DK-AC-KNX-1 User Manual

image

Contents

1. 1 Enabled O Disabled E 13 Remote Control Enable 1bit 1 Enabled O Disablec CE 14 SavejExec Scene 1byte 0 Scenet 4 SceneS ud 15 Current Scene 1byte 0 Scenel 4 SceneS ER 16 Time Counter 2byte Hours O Intesis Software S L All rights reserved URL http www intesis com 4 28 This information is subject to change without notice n te S S amp Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng 2 Connection The interface comes with a cable 1 meter long for direct connection to the internal control board of the AC indoor unit Connection of the interface to the AC indoor unit Disconnect mains power from the AC unit Open the front cover of the indoor unit in order to have access to the internal control board In the control board locate the socket connector marked as S21 in Domestic line models Using the cable that comes with the interface insert its smaller connector into the socket of the DK AC KNX 1 marked as AC Unit and the other connector the biggest one into the socket S21 of the AC unit s control board Fix the DK AC KNX 1 inside or outside the AC indoor unit depending on your needs remember that DK AC KNX 1 must be also connected to the KNX bus Close the AC indoor unit s front cover again IMPORTANT Do not modify the length of the cable
2. Compressor motor grounded or short circuit inverter PCB fault Over current of all inputs Compressor over current compressor motor wire cut Stall prevention error start up error Compressor locked etc Power transistor error Communication error between inverter and outdoor control unit Shortage of refrigerant thermal storage unit Power voltage imbalance open phase Sensor error of temperature rise in a switch box Radiation fin temperature sensor error DC current sensor system error AC or DC output current sensor system error Total input current sensor error Capacity setting error outdoor Low pressure drop due to insufficient refrigerant or electronic expansion valve error etc Reverse phase Open phase Power voltage failure Instantaneous power failure Failure to carry out check operation transmission error Communication error between indoor unit and outdoor unit communication error between outdoor unit and BS unit Communication error between remote control and indoor unit Remote control board failure or setting error for remote control Communication error between indoor units Communication error between outdoor units Communication error between outdoor unit and ice thermal storage unit Com
3. Description Show Hide Humidifying Mode bit objects Data type Enum 8bits Yes No Name Show Scene Objects Description Show Hide objects for handling scenes Data type Enum 8bits Yes No p Intesis solam E All rights reserved URL http www intesis com is information is su bject to change without notice info intesis com 34 938047134 Intesispg Ema software 21 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng IntesisBox is a registered trademark of Intesis Software SL Intesispg Ema software info intesis com 34 938047134 Name Show Scene Bits Description Show Hide bit objects for handing scenes Data type Enum 8bits Yes No Name Show Auto Details Description Show Hide Auto bit objects Heat Cool Data type Enum 8bits Yes No Name Enable Mode Fan Swing Humi Texts Description Show Hide text type objects for Mode Fan Swing and Humidifying Mode Data type Enum 8bits Yes No Name Mode Auto Text Description Text description of Auto Mode to be shown in Mode Text communication object Data type String 14bytes Name Mode Heat Text Description Text description of Heat Mode to be shown in Mode Text communication object Data type String 14bytes Name Mode Dry Text Description Text description of Dry Mode to be shown in Mode Text
4. Indicates or activates Vertical Swing Access type Read Write Data type ID 1 001 Object 26 Name Swing Horizontal 1bit Function 1 Enable Vertical Swing Left Right O Disable Vertical Swing Description Indicates or activates Horizontal Swing Access type Read Write Data type ID 1 001 O Intesis Software S L All rights reserved URL http www intesis com 14 28 LJ This information is subject to change without notice n te S S amp Email info pintesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Objects for Selection of Humidifying Mode Only one among these five objects will be active in any moment If 1 is written in any of them all others will be forced to zero If AC unit changes its Fan Speed the corresponding object will be activated 1 while all others will be forced to zero If AC unit changes its Operation Mode Auto Heat Cool Humidifying Mode will be automatically set to Off Object 35 Name Humidifying Off 1bit Function 1 Humidifying Mode Off Description Indicates or activates this Humidifying Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 36 Name Humidifying Low 1bit Function 1 Humidifying Low Description Indicates or activate
