1. Wall Jack Bw 495 14579 01 Refer to the Verifying the V 32 DBM Hardware Settings section in the DBM Supplement for hardware strap details February 1996 2 3 COMSPHERE 3600 Data Service Units Switched 56 kbps Network Connection WARNING Do not insert the 2 wire switched 56 kbps plug into an RJ11C jack providing PSTN service This type of jack is intended for analog public switched telephone network PSTN devices Doing so may cause equipment damage and harm to the telephone network To make a physical connection to the switched 56 kbps network 7 Procedure 1 Plug one end of the switched 56 kbps network interface cable into the DSU jack labeled BACKUP Verify that you have the right cable For a DSU with a Usethe 2 wire Switched 56 DBM 6 pin cable 4 wire Switched 56 DBM 8 pin cable 2 Plug the other end of the cable into the modular jack provided for the switched 56 kbps network connection Switched 56 kbps Network Connection 74 E A ne A tr e d Wall Jack N 495 14860 2 4 February 1996 ISDN DBM Network Connection The 2 wire ISDN DBM has an integral Network Termination 1 NT1 The NT1 provides the termination of the ISDN U interface from the network To make a physical connection to the ISDN network U interface L7 Procedure 1 Plug one end of the ISDN network interface cable into the DSU jack labeled BACKUP 2 Plug the other end of the cab
2. 1 68 kg 1 34 pounds 0 61 kg 1 05 pounds 0 48 kg 1 50 pounds 0 68 kg 0 13 pound 0 06 kg 70 00 pounds 31 8 kg February 1996 1 3 COMSPHERE 3600 Data Service Units Table 1 2 DSU Technical Specifications APPLICATION Full or half duplex data transmission via point to point or multipoint DDS network or local area data channel COMMUNICATION LINE Leased or private 4 wire DDS line DATA RATES Digital Services DDS ASDS LADS Clear Channel When timing is external provided by the DTE the DTE s clock must be within these ranges DDS NETWORK INTERFACE 3610 DSU 3611 DSU DIAGNOSTIC INTERFACE 3610 DSU 3611 DSU NETWORK COMPATIBILITY ANSI T1 410 1992 and AT amp T Technical Reference 62310 1987 Integrated Network Corporation Compatibility Bulletin CB INC 101 and Pacific Bell publications PUB L 780035 PB NB and PUB L 780036 PB NB DSU COMPATIBILITY Primary Channel Diagnostic Channel Point to Point or Multipoint Point to Point Only 2 4 4 8 9 6 19 2 38 4 56 and 64CC kbps 2 4 4 8 9 6 19 2 38 4 56 and 64 kbps 64 kbps on a 72 kbps circuit with the 64KScrambling configuration option enabled 64CC kbps 56 kbps 38 4 kbps 19 2 kbps 9 6 kbps 4 8 kbps 2 4 kbps 11 bps 9 bps 4 bps 5 bps 1 bps 0 bps 0 bps 8 pin modular jack USOC 485 One or two 50 pin connector USOC RJ48T Requires 3600 Hubbing Device which provides two 8 pin modular
3. You have accessed an older version of a Paradyne product document Paradyne is no longer a subsidiary of AT amp T Any reference to AT amp T Paradyne is amended to read Paradyne Corporation AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo Florida has changed from 813 to 727 For any Paradyne telephone number that appears in this manual with an 813 area code dial 727 instead 1 AT amp I Paradyne COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Documentation Replacement Document No 3610 A2 GB43 40 Feature No 3600 G3 002 COMSPHERE 3600 Series Data Service Units COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Documentation Replacement 3610 A2 GB43 40 Feature No 3600 G3 002 5th Edition February 1996 Changes and enhancements to the product and to the information herein will be documented and issued as a new release Address comments to AT amp T Paradyne Corporation Technical Publications 8545 126th Avenue North Box 2826 Largo Florida 34649 2826 AT amp T Paradyne may use or distribute any of the information supplied as appropriate without incurring any obligation whatsoever United States FCC Registration number AW292J 61661 DD N PSTN Ringer Equivalence number REN V 32 DBM option 0 7B V 34 DBM option 0 2B Canada V 32 Dial Backup Module Certification number 230 3684 A DOC Load number 7 V 34 Dial Backu
4. 8 bits per character 1 stop bit no parity February 1996 3610 A2 GB43 40 General COMSPHERE 3600 Series Technical Specifications Table 1 1 3 of 3 Technical Specifications Primary channel rates 64 56 38 4 19 2 9 6 4 8 and 2 4 kbps Async Sync rates 64 56 48 38 4 32 19 2 18 8 18 0 16 8 14 4 12 0 DATA RATES PHYSICAL DIMENSIONS 3610 DSU Height Width Depth 3611 DSU non modular or modular Height Width thickness Depth Rear Connector Plate 2 port Height Width Depth 25 Pin V 35 Interface 3000 Series Carrier Height Width Depth WEIGHT 3610 DSU 3610 DSU with DBM 3611 DSU modular 3611 DSU modular with DBM 3611 DSU non modular 3611 DSU non modular with DBM Rear Connector Plate 2 port 25 Pin EIA 232 25 Pin V 35 3000 Series Carrier 16 DSUs with DBMs plus SDU and fan module 3610 A2 GB43 40 9 6 9 2 7 2 4 8 4 4 2 4 2 0 and 1 2 kbps Other asynchronous rates e g 150 300 600 and 1800 bps can be obtained through oversampling Asynchronous rates support ITU CCITT V 14 extended rate range at 8 to 12 bits per character including the start and stop bit 2 3 2 5 percent overspeed underspeed compensation at 10 bits per character 2 13 inches 7 63 inches 12 13 inches 7 13 inches 0 90 inch 13 40 inches 5 24 inches 0 88 inch 1 00 inch 10 50 inches 19 00 inches 14 00 inches 3 70 pounds 4 10 pounds 1 86 kg 0 91 pound 0 41 kg
