunk Hybrid Link The technique of 802 1Q tagging inserts a 4 byte tag including VLAN ID of the destination port PVID in the frame With the combination of Access Trunk Hybrid Links the communication across switches also can make the packet sent through tagged and untagged ports 78 802 1Q Configuration W Pull down the selection item and focus on 802 1Q then press Apply to set the VLAN Operation Mode in 802 1Q mode B Enable GVRP Protocol GVRP GARP VLAN Registration Protocol is a protocol that facilitates control of virtual local area networks VLANs within a larger network GVRP conforms to the IEEE 802 1Q specification which defines a method of tagging frames with VLAN configuration data This allows network devices to dynamically exchange VLAN configuration information with other devices For example having enabled GVR
60. h config monitor tx 3 show monitor Show port monitor information switch show monitor show monitor Show port monitor information switch config interface fastEthernet 2 switch config if show monitor no monitor Disable source port of monitor function switch config interface fastEthernet 2 switch config if no monitor 138 802 1x Commands Set Commands Level Description Example 8021x enable G Use the 802 1x global configuration command to enable 802 1x protocols Switch config 8021x enable words system nasid global configuration command to change the NAS ID 8021x system radiusip G Use the 802 1x Switch config 8021x system IP address system radius IP radiusip 192 168 1 1 global configuration command to change the radius server IP 8021x system serverport G Use the 802 1x switch config 8021x system port ID System server port serverport 1812 global configuration command to change the radius server port 8021x system G Use the 802 1x switch config 8021x system accountport system account port accountport 1813 port ID global configuration command to change the accounting port 8021x system sharedkey G Use the 802 1x Switch config 8021x system ID system share key sharedkey 123456 global configuration command to change the shared key value 8021x system nasid G Use the 802 1x switch conf
61. he protocol standard rule Max Age 6 40 The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The time that controls the switch to send out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forward Delay Time 4 30 The number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Follow the rule as below to configure the MAX Age Hello Time and Forward Delay Time 2 x Forward Delay Time value 1 gt Max Age value gt 2 x Hello Time value 1 83 RSTP System Configuration System Configuration l Port Configuration RSTP Mode Enable gt Priority 0 61440 22768 Max Age 6 40 20 Hello Time 1 10 Forward Delay Time 4 30 fis Priority must be a multiple of 4096 2 Forward Delay Time 1 should be greater than or equal to the Max Age The Max Age should be greater than or equal to 2 Hello Time 1 Help Apply Root Bridge Information Bridge ID 0080000F3800055E Root Priority 32768 Root Port Root Root Path Cost Max Age 20 Hello Time 2 Forward Delay 15 RSTP System Configuration interface 84 6 19 2 Port Configuration This web page provides the port configuration interface for RSTP You can assign higher o
62. he transmission power of the SFP default threshold and present value RX PWR Display the received power of the SFP default threshold and present value Off The port will be shut down when detecting the exceptional value E mail The port will send an e mail to administrator when detecting the exceptional value Port No Port 09 v High Alarm High Warning Status Low Warning Low Alarm C C oc ec Temperature m e 9C O off e mail O off e mail O off e mail O off e mail V V V V Voltage V O off e mail O off e mail O off e mail O off e mail Current Hs mA pg mA IA mA O off e mail O off e mail O off e mail O off e mail mi DAP mw mw TX PWR mW O off e mail O off e mail O off e mail off e mail mW mW m mW mW RX PWR mu O off e mail O off e mail O off e mail O off e mail 73 6 19 VLAN configuration A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which would allow you to isolate network traffic so only the members of the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN on a switch is logically equivalent of reconnecting a group of network devices to anothe
63. ig 8021x system nasid test1 139 8021x misc quietperiod sec Use the 802 1x misc quiet period global configuration command to specify the quiet period value of the switch Switch config 8021x misc quietperiod 10 8021x misc txperiod sec Use the 802 1x misc TX period global configuration command to set the TX period Switch config 8021x misc txperiod 5 8021x misc supptimeout Use the 802 1x misc Switch config 8021x misc sec supp timeout global supptimeout 20 configuration command to set the supplicant timeout 8021x misc Use the 802 1x misc Switch config 8021x misc servertimeout sec server timeout global configuration command to set the server timeout servertimeout 20 8021x misc maxrequest Use the 802 1x misc Switch config 8021x misc number max request global maxrequest 3 configuration command to set the MAX requests 8021x misc Use the 802 1x misc Switch config 8021x misc reauthperiod sec reauth period global configuration command to set the reauth period reauthperiod 3000 8021x portstate disable reject accept Use the 802 1x port state interface Switch config interface fastethernet 3 140 authorize configuration command to set the state of the selected port switch config if 8021x portstate accept show 8021x Displays a summary of the 802 1x pro
64. ing tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins switch config zspanning tree forward time 20 131 forwarding stp path cost 1 200000000 Use the spanning tree cost interface configuration command to set the path cost for Spanning Tree Protocol STP calculations In the event of a loop spanning tree considers the path cost when selecting an interface to place into the forwarding state switch config interface fastEthernet 2 switch config if stp path cost 20 stp path priority Port Priority Use the spanning tree port priority interface configuration command to configure a port priority that is used when two switches tie for position as the root switch switch config interface fastEthernet 2 switch config if stp path priority 128 stp admin p2p Auto True False Admin P2P of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge True 132 stp admin non stp I True False Admin NonSTP of STP priority on this switch config i
