Home
Version 1.0
Contents
1. Personality Display Default values SHADED m ic ola Pan reverse cern DEF j L N On Tilt reverse CEC JFF 17 Movement resolution I Lh BR Kea OFF amp On after switch 7 T Gn he fixture On rou OFF Switch On Off ZZ On the lamp light sensor LIN DFE Display On HN Gn pay oun DEF Display intensity o ink 229068 8 08 E Display reverse turn ma On PAN TILT feedback E a FEE a i ame On Lamp Off via DMX dl gi I Auto Low fan speed HIGH operating FAR 5 reo Lo r Loni 21 Adjusting the default positions of colour gobo and effect wheels By this function you can calibrate and adjust the colour and gobo wheels to their standard right positions Use the Up and Down keys to browse through the adjusting menu the display shows step by step these messages PAn Tilt SPEd Col1 Col2 PriS SGob rGob Grot IriS Foc Stro dimr FCAL by which you can adjust the fixture to the required desired position 0 255 before the function calibration Then when the positioning is finished use the last FCAL function Fixture calibration 0 255 0 255 8 055 08 255 8 255 0 255 8255 0 255 0 255 0 255 0 255 08 255 8 255 O255 0255 0 255 8055 0 255 1 Calibration via the control board Press Enter and the Up and Down keys in order to display the following messages Col1 Col2 SGob rGob Grot for very smooth function calibration Select one of them press Enter and use the Up and Down keys in ord
2. 15 DMX 512 Address settings The letter A flashes Use the Up and down keys to select required address 001 497 and press Enter to confirm or Mode to cancel and return to the main menu Pan reverse This function allows you to invert the pan movement Use the Up and Down keys to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Mode to cancel and return to the main menu Tilt reverse This function allows you to invert the tilt movement Use the Up and Down keys to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Mode to cancel and return to the main menu Movement resolution By this function you can adjust the desired movement resolution 8 or 16 bit Use the Up and Down keys to select On if you wish the 16 bit high resolution or Off if you wish only 8 bit resolution and press Enter to confirm or Mode to cancel and return to the main menu Note If you adjust the 16 bit resolution the fixture will occupy 16 DMX channels if you adjust the 8 bit resolution the fixture will be operated by only 14 DMX channels Please check the DMX protocol Lamp On time This option enables you to read the total number of hours that the lamp has been powered On Press Enter or Mode to return to the main menu In order to reset the counter to 0 you have to hold the Up and Down bu
3. FAn The message informs you that the fixture was overheating and the lamp was switched off This message will appear on the display if the fan speed operating LOOF is selected MbEr This messsage informs you that the main PCB does not communicate correctly with the Control Board CIEr color wheel 1 error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sen sor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The color wheel is not located in the default position after the reset C2Er color wheel 2 error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sen sor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The color wheel is not located in the default position after the reset rGEr rotating gobo wheel error This message will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The rotating gobo wheel is not located in the default position after the reset IGEr rotating gobo indexing error This message will appear after the reset of the fixture and if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its dr
4. Rear panel 5 Power switch 6 DMX output 7 DMX input 8 9 Power cord Fuse holder Front panel 10 Mode button 11 Enter button 12 Up button 8888 13 Down button O 8888 S 14 Display OOCO FR Ji Ji Gy se a 10 11 12 13 4 Installation 4 1Fitting the lamp DANGER Install the lamps with the device switched off only Unplug from mains before To insert the lamp OSRAM HSR 575 2 95V 575W GX 9 5 or PHILIPS MSR 575 2 95V 575W GX 9 5 MSD 575 95V 575W GX 9 5 loosen the lamp cover at the rear of head see the drawings by remowing the 3 fastening screws which are marked X Y Z Carefully pull out the cover with the lamp socket assembly If changing the lamp remove the old lamp from the socket Insert the lamp to the socket Do not install a lamp with a higher wattage A lamp like this generates temperatures the device is not de signed for Damages caused by non observance are not subject to warranty Please follow the lamp manufacturer s notes Do not touch the glass bulb with bare hands during the installation Make