5. Set to O for clearing its value after filter maintenance Access type Read Write Data type ID 7 001 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 8 28 IntesisBox KNX Daikin A C Domestic line Object 12 Name Set Temperature Virtual 2bytes Function 31 169C or 30 109C or 32 189C depending on operation mode see AC unit table below Description This object is used to set the temperature of the AC unit when the ambient temperature is also supplied from KNX i e from a KNX temperature sensor thermostat Value is used by DK AC KNX 1 only when Virtual Temperature Control parameter is active set to Yes See Virtual Ambient Temperature communication object and Virtual Temperature Control parameter Object s value is read from KNX bus on startup Access type Write only Data type ID 9 001 Object 13 Name Ambient Temperature Virtual 2bytes Function 10 389C Description This object is used to indicate to the AC unit the present ambient temperature measured by an external KNX sensor Value is used by DK AC KNX 1 only when Virtual Temperature Control parameter is active set to Yes See Virtual Set
6. Temperature communication object and Virtual Temperature Control parameter Object s value is read from KNX bus on startup Access type Write only Data type ID 9 001 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 9 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Ancillary Objects Object 29 Name Window 1bit Function 0 Open 1 Close Description Indicates to the AC unit the status of the room s window If opened after the minutes indicated in the parameter Minutes Window the AC unit will be switched off automatically The AC unit will remain OFF while the window is open If Minutes Window is O the AC unit will be switched off immediately Object s value is read from bus on startup Access type Write only Data type ID 1 009 Object 30 Name Device Enable 1bit Function O Disabled 1 Enabled Description This object indicates wheter the DK AC KNX 1 is enabled or disabled Value is stored in DK AC KNX 1 s eeprom If disabled the only active object of DK AC KNX 1 will be this one the rest of objects will not be operative To enable DK AC KNX 1 again set this object back to 1 Fa
7. communication object Data type String 14bytes Name Mode Fan Text Description Text description of Fan Mode to be shown in Mode Text communication object Data type String 14bytes Name Mode Cool Text Description Text description of Cool Mode to be shown in Mode Text communication object Data type String 14bytes Name Fan Auto Text Description Text description of Fan Speed Auto to be shown in Fan Text communication object Data type String 14bytes Name Fan Low Text Description Text description of Fan Speed Low to be shown in Fan Text communication object Data type String 14bytes Name Fan Mid 1 Text Description Text description of Fan Speed Mid 1 to be shown in Fan Text communication object Data type String 14bytes O Intesis Software S L All rights reserved URL http www intesis com his information is subject to change without notice 22 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng IntesisBox is a registered trademark of Intesis Software SL Name Fan Mid 2 Text Description Text description of Fan Speed Mid 2 to be shown in Fan Text communication object Data type String 14bytes Name Fan Mid 3 Text Description Text description of Fan Speed Mid 3 to be shown in Fan Text communication object Data type String 14
8. http www intesis com his information is subject to change without notice info intesis com 34 938047134 Intesispg Ema software 23 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Humidifying Text communication object Data type String 14bytes Name Humidifying Continuous Text Description Text description of Humidifying Mode Continuous to be shown in Humidifying Text communication object Data type String 14bytes O Intesis Software S L All rights reserved URL http www intesis com 24 28 This information is subject to change without notice n te S S amp Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng 6 Specifications Dimensions 59 X 36 X 21 mm Weight 429 KNX current consumption 5 mA Operating Temperature 25 859C Stock Temperature 40 859C Isolation voltage 4000 V 7 AC Unit Types compatibility A list of Daikin indoor unit model references compatible with DK AC KNX 1 and their available features can be found in http www intesis com pdf IntesisBox DK AC xxx 1 AC Compatibility pdf O Intesis Software S L All rights reserved URL http www intesis com 25 28 This information is subject to change without notice n tes S amp Email