65. k With dynamic addressing a device can have a different IP address every time it connects to the network In some systems the device s IP address can even change while it is still connected DHCP also supports a mix of static and dynamic IP addresses Dynamic addressing simplifies network administration because the software keeps track of IP addresses rather than requiring an administrator to manage the task This means that a new computer can be added to a network without the hassle of manually assigning it a unique IP address The system provides the DHCP server function Having enabled the DHCP server function the switch system will be configured as a DHCP server 36 6 6 1 System configuration DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Low IP Address Type in an IP address Low IP address is the beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 16 100 192 168 16 200 In contrast 192 168 16 100 is the Low IP address High IP Address Type in an IP address High IP address is the end of the dynamic IP range For example dynamic IP is in the range between 192 168 16 100 192 168 16 200 In contrast 192 168 16 200 is the High IP address Subnet Mask Type in the subnet mask of the IP configuration Gateway Type in the IP address of the gateway in your network DNS Type in the Domain Name Server IP Address in
66. l Account fiohnadmin Password TREES Confirm Password TTE Rcpt e mail Address 1 supervisor amp 123 0m Rcpt e mail Address 2 Rcpt e mail Address 3 Rcpt e mail Address 4 CO Rcpt e mail Address 5 TT Rcpt e mail Address 6 Apply reto SMTP Configuration interface 46 6 8 3 System Event Log Event Configuration Having ticked the Syslog SMTP checkboxes the event log email alert will be sent to the system log server and the SMTP server respectively Also Port event log alert link up link down and both can be sent to the system log server SMTP server respectively by setting the trigger condition m System event selection There are 3 event types Device Cold Start Authentication Failure and X ring Topology Change The checkboxes are not available for ticking unless the Syslog Client Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first gt Device cold start When the device executes cold start action the system will issue the event log email alert to the system log SMTP server respectively Authentication Failure When the SNMP authentication fails the system will issue the event log email alert to the system log SMTP server respectively MAC Violation When the MAC address has violated the system will issue the event log email alert to the system log SMTP server respectively WB Port event selection Also before the drop down me
67. le Trunk Link A segment which provides the link path for one or more VLAN 79 aware devices switches A Trunk Port connected to the trunk link has an understanding of tagged frame which is used for the communication among VLANs across switches Which frames of the specified VIDs will be forwarded depends on the values filled in the Tagged VID column field Please insert a comma between two VIDs Note 1 A trunk port doesn t insert tag into an untagged frame and therefore the untagged 2 VID column field is not available It s not necessary to type 1 in the tagged VID The trunk port will forward the frames of VLAN 1 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the same Hybrid Link A segment which consists of Access and Trunk links The hybrid port has both the features of access and trunk ports A hybrid port has a PVID belonging to a particular VLAN and it also forwards the specified tagged frames for the purpose of VLAN communication across switches QinQ Double Tag VLAN configuration Double Tag VLAN is another mechanism employed in a Metro LAN in which it can save IP v4 address by residing groups of sub VLANs customer port in a VLAN Host and utilizing the default gateway IP address of Double Tag VLAN sharing the same IP subnet mask Double Tag VLAN in L2 provides enhances security between customer each home
68. m the TX device SFP No device attached A network device is detected The port is transmitting or receiving packets Green Blinking from the TX device P1 P8 NE No device attached The port is operating in full duplex mode Amber Blinking Collision of Packets occurs The port is in half duplex mode or no device is attached A powered device is connected utilizing Green FWD P1 Power over Ethernet on the port Green e No device is connected or power forwarding fails Chapter 3 Hardware Installation In this paragraph we will describe how to install the 8 10 100TX w Pro Ring Managed Ind ustrial Switch and the installation points attended to it 3 1 Installation Steps Unpack the Industrial switch Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If users want to wall mount the Industrial switch please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Categ
69. menting SNMP 6 20 1 System Configuration B Community Strings Here you can define the new community string set and remove the unwanted community string String Fill the name string RO Read only Enables requests accompanied by this community string to display MIB object information RW Read write Enables requests accompanied by this community string to display MIB object information and to set MIB objects gt Click Add gt To remove the community string select the community string that you defined before and click Remove The strings of Public RO and Private RW are default strings You can remove them but after resetting the switch to default the two strings show up again m Agent Mode Select the SNMP version that you want to use it And then click Change to switch to the selected SNMP version mode 87 SNMP System Configuration System Configuration Trap Configuration SNMPv3 Configuration Community Strings Current Strings New Community String Remove Add public RO String PString3 private RW PStringl RO RO CRW PString2 RW Agent Mode Current Mode SNMP V1 Vv2C only SNMP v1 v2c only C SNMP V3 only C SNMP Vi v2C v3 Change Help SNMP System Configuration interface 88 6 20 2 Trap Configuration A trap manager is a management station that receives the trap messages generated by the switch If no trap manager is defined no traps will be issued To de