5. The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature t 40 C must never be exceeded Otherwise the lamp is switched off and the fixture is out of operation for 5 minutes Allow the fixture to cool for at least 15 minutes before replacing the lamp CAUTION The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation CAUTION The lamp has to be replaced when it is damaged or deformed due to the heat Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock burns due to ultraviolet radiation lamp explosion crash etc 3 Description of the device 1 Moving head 2 Yoke 3 Carrying handles 4 Base
6. fot a G PAni Et SPdi Coif CoO HOLE SG O rbol brol rit Foci GPEn OPERA PAn tit SPd Coli Coe Pr O 5G I rbot ro Irie Foce Stri dni PAnJ kit GSPdAF SPd4 Coif Cog Pr 6 SOIG Got Gro9 diri FocS 6kr9 dint SPdS Loir La Lamp On automatically This menu allows you to turn the lamp On after switching the fixture On and switch On Off the lamp light sensor Lamp On after switching the fixture On This function enables to turn the lamp On automatically after switching the fixture On Use the Up and Down keys to select On if you wish to turn the lamp On automatically after switching the fixture On or Off if you wish the lamp Off after switching On the fixture and press Enter to confirm or Mode to cancel and return to the menu Switch On Off the lamp light sensor Use the Up and Down keys to select On if you wish to switch the lamp light sensor On and press Enter to confirm or Mode to cancel and return to the menu The option On is for the standard operation Use the Up and Down keys to select Off if you wish to switch the lamp light sensor Off and press Enter to confirm or Mode to cancel and return to the menu Important The option Off is for emergency operation only if the lamp light sensor is defective and you will wait for a delivery of the spare light sensor If the lamp light sensor was switched Off the error messages LAEr SnEr HEAt will not appear on the display only the message HEAt wil
7. Auto HIGH reG LoOF LoHI Press Enter if you wish to select one of them or Mode to cancel and return to the menu high max speed of fans The cooling fans work on max speed max cooling continuous controlling of the fan speed the fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can repeat several times until the temperature inside is on suitable level 20 low speed Switch Off the lamp operating the fan keeps the adjusted low speed until the temperature exceeds max inside temperature of the fixture then the ServoSpot 575 automatically switch Off the lamp low high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max inside temperature of the fixture then the ServoSpot 575 automatically switch from low to high the fan speed Oo l 614 C continuous controlling of the fan speed without the DMX value This mode is similar to reG but the initial level of fan speed can t be adjusted by the DMX Default settings Press Enter to reset all fixture personalities not the adjusting functions to the default values On the display will appear rSt meaning that the fixture makes the reset See the table of personality setting and their default positions
8. auromealed liqht system SERVOSPOT 5 5 USER MANUAL CD I Copyright SERVOSPOT 5 5 OMS lion Stistem Table of contents 1 Safely INSIrUCIIONS iscsi ceitcscicnecciwewnssnnticadewadinadanniuenduaweuenseanenaddausiasdanadedunausauincnncenuneciweudnn 3 2 Operating determinations ssi ies inci scans en canette een 4 3 Description OF the device sssssusssmnsenesssnnencenninnnsanncanagnnecanenntsnnnnssesenssannsnnnanensanness 5 A AS LANAI 0 DR Re 6 4 1Fitting the lamp ose RER detec eiekaeueebauaboeeee 6 4 2 Lamp adjustment ts Ann nan ane ont en an aa de eue 7 4 3 Inserting Exchanging rotating gobos ccceeeeeeeeeeeeeeeneeeeeeeeeeeeeaeeeeeeeeeeeeeeeneneeeees 7 4 4 Rigging the fixture PER tec detested ateaietie ata ccaawalldebadaliawiedia vel wolatiet cen tueedebodebenallneal 8 4 5 Connection to the mains ss 9 4 6 DMX 512 connection connection between fixtures ccccceeeeeeeeceeeeeeeeeeeeeeeeneeeeeees 9 D DMX PROTOCOL wicsisssscicciisssvinnnavinsvatenncsinenavdsevanensenaavannnensnabantensntsbueunnsnievoubaseaaseessnaaeebartics 10 6 AddressinNg nd Ge ti Gil tiens nl is 13 7 Remotely controllable functions ccsssssssmcninsnnsnnnnrmennanaansanensancenansansenssneananns 13 Pal WAND DAE A A E un Les 13 7 2 Switching On and Off the lamp by the control board 13 73 GOlour Wheels ironman a A a eeausasy cic sectiay 13 T4 Statie GONO WNEI ccinn 0 13 7 5 Rotating gobo wheel seo ei tect pi