5. 1 5 V 34 DBM and DBM F Technical Specifications RINGER EQUIVALENCE NUMBER REN DBM option 0 2B APPROVALS DOC Certification PSTN 230 6811 A Load Number 3 APPLICATION Full or half duplex data transmission via analog 2 wire Dial Network PSTN point to point MODULATION AND FREQUENCY At 28 8 kbps ITU T V 34 At 12 and 14 4 kbps CCITT V 32bis 1800 Hz At 4 8 and 9 6 kbps CCITT V 32 1800 Hz At 2 4 kbps CCITT V 22bis 2400 Hz CHANNEL EQUALIZATION Transmitter Receiver Compromise equalizer Automatic adaptive equalizer COMMUNICATION LINE 2 wire analog PSTN line DATA RATES 2 4 4 8 7 2 9 6 12 14 4 16 8 19 2 21 6 24 26 4 and 28 8 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series V 32 or V 34 DBM only If Call Setup is set for Alarm or None then any V 32 or V 34 modem can be used Also V 22bis at 2 4 kbps can be used RECEIVE VF INTERFACE Dynamic Range V 34 2 wire PSTN 48 to 10 dBm Impedance 600 Q SWITCHED NETWORK INTERFACE 3610 DSU 6 pin modular jack Permissive USOC RJ11C 3611 DSU One or two 50 pin connector Permissive USOC RJ21X TRANSMIT VF INTERFACE Signal Level V 34 2 wire PSTN Permissive 9 dBm Impedance 600 Q 3610 A2 GB43 40 February 1996 1 7 COMSPHERE 3600 Data Service Units Table 1 6 2 Wire Switched 56 DBM and DBM D Technical Specifications APPROVALS DOC Certif
6. 6 port connector module that provides a total of six 25 pin D subminiature EIA 232 connections including the DSU In addition a 26 pin high density D type connector provides a V 35 interface through an adapter cable Provides five additional 25 pin D subminiature connectors that can be optioned for EIA 232 or V 35 for a total of six EIA 232 or six V 35 interfaces Provides one 60 pin high density D type connector that provides five additional EIA 232 interfaces through an adapter cable Digital bridging capability is fully supported by the COMSPHERE 6700 or 6800 Series NMS Release 4 0 or greater for the 6700 Series NMS and Release 4 1 5 or greater for the 6800 Series NMS software in ADp and DATAPHONE modes 1 TDM and MCMP circuit cards can be configured to provide digital bridge capability 3610 A2 GB43 40 February 1996 1 13 Model 3610 Installation Sl E Be tore Installation Process Installing the DSU Powenns Dpihe ORE id PowerUp Routine ids serere SERRE DDS Network Connection Dial Network Connection Switched 56 kbps Network Connection ISDN DBM Network Connection Overview The Model 3610 DSU 1 delivered with default hardware strap settings and factory installed software options The DSU is ready to connect to the network No on site assembly is requi
7. jacks Via the SDU in the COMSPHERE 3000 Series Carrier or DC OUT via NMS adapter cable for a tributary in the carrier 2 4 4 8 9 6 56 and 64 kbps 19 2 kbps loop at levels of 6 0 or 10 dBm All AT amp T Paradyne digital products and other products that are compliant with AT amp T Technical Reference 62310 1987 3600 Series enhanced 3600 diagnostics nondisruptive or disruptive 3500 Series 2600 diagnostics 2600 Series 2600 diagnostics 2500 Series 2500 loopbacks 1 a 3600 Series DSU is not used on both ends of the circuit or if the scrambler configuration option 64KScrambling is not enabled the customer s DTE must provide for the primary data s ones 1s density 1 4 February 1996 3610 A2 GB43 40 Technical Specifications Table 1 3 3600 Hubbing Device Technical Specifications APPLICATION Diagnostic interfaces for the Model 3610 DSU NETWORK MANAGEMENT INTERFACES NMS Two 8 pin modular jacks Note that the 3600 Hubbing Device has a 6 inch attached cable that terminates in a 4 pin modular plug PHYSICAL DIMENSIONS Height 1 9 inches 4 8 cm Width thickness 0 9 inches 2 3 cm Depth 3 4 inches 8 6 cm WEIGHT 0 13 pounds 0 06 kg 3610 A2 GB43 40 February 1996 1 5 COMSPHERE 3600 Data Service Units V 32 DBM Specifications RINGER EQUIVALENCE NUMBER REN APPROVALS DOC Certification PSTN Load Number APPLICATION MODULATION AND FREQUENCY CHANNEL EQU
8. with Article 800 of the National Electric Code NFPA 70 in the United States and Section 60 of the Canadian Electric Code Part 1 in Canada To connect the DSU to the DDS network L gt Procedure Plug the DDS network interface RJ48S cable into the DSU jack labeled LINE po For Canada plug the 6 pin cable end feature number 3600 F1 006 into the wall jack DDS Network Connection i lt 00 00 L C e s 485 Wall Jack ZZ 495 14578 02 If aremote DSU 15 also connected to the network the e DSU s green OK indicator lights Alrm indicator goes off e Health and Status screen no longer displays a No Signal message 3610 A2 GB43 40 Model 3610 Installation If connecting the DSU to a LADS network there are distance limitations that govern the use of DSUs on the network See Appendix F in the User s Guide for LADS connection distances Dial Network Connection If your DSU 1s equipped with a V 32 or V 34 DBM 7 Procedure Plug one end of the dial analog interface cable into the DSU jack labeled BACKUP p Plug the other end of the cable into the modular jack provided by the telephone company e USOC permissive for V 32 or V 34 e USOC RJ45S programmable for V 32 only gt If your site has programmable service verify that the DSU s hardware strap 51 1 is switched to the OFF position Dial Network a