70. mp community strings Community right RO RW Add SNMP community string Switch config snmp community strings public right rw snmp server host IP address community Configure SNMP server host information and switch config snmp server host 192 168 1 50 community public trap version v1 Community string community string remove trap version Switch config v1 v2c no snmp server host 192 168 1 50 snmpv3 context name Configure the context switch config snmpv3 context Context Name name name Test snmpv3 user Configure the Switch config snmpv3 user User Name group Group Name password Authentication Password Privacy Password userprofile for SNMPV3 agent Privacy password could be empty test01 group G1 password AuthPW PrivPW snmpv3 access context name Context Name group Group Name Configure the access table of SNMPV3 agent switch config snmpv3 access context name Test group G1 security level AuthPriv match rule Exact views V1 V1 V1 136 security level NoAuthNoPriv AuthNoP riv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name snmpv3 mibview view Configure the mibview switch config snmpv3 mibview View Name table of SNMPV3 view V1 type Excluded sub oid type agent 1 3 6 1 Excluded Included sub oid OID show snmp Show SNMP switch show snmp
71. n LED 8 port 10 100 Link Activity Green Full duplex Collision Amber SFP port LNK ACT Green 1000T LNK ACT Green 1000M Green External Power Supply DC 48V Redundant power DC 48V Power Supply and connective removable terminal block for master and slave power Power 116Watts Full load Consumption Operating ae 5 to 95 Non condensing Humidity Operating IES 2208C 20 C 60 C Temperature IES 2208C E 40 C 75 C Storage 40 C 85 C Temperature IP 30 72mm W x 105mm D x 152mm H Installation DIN rail and wall mount ear FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN 61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 n IEC60068 2 32 Free fall IEC60068 2 27 Shock Stability Testing OM IEC60068 2 6 Vibration 1 2 Software Features Management VLAN Port Trunk with LACP LLDP Pro Ring Il Quality of Service Class of Service Port Security SNMP v1 v2c v3 Web Telnet CLI RFC 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN MIB RFC 1643 RFC 1757 RSTP MIB Private MIB LLDP MIB Port Based VLAN IEEE 802 1Q Tag VLAN 256 entries VLAN ID Up to 4K VLAN ID can be assigned from 1 to 4094 GVRP 256 Groups LACP Port Trunk 4 Trunk groups Maximum 4 trunk members Supports LLDP allowing switch to advertise its identification
72. n Radius IEEE802 1ab LLDP Switch Back plane Switching Fabric 5 6Gbps Architecture Packet throughput ability Full Duplex 8 3Mpps 64bytes 14 880pps for Ethernet port Transfer Rate 148 800pps for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port MAC Address 8K MAC address table 10 100TX 8 x RJ 45 10 100 1000T Mini GBIC Combo 2 x RJ 45 2 x Connector 100 1000 SFP sockets RS 232 connector RJ 45 type 10Base T 2 pair UTP STP Cat 3 4 5 5E cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable Network Cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Distance Multi mode 0 to 5 km 1300 nm 50 125 um 800 MHz km 0 to 4 km 1300 nm 62 5 125 um 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 um 3 5 PS nm km 0 to 80 km 1550 nm 9 125 um 19 PS nm km Optical Fiber Min TX Output Multi mode 20 dBm Single mode 0 to 40 km 5 dBm 0 to 80 km 5 dBm Max TX Output Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 0 to 80 km 0 dBm Sensitivity 36 to 32 dBm Single mode 34 to 30 dBm Multi mode PoE pin RJ 45 port 1 8 support IEEE 802 3af End point assignment Alternative A mode Per port provides 15 4W ability Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 Per unit Power Green Power 1 Green Power 2 Green Fault Red Master Green FWD Gree
73. n accordance with the 8 4 2 1 policy rule gt Use a strict priority scheme Always the higher queue will be processed first except the higher queue is empty Priority Type There are 5 priority type selections available Port based TOS only COS only TOS first and COS first Disable means no priority type is selected W Click Apply to have the configuration take effect 93 QoS Configuration Qos Policy Use an 8 4 2 1 weighted fair queuing scheme C Use a strict priority scheme Priority Type Disable 7 _Apply Help Port based Priority Port 01 Port02 Port 03 Port 04 Port 05 Port 06 Port 07 Port 08 Port 09 Port 10 Lowest x Lowest z Lowest Lowest Lowest Lowest Lowest z Lowest x Lowest z Lowest z _Apply Help COS Priority 0 1l 2 3 4 9 6 y 4 Lowest z Lowest z Lowest Lowest z Lowest z Lowest Lowest z Lowest z Apply Help TOS Priority 0 1 2 3 4 9 6 Fi Lowest x Lowest x Lowest Lowest z Lowest v Lowest Lowest Lowest Priority 8 9 10 11 12 13 14 15 Lowest x Lowest z Lowest Lowest Lowest z Lowest Lowest z Lowest z Priority 16 17 18 19 20 21 22 23 Lowest v Lowest x Lowest Lowest z Lowest x Lowest Lowest z Lowest z Priority 24 25 26 27 28 29 30 31 Lowest x Lowest x Lowest x Lowest Lowest z Lowest Lowest z Lowest z Priority 32 33 34 35 36 37 38 39 EXEGODEDEG
74. ncluding a colon mark hour minute specification For example key in 20070701 02 00 and 20071104 02 04 in the two column fields respectively to represent that DST begins at 2 00 a m on March 11 2007 and ends at 2 00 a m on November 4 2007 B Daylight Saving Offset mins For non US and European countries specify the amount of time for day light savings Please key in the valid figure in the range of minute between 0 and 720 which means you can set the offset up to 12 hours B Synchronization Interval secs The Synchronization Interval is used for sending synchronizing packets periodically User can assign range from 64s to 1024s The default setting of values is 0 means that you disable the auto synchronizes feature 52 in SNTP client mode You can enable the feature when filling the interval range from 64s 1024s W Click Apply to have the configuration take effect SNTP Configuration SNTP Client Disable Daylight Saving Time Disable UTC Timezone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London x SNTP Server URL 0 0 0 0 Switch Timer Daylight Saving Period 20040101 00 0 20040101 00 0 Daylight Saving Offset mins lo Synchronization Interval secs lo Apply SNTP Configuration interface 53 6 11 IP Security IP security function allows the user to assign 10 specific IP addresses that have permission to manage the switch through the http and telnet services for the secu