9. image If you cannot detect the hot spot adjust the lamp until the light is evenly distributed 4 3 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched off only Unplug from mains before If you wish to use other forms and patterns as the standard gobos or if gobos are to be exchanged open the top cover of the head by loosening 2 screws on the top cover Remove the fixation ring with an appropriate tool Remove the gobo and insert the new gobo Press the fixation ring together and insert it in the front of the gobo CAUTION Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened 4 4 Rigging the fixture Danger of fire When installing the device make sure there is no highly inflammable material decoration articles etc in between a distance of min 0 5 m Warning Use 2 clamps to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed properly Ensure that the structure truss to which you are attaching the fixtures is secure The ServoSpot 575 can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics see the drawing The fixture s base enables to be mounted in two ways Use the clamps with screws M12 Fix a mounting plate and an eye bolt a part of delivery on the underside of the base see the dra
10. lubrication in six month intervals The quantity of oil must not be excessive in order to avoid that oil runs out when the gobo wheel rotates Replacing the fuse If the lamp burns out the fine wire fuse of the device might fuse too Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel with a fitting screwdriver from the housing anti clockwise 2 Remove the old fuse from the fuseholder 3 Install the new fuse in the fuseholder 4 Replace the fuseholder in the housing and fix it 12 Appendix We believe you will enjoy your ServoSpot 575 We assure you will enjoy this product for years if you follow the instructions given in this manual If you have any questions and comments please do not hesitate to contact us Please note errors and omissions for every information given in this manual excepted Every information is subject to change without prior notice Any claim due to missing or wrong information in this manual is herewith excluded 27
11. ne nn ne HN ce te nuit 14 7 6 3 facet r t ting PUN IN ett sn ed 14 PT MINS RS a ce eels de aie inlets 14 7 8 Foc s mu ltistep AO nai ee 14 7 9 Dimmer Shutter Strobe LS RUN eter ANNE unit 14 LAO FaN aca en ca PR D eae ENER ENEKEN EK tee eee 14 8 Control Board sein nana en ae anne aa a lies semaine 14 8 1 Main functions RS RAR Re 14 8 2 SPEC Special NOTONS ere eee eme teen 16 9 Error and information messages ss nnnreneennes 22 AG Technical SPECICATION ns tsar nnianna semi inta aies 23 11 Maintenance and cleaning is sssscccssssnnnrenrastinensasennnnecasannnssnnenn anensennnnausetenianann 25 12s PD PG 9101 ES een RER Re 25 CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this device have to be qualilfied follow the instructions of this manual Caution Be careful with your operations With a voltage of 230V you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Important The manufacturer will not accept liability for any re
12. order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using the standard controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture 10 5 DMX PROTOCOL hannel Channel Value Type of control 16 bit 8 bit Fanmoiemen sn 0 255 Pan movement Fanmoiemen sn 530 proportional Pan fine 0 255 Fine control of pan movement proportional Tilt 0 255 Tilt movement by 280 a Tilt fine 0 255 Fine control of tilt movement proportional Speed of PAN TILT movement Max speed tracking mode step From max speed to min speed vector mode proportional Max speed track mode black out while color or step gobo changes Ma
13. sure that the lamp is installed tightly into the lampholder system Reclose the lamp cover and tighten the 3 screws Before striking the lamp reset the LAti counter in the main menu of the Control Board by pressing the Up and Down buttons in one time and then confirming with the Enter button Adjust the lamp position by turning the screw A B C see Lamp adjustment below Lamp assembly Lamp cover Remove the screws X Y and Z for re lamping WARNING Disconnect the fixture from AC power before re lamping Lamp is hot Risk of fire Protect hands and eyes Wait at least 15min before opening the covers Adjust lamp position by turning screws A B and C 3 phillips screws X Y Z Do not operate this fixture with opened housing cover 4 2 Lamp adjustment Remove the screws X Y and Z for re lamping WARNING Disconnect the fixture from AC power before refamping 3 adjustment screws A B C The ServoSpot 575 lampholder is aligned at the factory Due to differences between lamps fine adjustment may improve light performance Strike the lamp open the shutter and the iris set the dimmer intensity onto 100 and focus the light on a flat surface wall Center a hot spot the brightest part of the image by using the 3 adjustment screws A B C Turn one screw after another a quarter turn clokwise counter clokwise to set the hot spot in the center of the
