Home

User manual Arc Power Smart White 144

image

Contents

1. e oas MES atta con 0 255 LED saturation control 0 100 proportional A alols Cool white LED 2 0 255 LED saturation control 0 100 proportional DIMMER 2 0 255 Dimmer intensity from 0 to 100 proportional Ratio control 2 0 127 100 Warm white LED saturation step 2 0 127 Cool white LED saturation 0 gt 100 proportional 128 255 100 Cool white LED saturation step 128 255 Warm white LED saturation 100 gt 0 proportional ONE sfl 8 17 oas MES stator con 0 255 LED saturation control 0 100 proportional gt Cool white LED 3 0 255 LED saturation control 0 100 proportional DIMMER 3 0 255 Dimmer intensity from 0 to 100 proportional Ratio control 3 0 127 100 Warm white LED saturation step 3 0 127 Cool white LED saturation 0 gt 100 proportional 128 255 100 Cool white LED saturation step 128 255 Warm white LED saturation 100 gt 0 proportional ONE SS 7 7 pr rl oas MES saarn con 0 255 LED saturation control 0 100 proportional o 141 Cool white LED 4 0 255 LED saturation control 0 100 proportional 12 DIMMER 4 0 255 Dimmer intensity from 0 to 100 proportional Ratio control 4 0 127 100 Warm white LED saturation step 4 0 127 Cool white LED saturation 0 gt 100 proportional 128 255 100 Cool white LED saturation step 128 255 Warm white LED saturation 100 gt 0 proportional 12 Common channels for all Zones SHUTTER STROBE 0 31 Shutter
2. 240V AC 50 60 Hz Fuse T3 15A H Max Pover Consumption 240 VA Input Control DMX connection RS 232 connection DMX channels Mode 1 8 channels Mode 2 1 channel Mode 3 5 channels Mode 4 10 channels Mode 5 3 channels Mode 6 12 channels DMX 512 or Dynet RJ45 9 pin D connector Output 4 LED Outputs Max Output Voltage 48V DC Max Output current per zone 350mA per channel Max load per zone 36 LED s Total load 144 LED s Maximum total cable length between one LED zone output all its connected LED modules 80 metres at max load Control and programming Protocol USITT DMX 512 DMX modes 5 Control options DMX Auto trigger Operation modes Master Slave Stand alone Programs Display 3 digit LED White colour balance adjusting Manual control of all DMX channels by LED control panel Operating temperature 10 C 40 C Weight 2 9 kg Dimensions mm 2 Built in programs 1 user editable program up to 30 steps 291 2 la ooo AAA ET T D Da a A 20 uy Accessories Cable joiner No 13050691 4 pieces Optional accessories Adaptor RJ45 DMX 3 pin No 13050730 Adaptor RJ45 DMX 5 pin No 13050731 11 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower SmartWhite 144 with a fitting screwdriver from the housing anti clockw
3. Negative two s compliment of the preceding 7 bytes Example 1 0x1C 0x10 0x00 0x80 0xff 0x05 0xff 0x52 This would control channel 1 i e Red of Arcpower unit address 16 to a Level of 100 with a fade of 5 seconds Example 2 0x1C 0x05 0xCC 0x82 0xff 0x0A 0xff 0x52 This would control channel 3 i e Blue of Arcpower unit address 5 to a level of 20 with a fade of 10 seconds 10 6 Control menu map Default settings Bold print 001 503 PrG EPI P 01 P 02 Aut OFF On Edl epa S 01 S 30 End VAr 0 255 diM 0 255 FA t 0 255 S tl 0 255 COP MAn VAr 0 255 COL 0 255 VA2 0 255 CO4 0 255 Str 0 255 diM 0 255 tSt Y gt MSt P02 SLA VEr d MP Mo 1 Mo 2 Mo 3 Mo 4 Mo 5 Mo 6 Zon Z 0 Z6 1 0L On Off Prt dMH dYn C Li VAr 128 255 Col 128 255 Co4 128 255 UPd No YES 11 7 ArcPower SmartWhite 144 DMX protocol Version 2 0 software version 2 0 and higher u y TEE ONE o 4 4 4 4 Warm white LED 1 0 255 LED saturation control 0 100 proportional gt ololo Cool white LED 1 0 255 LED saturation control 0 100 proportional 3 DIMMER 1 0 255 Dimmer intensity from 0 to 100 proportional Ratio control 1 100 Warm white LED saturation step 1 Cool white LED saturation 0 gt 100 proportional 100 Cool white LED saturation step 128 255 Warm white LED saturation 100 gt 0 proportional ONE LL Le