9. info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng 8 Error Codes Error in Remote Error category Controller Error Code KNX Object Indoor Unit Outdoor Unit O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL software Error Description External protection devices activated Indoor unit PCB assembly failure Interlock error for fan Drain level system error Temperature of heat exchanger 1 error Temperature of heat exchanger 2 error Fan motor locked overload over current Swing flap motor error Overcurrent of AC input Electronic expansion valve drive error Heater overheat Dust collector error No maintenance filter error Capacity setting error indoor Shortage of water supply Malfunctions of a humidifier system water leaking Malfunctions in a sensor system Sensor system of drain water error Heat exchanger 1 Liquid pipe thermistor system error Heat exchanger 1 Gas pipe thermistor system error Sensor sy
10. to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 18 28 IntesisBox KNX Daikin A C Domestic line Bit objects showing Auto Mode User s manual r8 eng N de Objeto 46 Nombre Auto Heat 1bit Funci n 1 AC Unit is in Heat Mode Descripci n Indicates this Operation Mode with a value of 1 Tipo de acceso Read only ID tipo de dato 1 002 N de Objeto 47 Nombre Auto Cool 1bit Funci n 1 AC Unit is in Cool Mode Descripci n Indicates this Operation Mode with a value of 1 Tipo de acceso Read only ID tipo de dato 1 002 O Intesis Software S L All rights reserved URL This information is subject to change without notice n te S S amp Email IntesisBox is a registered trademark of Intesis Software SL sofware tel http www intesis com info intesis com 34 938047134 19 28 IntesisBox KNX Daikin A C Domestic line 5 Parameters Name AC Unit type Description Indicates the type of AC indoor unit Select the model of your AC indoor unit from the list of models available Factory value is type CONVENTIONAL Main features for each AC unit type will be shown in a textbox below this parameter Data type Enum 8bits CONVENTIONAL Name Window minu
11. 047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng INDEX 1 di I nejBet c PMETUMT 4 2 CONNECTION iii L 5 3 Configuration and setup societe eer serere x rexit mer ERE ERO X TRE RF ERR RETEREIEER E Iu aa 5 4 KNX communication objects A COGATUR TR GR PR HER I 6 5 Parameters Em 20 6 SPeCCITICAH ONS mM 25 7 AC Unit TY Pes COMPAL DINE 4 castor ieee eit eel eek ra xe rota te dee OR 25 8 Error COLES iue dowd civab lois vi ATR E RA EEE VERE ciate UDINE rre 26 O Intesis Software S L All rights reserved URL http www intesis com 3 28 This information is subject to change without notice n te S S amp Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng 1 Presentation DK AC KNX 1 allows a complete and natural integration of Daikin air conditioners with KNX control systems Compatible with all models of Domestic line of air conditioners Main features e Reduced dimensions Installation even inside the A C indoor unit e Quick and non visible installation e External power not required e Direct connection to the KNX EIB bus e Direct connection to the AC indoor unit e Fully KNX interoperable configuration from ETS e Multiple objects for control of differ
12. 1 increases in one degree When the parameter Set Temperature Switching Object Type is set to DPT Step e With every write of 0 the temperature setpoint increases in one degree e Writing 1 decreases in one degree When the maximum or minimum setpoint temperature is reached it stops increasing or decreasing Value is meant to be written only when Virtual Temperature Control parameter is inactive set to No Access type Write only Data type ID 1 007 1 008 O Intesis Software S L All rights reserved URL http www intesis com LJ This information is subject to change without notice n te S S amp Email info pintesis com tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 software 16 28 IntesisBox KNX Daikin A C Domestic line Bit Object for storing scenes Object 42 Name Save Scenel ibit Function 1 Save Scene 1 Description Setting this object to 1 forces DK AC KNX 1 to store in eeprom memory the current set values of Operation Mode Setpoint Temperature Fan Speed Swing Mode and Humidifying Mode for scene 1 Access type Write only Data type ID 1 002 Object 43 Name Save Scene2 1bit Function 1 Save Scene 2 Description Setting this object to 1 forces DK AC KNX 1 to store in eeprom memory the current set values of Operation Mode Setpoint Temperature Fan Speed Swing Mode an
13. 14 Name Fan 1byte Function O Aut 1 Low 2 Md1 3 Md2 4 Md3 5 High Description This object is used to monitor the Fan speed in the AC unit Access type Read Write Data type ID 5 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 6 28 IntesisBox KNX Daikin A C Domestic line Object 15 Name Fan Text 14 bytes Function 14 characters maximum Description _ This object is a text description of the selected Fan speed Access type Read only Data type ID 16 001 Object 23 Name Swing 1byte Function O 0ff 1 Vertical Swing 2 Horizontal Swing 3 Both Description Swing working mode in the AC unit Access type Read Write Data type ID 5 Object 24 Name Swing Text 14 bytes Function 14 characters maximum Description This object is a text description of the selected Swing mode Access type Read only Data type ID 16 001 Object 33 Name Humidifying Mode 2bytes Function 0 Off 1 2 Low 2 Standard 3 High 4 Continuous Description Working mode of AC unit s Humidifier URURU SARARA model only Access type Read Write Data type ID 5 Object 34 Name Hu