9. 10 1987 Bell Canada DCTE Specifications Bell Communications Research Technical Reference Publication 41028 Bellcore Special Report SR NWT 001953 DATAPHONE II 2600 Series Data Service Units User s Manual EIA 232 D V 24 ISO 2110 Integrated Network Corporation Compatibility Bulletin CB INC 101 ITU TSS CCITT V 35 ISO 2593 Northern Telecom NIS S204 29 1986 Pacific Bell PUB L 780035 PB NB Pacific Bell PUB L 780036 PB NB Document Ordering To order AT amp T Paradyne documentation please call 1 800 545 2354 extension 2222 or 1 813 530 8777 To order AT amp T documentation please call 1 800 432 6600 or 1 317 322 6572 February 1996 COMSPHERE 3600 Data Service Units Product Related Documents The following table lists 3600 related documentation COMSPHERE 3600 Series Product Related Documentation Document Name COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 User s Guide COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Time Division Multiplexer Multichannel Multipoint and Digital Bridge Options Supplement COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Dial Backup Module Options Supplement COMSPHERE 3600 Series Data Service Units Models 3610 and 3611 Technical Reference Manual COMSPHERE 3600 DBM Option Installation Instructions COMSPHERE 3000 Series Carrier Installation Manual COMSPHERE 48 Vdc Central Office Power Unit Installation
10. 600 Series Table 1 1 e ISDN DBM and DBM I Table 1 8 DSU Table 1 2 e Table 1 9 3600 Hubbing Device Table 1 3 MCMP Table 1 10 V 32 DBM and DBM V Table 1 4 e Digital Bridge Table 1 11 Table 1 1 1 of 3 General COMSPHERE 3600 Series Technical Specifications AC POWER FUSE Model 3610 3611 DSU No accessible fuse 3000 Series Carrier 4 amp fuse AT amp T Paradyne part number 190 0037 0431 two spares supplied with carrier AC POWER REQUIREMENTS 3610 DSU 24 Vac 3610 DSU with DBM 24 Vac CT 60 Hz 0 093 amp 5 8 watts at 115 Vac CT 60 Hz 3611 DSU 24 Vac CT 60 Hz CT 60 Hz 60 H 0 114 amp 9 5 watts at 115 Vac 3 3 3 0 029 amp 4 5 watts at 115 Vac 3 0 080 amp 8 0 watts at 115 Vac 3 Z 0 024 amp 2 0 watts at 115 Vac 3000 Series Carrier 16 DSUs with DBMs 90 132 Vac 60 Hz 3 1 650 amp 165 watts at 115 Vac plus SDU and fan module 3611 DSU with DBM 24 Vac DBM V 32 or Switched 56 24 Vac CT 3610 A2 GB43 40 February 1996 1 1 COMSPHERE 3600 Data Service Units Table 1 1 2 of 3 General COMSPHERE 3600 Series Technical Specifications APPROVALS FCC Part 15 FCC Part 68 UL 3610 DSU 3611 DSU 3000 Series Carrier CSA Safety 3610 DSU 3611 DSU 3000 Series Carrier Emissions Bell Canada DTE INTERFACE 3610 and Non modular 3611 DSUs 25 pin D subminiature connector 34 pin connector Modular 3611 DSU 25 Pin V 35 Interface Uses a Rear Co
11. 996 3610 A2 GB43 40 Safety Instructions Government Requirements United States Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual Specific instructions are listed in the following sections Notice to Users of the Telephone Network 3610 A2 GB43 40 This equipment complies with Part 68 of the FCC rules On the bottom of the equipment is a label or silk screened text that contains among other information the FCC registration number and Ringer Equivalence Number REN for this equipment If requested please provide this information to your telephone company The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your number is called In most areas the sum of the RENS of all devices should not exceed 5 Call your local telephone company to ascertain the maximum REN for your calling area If your Model 3610 or 3611 DSU with DBM causes harm to the telephone network the telephone company may discontinue your service temporarily If possible they will notify you in advance But if advance notice is not practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in facilities equipment operations or procedures that could affect the proper operation of your
12. ALIZATION Transmitter Receiver COMMUNICATION LINE DATA RATES DBM COMPATIBILITY RECEIVE VF INTERFACE Dynamic Range V 32 2 wire PSTN Impedance SWITCHED NETWORK INTERFACE 3610 DSU 3611 DSU TRANSMIT VF INTERFACE Signal Level V 32 2 wire PSTN Impedance 1 non 3600 Series DBM V 32 modem Dial command 1 required to complete the 1 6 Table 1 4 and DBM V Technical Specifications DBM option 0 7B 230 3684 A 7 Full or half duplex data transmission analog 2 wire Dial Network PSTN point to point At 12 and 14 4 kbps CCITT V 32bis 1800 Hz At 4 8 and 9 6 kbps CCITT V 32 1800 Hz At 2 4 kbps CCITT V 22bis 2400 Hz Compromise equalizer Automatic adaptive equalizer 2 wire analog PSTN line 2 4 4 8 7 2 9 6 12 14 4 kbps If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series V 32 DBM only If Call Setup is set for Alarm or None then any V 32 or V 34 modem can be used Also V 22bis at 2 4 kbps can be used 43 to 10 dBm 600 Q 6 pin modular jack Permissive USOC RJ11C 8 pin modular jack Programmable USOC RJ45S One or two 50 pin connector Permissive USOC RJ21X Programmable USOC RJ27X Permissive 9 dBm Programmable 12 to 0 dBm 600 Q Ils into the DBM with firmware version 2 8 or lower a manual switch to the backup process February 1996 3610 A2 GB43 40 Technical Specifications Table