4. closed step 32 63 Shutter open step 64 95 Strobe effect from slow to fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences from slow to fast proportional 144 159 Closing pulses in sequences from fast to slow proportional 160 191 Shutter open step 192 223 Random strobe effects from slow to fast proportional 224 255 Shutter open step TVE lO CommonchannelsforallZones OoOO S o 5 1013 DIMMER 0 255 Dimmer intensity from 0 to 100 proportional 4 All LEDs 0 255 All LEDs saturation control 0 100 proportional Ratio control 100 a _ LED saturation g 128 255 DMX Oo The mode 2 is suitable for control of single colour modules e g ArcLine Optic12 R ArcLine Optic 24 G ArcLine Optic 36 CW 13 8 Control board The control panel situated on the top cover of the ArcPower SmartWhite 144 allows pila DMX addressing calling Built in programs and setting the fixture behaviour Control elements ENTER button enters menu confirms adjusted values and leaves menu ee UP button and DOWN button moves between menu items on the the same level 0 sets values lt l A y In order to leave the menu without saving value press UP and DOWN at the same time After switching on the ArcPower SmartWhite 144 the display shows the initial DMX address Use UP DOWN to browse through the menu To select a function or submenu press ENTER 8 1 Addressing
5. current program step to the next prog step select option COP and confirm it by pressing ENTER Both Fade time and Standing time use the same conversion table in order to convert DMX values DMX values to time values DMX Time DMX Time DMX Time DMX Time DMX Time sec min min min min o1 fso f a2 a 1a feof 427 as m mo f s2 225 s44 Exact expression of the time value follows the formula time sec DMX value 10 8 3 Manual mode flan This menu gives access to the control of the fixture channels by means of the control buttons Use UP and DOWN buttons until the display shows MAn menu Press ENTER button and by using UP and DOWN buttons select desired effect press ENTER and and by using UP and DOWN buttons adjust desired DMX value for selected effect Confirm by ENTER VAr a warm white LEDs 1 saturation value 0 255 VA2 a warm white LEDs 2 saturation value 0 255 COL a cool white LEDs 1 saturation value 0 255 CO2 a cool white LEDs 2 saturation value 0 255 VA3 a warm white LEDs 3 saturation value 0 255 VA4 a warm white LEDs 4 saturation value 0 255 CO3 a cool white LEDs 3 saturation value 0 255 CO4 a cool white LEDs 4 saturation valu Str a strobe value 0 255 dim a dimmer value 0 255 8 4 Test sequences ESE Use the item to run a special demo test sequences without an external controller which will show you some possibilities of using the fix
6. proper trans mission on the data link 5 Connect fixtures to the mains 6 Select the DyNet protocol on all fixtures menu SPE gt dYn Control panel O Q O ad O L a J D a gt a ArcSource or ArcLine Module ju A L a L Connected pins Pin2 12V Pin6 Data Pin7 Data 7 Pin8 GND Cable joint i i i ey 1 i 1 O C gt MUOOODOOOOOOOOOOOOOOOO00000001 LD E WD DJ Splitter RJ 45 patch cable Fixture 32 A NM M M a SSS Te z ny a Terminator 120 Ohm A description of each byte in DyNet protocol is the following Byte 0 1C hexadecimal Logical Message fixed value Byte 1 01 Area Byte 2 00 Channel level Byte 3 80 Channel Byte 4 ff Channel Offset Byte 5 00 Fade Rate Byte 6 FF fixed value Byte 7 1C Checksum Area 0 to 255 as set on the Arcpower to give a unique address for each Arcpower unit i e DMX base address Channel Level 0 to 255 level 01 100 FF 0 Channel 80 to 83 80 channel 1 81 channel 2 82 channel 3 83 channel 4 see Channel Offset if more than 4 channels Channel Offset 0 255 default FF channel offset in blocks of 4 FF CH 1 4 00 CH 5 8 01 CH 9 12 etc up to 3E CH 253 256 Fade Rate 0 255 fade rate with 1 second resolution O 0 seconds 255 255 seconds Checksum 0 255 checksum Byte used to ensure the integrity of the packet