14. Note that a value of 0 indicates no error condition 555 indicates communication error between DK AC KNX 1 and the AC Unit Consult further error codes in the list below Access type Read only Data type ID 7 Object 40 Name Save Execute Scene 1byte Function For Storing 128 Scenel 129 Scene2 For Executing 0 Scene1 1 Scene2 Description This object is used for storing executing a scene a scene is a given combination of set values for Operation Mode Setpoint Temperature Fan Speed Swing Mode and Humidifying Mode in the AC unit The actual combination of these values is stored in DK AC KNX 1 s eeprom when storing and retrieved from memory and set in the AC unit when executing Access type Write only Data type ID 18 001 Object 41 Name Current Scene 1byte Function O Scenel 1 Scene2 Description This object is used to monitor the active scene a scene is a given combination of set values for Operation Mode Setpoint Temperature Fan Speed Swing Mode Humidifying Mode in the AC unit Access type Read only Data type ID 17 001 Object 32 Name Time Counter 2byte Function 0 65535 hours Description This object indicates the AC indoor unit s operation time in hours Value is stored in DK AC KNX 1 s eeprom This value can be used for maintenance control of AC indoor unit s filter as well as for monitoring AC unit s operation time
15. S amp Email info pintesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134
16. abled the communication objects Set Temperature Virtual and Ambient Temperature Virtual are used to provide the setpoint and ambient temperatures respectively from KNX When enabled the following formula applies for calculation of real Set Temperature sent to the AC unit Set Temperature A C Set Temperature Virtual Ambient Temperature Virtual Set Temperature Virtual 2 When enabled Set Temperature A C object is meant not to be written is only for information purposes to know in each moment the real setpoint sent to the air conditioner When disabled Set Temperature Virtual and Ambient Temperature Virtual objects are not present Data type Enum 8bits Yes No O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 20 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng IntesisBox is a registered trademark of Intesis Software SL Name Operating Mode Byte Object Type Description e When Enumeration is selected Mode object is shown and DPTHvacContrMode object is hidden e When DPT HvacControlling is sele
17. ame Fan Low 1bit Function 1 Fan Low Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 Object 19 Name Fan Mid1 1bit Function 1 Fan Middlel Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 Object 20 Name Fan Mid2 1bit Function 1 Fan Middle2 Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 Object 21 Name Fan Mid3 1bit Function 1 Fan Middle3 Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 Object 22 Name Fan High 1bit Function 1 Fan High Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 O Intesis Software S L All rights reserved This information is subject to change without notice URL http www intesis com 13 28 ntes IS E a info intesis com IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Objects for selecting Swing Mode If AC unit s mode allows doing so both objects can be active at the same time Object 25 Name Swing Vertical 1bit Function 1 Enable Vertical Swing Up Down 0 Disable Vertical Swing Description
18. ases the speed in one step When the parameter Fanspeed Switching Object Type is set to DPT UpDown e With every write of 0 the fan speed increases in one step e Writing 1 decreases the speed in one step If speed is incremented when the maximum is reached it changes to automatic If speed is incremented when the maximum is reached it changes to low speed The operation in opposite direction is analogous Access type Write only Data type ID 1 007 1 008 O Intesis Software S L All rights reserved URL http www intesis com LJ This information is subject to change without notice n te S S amp Email info pintesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 12 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Objects for Selection of Fan Speed Only one among these six objects will be active in any moment If 1 is written in any of them all others will be forced to zero If AC unit changes its Fan Speed the corresponding object will be activated 1 while all others will be forced to zero Object 17 Name Fan Auto 1bit Function 1 Fan in Auto Description Indicates or activates this Fan speed with a value of 1 Access type Read Write Data type ID 1 002 Object 18 N