75. ng an authentication step through which the client effectively logs in to the SMTP server during the process of sending e mail alert B Email Alert With this function being enabled the user is allowed to configure the detail settings for sending the e mail alert to the SMTP server when the events Occur SMTP Server IP Assign the mail server IP address when Email Alert is enabled this function will then be available W Sender Type in an alias of the switch in complete email address format e g switch101 123 com to identify where the e mail alert comes from WB Authentication Having ticked this checkbox the mail account password and confirm password column fields will then show up Configure the email account and password for authentication when this switch logs in to the SMTP server B Mail Account Set up the email account e g johnadmin to receive the email alert It must be an existing email account on the mail server m Password Type in the password for the email account Confirm Password Reconfirm the password Rcpt e mail Address 1 6 You can also fill each of the column fields with up to 6 e mail accounts to receive the email alert W Click Apply to have the configuration take effect 45 System Event Log SMTP Configuration Syslog Configuration J SMTP Configuration Event Configuration E mail Alert Enable x SMTP Server IP Address 192 168 16 5 Sender switch101 123 com Authentication Mai
76. nterface fastEthernet 2 interface switch config if stp admin non stp False show spanning tree E Displays a summary of switch gt show spanning tree the spanning tree states no spanning tree G Disable spanning tree switch config no spanning tree QOS Commands Set Commands Level Description Example qos policy G Select QOS policy switch config qos policy weighted fair strict scheduling weighted fair qos prioritytype G Setting of QOS priority switch config Zqos prioritytype port based cos type only tos only cos first tos first qos priority portbased G Configure Port based switch config qos priority ron Priority portbased 1 low lowest low middle high qos priority cos G Configure COS switch config qos priority cos 0 Prioriyillowestlowimid buggy middle qos priority tos G Configure TOS Priority switch config qos priority tos 3 Priority lowest low mid high dle high show qos P Displays the Switch show qos information of QoS configuration no qos G Disable QoS function switch config no qos IGMP Commands Set Commands Level Description Example 133 igmp enable G Enable IGMP switch config igmp enable snooping function Igmp query auto G Set IGMP query to switch config igmp query auto auto mode Igmp query force G Set IGMP query to switch config igmp query force force mode igmp unregister floodin
77. ntext name B Click Remove to remove unwanted context name 90 SNMP SNMPv3 Configuration System Configuration Trap Configuration I SNMPv3 Configuration Context Table Context Name Apply User Table Current User Profiles New User Profile Remove none User ID OSS Authentication Password Privacy Password Group Table Current Group content New Group Table Remove none A Security Name User ID Group Name Access Table Current Access Tables New Access Table Remove none Context Prefix Group Name C NoAuthNoPriv C AuthNoPriv Security Level M C AuthPriv Context Match Rule C Exact Prefix Read View Name Write View Name Notify View Name MIBView Table Current MIBTables New MIBView Table Remove none View Name SubOid Tree Type C Excluded Included Help Note Any modification of SNMPv3 tables might cause MIB accessing rejection Please take notice of the causality between the tables before you modify these tables SNMP V3 configuration interface Access Table Configure SNMP v3 access table Context Prefix set up the context name Group Name set up the group Security Level select the access level Context Match Rule select the context match rule Read View Name set up the read view Write View Name set up the write view Notify View Name set up the notify view 91 Add Add Add Add B Click Add to add context n
78. nu items are available the Syslog Client Mode selection item on the Syslog Configuration tab and the E mail Alert selection item on the SMTP Configuration tab must be enabled first Those drop down menu items have 3 selections Link UP Link Down and Link UP amp Link Down Disable means no event will be sent to the system log SMTP server Link UP The system will only issue a log message when the link up event of the port occurs Link Down The system will only issue a log message when the link down event of port occurs Link UP amp Link Down The system will issue a log message at the time when port connection is link up and link down 47 System Event Log Event Configuration Syslog Configuration l SMTP Configuration Event Configuration System event selection 7 Event Type l Syslog SMTP Device cold start Authentication Failure o MAC violation L1 Port event selection Port Syslog SMTP Port 01 Disable na Disable na Port 02 Disable v Disable v Port 03 Disable v Disable v Port 04 Disable Disable v Portos Meia Disable w Ciria tink umm Down ssec 0 3 NI Port 07 Disable Disable y Port 08 Disable i Disable v Port 09 Disable v Disable ra Port 10 Disable v Disable Event Configuration interface 48
79. ontent Chapteri Introduction d 1 14 Hardware Features ss 1 1 2 Software Features eenen 4 1 3 Package Content cceeeeeeeeeeeeeeeeees 7 Chapter 2 Hardware Description 8 2 1 Physical Dimension ssssssss 8 2 2 Front Panels ca ete eres 8 2 9 Bohom VIGW a ie or oes 9 24 BED IINGICAIONS over 10 Chapter 3 Hardware Installation 12 3 1 Installation Steps 12 3 2 DIN Rail Mounting eseseessss 13 3 3 Wall Mount Plate Mounting 15 3 4 Wiring the Power Inputs 16 3 5 Wiring the Fault Alarm Contact 17 3 9 dJXBDI IfIQ ood ssa eee 18 Chapter 4 Network Application 22 4 1 Pro Ring Il Application 24 4 2 Daisy Couple Ring eeeeeseesss 25 4 3 Multi Couple Ring 25 4 4 Advanced Dual Homing 25 Chapter 5 Console Management 27 5 1 Connecting to the Console Port 27 5 2 Pim ASsignmienl esce eek 27 5 3 Login in the Console Interface 28 5 44 CLI Management cccccccssseseeeeeeeeeeeeees 29 5 5 Commands Level c seses