7. the ArcPower SmartWhite 144 00 H The fixture can be operated in the two modes DMX mode fixture is controlled via DMX 512 by an external DMX controller Stand alone mode fixture uses Built in programs and is able to control other fixtures in the master slave chain See the chapter Stand alone mode for detail description For DMX mode it is important to define the starting DMX address from which the ArcPower 36 will respond to the DMX controller Setting the DMX start channel for DMX operating 1 Connect ArcPower SmartWhite 144 to the mains 2 Browse through the menu by pressing the UP and DOWN buttons until the display shows current addres 001 Confirm by pressing ENTER button and 001 will start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing ENTER After having addressed ArcPower SmartWhite 144 you may now start operating ArcPower SmartWhite 144 via your DMX controller 8 2 Program running P G By entering this menu a complete overview of all programs is offered from which the program to be run can be selected by pressing ENTER Selected program runs in a loop The fixture includes 2 built in programs P 01 P 02 and one free editable program E P 1 up to 30 steps If tem AUt is On the fixture in DMX mode will remember last running program and this program will run after switching on the fixture Each program step has a fade time the time during
8. to select desired channel modes Mo 1 Mo 6 and press ENTER to confirm For detail description of all channels see DMX protocol Zon Zone selecting The option enables select desired number of the zone from 0 to 6 The number of the zone distinguishes individual zones of the ArcPower SmartWhite 144 which is controled via RS 232 interface Use UP and DOWN buttons to select desired zone and press ENTER to confirm selection The selected zone number is assigned to the first LED output and the second one has its zone number by one number higher etc Zon 0 LED outputs Zon 6 LED outputs Zone0 Zonet Zone2 Zone3 Zone6 Zone7 Zone8 Zone9Y aes EAE LDL Initial blink If this function is on ArcPower SmartWhite 144 makes auto calibration All LEDs light on 100 for short time after switching it on If this function is set off you have to set manually every colour on max brightness after switching on the driver before starting regular operating This action should last min one second In this moment the ArcPower SmartWhite 144 finds out the load connected to its LED output and makes auto calibration Prt Protocol selection Selects a required communication protocol dMH the fixture will communicate using DMX 512 signal dYn the fixture will communicate using the DyNet protocol C Li Current limiting The menu item allows to reduce a current carrying capacity of each LED branch col our in order to keep
9. window When the update is finished the line with the text The fixture is successfuly updated will appear in this window and the fixture will reset with the new software Note In the case of interruption of the upload process e g power cut the fixture remains in the update mode and you have to repeat the software update again For example The fixture was switched off before finishing software upload After switching the fixture on again the fixture is still in the update mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 17 9 Control of the ArcPower SmartWhite 144 via RS 232 9 1Wiring an RS 232 serial port 9 pin D connector male Front view of the socket Pin 1 Not connected Pin 2 Received Data Pin 3 Transmitted Data 1 5 Pin 4 O Pin 5 Signal Ground 6 9 Pin 6 Pin 7 Pin 8 Pin 9 Not connected RS 232 cable 9 pin D connector female 9 pin D connector female ArcPower driver 4 H 5 O Po oo O O O A O Pin 1 Pin 1 Pin 2 Received Data Pin 2 Received Data Pin 3 Transmited data Pin 3 Transmited data Pin 4 Pin 4 Pin 5 Signal ground Pin 5 Signal ground Pin 6 Pin 6 Pin 7 Pin 7 Pin 8 Pin 8 Pin 9 Pin 9 The maximum cable length according to the standard is 15 metres or the cable length equals to a capacitance of 2500 pr 9 2 Selecting a zone The number of the zone distinguishes individual drivers which ar