14. Rotating gobo wheel The rotating gobo wheel includes 3 metal gobos 1 glass gobo and 2 dichroic gobos rotating in both directions indexable rotating gobo wheel continuousli rotation from slow to fast The rotating gobos can be interchanged 7 6 3 facet rotating prism The 3 facet prism rotating in both directions at different soeeds 16 prism gobo macros 7 7 Iris Motorized adjustable iris variable pulse effects 7 8 Focus multistep zoom Motorized focus enables the beam to be focused anywhere on stage at different beam angles 15 18 22 provided by the special multistep zoom 7 9 Dimmer Shutter Strobe Smooth 0 100 dimming is provided by the combined mechanical dimmer shutter unit This unit may also be used for strobe effect 1 10 flashes per second 7 10 Fan The ServoSpot 575 is cooled by three axial fans two in the projector head and one in the base The speed of the fan and of course the noise can be continuously reduced if very quiet performance is required By the Control Board using the FAnS function you can choose 5 types of low fan speed operating 1 HIGH high max speed of fans The cooling fans work on max speed max cooling 2 rEG continuous controlling of the fan speed the fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can r
15. ameter m Beam angle 22 6270 1570 700 390 LUX 4 _ 3 E2 D E1 5 o g E1 2 3 4 0 5 10 15 20 Distance m 0 1 94 3 89 5 83 7 77 Diameter m 24 Colours Colour wheel 1 9 dichroic colour filters plus white colour wheel with variable rotation speed in both directions Colour wheel 2 6 dichroic colour filters colour temperature filters 3200 K and 5600 K UV filter plus white Static gobos 9 static metal gobos plus an open position static gobo wheel cont rotation Rotating gobos 6 interchanged gobos plus an open position 3 metal gobos 1 glass gobo and 2 dichroic gobos rotating in both directions at different speeds Gobo indexing Rotating gobo wheel cont rotation Outside diameter 27 mm image diameter 23 mm Strobe Strobe effect with variable speed 1 10 flashes per second Dimmer Smooth dimmer from 0 100 Prism 3 facet prism rotating in both directions at different speeds Focus Remotely controllable via DMX Motorized multi step zoom with three different apertures 15 18 22 Iris Motorized steplessly adjustable iris for different beam diameters Effects 16 prism gobo macros 9 static shacking gobos with variable speed preprogrammed variable iris pulse effects Motors 16 high quality stepping motors controlled by microprocessors Electronics Addressing special functions setting effects calibration via control panel with 4 digit LED disp
16. detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to flash A001 with actually set address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the device the controller is switched off or defective if the cable or connector is defective or the signal wires are swap in the input connector Note It s necessary to insert the XLR termination plug with 120 Ohm in the last lighting in the link in order to ensure proper transmission on the DMX data link 7 Remotely controllable functions 7 1 Lamp The ServoSpot 575 is run with a PHILIPS MSD 575 MSR 575 2 or OSRAM HSR 575 2 lamp A relay inside of the ServoSpot 575 allows you to switch On and Off the lamp via itself control board on the front panel of base or via your controller without affecting the rest of the lighting 7 2 Switching On and Off the lamp by the control board 1 Switch On the ServoSpot 575 and wait until the fixture reset has finished 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up and Down keys until the display shows LAMP Confirm by pressing Enter key 3 Use the Up and Down keys to select On for switch On the lamp and Off for switch Off the lamp and press Enter to confirm or Mode to cancel Note It is also important to note that the discharge lamp is cold re
17. ding handles 467mm Width of yoke 449 mm Height head horizontal 582 mm Weight net 33 kg Shipping weight 38 kg 280 460 AE iz a fe le 9 3 v zy Al 0000000000 0000000000 iz 26 11 Maintenance and cleaning It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used DANGER Disconnect from the mains before starting any maintenance work The objective lens will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The gobos may be cleaned with a soft brush The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet The dichroic colour filters the gobo wheel and the internal lenses should be cleaned monthly To ensure a proper function of the gobo wheel we recommend