13. DBM S use proprietary rate adaption to support data rates of less than 56 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series Switched 56 DBM only If Call Setup is set for Alarm or None then any switched 56 kbps terminal interface unit TIU can be used SWITCHED 56 KBPS NETWORK INTERFACE 3610 DSU 8 pin modular jack USOC 5 56 3611 DSU One or two 50 pin connector USOC SJA57 NETWORK COMPATIBILITY AT amp T Technical References 41458 and 61330 3610 A2 GB43 40 February 1996 1 9 COMSPHERE 3600 Data Service Units Table 1 8 ISDN DBM and 1 Technical Specifications APPROVALS DOC Certification 230 6943 A APPLICATION Full duplex data transmission ISDN BRI U Interface for point to point or multipoint facilities MODULATION AND FREQUENCY 2B1Q line coding with 4 level pulse amplitude modulation PAM at 80 K baud CHANNEL EQUALIZATION Receiver Automatic adaptive equalizer with echo cancellation COMMUNICATION LINE 2 wire BRI ISDN line DATA RATES 56 and 64 kbps Note that ISDN DBM or DBM I use proprietary rate adaption to support data rates of less than 64 kbps DBM COMPATIBILITY Compatible with 3600 Series 2 wire and 4 wire Switched 56 DBMs RECEIVE INTERFACE Dynamic Range Operates on 2 wire loops as defined in ANSI T1 601 1992 Impedance 135 Q SWITCHED NETWORK INTERFACE 3610 DSU 8 pin non keyed modular jack USOC SJA11 U I
14. Guide COMSPHERE 3600 Series Data Services Units Models 3610 and 3611 Secondary Channel Applications Supplement COMSPHERE 6800 Series Network Management System Communications Products Support Command Reference Manual COMSPHERE 6700 Series Network Management System User s Guide Document Number 3610 A2 GB46 User s Guide Ships with all standalone 3610 DSUs Provides descriptions of features installation instructions front panel operation configuration options and worksheets troubleshooting messages and specifications 3610 A2 GB48 Supplement to the User s Guide Ships with all standalone 3610 DSUs with MCMP or Digital Bridge options or upgrades Provides descriptions of TDM MCMP and Digital Bridge features installation instructions front panel operation configuration options and worksheets troubleshooting messages and specifications 3610 A2 GB49 Supplement to the User s Guide Ships with all standalone 3610 DSUs with Dial Backup Modules or upgrades Provides descriptions of features installation instructions front panel operation configuration options and worksheets troubleshooting messages and specifications 3610 A2 GH30 Orderable Provides detailed information on the DSU DBM SNA Diagnostic Interface TDM MCMP and Digital Bridge features specifications configuration scenarios async terminal operation pin assignments NMS operations messages and
15. age points or other risks Refer all servicing to qualified service personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer 7 When installed in the final configuration the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products In addition if the equipment is to be used with telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface A Use caution when installing or modifying telephone lines Avoid usin
16. an equipment list 3610 A2 GZ52 Ships with field installable dial backup upgrades Contains installation procedures for all Model 3610 and 3611 DBM types Ships with every carrier Contains installation procedures for the carrier and its components options and operation 3000 A2 GA31 3000 A2 GB41 Ships with every 48 Vdc power unit Includes descriptions of features installation instructions troubleshooting specifications and an equipment list 3610 A2 GB42 Orderable Provides details on DSUs equipped with the Secondary Channel option Provides descriptions of features DSU operation configuration examples worksheets and an equipment list 6800 A2 GB31 Ships with software Provides descriptions of device commands for interaction between 6800 Series NMS and other product lines 6700 A2 GY31 Ships with software and is orderable Provides descriptions of NMS features installation instructions configuration setup display and Statistics options reports generation online help conventions and input forms February 1996 3610 A2 GB43 40 Technical Specifications Tesla os od chem chee ERI RS PR eed Pacte Ra E pu P Edere Ead ade 1 1 Technical Specifications V34 DBM and DBM F Table 1 5 Tables 1 1 through 1 11 list the technical specifications e 2 Wire Switched 56 DBM and DBM D Table 1 6 for the following 4 Wire Switched 56 DBM and DBM S Table 1 7 General COMSPHERE 3
17. e Powering Up the DSU CAUTION The power cord and ac transformer have a 3 wire grounding type plug with a grounding pin This is a safety feature Grounding of the unit is vital to ensure safe operation Do not defeat the purpose of the grounding plug by modifying it or by using an adapter Prior to installation use an outlet tester or voltmeter to check the ac receptacle for earth ground If the power source does not provide a ground connection consult an electrician to determine another method of grounding the unit before proceeding with the installation 2 2 February 1996 57 Procedure 1 Atthe rear of DSU insert the round end of the power cable into the receptacle labeled POWER Grounded AC 2 Wall Outlet LA Low a oleae AC Power W In 9j C Table Top 224 Ss Transformer X CA 495 14703 2 Connect the 3 prong plug at the other end of the cable to an ac outlet Power Up Routine When you apply power the DSU performs a power up routine and e Determines what hardware options are installed if any This may include DBM MUX TDM and MCMP e Automatically runs a Device Test on itself and each installed hardware option All front panel lights flash on and off 3610 A2 GB43 40 00 Network Connection NOTE Before connecting the DSU to the DDS network ensure that approved primary protectors have been installed on the circuit in accordance