10. DMX Output LED module Input Pin 9 Not connected Pin 1 Not connected Pin 1 Not connected Pin 1 Warm white LED 1 Pin 2 12V Pin 2 Not connected Pin 2 Cool white LED 1 Pin 3 Not connected Pin 3 Not connected Pin 3 Warm white LED 2 Pin 4 Not connected Pin 4 Not connected Pin 4 Cool white LED 2 Pin 5 Not connected Pin 5 Not connected Pin 5 Warm white LED 1 Pin 6 Data Pin 6 Data Pin 6 Cool white LED 1 Pin 7 Data Pin 7 Data Pin 7 Warm white LED 2 Pin 8 GND Pin 8 GND Pin 8 Cool white LED 2 4 Installation 4 1 Connection to the mains The ArcPower SmartWhite 144 is equipped with auto switching power supply that automatically adjusts to any 50 60 Hz AC power source from 100 240 Volts Connect the ArcPower SmartWhite 144 to the mains with the power cord If the plug on the flexible cord is not the right type for your socket outlets do not use an adaptor but remove the plug from the cord and discard Carefully prepare the end of the the supply cord and fit a suitable plug The earth has to be connected Cord plug connections Cable EU Cable US Pin International Light blue This device falls under protection class I Therefore the ArcPower SmartWhite 144 has to be connected to a mains socket outlet with a protective earthing connection 4 2 Mounting the ArcPower SmartWhite 144 The ArcPower SmartWhite 144 should be be placed on a non f lammable f lat surface in any orientation and
11. USER MANUAL Version 2 0 ArcPower SmartWhite 144 Table of contents 1 S f ly INSUCHONS rios 4 2 Operating determinations rimas alicia 4 3 Description of the ArcPower SmartWhite 144 1 ttessceessesessseeeseceenseeeseecnnaseeeseeoensseeeseooenseeees 4 A WES TOU a E E 5 4 1 CONMCCTION TO TNE MAING nai 5 4 2 Mounting the ArcPower Smart White 14 sccccccccccccccssssssssssssseeensensensnessssssnssssssneseeneenenenennees 5 AS CONCCHON CADICS nao aaa 6 5 INStalna IN StructoOn setcccetsctnecescececcotencemneceamosesamncanmensodwnsentoerrauceancaae aora 7 Ost DMX OPeralO iden 7 5 2 Master Slave operating scccccccecsccescnncensecnneneeesecnsenennsneensaensneeneneeeenseasneneensenens 8 5 3 Operating via DyNet protocol scsocirocnareanaio ratero tna 9 6 Control m n Map sustancias proc tt NAA aR e eA a AAR 11 As AE e o 12 8 Oe ogc Mm DOAA aa 14 8 1 Addressing the ArcPower SmartWhite 144 tissssssssssccccccsssssensneneeennsesensnssssssssnsnsnsnnsssssnees 14 0 2 POOL TURTING en 14 0 3 Manta Mode sectoriales 15 0 4 TOST SOCQUCI CCS smart neos EEEE tica 15 8 5 Slanda al0ne MODO ima id a 15 9 6 gt Pecial PUC N rior Nina 16 9 Control of the ArcPower 36 via RS 23 ocooocccccocccooocncococanononcnnocencnnccnnancrnnanrrnnnanrrnnannrrnnanerenaanos 18 9 1Wiring an RS 232 Serial POM 1csssecccenscceneccnenscnensnensesenensnensesensssensnseonsesenssseesssensesenenss 18 92 SP CING A 18 9 3 Setting a serial port of Pd eee 18 9 4
12. ZOE COMMING Sarita ie isc cs 18 9 Technical Specificatii israel 20 10 Replacing the TUSO ssrosnicna sao a aa a aaia 21 CAUTION Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this product has to be qualilfied follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires inside the unit This product has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a Safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual To prevent from danger of accident the device has to be fixed on flat non f lammable surface in compliance with the installing instruction included in this manual Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the product Always ground the unit The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to have both overloa
13. a declared lifetime of LED modules The situation can occur if you operate LED modules at an higher ambient temperature than is recommended 40 C The current carrying capacity can be changed in a range of 350 175 mA 255 128 linearly A default value is 255 350 mA To adjust the current limiting 1 Browse through the menu by pressing the UP and DOWN buttons until the display shows C Li menu Press ENTER button and VAr item will appear on the display 2 Press ENTER button again and use UP and DOWN buttons to select desired value Confirm this value by pressing ENTER Use the UP and Down buttons to select next colour 3 Repeat step 2 for next items CoL VA4 Co4 UPd Software update Using this function you can update software in the fixture via PC and serial link The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ANOLIS distributor 16 Note 2 DMX address programs and all settings will be set to their default values To update software in the fixture Installation of DMX Software Uploader 1 DMX Software Uploader program is available from the ANOLIS web site at www anolis cz 2 Make a new directory e g Anolis_Uploader on your hard di