19. bytes Name Fan High Text Description Text description of Fan Speed High to be shown in Fan Text communication object Data type String 14bytes Name Swing Off Text Description Text description of Swing mode Off to be shown in Swing Text communication object Data type String 14bytes Name Swing Vertical Text Description Text description of Swing mode Vertical to be shown in Swing Text communication object Data type String 14bytes Name Swing Horizontal Text Description Text description of Swing mode Horizontal to be shown in Swing Text communication object Data type String 14bytes Name Swing Both Text Description Text description of Swing mode Both to be shown in Swing Text communication object Data type String 14bytes Name Humidifying Off Text Description Text description of Humidifying Mode Off to be shown in Humidifying Text communication object Data type String 14bytes Name Humidifying Low Text Description Text description of Humidifying Mode Low to be shown in Humidifying Text communication object Data type String 14bytes Name Humidifying Standard Text Description Text description of Humidifying Mode Standard to be shown in Humidifying Text communication object Data type String 14bytes Name Humidifying High Text Description Text description of Humidifying Mode High to be shown in O Intesis Software S L All rights reserved URL
20. cted DPTHvacContrMode object is shown and Mode object is hidden e When Both is selected both Mode and DPTHvacContrMode objects are shown Data type Enum 8bits Enumeration DPT HvacControlling Both Name Fanspeed Switching Object Type Description Selects data type for Fan Speed object e When DPT Step is selected Fan Speed object works in Step logic O2 Decrease 1 Increase e When DPT UpDown is selected Fan Speed object works in Up Down logic O Up 1 Down Data type Enum 8bits DPT Step DPT UpDown Name Set Temperature Switching Object Type Description Selects data type for Set Temperature object e When DPT Step is selected Set Temperature object works in Step logic O Decrease 1 Increase e When DPT UpDown is selected Set Temperature object works in Up Down logic 0 Up 1 Down Data type Enum 8bits DPT Step DPT UpDown Name Show Device Objects Description Show Hide bit objects for Window Device Enable and Remote Control Enable Data type Enum 8bits Yes No Name Show Mode Bits Description Show Hide Mode bit objects Data type Enum 8bits Yes No Name Show Fan Bits Description Show Hide Fan Speed bit objects Data type Enum 8bits Yes No Name Show Swing Bits Description Show Hide Swing Mode bit objects Data type Enum 8bits Yes No Name Show Humidifying Objects Description Show Hide Swing Mode objects Data type Enum 8bits Yes No Name Show Humidifying Bits
21. ctory value for this object is 1 Enabled Access type Read Write Data type ID 1 003 Object 31 Name Remote Control Enable 1bit Function 0 2 Disabled 1 Enabled Description This object is used to disable enable the AC indoor unit s remote control Value is stored in DK AC KNX 1 s eeprom If enabled the AC unit can be controlled simultaneously by both AC unit s remote control and KNX Factory value for this object is 1 Enabled Access type Read Write Data type ID 1 003 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 10 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Objects for selection of Operation Mode Only one among these five objects will be active in any moment If 1 is written in any of them all others will be forced to zero If the AC unit changes its Operation Mode the corresponding object will be activated 1 while all others will be forced to zero Object 5 Name Mode Auto 1bit Function 1 Mode Auto Active Description Indicates or activates this Operation Mode with a value of 1 Access typ
22. d Humidifying Mode for scene 2 Access type Write only Data type ID 1 002 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL URL Intesispg Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 17 28 IntesisBox KNX Daikin A C Domestic line Bit Objects for executing scenes Object 44 Name Execute Scenel 1bit Function 1 Execute scene 1 Description Setting this object to 1 forces DK AC KNX 1 to retrieve from eeprom the values for scene 1 setting up its Operation Mode Setpoint Temperature Fan Speed Swing Mode and Humidifying Mode in the AC unit accordingly These values should have been saved previously using object Save Scenel Access type Write only Data type ID 1 002 Object 46 Name Execute Scene2 1bit Function 1 Execute scene 2 Description Setting this object to 1 forces DK AC KNX 1 to retrieve from eeprom the values for scene 2 setting up its Operation Mode Setpoint Temperature Fan Speed Swing Mode and Humidifying Mode in the AC unit accordingly These values should have been saved previously using object Save Scene2 Access type Write only Data type ID 1 002 O Intesis Software S L All rights reserved This information is subject
