1. Thermo switch open A failure has occurred in the heating sys tem The remote control or its connections are faulty No fluid in the bottle The pump system is not primed The output control is not set high enough An electronic failure has occurred An electronic failure has occurred Magnum 1000 user manual Connect remote to the DIN socket on the top of the machine Switch on Replace fuse Reset thermo switch Refer the problem to a qualified technician Replace the remote control Replace or refill the bottle with Martin fog fluid Set the output level control to maximum and hold down the Fog button for 15 sec onds Increase the output level setting Refer the problem to a qualified technician Refer the problem to a qualified technician 1997 Martin Professional A S appendix SPECIFICATIONS HEAT EXCHANGER PowerconsumptionUK Europe 750 W 240 V PowerconsumptionUSA 750 W 120V Construction Copper vaporizing coil in cast aluminum with integral heater Operatingtemperature m m enken nen n enes 300 C maximum Overheating protection Direct contact thermo switch with manual reset FUSE URE ge e e 5 A time delay T 5 mm x 20 mm USA Liu EEE NE 10 A time delay T 5 mm x 20mm ELECTRICAL Input power UK Europe rrnnrnnnnnnnnnnnenrrnnnnnnn
2. smoke machine at least 60 cm 2 feet out of people s reach Do not tilt or stand the smoke machine or rig it in the air above people s heads Plugging in the remote control The remote must be plugged into the smoke machine in order for it to operate Locate the 5 pin DIN socket on top of the smoke machine and plug in the remote control cable 6 Magnum 1000 user manual 1997 Martin Professional A S section 3 OPERATION Switching the smoke machine on and off 1 Before switching the machine on set the timer control on the remote to the off position Make sure there is fluid in the bottle With the smoke machine plugged in set the power switch on the back of the smoke machine to 1 The HEATING LED on the remote will light up The machine will take approximately 10 minutes to reach operating temperature at which point the READY LED will light up To turn off the machine switch the power switch to the O position Set the timer control to the off position Making fog manually When the READY LED is lit press the FOG button on the remote control to make fog The output level may be adjusted using the level control During longer runs output decreases automatically as the heat exchanger cools Making fog automatically Fog output may be automatically controlled using the built in timer 1 TIR ON Turn on the machine and wait for the READY LED to light up To turn on the timer rotate the
3. Magnum 1000 user manual 1997 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark Revision 970911 MA 1997 Martin Professional A S section 1 INTRODUCTION The Magnum 1000 is a compact and efficient smoke machine that utilizes a water based fluid with an aluminum and copper heat exchanger to create a white fog for entertainment and theatrical use Quality materials and inno vative design combine to give ease of use and long service life Please read this manual thoroughly before operating the machine The Magnum 1000 features 1 liter fluid container 750 W heating element Long life copper and aluminum heat exchanger Electronic pump control for maximum run times Remote control with variable timer and output controls 5 meter remote cable Fail safe overheating protection with manual reset Compact size and light weight Power ON OFF switch Using the smoke machine safely Do not install the smoke machine above people s heads Do not restrict the ventilation on the machine Operating the machine in areas with poor ventilation may lead to condensation forming on surfaces and floors THIS CAN BE DANGEROUS Keep the output of the machine at least 60 cm 2 feet away from people and surfaces Do not point the machine into people s faces Never remove t
4. he cover without first disconnecting the machine from the power supply The output nozzle at the front of the machine is very hot and must not be touched Observe the warnings printed on the machine Do not use the machine if it is in poor or unsafe condition e g if the power cable is damaged Always use genuine Martin fluid in the machine other fluids may be dangerous Never run the smoke machine unattended Never replace the fuse with one of a higher rating Never operate the machine with the overheating protection disabled Magnum 1000 user manual 3 section 2 INSTALLATION front view side view 0 EN 172 mm i AA AAA 418 mm NE top view rear view fluid bottle E J power switch GIN DD oc remote socket IEC power i 4 cable socket FE Magnum 1000 user manual 1997 Martin Professional A S Included with the Magnum 1000 The smoke machine is delivered with remote control E C power cable 1 liter fluid bottle empty user manual Installing the fluid bottle WARNING Use Martin fog fluid only This fluid is manufactured specially for Martin smoke machines Other fluids may clog the heating element or cause the machine to spit hot