80. ort Knockoff Disabled v AC Disconnect Vv Capacitive Detection Apply d Power Limit Current Voltage Power Determined 15400 Mode mA V mW Class mW v I Low 15400 Detecting 0 0 0 0 0 15 4W 2 ri I tow xj 15400 Detecting 0 0 0 0 0 15 4W v Oo r few x 15400 Detecting 0 0 0 0 0 15 4W e tow x 15400 Detecting o 0 0 0 0 15 4W v r r tow 15400 Detecting 0 0 0 0 0 15 4W 2 ri m tow 15400 Null 0 0 0 0 0 15 4W e Oo tow x 15400 Detecting 0 0 0 0 0 15 4W v r tow x 15400 Detecting 0 0 0 0 0 15 4W Apply PoE Status Actual Power Consumption This column shows the real time total power consumption Main Supply Voltage This column shows the output voltage of the system for PoE ports Firmware Version This column shows the PoE chip s firmware version Port Knockoff Disabled Power Management state where one or more PDs have been powered down so that a higher priority PD may be powered up and yet not exceed the maximum total power available for PDs AC Disconnect Tick this checkbox to monitor the AC impedance on the port terminals and removes power when the impedance rises above a certain value for a certain period for details see the IEEE 802 3af specification Capacitive Detection If the port and capacitive detection are enabled the capacitances state reads in the voltage result from the constant current This is then 111 subtracted from the pre capacitance voltage to get a char
81. ory 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port NOTE 7 RJ 45 port and another side of RJ 45 cable category 5 to the network device s Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication Make sure that the connected network devices support MDI MDI X If it does not support use the crossover category 5 cable When all connections are set and LED lights all show in normal the installation is complete 3 2 DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 First insert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Checkif the DIN Rail is tightened on the track or not 4 Toremove the industrial switch from the track reverse above steps 3 3 Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount pl
82. p daylight G Enable daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight sntp daylight period Start time End time Set period of daylight saving time if SNTP function is inactive this command can t be applied Parameter format yyyymmdd hh mm switch config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP Set SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone Set timezone index use show sntp switch config sntp timezone 22 144 timzezone command to get more information of index number sntp sync interval G Setsynchronization switch config sntp sync interval Secs interval 64 show sntp P Show SNTP switch show sntp information show sntp timezone P Show index number of switch show sntp timezone time zone list no sntp G Disable SNTP function switch config no sntp no sntp daylight G Disable daylight switch config no sntp daylight saving time Pro Ring Il Commands Set Commands Level Description Example ring2 mode G Select X ring2 mode swit
83. perties and also the port sates Switch gt show 8021x no 8021x Disable 802 1x function switch config no 8021x TFTP Commands Set Commands Level Description Defaults Example backup flash backup cfg G Save configuration to TFTP and need to specify the IP of TFTP server and the file name of image Switch config backup flash backup_cfg restore flash restore_cfg Get configuration from Switch config restore TFTP server and need tofflash restore cfg specify the IP of TFTP server and the file name of image upgrade flash upgrade_fw Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image Switch config upgrade flash upgrade_fw SystemLog SMTP and Event Commands Set Commands Level Description Example 141 systemlog ip IP address Set System log server IP address Switch config systemlog ip 192 168 1 100 systemlog mode client server both Specified the log mode switch config systemlog mode both show systemlog Displays system log Switch gt show systemlog show systemlog Show system log client amp server information switch show systemlog no systemlog Disable systemlog switch config no systemlog functon smtp enable Enable SMTP function switch config smtp enable smtp serverip
84. ports within the logical channel or so called logical aggregator work at the same connection speed and LACP operation requires full duplex mode 6 15 1 Aggregator setting m System Priority A value which is used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP peer of the trunk group W Group ID There are 13 trunk groups to be selected Assign the Group ID to the trunk group m LACP When enabled the trunk group is using LACP A port which joins an LACP trunk group has to make an agreement with its member ports first Please notice that a trunk group including member ports split between two switches has to enable the LACP function of the two switches When disabled the trunk group is a static trunk group The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports but member ports won t know that they should be aggregated together to form a logic trunk group B Work ports This column field allows the user to type in the total number of active port up to four With LACP static trunk group e g you assign four ports to be the members of a trunk group whose work ports column field is set as two the exceed ports are standby redundant ports and can be aggregated if working ports fail If it is a static trunk group non LACP the number of work ports must equal the total number of group member ports W