23. e Read Write Data type ID 1 002 Object 6 Name Mode Heat 1bit Function 1 Mode Heat Active Description Indicates or activates this Operation Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 7 Name Mode Dry 1bit Function 1 Mode Dry Active Description Indicates or activates this Operation Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 8 Name Mode Cool 1bit Function 1 Mode Cool Active Description Indicates or activates this Operation Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 9 Name Mode Fan 1bit Function 1 Mode Ventilation Active Description Indicates or activates this Operation Mode with a value of 1 Access type Read Write Data type ID 1 002 O Intesis Software S L All rights reserved This information is subject to change without notice URL http www intesis com 11 28 ntes IS E a info intesis com IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Object for Increasing Decreasing Fan Speed Object 16 Name Fanspeed 1bit Function O Decrease 1 Increase 0 Up 1 Down Description When the parameter Fanspeed Switching Object Type is set to DPT Step e With every write of 0 the fan speed decreases in one step e Writing 1 incre
24. ent types bit byte characters e Control of the AC unit based in the ambient temperature read by the own AC unit or in the ambient temperature read by any KNX thermostat e Total Control and Monitoring of the AC unit from KNX including monitoring of AC unit s state of internal variables running hours counter for filter maintenance control and error indication and error code e AC unit can be controlled simultaneously by the IR remote control of the AC unit and by KNX e Up to 2 scenes can be saved and executed from KNX fixing the desired combination of Operation Mode Set Temperature Fan Speed and Swing in any moment by using a simple Switching type object ETS3 Topology in ME AC KNX 1 V2 El File Edit View Commissioning Diagnostics Extras Window Help DS x 2 7 ARAMAN E EE 1 New Area o H 1 1 New Line edm im Interface ER 0 On Off 1bit 1 0n 0 0ff ad 1 Made 1byte O Aut 1 Heat 2 Dry 3 Fan 4 Coo a 2 Mode Text 14byte Maximum 14 characters ER 3 Fan 1byte 0 Aut 1 Low 2 Md1 3 Md2 4 High ER 4 Fan Text 14byte Maximum 14 characters EE 5 Vane 1byte O Aut 1 Hor 5 Ver 6 Swing E 6 Vane Text 14byte Maximum 14 characters CE 7 Set Temperature 2byte C ud 8 Ambient Temperature 2byte 10 38 C ad 9 Error 1bit 1 Error in AC Unit aa 10 Error Code 2byte AC Unit Error Code ER 11 Window 1bit 1 Closed O Window Open CE 12 Device Enable 1bit
25. er error Heat exchanger of hot water error O Intesis Software S L All rights reserved URL http www intesis com 27 28 This information is subject to change without notice n te S S Email info intesis com IntesisBox is a registered trademark of Intesis Software SL software tel 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Outdoor air humidity sensor error Supply air temperature sensor error Return air temperature sensor error Outdoor air temperature sensor error Remote controller temperature sensor error Water leakage sensor 1 error Water leakage sensor 2 error Dew condensation error Centralized remote controller PCB error Communication error between centralized remote control devices Centralized remote control devices inappropriate combination Centralized remote controller address setting error Error in the communication of DK AC KNX 1 device with the AC unit In case you detect an error code not listed contact your nearest Daikin technical support service fro more information on the error meaning O Intesis Software S L All rights reserved URL http www intesis com 28 28 This information is subject to change without notice n tes
26. midifying Text 14bytes Function 14 characters maximum Description This object is a text description of the selected Humidifying mode Access type Read only Data type ID 16 001 Object 10 Name Set Temperature A C 2bytes Function 31 169C or 30 109C or 32 18 C depending on operation mode see AC unit table below Description This object controls the temperature setpoint of the AC unit Value is meant to be used to set the temperature of the AC unit only when Virtual Temperature Control parameter is inactive set to No always can be read and reflects the current setpoint in the AC unit Access type Read Write Data type ID 9 001 Object 27 Name Error 1bit Function O No Error 1 Operation Error Description This object when set to 1 indicates either an error in the AC unit or communication failure between AC unit and DK AC KNX 1 Access type Read only Data type ID 1 005 IntesisBox is a registered trademark of Intesis Software SL O Intesis Software S L All rights reserved his information is subject to change without notice URL Intesis gt Ema software http www intesis com info intesis com 34 938047134 User s manual r8 eng 7 28 IntesisBox KNX Daikin A C Domestic line Object 28 Name Error Code 2bytes Function AC Unit Error Code Description This object indicates the Error Code of the AC unit