14. an demage the ArcPower SmartWhite 144 Maximum total cable length between one LED zone output of the Arcpower 144 and all its connected LED modules is 80 metres ArcSource module or ArcLine module Single ArcPower SmartWhite 144 installation RJ45 XLR cabl DMX Controller DMX address 1 ArcPower SmartWhite 144 eae o EAS Multiple ArcPower SmartWhite 144 installation Connect the DMX output of ArcSource module or ArcLine module the first ArcPower SmartWhite O a 144 with the DMX input of the AQ next ArcPower SmartWhite 144 Always connect one output with the input of the next ArcPower SmartWhite 144 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower SmartWhite 144 the data link bai D eae has to be terminated with a HEN gt y S terminator A termination plug is simply a RJ45 con nector with a 120 2 resistor between pins Data and Data Plug terminator in the DMX output of the last ArcPower SmartWhite 144 gt a RJ45 XLR CABLE 40 A ArcSource module or ArcLine module Maximum number of LEDs connected to the one ArcPower SmartWhite 144 zone is 36 Splitter O EY Terminator 120 ohm Maximum possible number of LED modules connected to the one zone of ArcPower SmartWhite 144 Max number of connected modules 5 2 Master slave operating 1 Unplug from the mains before installation 2 C
15. d and short circuit protection 2 Operating determinations This product was designed for indoor use only If the unit has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your unit Leave the unit switched off until it has reached room temperature Avoid brute force when installing or operating the unit When choosing the installation spot please make sure that the unit is not exposed to extreme heat moisture or dust Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fas tened The maximum ambient temperature 40 C must never be exceeded Operate the unit only after having familiarized with its functions Do not permit operation by persons not quali fied for operating the unit Most damages are the result of unprofessional operation Please use the original packaging if the product is to be transported Please consider that unauthorized modifications on the unit are forbidden due to safety reasons 3 Description of the ArcPower SmartWhite 144 1 Fuse Holder 2 Power Cord 3 Control Board 4 Power Indicator 5 DMX Output 6 DMX Input 7 LED Zone Outputs 8 RS 232 Input RS232 Input Canon 9 pin male Pin 1 Not connected RJ45 socket Pin 2 Received Data Pin 3 Transmitted Data Pin 4 Pin 5 Signal Ground Pin 6 Pin 7 Pin 8 DMX Input
16. e controled via RS 232 interface Select SPE in main menu of the ArPower SmartWhite 144 press ENTER use UP and DOWN buttons to select Zon The option enables to select desired number of the zone from O to 6 Press ENTER use UP and DOWN buttons to select zone number and press ENTER to confirm selection 9 3 Setting a serial port of PC The serial port of your personal computer hould be configured as follows 9600 Baud 8 Data Bits Non Parity One Stop Bit No Flow Control Required 9 4 Zone commands The ArcPower SmartWhite144 uses the 2 types of the zone commands which can be used in a suitable soft ware running on PC All zone commands stated below have to be send to the ArcPower SmartWhite 144 in ASCII codes Type 1 Selection of the preset colours The syntax of the command is zone Z warm zone Z cool 18 zone Z blackout Dedos means number of the zone 0 6 warm cool determines colour blackout closes light output dia means end of character sequence Examples zone 4 warm zone O blackout Type 2 Colour mixing The syntax of the command is zone Z w c 7 ee means number of zone 0 6 Wisin means DMX value of the warm white colour 0 255 us means DMX value of the cool white colour 0 255 Sy das means end of character sequence adn values of colours have to be separated by a comma Examples zone O 234 65 zone 1 5 28 19 10 Technical Specifications Power supply Input Voltage 100