85. r Layer 2 switch However all the network devices are still plugged into the same switch physically This switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable VLAN Configuration VLAN Operation Mode Disable v Enable GVRP Protocol Management Vlan ID Apply VLAN NOT ENABLE VLAN Configuration interface 74 6 18 1 Port based VLAN A port based VLAN basically consists of its members ports which means the VLAN is created by grouping the selected ports This method provides the convenience for users to configure a simple VLAN easily without complicated steps Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored The port based VLAN function allows the user to create separate VLANs to limit the unnecessary packet flooding however for the purpose of sharing resource a single port called a common port can belongs to different VLANs which all the member devices ports in different VLANs have the permission to access the common port while they still cannot communicate with each other in different VLANs VLAN Configuration VLAN Operation Mode Port Based l Enable GVRP Protocol Management Vlan ID o Add Edit Delete Help VLAN Port Based interface W Pull down the selection item and focus on
86. r lower priority to each port Rapid spanning tree will have the port with the higher priority in forwarding state and block other ports to make certain that there is no loop in the LAN Select the port in the port column field Path Cost The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200 000 000 W Priority Decide which port should be blocked by setting its priority as the lowest Enter a number between 0 and 240 The value of priority must be the multiple of 16 WB Admin P2P The rapid state transitions possible within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means the port is regarded as a point to point link False means the port is regarded as a shared link Auto means the link type is determined by the auto negotiation between the two peers WB Admin Edge The port directly connected to end stations won t create bridging loop in the network To configure the port as an edge port set the port to True status B Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation W
87. remote system log server with its IP assigned If the mode is set in Both the system event log will be sent to the remote server and this interface B System Log Server IP Address When the Syslog Mode item is set as Server Only Both the user has to assign the system log server IP address to which the log will be sent W Click Reload to refresh the event log displaying area W Click Clear to clear all the current event logs B Make sure the selected mode is correct and click Apply to have the setting take effect 43 System Event Log Syslog Configuration SMTP Configuration l Event Configuration Syslog Client Mode Both y E I sn J Apply Syslog Server IP Address 192 168 16 200 3 Jan 1 00 02 53 System Log Server IP 192 168 16 200 2 Jan 1 00 02 53 System Log Enable 1 Jan 1 00 02 18 Clear System Log Table Reload clear Hep Syslog Configuration interface 44 6 8 2 System Event Log SMTP Configuration Simple Mail Transfer Protocol SMTP is the standard for email transmissions across the network You can configure the SMTP server IP mail subject sender mail account password and the recipient email addresses which the e mail alert will send to There are also five types of event Device Cold Start Authentication Failure X Ring Topology Change and Port Event available to be issued as the e mail alert Besides this function provides the authentication mechanism includi
88. res show the 10 100Base TX cable schematic Switch Router or PC 3 TD 3 RD 6 TD 6 RD RDc 1 TD 2 RD 2 TD Straight through cable schematic Switch Switch 3 TD 3 TD 6 TD 6 TD RD RD 2 RD 2 RD Cross over cable schematic B 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs Pin Label 123458678 TPO TP TRi TP24 TPZ TPI TPs TP3 Eh y Xm mn hb ki nm B 10 100 1000Base TX Cable Schematic 118 Switch Router cc PC TP14 TP1 TPO TPO ge c m 3 gom 4 TP3 TP2 4 5 TP3 TP3 e T TP2 TP3 amp TPA oc on p Straight through cables schematic Switch Switch 1 TPO 1 TPO 2 TPO 2 TPO 3 TP1 a TP1i amp TPi1 amp TP1 4 TP24 4 TP2 5 TP2 5 TP2 7 TP3 7 TP3 a TP3 a TP3 Cross over cables schematic 119 RJ 45 Pin Assignment of PoE With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data pins 4 5 7 and 8 are used for power supplying B Pin out of Cisco non 802 3af standard PD Pin Signal RX RX TX VCC VCC TX VCC VCC O Oo 5 oO DN WB Pin out of PoE Midspan Hub Switch Pin Signal Name RX RX TX VCC VCC TX VCC VCC co N OO A C N
89. ring switch management The purpose of giving the limited IP addresses permission is to allow only the authorized personnel device can do the management task on the switch m IP Security Mode Having set this selection item in the Enable mode the Enable HTTP Server Enable Telnet Server checkboxes and the ten security IP column fields will then be available If not those items will appear in grey B Enable HTTP Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via HTTP service B Enable Telnet Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via telnet service WB Security IP 1 10 The system allows the user to assign up to 10 specific IP addresses for access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet service once IP Security Mode is enabled W Andthen click Apply to have the configuration take effect NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when the switch powers off 54 IP Security IP Security Mode Enable Iv Enable HTTP Server M Enable Telnet Server Security IP1 192 168 16 11 Security IP2 192 168 16 21 Security IP3 192 168 16
90. ror destination port W Destination Port There is only one port can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only User can connect mirror port to LAN analyzer or Netxray W Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port User can select multiple source ports by checking the RX or TX check boxes to be monitored B Andthen click Apply button Port Mirroring Destination Port Source Port RX TX RX TX Port 01 e C Iv Iv Port 02 Iv Iv Port 03 C C Iv O Port 04 C C C Iv Port 05 C C Iv E Port 06 C C Iv Iv Port 07 C Iv Iv Port 08 C C Iv E Port 09 e C E Iv Port 10 C C Iv O Apply Help Port Trunk Port Mirroring interface 71 6 17 Rate Limiting You can set up every port s bandwidth rate and frame limitation type Ingress Limit Frame type select the frame type that wants to filter There are four frame types for selecting Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type All the ports support port ingress and egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs
91. seeeeeeeeeeeeeeaees 29 Chapter 6 Web Based Management 31 6 1 About Web based Management 31 6 2 Preparing for Web Management 31 6 3 System Login sssesessss 32 6 4 System Information sssesssss 33 6 5 IP Configuration eset rne tenet Bone 34 6 5 DHCP Server 2 oido ence etes 36 6 6 1 System configuration ssss 37 0 0 2 Client Entries Saee sul acct canst het toe diras 38 6 6 3 Port and IP Bindings sod peior rna 39 o TPIP i EM mM 40 6 7 1 Update Firmware cesses 40 6 7 2 Restore Configuration sssssss 41 6 7 3 Backup Configuration ssssss 42 6 8 System Event Log 43 6 8 1 Syslog Configuration ecc toi eot 43 6 8 2 System Event Log SMTP Configuration 45 6 8 8 System Event Log Event Configuration 47 6 9 Fault Relay Alarm ssss 49 6 10 SNTP Configuration essuss 50 Bod IP SOQUEI siia iore nien teo aa testes 54 6 12 User Authentication ssssss 56 6 13 Port Statistics 4 io epo cibi Doo Yct 57 6 14 Port Control o rct 59 p 15 POM TUNK eni ied ates mE ie Dada sort 61 6 15 1 Aggregator setting eeeessseusssss 61 6 15 2 Aggregator Information
92. ssign a static trunk switch config Zaggregator group GroupID Port list group 1 2 4 nolacp nolacp GroupID 1 3 or Port list Member port switch config aggregator group list This parameter 1 3 1 2 nolacp could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 show aggregator P Show the information switch show aggregator 1 of trunk group or switch show aggregator 2 or switch show aggregator 3 no aggregator lacp G Disable the LACP switch config no aggreator lacp GroupID function of trunk group 1 no aggregator group G Remove a trunk group switch config no aggreator GroupID group 2 VLAN Commands Set Commands Level Description Example vlan database P j Enter VLAN configure switch vlan database mode Vlanmode portbase 802 1q To set switch VLAN mode switch vlan vlanmode portbase or 128 gvrp switch vlan vlanmode 802 1q or switch vlan vlanmode gvrp no vian V No VLAN Switch vlan no vlan Ported based VLAN configuration vlan port based V Add new port based switch vlan Zvlan port based grpname VALN grpname test grpid 2 port 2 4 Group Name or grpid switch vlan vlan port based GroupID grpname test grpid 2 port 2 3 4 port PortNumbers show vlan GroupID V Show VLAN switch vlan show vlan 23 s information show vlan no vlan group V Delete port base switch vl
93. stance W f the LED indicators are normal and the connected cables are correct but the packets still cannot be transmitted Please check the user system s Ethernet devices configuration or status 116 Appendix A RJ 45 Pin Assignment RJ 45 Pin Assignments The UTP STP ports will automatically sense for Fast Ethernet 10Base T 100Base TX connections or Gigabit Ethernet 10Base T 100Base TX 1000Base T connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schematic B 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data B RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx NOTE and signs represent the polarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Ol GW N Transmit Data plus TD Receive Data plus RD Transmit Data minus TD Receive Data minus RD 117 B 10 100Base TX Cable Schematic The following two figu
94. t loop and form path recovery architecture et 3 Backup Path Ld t Ld t Fackup Path Gackup Path 4 3 Multi Couple Ring For multiple ring groups it helps to structure ring activities among different LANs Each ring group has more than 3 redundant paths for backup 4 4 Advanced Dual Homing When the ring group is connected to upper switch by RSTP algorithm it strengths the uplink connection with its own redundant path which double secures the link than of traditional Dual Homing NOTE In Advanced Dual Homing application architecture the upper level switches need to enable the Rapid Spanning Tree protocol 25 RSTP Backup Path Pro Ring II Backup Path X Ring Il i Advance Recovery time table i Dual Homing Ring Port 10ms Dual Homing Port 300s Ring Port 10ms Recovery Time ms ing 1 F RRNA Dual Homing Port 300s 26 Chapter 5 Console Management 5 1 Connecting to the Console Port The supplied cable which one end is RS 232 connector and the other end is RJ 45 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program IO m m L mmm A I Jii il CI EE To the console port of To PC or Terminal the Industrial Switch a DB 9 pin Female 5 2 Pin Assignment DB9 Connector RJ 45 Connector 1
95. tate disable Enable Disable port PortNumbers plfc P Set PoE port Power switch poe port 1 plfc enable Enable Disable Plait irem Classification port PortNumbers P Set PoE port Legacy switch poe port 1 legacy enable legacy Enable Disable port PortNumbers P Set PoE port Priority switch poe port 1 priority high priority Low High Critical port PortNumbers P Set PoE port Power switch poe port 1 powerlimit powerlimit Value Limit Value 15300 P show poe Show setting of PoE function switch show poe 146
96. the ingress rate by packet counter to meet the All Broadcast Multicast Flooded Unicast Broadcast Multicast Broadcast only Rate Limiting Ingress Limit Frame Type Ingress Egress Port 01 all o kbps o kbps All Port 02 Broadcast Multicast Flooded Unicast 0 kbps JO kbps Port 03 Broadcast Multicast o kbps o kbps Port 04 a xs m kbps o kbps Port 05 a el D kbps D kbps Portos v wbps lo kbps Porto7 Al vj o wops o kbps Port 08 a el D kbps D kbps Port 09 fri el D kbps D kbps Port 10 a e D kbps D kbps Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga ports and zero means no limit Heip Rate Limiting interface specified rate 72 gt Ingress Enter the port effective ingress rate The default value is O gt Egress Enter the port effective egress rate The default value is 0 m And then click Apply to apply the settings 6 18 DMI Diagnostic Monitoring Interface for SFP module User can monitor the SFP module and set up the action when detecting the exceptional value Port No Specify the SFP port and show the SFP module information Temperature Display the internal temperature of the SFP default threshold and present value Voltage Display the supply voltage of the SFP default threshold and present value Current Display the Bias current of the SFP default threshold and present value TX PWR Display t