27. munication error between main and sub remote controllers sub remote control error Combination error of other indoor unit remote control in the same system model Communication error between other indoor unit and outdoor unit in the same system Communication error between other BS unit and indoor outdoor unit Combination error of indoor BS outdoor unit model quantity etc setting error of spare parts PCB when replaced Improper connection of transmission wiring between outdoor and outdoor unit outside control adaptor Centralized address duplicated Attached equipment transmission error Communication error between indoor unit and centralized control device Failure to carrey out check operation Indoor outdoor outdoor outdoor communication error etc All system error PC board error Ozone density abnormal Contamination sensor error Indoor air thermistor system error Outdoor air thermistor system error HVU error Ventiair dust collecting unit Dumper system error Door switch error Replace the humidity element Replace the high efficiency filter Replace the deodorization catalyst Simplified remote controller error Fan motor of supply air over current or overload Fan motor of return air over current Fan motor of return air overload Inverter system error supply air side Inverter system error return air side Humidifying valve error Chilled water valve error Hot water valve error Heat exchanger of chilled wat
28. r8 eng 4 KNX communication objects Main Objects Object 0 Name On Off 1bit Function 1 On 0 Off Description This object is used to Start On and Stop Off the AC unit Access type Read Write Data type ID 1 001 Object 1 Name Mode 1byte Function O Aut 1 Heat 2 Dry 3 Fan 4 Cool Description This object is used to monitor the Operation Mode in the AC unit Access type Read Write Data type ID 5 Object 2 Name DPTHvacContrMode 1byte Function O Aut 1 Heat 3 Cool 9 Fan 14 Dry Description This object is used to monitor the Operation Mode in the AC unit Access type Read Write Data type ID 20 105 Object 3 Name DPT Heat Cool 1bit Function 02 Cool 1 Heat Description This object is used to monitor the Operation Mode in the AC unit Writing a O sets the Operation Mode to Cool Writing 1 sets the Operation Mode to Heat Setting the Operation Mode to Heat through Mode object or DPTHvacContrMode object sets this object to 1 Setting the Operation Mode to any other but Heat sets this object to 0 Access type Read Write Data type ID 1 100 Object 4 Name Mode Text 14 bytes Function 14 characters maximum Description _ This object is a text description of the selected Operation Mode Access type Read only Data type ID 16 001 Object
29. s this Humidifying Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 37 Name Humidifying Standard 1bit Function 1 Humidifying Standard Description Indicates or activates this Humidifying Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 38 Name Humidifying High 1bit Function 1 Humidifying High Description Indicates or activates this Humidifying Mode with a value of 1 Access type Read Write Data type ID 1 002 Object 39 Name Humidifying Continuous 1bit Function 1 Humidifying Continuous Description Indicates or activates this Humidifying Mode with a value of 1 Access type Read Write Data type ID 1 002 O Intesis Software S L All rights reserved This information is subject to change without notice IntesisBox is a registered trademark of Intesis Software SL software ntes IS E a info intesis com 34 938047134 URL http www intesis com 15 28 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Bit Object for changing Setpoint Temperature Object 11 Name Set Temperature 1bit Function O Decrease 1 Increase 0 Up 1 Down Description When the parameter Set Temperature Switching Object Type is set to DPT Step e With every write of 0 the temperature setpoint decreases in one degree e Writing
30. sIntesisBox KNX DK AC KNX 1 v0 4 Interface for integration of Daikin air conditioners into KNX TP 1 EIB control systems Compatible with Domestic line air conditioners commercialised by Daikin Application s Program Version 0 4 User s Manual Pam K N X r8 eng Order Code DK AC KNX 1 Issue Date 2011 09 09 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Intesis Software S L All Rights Reserved Information in this document is subject to change without notice The software described in this document is furnished under a license agreement or nondisclosure agreement The software may be used only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Intesis Software S L Intesis Software S L Mil Fontanals 1 bis 12 08700 Igualada Spain TRADEMARKS All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders O Intesis Software S L All rights reserved URL http www intesis com 2 28 m This information is subject to change without notice n te S S amp Email info pintesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938