18. ep Macro 15 step Macro 16 step Static gobos Open hole Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Shaking gobos with variable speed Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 224 255 Gobo wheel rotation from slow to fast proportional Rotating gobos Open hole Rot gobo 1 metal step Rot gobo 2 metal step Rot gobo 3 metal step Rot gobo 4 dichroic step Rot gobo 5 dichroic step Rot gobo 6 glass step Rot gobo wheel cont rotation from slow to fast proportional hannel Channel Value Type of control 16 bit 8 bit Rotating gobo index rotating gobo rotation 0 127 Gobo indexing proportional 128 190 Forwards gobo rotation from fast to slow proportional 191 192 No rotation step 193 255 Backwards gobo rotation from slow to fast proportional Iris 0 Open step 1 179 Max diameter to min diameter proportional 180 191 Closed step 192 223 Pulse closing from slow to fast proportional 224 255 Pulse opening from fast to slow proportional Focus multistep zoom Zoom 15 Continuous adjustment from far to near proportional Zoom 18 Continuous adjustment from far to near proportional Zoom 22 Continuous adjustment from far to near proportional Shutter strobe Shutter closed step No function Shutter open step Strobe effect from slow to fast max 10 flashes s proportional No function Shutter open step Pulse effect in sequences from slow to fast proportional No funct
19. epeat several times until the temperature inside is on suitable level 3 LoOF low speed Switch Off the lamp operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp Then the ServoSpot 575 automatically switch Off the lamp 4 LoHI low high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp of the fixture then the ServoSpot 575 automatically switch from low to high the fan speed 5 Auto continuous controlling of the fan speed without the DMX value This mode is similar to reG but the initial level of the fan speed can t be adjusted by the DMX 8 Control Board The control board situated on the front panel of the ServoSpot 575 offers several features You can simply set the lighting address read the number of lamp or unit hours switch On and Off the lamp run test show make a reset and also use special functions for manual demo and service purposes 8 1 Main functions The main menu is accessed by pressing the Mode key press this one so many times until the display shows message A001 with actually stored address Browse through the menu by the pressing Up and Down keys the display shows step by step these messages A001 rPAn rTilt 16br Lati Poti LAMP dEMo rESE SPEC Press Enter if you wish to select one of them The functions are described in the following sections and the function hierarchy is shown below
20. er to adjust their right value from 0 to 255 Then press Enter to confirm or Mode to cancel and return to the menu This can be repeated for each calibration parameter if it is required When the calibration is finished itis necessary to use the ArES function in order to write the calibration values to the memory EPROM and to make a reset in order to check the newly adjusted positions of the colour and gobo wheels When the reset of the fixture is finished the display will show the FCAL message Press Enter to repeat the calibration or Mode to return to the AdJ menu 2 Calibration via the external controller Press Enter and the Up and Down keys in order to display the following messages Col1 Col2 SGob rGob Grot calibration parameters Select one of them and press Enter Now you can calibrate the colour 1 colour 2 static gobo and rotating gobo wheels by your controller The DMX calibration protocol is described in the table ps cours 2 Colour 2 4 Rotating gobo 5 Gobo rotating DMX Calibration protocol 3 Calibration 0 255 Calibration 0 255 Calibration 0 255 Calibration 0 255 3 D 3 D lt O 3 D D O O Calibration 0 25 7 Standard protocol Colours 1 Standard protocol Standard protocol Standard protocol Standard protocol Standard protocol Standard protocol Standard protocol 22 OOo Static gobos Standard protocol 10 11 12 13 14 15 16 After having cal
21. ibrated required functions press Enter to confirm or Mode to cancel and return to the menu without reset by the ArES function and use the ArES function in order to write the calibration values to the memory EEPROM and to make a reset in order to check the new adjusted positions of the colour 1 colour 2 static gobo and rot gobo wheel and gobo indexing 9 Error and information messages HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched it off the lamp is too hot The message will appear on the display if the lamp doesn t ignite within 28 seconds The ServoSpot 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired Caution The message is disabled if the lamp light sensor function EnSn is switched Off only if the lamp was turned Off and On within 5 minutes the message HEAt will appear LAEr The ignition of the lamp is seven times unsuccessful the HEAt message appeared six times before and the display shows LAEr meaning that the lamp could be damaged or even missed the fixture is overheating this can occur if the ambient temperature is 40 C or more or there could be a failure on the ignitor or ballast Please place or replace the lamp check the ambient temperature or contact your dealer if the situation was not caused by the lamp Caution The message is disabled if the lamp light sensor function EnSn is switched Off