97. thernet 3 Down Both switch config if amp event smtp both show event P Show event selection switch show event no event device cold G Disable cold start switch config no event device start event type cold start no event authentication G Disable Authentication switch config no event failure failure event typ authentication failure no event ring topology G Disable X ring switch config no event ring change topology changed topology change event type no event systemlog Disable port event for switch config interface system log fastethernet 3 switch config if no event systemlog no event smpt Disable port event for switch config interface SMTP fastethernet 3 switch config if no event smtp show systemlog P Show system log switch show systemlog client amp server information Fault Relay Alarm Commands Set Commands Level Description Example faultrelay power G Configure Relay Alarm for Power Failure switch config faultrelay power 1 143 faultrelay enable disable Configure Relay Alarm for Port Link Down Broken switch config interface fastethernet 3 switch config if faultrelay enable no faultrelay Disable Fault Relay Alarm Function switch config no faultrelay SNTP Commands Set Commands Level Description Example sntp enable G Enable SNTP function switch config sntp enable snt
98. tic device Field Automatic device Field Automatic device 22 The illustration below shows an example of power over Ethernet application Uplink via Fiber Uplink via UTP STP PoE Industrial Switch Power over Ethemet Power over Ethernet m Power over Ethemet Power over Ethernet PoE Splitter Power over Ethernet Ethernet Cable c n PoE Splitter zz b VOIP Phone IP Camera Wireless AP IEEE 802 3af Compliant Powered Devices Power Cable Ethernet Cable Non PoE Devices 23 4 1 Pro Ring ll Application Pro Ring Il is a new Ring mechanism for Lantech Industrial Switches in which it eliminates the need to pre set the Master switch in old Pro Ring and yet to protect the network by much secure topologies than ever Pro Ring Il works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier Pro Ring Il can be backward compatible with old Pro Ring by down grading the Ring scheme to old one Data collect server Enterprise Switch Field Management Industrial 4 Switch Programmable logic controller Distribute I O control system Serial Device Server Field Automatic device Field Automatic device Field Automatic device 24 4 2 Daisy Couple Ring For larger and single LAN group Daisy Couple Ring could achieve self recovery time in less than 10ms in which the ring group will choose automatically for Master switch detec
99. tication fails and the authentication session ends W Reauth period Set the period of time which clients connected must be re authenticated B Click Apply 802 1x Radius Misc Configuration System Configuration Port Configuration Misc Configuration Quiet Period lo Tx Period o Supplicant Timeout 0o Server Timeout o Max Requests D Reauth Period 3600 Apply Help 802 1x Misc Configuration interface 105 6 27 MAC Address Table Use the MAC address table to ensure the port security 6 27 1Static MAC Address You can add a static MAC address that remains in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again Via this interface you can add modify delete a static MAC address Add the Static MAC Address You can add static MAC address in the switch MAC table here B MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity W Port No Pull down the selection menu to select the port number B Click Add W f you want to delete the MAC address from filtering table select the MAC address and click Delete 106 MAC Address Table Static MAC Addresses Static MAC Addresses MAC Filtering All Mac Addresses Multicast Filtering
100. unk V Assign a hybrid link for switch vlan zivlan 8021q trunk 3 PortNumber ar hybrid link untag VLAN by trunk group hybrid link untag 4 tag 3 6 8 UntaggedVID or tag Tagged VID List switch vlan vlan 8021q trunk 3 hybrid link untag 5 tag 6 8 show vlan GroupID V Show VLAN switch vlan show vlan 23 information show vlan no vlan group V Delete port base switch vlan no vlan group 2 GroupID group ID Spanning Tree Commands Set Commands Level Description Example spanning tree enable G Enable spanning tree switch config spanning tree enable spanning tree priority G Configure spanning switch config spanning tree 0 61440 tree priority parameter priority 32768 spanning tree max age G Use the spanning tree switch config spanning tree seconds max age global configuration command to change max age 15 130 the interval between messages the spanning tree receives from the root switch If a switch does not receive a bridge protocol data unit BPDU message from the root switch within this interval it recomputed the Spanning Tree Protocol STP topology spanning tree hello time seconds Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs switch config zspanning tree hello time 3 spanning tree forward time seconds Use the spann
101. w interface configuration status switch config interface fastEthernet 2 switch config if show interface configuration show interface status show interface actual status switch config interface fastEthernet 2 switch config if show interface status show interface accounting show interface statistic counter switch config interface fastEthernet 2 switch config if show interface accounting no accounting Clear interface accounting information switch config interface fastEthernet 2 switch config if amp no accounting Trunk Commands Set Commands Level Description Example aggregator priority G Set port group system switch config aggregator priority 1 65535 priority 22 aggregator activityport G Set activity port switch config aggregator Group ID activityport 2 Port Numbers aggregator group G Assign atrunk group switch config aggregator group GroupID Port list lacp workp Workport with LACP active GroupID 1 3 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 127 comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports aggregator group G A

Download Pdf Manuals

image

Related Search

Related Contents

    VW GENO 03 27 kVA  SUPPORT.NINTENDO.COM SUPPORT.NINTENDO.COM  LCD-32XH4 LCD-32XH4B LCD-37XH4 LCD-42XH4  BDL4271VL BDL4671VL  MANUAL DE INSTRUCCIONES ESP AÑOL  Conseils pour la rédaction du projet  LaCie 12big Rack Storage Server  Manual - WIKA Worldwide  

Copyright © All rights reserved.