18. e ringer Equipment Warranty and Support 3610 A2 GB43 40 AT amp T Paradyne s Customer Assistance Center is available 24 hours a day to help you place an installation request report a hardware or software problem or place a trouble report The center provides technical support and remote diagnosis of equipment problems Monday through Friday between the hours of 8 a m and 8 p m EST excluding holidays You can also call the center if you participate in the on site support program or if you would like to request support on a time and materials basis refer to the Enhanced Support Services section Call the following toll free number to reach the Customer Assistance Center 1 800 237 0016 or 1 813 531 4373 Examine the equipment carefully upon arrival If there is an obvious defect call the Quality Careline at 1 813 530 2273 or call 1 800 237 0016 press 0 zero for operator and ask for extension 2273 February 1996 F COMSPHERE 3600 Series Data Service Units Equipment Service Out of Warranty To obtain service under your warranty call the Customer Assistance Center at the number listed above Please have the following information available before you call Company Name and Address Contact Name and Telephone Number Shipping Address if different from the company address Billing Address if different than the shipping address Model Number and Serial Number of the unit Brief description of the problem The Customer Assista
19. e tributary devices 40 DSUs or 20 DSUs and DBMs LINE SPEEDS 56 kbps maximum usable data rate is 48 kbps CHANNEL SYNCHRONOUS RATES Primary DSU 1 2 2 4 4 8 7 2 9 6 12 0 14 4 16 8 19 2 38 4 and 48 kbps CHANNEL ASYNCHRONOUS RATES 150 300 600 1200 and 1800 bps plus all primary DSU rates PORT DTE INTERFACE 3610 DSU 2 port MCMP Flex Provides an additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater 3610 DSU 6 port MCMP Flex Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater 3611 DSU modular Provides a 6 port connector module that provides a total of six 25 pin D subminiature EIA 232 connections including the DSU in addition a 26 pin high density D type connector that provides a V 35 interface through an adapter cable for Port 1 3610 DSU MCMP DSD Provides five additional 25 pin D subminiature connectors that can be optioned for EIA 232 or V 35 for a total of six EIA 232 or six V 35 interfaces 3611 DSU non modular Provides one 60 pin high density D type connector that provides five additional EIA 232 interfaces through an adapter cable NMS SUPPORT MCMP capability is fully supported by the COMSPHERE 6700 or 6800 Series NMS Rel
20. ease 4 0 or greater for the 6700 Series NMS and Release 4 1 5 or greater for the 6800 Series NMS software in ADp and DATAPHONE 1 modes 1 Only MCMP circuit cards can be configured to provide MCMP capability 1 12 February 1996 3610 A2 GB43 40 Technical Specifications Table 1 11 Digital Bridge Technical Specifications APPLICATION Digital Bridge PORT SYNCHRONOUS RATES Primary DSU and Backup DBM DIAGNOSTIC SUPPORT PORT DTE INTERFACE 3610 DSU 2 port TDM Flex or MCMP Flex 3610 DSU 6 port TDM Flex or MCMP Flex 3611 DSU modular 3610 DSU TDM DSD or MCMP DSD 3611 DSU non modular NMS SUPPORT Provides 5 port digital bridging for various applications Used primarily for multipoint dial backup which can be configured as a central site bridge or an extended bridge 2 4 4 4 4 8 9 2 9 6 12 0 14 4 18 8 19 2 38 4 56 and 64 kbps Supports nondisruptive diagnostics NonD mixed and disruptive Disr diagnostic types The Disruptive Type configuration option must be set to either 3600e or Br56 Provides an additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides a
21. equipment If so you will be given advance notice so as to give you an opportunity to maintain uninterrupted service The DBM cannot be used on public coin operated telephone service provided by the telephone company Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information No repairs may be performed by the user Should you experience difficulty with this equipment refer to Equipment Warranty and Support February 1996 D COMSPHERE 3600 Series Data Service Units For Digital Data Service DDS installations inform the local telephone company of the appropriate facility interface code for the service you desire DDS Facility Interface Data Rate Code bps 04015 04015 040155 54905 64 The DDS Service Order Number is 6 0Y The jack configurations required are RJ48S for the Model 3610 DSU and RJ48T for the Model 3611 With the Model 3611 RJ48T configuration you must specify the number of data lines you require Refer to Chapter 1 Technical Specifications For DBM installations the proper service and jack must be ordered from the telephone company Refer to the following table for this information DBM Jack Installation Requirements DBM Type USOC Jack USOC Jack Canadian Jack Canadian Jack Standalone Carrier Mounted Standalone Carrier Mounted 12 0 or 14 4 kbps RJ11C Permissive RJ21X Permi