22. ion Shutter open step Random strobe effect from slow to fast proportional No function Shutter open step Dimmer intensity Gradual adjustment of the dimmer intensity proportional from 0 to 100 6 Addressing The control board on the front panel of the ServoSpot 575 allows you to assign the DMX fixture address which is defined as the first channel from which the ServoSpot 575 will respond to the controller If you set for example the address to channel 5 the ServoSpot 575 will use the channel 5 to 20 for control Please be sure that you don t have any overlapping channels in order to control each ServoSpot 575 correctly and independently from any other fixture on the DMX data link If two three or more ServoSpot 575 are addressed similarly they will work similarly For address setting follow this procedure 1 Switch On the ServoSpot 575 and wait until the fixture reset has finished rSt is flashing at the display 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up and Down keys until the display shows A001 Confirm by pressing Enter key and the letter A will flash 3 Use the Up and Down keys to select the desired address 4 Confirm by pressing Enter or Mode to cancel Controlling After having addressed all ServoSpot 575 you may now start operating these via your lighting controller Note After switching on the ServoSpot 575 will automatically
23. iver circuit on the main PCB The rotating gobo is not located in the default position after the reset SGEr static gobo wheel error This message will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The static gobo wheel is not located in the default position after the reset PrEr prism error This message will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The prism wheel is not located in the default position after the reset FtEr The message informs you that the fixture was overheating occured if the ambient temperature is 40 C or more and that the relay switched off the lamp This message will appear on the display until the temperature will be on a suitable level then the display will show the HEAt message meaning the lamp is too hot 23 SnEr This message appears if the lamp lighting sensor is failed Please contact your dealer Caution The message is disabled if the lamp light sensor function EnSn is switched Off PoEr This message will appear if the fixture was shortly disconnect from the main PAEr PAN yoke movement error This message will appear after the reset of the fixture if the yoke s magnetic indexing circuits malfunc
24. l appear if the lamp was turned Off and On within 5 minutes and at switching On of the lamp the electronics will still try to ignite the lamp until it shines even when the lamp is damaged or absent on this account some electronics parts could be damaged DMX values Readout DMX values of each channel received by the fixture Use the Up and Down keys to select desired channel and press Enter to read its value coming to the fixture or Mode to cancel and return to the menu 0 255 0055 0 255 0 255 255 0 255 O55 0 255 0 255 0255 0 255 0255 8 255 This function allows you to adjust the display settings id Int Display intensity By this function you can adjust from 20 to 100 the display intensity Use the Up and Down keys to select the level of the display intensity and press Enter to confirm or Mode to cancel and return to the menu Display reverse With this function you can rotate the display by 180 Use the Up and Down keys to select normal display or display turned by 180 and press Enter to confirm or Mode to cancel and return to the menu a Lin Display On This function allows you to keep the display On or to turn Off automatically 2 minutes after last pressing any key on the control board Use the Up and Down keys to select On if you wish to keep the display On or Off if you wish to turn Off automatically 2 minutes after last pressing any key on the control board and press E
25. lacement use lamps and fuses of the same type and rating only CAUTION EYEDAMAGES Avoid looking directly into the light source meant especially for epileptics 2 Operating determinations This device is a moving head spot for creating decorative effects and was designed for indoor use only If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Never run the device without lamp Do not shake the device Avoid brute force when installing or operating the device Never lift the fixture by holding it at the projector head as the mechanics may be damaged Always hold the fixture at the transport handles When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The minimum distance between light output and the illuminated surface must be more than 1 meter Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct eye bolt only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened
26. lay Readout fixture and lamp usage receiving DMX values temperature etc Built in analyzer for easy fault finding error messages Remotely switching of the lamp Bilt in demo sequences Black out while head moving or gobo color changing Silent fans cooling remotely controllable speed of fans Self resetable thermo fuse Digital serial input DMX 512 16 control channels full 16 bit protocol Channel 1 Horizontal head movement 8 bit Channel 2 Fine Horizontal head movement 16 bit Channel 3 Vertical head movement 8 bit Channel 4 Fine Vertical head movement 16 bit Channel 5 Pan Tilt speed Channel 6 Fan speed On Off lamp reset Channel 7 Colours 1 Channel 8 Colours 2 Channel 9 Prism rotation control Prism Gobo macros Channel 10 Static gobos 25 Channel 11 Rotating gobos Channel 12 Gobo rotation gobo indexing Channel 13 Iris Channel 14 Focus multistep zoom Channel 15 Shutter strobe Channel 16 Dimmer Pan Tilt Pan movement range 530 Tilt movement range 280 8 16 bit movement resolution Automatic Pan Tilt position correction Maximum PAN movement 530 in 2 65 s Maximum TILT movement 280 in 1 68 s Rigging Stands directly on the floor Mounts horizontally or vertically with 2 clamps 2 truss orientation Safety chain cord attachment bolt Temperatures Maximum ambient temperature t 40 C Maximum housing temperature t steady state 80 C Dimensions and weight Length of base inclu
27. nter to confirm or Mode to cancel and return to the menu 19 PAN TILT feedback This function allows to return the mowing head to the required position after changing the position by external force e g by stroke Use the Up and Down keys to select On if you wish to anable this function or Off if you wish not to return the mowing head to the required position and press Enter to confirm or Mode to cancel and return to the menu Note If the feedback was switched Off the pan tilt position is changed by external force and the feedbeck is switched On again the moving head might not to be synchronized with the DMX signal You have to make a reset in order to synchronize the moving head with the DMX signal Lamp Off via DMX This function allows you to switch Off the lamp by DMX Use the Up and Down keys to select On if you want to switch Off the lamp by DMX or Off if you don t want to switch Off the lamp by DMX and press Enter to confirm or Mode to cancel and return to the menu Temperature Temperature readouts of the fixture inside in Celsius Inside temperatures below 80 C are not critical 80 C and more lead to the lamp being switched off Please note that the outside temperature should not exceed 40 C Low fan speed operating By using this function you can choose 5 types of low fan speed operating Browse through this menu by the pressing Up and Down keys the display shows step by step these messages
28. strike types that means that they have to be cold before re striking For this reason you have to wait 5 minutes max speed of fan must be adjusted after having switched Off the lamp before you can switch it back On again If you try to switch On the lamp within 5 minutes after having switched it Off the ServoSpot 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired The message HEAt will appear on the control board display of the ServoSpot 575 If the ignition of the lamp is seven times unsuccessful on the display will appear LA Er meaning that the lamp could be damaged or even missed or there could be a failure on the ignitor or ballast 7 3 Colour wheels The ServoSpot 575 contains two colour wheels both with 10 color positions 9 of these with dichroic colors and the last one white The wheel 1 can be positioned between two adjacent colors in any position It is also possible to rotate the color wheel 1 continuously at different speeds Rainbow effect in both directions Hot and cold colour temperature filters 3200K and 5600K and UV filtr are situated on the colour wheel 2 By color macro function it is possible to obtain 64 different colours in following order white pink magenta red orange yellow green cyan blue UV 7 4 Static gobo wheel The wheel has 9 metal gobos plus an open position Adjustable gobo wheel rotation from slow to fast gobo shake function 7 5
29. sulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Always plug in the power plug last Make sure that the power switch is set to OFF position before you connect the device to the mains The power plug has to be accessible after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord This device falls under protection class Therefore it is essential to connect the yellow green conductor to earth The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this device to a dimmer pack Do not switch the fixture on and off in short intervals as this would reduce the lamp s life During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Do not touch the device s housing with bare hands during its operation housing becomes hot For rep