31. stem error of fan motor locked overload Sensor system of swing flag motor error Sensor system of over current of AC input Suction air thermistor error Discharge air thermistor system error Contamination sensor error Humidity sensor error Remote control thermistor error Radiation sensor error High pressure switch sensor Protection devices activated Outdoor uni9t PCB assembly failure High pressure switch HPS activated Low pressure switch LPS activated Overload of inverter compressor motor Over current of STD compressor motor Overload of fan motor Over current of fan motor Over current of AC input Electronic expansion valve drive error Four way valve error Pump motor over current Water temperature abnormal Site installed Protection device activated Malfunctions in a drain water Ice thermal storage unit error Malfunctions in a sensor system Air temperature thermistor error Sensor system of power supply error High Pressure switch is faulty Low pressure switch is faulty Compressor motor overload sensor is abnormal Compressor motor over current sensor is abnormal Overload or over current sensor of fan motor is abnormal Sensor system of over current of AC input Outdoor air thermistor system error Discharge air thermistor system error Pump motor sensor system of over curren
32. supplied with the interface it may affect to the correct operation of the interface Connection of the interface to the KNX bus Disconnect power of the KNX bus Connect the interface to the KNX TP 1 EIB bus using the KNX standard connector red grey of the interface respect polarity Reconnect power of the KNX bus Connections diagram i i AC indoor unit 1000 mm r i 5 Connection cable supplied with the interface SISO MMM 58 mm woo XN Xogsiseju gt gt I 1 I 1 Internal control board 1 1 1 1 KNX TP 1 EIB bus 3 Configuration and setup This is a fully compatible KNX device which must be configured and setup using standard KNX tool ETS ETS project for this device can be donwloaded from http www intesis com down eib DK AC KNX 1 zip Please consult the README txt file located inside the downloaded zip file to find instructions on how to install the database IMPORTANT Do not forget to select the correct model of AC indoor unit connected to the interface this is in Parameters of the device in ETS O Intesis Software S L All rights reserved URL http www intesis com 5 28 This information is subject to change without notice n te S S amp Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL software 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual
33. t is abnormal Water temperature sensor system error Sensor system of drain water is abnormal Ice thermal storage unit error alarm No 1 and No 2 common protection device operates No 1 protection device operates No 2 protection device operates Discharge pipe temperature is abnormal Temperature of heat exchanger 1 abnormal Discharge pressure abnormal Oil temperature is abnormally high Suction pressure abnormal Oil pressure abnormal Oil level abnormal URL http www intesis com 26 28 ntes IS E M info intesis com 34 938047134 IntesisBox KNX Daikin A C Domestic line User s manual r8 eng Sensor system error of refrigerant temperature Pressure sensor error Current sensor error Discharge pipe thermistor system error Low pressure equivalent saturated temperature sensor system error Suction pipe thermistor system error Heat exchanger 1 thermistor system error Heat exchanger 2 thermistor system error Oil equalizer pipe or liquid pipe thermistor system error Double tube heat exchanger outlet or gas pipe thermistor system error Discharge pipe pressure sensor error Oil temperature sensor error Suction pipe pressure sensor error Oil pressure sensor error Oil level sensor error Inverter system error Temperature rise in a switch box Radiation fin power transistor temperature is too high Compressor motor grounded or short circuit inverter PCB fault
34. tes Description Minutes to wait before switching the AC unit OFF after receiving the indication of window open If O the AC unit will be switched off immediately While in OFF and with window open if it receives an order to switch ON the timer will be initialised and the AC unit will be switched OFF after the configured minutes 0 30 minutes Factory value is 0 Data type Unsigned 8bits 0 30 Name Send object values to KNX on startup Description Indicates if DK AC KNX 1 will send to KNX the object values indicating AC Unit status at power up when KNX bus is plugged to DK AC KNX 1 Objects indicating AC Unit status are Mode Fan Speed Swing Mode Humidifying Mode and Set Temperature Data type Enum 8bits Yes No Name When window closes go to last state Description Defines behaviour of AC unit once window is closed after AC unit has been switched OFF as a result of an open window timeout e If this parameter is set to Yes last value that was written from KNX to object On Off will be sent to the AC unit e If it is set to No the AC unit will be left in OFF state until a new ON request is received from KNX Data type Enum 8bits Yes No Name Virtual Temperature Control Description Meant to be enabled when you want the temperature provided by a KNX sensor to be the reference ambient temperature for the air conditioner When en