22. g a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone to report a gas leak in the vicinity of the leak February 1996 B COMSPHERE 3600 Series Data Service Units Notices WARNING THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE PURSUANT TO PART 15 OF THE FCC RULES THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE THE AUTHORITY TO OPERATE THIS EQUIPMENT IS CONDITIONED BY THE REQUIREMENTS THAT NO MODIFICATIONS WILL BE MADE TO THE EQUIPMENT UNLESS THE CHANGES OR MODIFICATIONS ARE EXPRESSLY APPROVED BY AT amp T PARADYNE WARNING TO USERS OF DIGITAL APPARATUS IN CANADA THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS CET APPAREIL NUM RIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU REGLEMENT SUR LE MATERIEL BROUILLEUR DU CANADA February 1
23. greater 3611 DSU modular Provides a 6 port connector module that provides a total of six 25 pin D subminiature EIA 232 connections including the DSU In addition a 26 pin high density D type connector provides a V 35 interface through an adapter cable 3610 DSU TDM DSD Provides five additional 25 pin D subminiature connectors that can be optioned for EIA 232 or V 35 for a total of six EIA 232 or six V 35 interfaces 3611 DSU non modular Provides one 60 pin high density D type connector that provides five additional EIA 232 interfaces through an adapter cable NMS SUPPORT TDM capability is fully supported by the COMSPHERE 6700 or 6800 Series NMS Release 4 0 or greater for the 6700 Series NMS and Release 4 1 5 or greater for the 6800 Series NMS software in ADp and DATAPHONES Il modes 1 and circuit cards can be configured to provide TDM capability 3610 A2 GB43 40 February 1996 1 11 COMSPHERE 3600 Data Service Units Table 1 10 MCMP Technical Specifications APPLICATION Multichannel multipoint Allows up to two or six independent application programs to share one standard multipoint digital facility depending upon the version 2 port or 6 port Digital sharing Allows up to three digital sharing groups two ports each at each tributary site or a maximum of six ports per group FEP port sharing Provides up to three separate FEP port sharing groups NUMBER OF TRIBUTARIES Supports up to 40 addressabl
24. hereof without obligation of AT amp T Paradyne Corporation to notify any person of such revision or changes A February 1996 3610 A2 GB43 40 Safety Instructions Important Safety Instructions 3610 A2 GB43 40 1 Readand follow all warning notices and instructions marked on the product or included in the manual 2 This product is intended to be used with a three wire grounding type plug a plug which has a grounding pin This is a safety feature Equipment grounding is vital to ensure safe operation Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter Prior to installation use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground If the receptacle is not properly grounded the installation must not continue until a qualified electrician has corrected the problem If a three wire grounding type power source is not available consult a qualified electrician to determine another method of grounding the equipment 3 Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect it from overheating these slots and openings must not be blocked or covered 4 Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord 5 Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous high volt
25. iated with single line individual service may be extended with a certified connector assembly telephone connection cord The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations If you experience difficulty with this equipment and require service refer to the Equipment Warranty and Support section Repairs to certified equipment should be made by an authorized Canadian maintenance facility Any repairs or alterations made by the user to this equipment or equipment malfunctions may cause the telecommunications company to ask you to disconnect the equipment Users should ensure that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together for protection This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or an electrician as appropriate The load number LN is labeled on the equipment The LN denotes the percentage of the total load to be connected to a telephone loop used by this equipment To prevent an overload the total of the LNs of all devices attached to the loop may not exceed 100 The LN also specifies the appropriate ringing type A or B if applicable For example LN 20A designates a load number of 20 and an A typ