5. liquid from the nozzle Disconnect the machine from AC power before installing the fluid bottle 1 Place the bottle of Martin fluid into the fluid compartment and screw on the cap with fluid pipe Make sure the pipe reaches the bottom of the bottle Remove the fluid bottle from the machine when refilling If the machine has not been used recently or has been run dry it may be necessary to prime the pump Set the level control on the remote to 10 and press the fog button for 10 15 seconds when the machine is at operating temperature Connecting to the power supply WARNING This machine must be grounded The Magnum 1000 is delivered from the factory without a plug on the power cable A suitable plug one that fits your local wall outlet must be installed before you can connect the machine to the AC power supply Magnum 1000 user manual 5 Connect the wires to the plug as follows 1 Connect the green yellow wire to the ground earth connection 2 Connect the blue wire to the neutral connection 3 Connect the brown wire to the live phase connection IMPORTANT Check the rating label on the machine to make sure that the rated voltage and frequency match the local supply Plug the power cable into the power inlet on the back of the smoke machine and then into the wall outlet Placing the smoke machine Place the Magnum 1000 with the rubber feet down in contact with the floor or a level and stable surface Place the
6. nnnnnnnnnrnnnennsnenneernnennnnennnne 730 W 230 V Input power USA ED ED da HE Eee fl mas rede 730 W 115 V CONTROL SYSTEM Type ers TEST Electronic Temperaturesensor 1 1 aaa Thermocouple OPERATING ENVIRONMENT Ambient temperature range uu s4unannnnnnnnnnnnnannnnnnnnn m 0 to 40 C DIMENSIONS LengtihxWidtihxHeight 418 x 241 x 172 mm 16 5 x 9 5 x 7 4 in Weight with liter Mid iseyen ee nee den bn et 6 kg 13 2 Ib Magnum 1000 user manual 11 Martin Professional A S Nordlandsvej 114 DK 8240 Risskov Denmark Phone 45 87 42 88 88 WWW http www martin dk
7. th a damp cloth Do not use solvents to clean the machine as this may remove the silk screen printing Keep the cables in good condition ACCESSING THE FUSE AND THERMO SWITCH 1 Allow the smoke machine to cool completely and disconnect the smoke machine from the power supply 2 Remove the fluid bottle 3 Remove 4 Philips head screws from each end of the case 4 Slide the cover forward off the machine REPLACING THE FUSE 1 Disconnect the machine and remove the cover as described above 2 Locate the fuse on the printed circuit board 3 Replace the fuse with one of the same size and rating See specifications 4 Replace the cover RESETTING THE THERMO SWITCH 1 Disconnect the machine and remove the cover as described above 2 Locate the thermo switch It is placed above the heat exchanger towards the front of the machine 3 Press the thermo switch to reset 4 Replace the cover Magnum 1000 user manual 9 section 5 TROUBLESHOOTING Symptom WARNING Always disconnect the machine from the power supply and allow it to cool before removing the cover Probable Cause Remedy No LEDs come on when power is applied to the machine The machine never reaches operating temperature READY LED never lights No smoke is produced when the Fog but ton is pressed The fuse continually blows or the thermo switch continually trips Remote control not connected Main power switch is off Main fuse blown
8. timer control clockwise until the green TIMER LED lights up Adjust the pulse rate The rate is highest when the timer control is set to 10 Adjust the output level The level is highest when the level control is set to 10 Periodically check the fog fluid level IMPORTANT Avoid operating the smoke machine without fog fluid as this can cause damage to the seals Magnum 1000 user manual 7 Using the remote control TIMER LED TIMER Control When lit the timer is on and the smoke Turn clockwise until the TIMER LED lights up machine makes fog at regular intervals to turn on the timer Turn off for manual oper ation Pulse rate highest when set to 10 TIMER 456 3 7 2 8 ES 9 GFE 10 READY LED FOG Button When lit the smoke machine is at G Press to make fog manually The READY operating temperature TIMER FO LED must be lit READY HEAT 456 HEAT LED 5 gg LEVEL Control When lit the machine is heating up 1 9 Adjust fog output level Output is highest The LED goes off when the operating 0 10 when setto 10 temperature is reached LEVEL 8 Magnum 1000 user manual 1997 Martin Professional A S section 4 MAINTENANCE WARNING Always unplug the machine from the power supply and allow it to cool completely before opening the machine or performing any maintenance REGULAR MAINTENANCE If fluid is spilled onto the machine clean it wi