30. tion sensors failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The yoke is not located in the default position after the reset tiEr TILT head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The head is not located in the default position after the reset FrEr It will appear if the frequency of the mains is not standard 50 or 60Hz 10 Technical specifications Power supply EU model 208 230 240V AC 50 60Hz FUSE T 5 0A 230V US model 100 115 208 230V AC 50 60Hz ONE E 5 tasse T 10A 115V Power consumption 900 VA Lamp OSRAM HSR 575 2 95V 575W GX 9 5 750h PHILIPS MSR 575 2 95V 575W GX 9 5 750h or MSD 575 95V 575W GX 9 5 2000h Optical System High luminous efficiency parabolic reflector focus lens and multistep zoom lenses system 15 18 22 beam angles All lenses are anti reflection coated Beampath o o Beam angle 15 Beam angle 18 9600 2400 1070 600 LUX 8320 2080 930 520 LUX g 2 2 3 o o Q S a ca 0 5 10 15 20 Distance m 0 5 10 15 20 Distance m 0 1 18 2 36 3 55 4 73 Diameter m 0 1 43 2 86 4 29 5 72 Di
31. tton and press the Enter button Power On time By this option you can read the total number of hours that the ServoSpot 575 has been powered On Press Enter or Mode to return to the main menu Switch On Off the lamp Use the Up and Down keys to select On if you wish the switch On the lamp or Off if you wish switch Off the lamp and press Enter to confirm or Mode to cancel and return to the main menu 16 Demo sequences This function allows you to run a special demo test sequences without an external controller which will show you some possibilities of using ServoSpot 575 Press Up and Down keys to select the Mod1 or Mod2 sequences The Mod1 is suitable for projections on the wall ceiling or ground without any head movement the Mod2 uses all ServoSpot 575 functions and therefore is good for a complete introduction of the fixture 0 255 0 255 0 255 ren Reset Function Press Enter key to run reset This option enables the ServoSpot 575 to index all effects functions and return to their standard positions 8 2 SPEC Special functions Use the Up and Down keys to browse through the special functions and select the one by pressing Enter 17 Manual control of effects This function allows you to control manually the channel functions of the fixture Use the Up and Down keys to select desired function and press Enter to adjust the effect or Mode to cancel and return to the menu
32. wing below Fasten a safety chain to eye bolt The safety chain cord must hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Mounting plate 7 f s Eye bolt XAXXXXXX XX 7 l XX XD Dia y E 7 XX XX 2 XX Secure chain 4 5 Connection to the mains Connect the fixture to the mains with the enclosed power plug The earth has to be connected The occupation of the connection cables is as follows cable pin international Brown Live Blue Neutral Yellow Green Earth 4 6 DMX 512 connection connection between fixtures The wires must not come into contact with each other otherwise the fixtures will not work at all or will not work properly gt gt dea des K lt el Wo ay a E ci oO Se a Se lt DMX512 I 120Q 7 Only use a stereo shielded cable and 3 pin XLR plugs and connectors in
33. x speed vector mode black out while pan tilt step moving or color gobo changes Lamp on off reset fans speed control From max speed of fan to min speed of fan proportional Lamp on reset step No function step Lamp off after 3 sec step No function step Colours 1 Open white proportional Light blue proportional Red proportional Blue proportional Light green proportional Yellow proportional Magenta proportional Cyan proportional Green proportional Orange proportional Forwards rainbow effect from fast to slow proportional No rotation step Backwards rainbow effect from slow to fast proportional Colour macro function channel 8 set from 128 proportional 255 64 different colours in following order white pink magenta red orange yellow green cyan blue U Colours 2 White Deep red Deep blue Pink Cyan Magenta Yellow 5600K correction filter 3200K correction filter UV filter 11 hannel Channel Value Type of control 16 bit 8 bit 120 127 White step 128 255 Enable macro color function on channel 7 step 3 facet prism rotatin control Prism macros Open position no prism step Forwards rotation from fast to slow proportional No rotation step Backwards rotation from slow to fast _proportional Prism gobo macros Macro 1 step Macro 2 step Macro 3 step Macro 4 step Macro 5 step Macro 6 step Macro 7 step Macro 8 step Macro 9 step Macro 10 step Macro 11 step Macro 12 step Macro 13 step Macro 14 st