26. ication Number 230 5870 Load Number 0 APPLICATION Full or half duplex data transmission via 56 kbps switched services compatible with AT amp T US SPRINT and MCI using DataPath 2 wire switched access to a local exchange carrier LEC or an interexchange carrier IEC COMMUNICATION LINE A dedicated 2 wire access or a local exchange carrier 2 wire switched access DATA RATES 56 kbps Note that 2 wire Switched 56 DBM or DBM D use proprietary rate adaption to support data rates of less than 56 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series Switched 56 DBM only If Call Setup is set for Alarm or None then any Switched 56 kbps terminal interface unit TIU can be used SWITCHED 56 KBPS NETWORK INTERFACE 3610 DSU 6 pin modular jack USOC SJA48 3611 DSU One or two 50 pin connector NETWORK COMPATIBILITY Northern Telecom NIS 5204 2 1986 1 8 February 1996 3610 A2 GB43 40 Technical Specifications Table 1 7 4 Wire Switched 56 DBM and DBM S Technical Specifications APPLICATION Full or half duplex data transmission via 56 kbps switched services compatible with AT amp T MCI and US SPRINT using 4 wire switched access to a local exchange carrier LEC or an inter exchange carrier IEC COMMUNICATION LINE A dedicated 4 wire access or a local exchange carrier 4 wire switched access DATA RATES 56 kbps Note that 4 wire Switched 56 DBM or
27. le into the modular jack provided for the ISDN network connection ISDN Network Connection U Interface Connector NI 495 14580 01 W Enter and save the following required fields e SPID number s SPID e Switch type Switch Typ seven digit telephone number s Phone Refer to the Configuration Branch section in Chapter 3 and Appendix C Ordering ISDN Service in the DBM Options Supplement for details 3610 A2 GB43 40
28. nce Center will verify that the equipment is in need of repair You are provided a Return Materials Authorization RMA number to help expedite the repair request The RMA number must be in a visible location on the outside of the package Once you receive an RMA number pack the unit securely Ship the package insured and postage prepaid to amp Paradyne Corporation Customer Support Attn Repair Center 8550 Ulmerton Road Building B Largo Florida 34641 If your equipment is out of warranty and you do not have a maintenance support agreement factory repair support is available To send equipment to AT amp T Paradyne s Repair Center call the following toll free number Monday through Friday between the hours of 8 a m and 5 p m EST excluding holidays 1 800 772 7691 or 1 813 530 2268 In Canada call 1 905 709 5000 Please have the information listed in the Equipment Service section ready when you call for your RMA number then package and ship the equipment to the Repair Center address Make sure the RMA number is visible on the outside of the package A Purchase Order can be mailed with the equipment or faxed to the Repair Center Enhanced Support Services In addition to the customer support described AT amp T Paradyne offers a wide variety of enhanced customer support programs that are designed to meet customers needs Our high quality support programs range from equipment installation to premium on site support as well a
29. nnector Plate with two 25 pin D subminiature connectors ENVIRONMENT Operating Temperature Storage Temperature Relative Humidity Shock and Vibration HEAT DISSIPATION MAX AT 115 VAC 3610 DSU 3610 DSU with DBM 3611 DSU 3611 DSU with DBM 3000 Series Carrier 16 DSUs with DBMs plus SDU and fan module NMS COMPATIBILITY ASYNC TERMINAL 1 2 Class A digital device AW292J 61661 DD N Listed UL 1950 Recognized Component UL 1950 Certified CSA 22 2 No 220 M1986 Certified Component CSA 22 2 No 950 M89 Class A digital apparatus DCTE Specifications July 1989 Issue 1 EIA 232 D ITU CCITT V 24 ISO 2110 ITU CCITT V 35 ISO 2593 EIA 232 D ITU CCITT V 24 ISO 2110 ITU CCITT V 35 ISO 2593 A modular DSU V 35 interconnect cable is required to use the V 35 connector The cable provides an interface between the DSU s 25 pin D type connector and the DTE cable s V 35 connector 32 to 122 F 0 to 50 C 4 to 158 F 20 to 70 C 5 95 noncondensing Withstands normal shipping and handling 22 16 Btu hr 29 00 Btu hr 22 16 Btu hr 27 30 Btu hr 563 00 Btu hr DATAPHONE II System Controller Diagnostic Console or Network Controller COMSPHERE 6700 Series NMS Release 4 0 or greater for full support COMSPHERE 6800 Series NMS Release 4 1 5 or greater for full support NetView Version 1 Release or greater ANSI X3 64 VT 100 compatibility Rate 9 6 kbps
30. nterface Connector 3611 DSU One or two 50 pin connector Permissive USOC RJ21X TRANSMIT INTERFACE Signal Level 13 5 dBm nominal over frequency band from 0 Hz to 80 kHz Impedance 135 0 1 10 February 1996 3610 A2 GB43 40 Technical Specifications Table 1 9 TDM Technical Specifications APPLICATION Multiplexing Provides time division multiplexing of up to two or six independent ports depending upon the version 2 port or 6 port Digital sharing Allows two groups of consecutive ports to share the same TDM channel FEP port sharing Provides up to three separate FEP port sharing groups Digital bridge Configured to perform a 5 port digital bridge capability PORT SYNCHRONOUS RATES 1 2 2 0 2 4 4 0 4 4 4 8 7 2 8 4 9 2 9 6 12 0 14 4 16 8 18 0 18 8 19 2 28 8 32 38 4 48 56 and 64 kbps PORT ASYNCHRONOUS RATES 150 300 600 1200 and 1800 bps plus all primary DSU rates Asynchronous rates support 42 3 2 5 percent overspeed underspeed compensation PORT DTE INTERFACE 3610 DSU 2 port TDM Flex Provides an additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater 3610 DSU 6 port TDM Flex Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or
