Home

English - Dlog DNC Systems

image

Contents

1. the touch screen for 2 sec o Dii Customize the WLAN status display e In the DLoG Config program go to the WLAN menu e Open the WLAN status window which contains information about signal strengths and the quality of the WLAN connection e Customize the appearance of the WLAN status window e Save your settings TIP You can use the Parameter Connect Program to start any program automatically as soon as there is an active WLAN connection Program the keys on the front of the DLoG MPC 6 e In the DLoG Config program go to the Front Panel menu e Assign frequently used functions to the soft keys e Start external programs using the soft keys e Two functions can be assigned to those soft keys displayed white gray in the menu use lt Shift gt to switch between functions e Save your settings DLoG DAN 885901E 00 Quick Start Guide DLoG MPC 6 Wireless networks preparation on the desktop Depending on the ordered configuration the DLoG MPC 6 contains either a Summit WLAN card or a Proxim WLAN card Generally the WLAN profile is set as default in the factory by DLoG for the integrated card If any adjust ments are required tools for modifying the WLAN profile are available NOTE WLAN settings may be made only by qualified technical staff EJ Summit Client Utility Program SCU D a for DLoG MPC 6 with Summit WLAN card SUMMIT DATA COMMUNICATIONS e Start the Summit Client Utility program e Log on with
2. Quick Start Guide DLoG MPC 6 Configure the device on the desktop vehicles Software configuration for the WLAN function for Automatic switch off etc is significantly simpler and more convenient on the WE desktop i TIP Configure the DLoG MPC 6 before fastening it to machines or Prerequisites e Power supply cable e DLoG pre converter to connect the DLoG MPC 6 to an AC power supply e IMPORTANT The output voltage of the pre converter must be compatible with the input voltage of the DLoG MPC 6 If it is not the DLoG MPC 6 may become badly damaged Connection to power supply e If you want to operate the DLoG MPC 6 using an external mouse keyboard connect this before switching on the DLoG MPC 6 e Next connect the DLoG MPC 6 to the power supply Switch on the device e Press the lt Power gt button for 3 seconds to start the DLoG MPC 6 e If the DLoG MPC 6 has an automatic switch off function and this has already been configured the device will start as soon as the power supply is applied Log on as an administrator The settings for the automatic switch off function WLAN etc can be made only by administrators since the relevant tools are available in Admin mode ONLY To log on as an administrator e When the initial blue Windows start screen appears press and hold down the right lt Shift gt key on the keyboard e Name admin e Password gold Software settings preparation on the desktop You can use
3. eyond the vehicle Cable cover and strain relief on vehicle fork lift Once the DLoG MPC 6 and mounting bracket have been secured e Prepare the strain relief e Position the cables on the stress relief rail so that they will fit through the openings in the cable cover e Mount the cables loosely on the strain relief rail e When attaching the cables observe the following The power supply cable is provided with a ferrite core you must lay this cable in a loop for space reasons see photo below Final steps e Fix the cables to the strain relief rail e Close the cable cover carefully observing the assembly instructions provided with the DLoG MPC 6 Example for cable positioning Hotline If you have any further questions please contact your DLoG service partner or DLoG GmbH info dlog com Industriestra e 15 www dlog com D 82110 Germering Phone 49 89 41 11 91 999 DLoG DAN 885901E 00
4. rt circuit This will inevitably lead to malfunctions or even a total system failure Ground bolt Ignition O Q S 3 E 2 5 AT _ Further information User manual and device driver available from the DLoG download center The DLoG MPC 6 user manual and the latest device drivers are available from the DLoG download section on www dlog com DownloadCenter Additional technical details are available for registered users Copyright 2010 DLoG GmbH Industriestra e 15 D 82110 Germering All rights reserved MWe DIOS Competence in Mobile Computing Mechanical installation on vehicle fork lift Position of the DLoG MPC 6 on the vehicle The driver s field of vision in the vehicle must not be obstructed If you want to install a Keyboard and scanner on the side of the DLoG MPC 6 please allow enough space Overview of the installation steps Before you mount the DLoG MPC 6 onto the vehicle e The automatic switch off function must be configured e The forklift must be prepared connection to ignition observe correct voltage etc We recommend that the installation process is carried out in the following sequence e Step 1 Secure the mounting bracket onto the vehicle e Step 2 Attach the DLoG MPC 6 to the mounting bracket When installing your DLoG MPC 6 please observe the assembly instructions that come with the relevant mounting kit The DLoG MPC 6 and accessories must not protrude b
5. the DLoG Config program to configure automatic switch off the WLAN status display and the front keys on the DLoG MPC 6 Start DLoG Config e To start DLoG Config choose the program icon on the desktop e Or go to Start Programs e The default password is gold I Automatic Switchoff Configure the automatic switch off function Optional for DLoG MPC 6 devices on vehicles only e In the DLoG Config program go to the Automatic Switchoff menu e Configure the switch on and switch off behavior of the DLoG MPC 6 in connection with the vehicle ignition e Save your settings CAUTION If an incorrectly configured DLoG MPC 6 is connected to a given vehicle s ignition this can cause malfunctions to the extent El that the DLoG MPC 6 can possibly no longer be switched on or off Operate the touch screen using Fingers gloves touch screen pens Do not operate the touch screen using Sharp tools ball pens etc Open the context menu ONN eT DIOS Competence in Mobile Computing mo PRECONVERTER mi POWER Easy configuring the DLoG MPC 6 on the Desktop O Q PCI Slot RJ45 USB1 O aa a G ea ieee 107100 MBit Connectors on the DLoG MPC 6 for power supply accessories Ignition Tips for operating the DLoG MPC 6 Brightness Display brighter darker Background lighting on off i MPCG 8 08 ponu BEEBEBRBEBEBEBERBEES right click Press
6. the password SUMMIT all uppercase e Make the desired settings As an alternative to the SCU program you can also use the Windows Zero Configuration WZC program e Start the WZC program by choosing Desktop Admin Tools Control Panel Network Connections Wireless Network Connections Properties e Make the desired settings Proxim Atheros Client Utility Program pro gt lt im for DLoG MPC 6 with Proxim WLAN card wireless e Start the Atheros Client Utility program e Make the desired settings TIP Use the help function for this programs to read details about the setting options E Electrical installation on vehicle fork lift On the MPC 6 and on the vehicle e Ensure that the ground connection is correct e Choose a suitable position on the forklift for the ground connection e Sometimes the position from which the ground signal is to come is specified by the vehicle manufacturer e Position and attach the DLoG MPC 6 as close to the battery as possible e Do not attach the DLoG MPC 6 directly to a connector for a high powered consumer e g an inverter for fork lift motors as this could lead to restarts malfunctions or damage to the device Some forklifts have a chassis that is connected to DC Therefore the DLoG MPC 6 chassis is also connected to DC However if you use peripheral devices that supply DC to the DLoG MPC 6 via an interconnector such as a DC serial port this will cause a sho

Download Pdf Manuals

image

Related Search

Related Contents

Instructor`s Guide - Seidenberg School of Computer Science and  LSO-MMN-ESO-60400-00..    Scarica il catalogo ICT  BP-1 Battery Pack Installation Guide  Anleitung EVB Slim Receiver Variation io  aceites  TP-Link TL-ANT2409A Declaration of Conformity  Teac A-H300mkII Stereo Amplifier User Manual    

Copyright © All rights reserved.
Failed to retrieve file