31. p Module Certification number 230 6811 A DOC Load number 3 2 Wire Switched 56 DBM Certification number 230 5870 A DOC Load number 0 ISDN Dial Backup Module Certification number 230 6943 A DOC Load number 0 COMSPHERE is a registered trademark of AT amp T DataPath is a trademark of Northern Telecom Inc DATAPHONE is a registered trademark of AT amp T MCI is a registered trademark of MCI Communications Corporation NetView is a trademark of International Business Machines Corporation US SPRINT is a registered trademark of US SPRINT Communications Company COPYRIGHT 1996 AT amp T Paradyne Corporation rights reserved This publication is protected by federal copyright law No part of this publication may be copied or distributed transmitted transcribed stored in a retrieval system ortranslated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written permission of AT amp T Paradyne Corporation 8545 126th Avenue North Box 2826 Largo Florida 34649 2826 AT amp T Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose Further AT amp T Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents
32. red Before You Begin Before connecting any cables to your DSU verify the following e There is a dedicated grounded ac outlet within 6 feet that is protected by a circuit breaker Label the circuit breaker that protects the ac outlet and ensure that the circuit breaker is set to ON e Your installation site is clean well lit ventilated and free from environmental extremes e You have contacted the telephone company to coordinate installing your DSU to the DDS network The DSU can only operate at the data rate provided by the DDS network The DBM if enabled should also be connected to the dial network e Your package contains a power cord with table top ac transformer 3610 A2 GB43 40 495 14705 CAUTION Only use the power transformer designed for the Model 3610 DSU Using other transformers may result in personal injury or damage to the equipment Installation Process e Installing the DSU e Verifying the Hardware Strap Setting e Powering Up the DSU e DDS Network Connection February 1996 2 1 COMSPHERE 3600 Data Service Units Installing the DSU The Model 3610 DSU 1 designed for desktop operation e Place the DSU in the planned location Allow 1 to 2 feet of clearance for cable connections space for the ventilation slots on the sides and clearance at the rear for the cable connections NOTE Before powering up the DSU verify the hardware strap settings Refer to the User s Guid
33. s network management For more information about our enhanced support services contact your AT amp T Paradyne representative or call the following toll free number 8 a m to 5 p m EST excluding holidays 1 800 482 333 or 1 813 530 8623 February 1996 3610 A2 GB43 40 Preface Objective To better serve volume Model 3610 DSU customers AT amp T has provided this replacement documentation so that customers can order only the number of User s Guides or Supplements wanted while permitting us to fulfill our legal and regulatory requirements Document No 3610 A2 GB46 ships with every Model 3610 DSU Document No 3610 2 48 ships with every or Document No 3610 2 49 ships with every DBM Please refer to the COMSPHERE 3600 Series Data Service Units DSUs Models 3610 and 3611 User s Guide Document No 3610 A2 GB46 when operating the DSU Contents Chapter 1 lists the technical specifications for the DSU Dial Backup Modules DBMs Time Division Multiplexer TDM Multichannel Multipoint MCMP and the digital bridge options Chapter 2 describes electrical connection of the Model 3610 DSU as well as Digital Data Service DDS Switched 56 kbps dial and ISDN networks 3610 A2 GB43 40 Reference Documents ANSI X3 64 1979 Reaffirmed 1990 ANSI T 410 AT amp T Technical Reference 41458 AT amp T Technical Reference 61330 AT amp T Technical Reference 623
34. ssive CA11A Permissive CA21A Permissive V 32bis DBM RJ45C Programmable RJ27X Programmable CA27A Programmable CA27A Programmable V 34 DBM RJ11C Permissive RJ21X Permissive CA11A Permissive CA21A Permissive 2 Wire Switched SJA48 SJA48 uses an CA11 CA21A 56 DBM adapter cable metallic channel metallic channel 4 Wire Switched SJA56 SJA57 Not available Not available 56 DBM in Canada in Canada ISDN BRI DBM SJA11 SJA11 uses an 11 CA A11 uses an adapter cable adapter cable After the telephone company has installed the requested service and jack you can connect the DSU with the cable provided An FCC compliant telephone cord and modular plug are provided with this equipment This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68 compliant E February 1996 3610 A2 GB43 40 Canada Safety Instructions Notice to Users of the Canadian Telephone Network The Canadian Department of Communications has certified that this equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee that the equipment will operate to the user s satisfaction Before installation verify connectivity of this equipment to the local telecommunications company s facilities The equipment must be connected by an acceptable method In some cases the telecommunications company s inside wiring assoc