17. fixed by the two screws There are 4 mounting holes of 5x7 mm in housing of the driver Flat surface 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower SmartWhite 144 to the DMX controller If your DMX controller has RJ45 socket for DMX output use RJ45 patch cable for connection with the ArcPower Smart White 144 RJ45 plug View facing pins Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Not used Not used Not used Not used Not used Data Data GND Screws Screws Mounting holes DMX 512 XLR plug male Front view of the plug Pin 1 GND Pin 2 Data Pin 3 Data Pin 4 Not used Pin 5 Not used 2 RJ45 patch cables category 5 that connect the ArcPower SmartWhite 144 each other are wired 1 1 that is pins with the same numbers are connected together Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Not used Not used Not used Not used Not used Data Data GND Not used Not used Not used Not used Not used Data Data GND 5 Installing instructions 5 1 DMX operating 1 Unplug from the mains before installation 2 Connect the LED modules to the fixture 3 Connect DMX controller to the fixture 4 Connect the fixture to the mains 5 Set the DMX address on the control board of the fixture see chapter Control board Warning Accidental connection DMX 512 Input Output to non DMX 512 device e g Ethernet network Hub c
18. ise 3 Remove the old fuse from the fuse holder 4 Install the new fuse in the fuse holder 5 Replace the fuse holder in the housing and fix it Specifications are subject to change without notice 21 22
19. onnect the LED module to the fixtures 3 Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected Up to 32 fixtures can be con nected in master slave chain 4 Insert the termination plug with 120 Ohm into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link 5 Connect the fixtures to the mains 6 See chapter Stand alone mode in order to set the fixture as a master or slave ArcSource module or ArcLine module Terminator 120 ohm TY TY O Master Y COO Oo O_O A Cable Joint pa Slave 30 MU ll RJ45 PATCH CABLE 0 El E Splitter r ae l oa lt L oO mm e i gt o O DAOOOODOOOINIDI e Terminator 120 ohm 5 3 Operating via DyNet protocol 1 Unplug from the mains before installation 2 Connect LED modules to the fixtures Connect first fixture to the control panel which uses DyNet protocol e g DLP 8100 3 Connect the DMX output of the first fixture in a data link with the DMX input of the second fixture Always connect output with the input of the next fixture until all fixtures are connected Up to 32 fixtures can be con nected in data chain 4 Insert the termination plug with 120 Ohm into DMX output of the last fixture in order to ensure
20. sk and download the software to it 3 Unpack the program from the archive Program file has name DSU_name of corresponding fixture_SoftwarelD SoftwarelD describes the versions of fixture software included in DMX Software Uploader Higher number means later software versions Fixture software updating 1 Determine which of your COM port is available on your PC and connect it with to the DMX input of the fixture using the Flash cable Do not extend this cable Disconnect the fixture from the other fixtures in DMX chain Turn on the computer and the fixture Switch the fixture to the update mode by selecting the option Software update in menu Special Functions on the fixture control panel SPE gt UPd gt yES From this option you cannot return back to the main menu If you do not want to continue in software update you have to switch off and on the fixture to leave this option It is recommended that you exit all programs before running the Software Uploader Start the Software Uploader program Select desired COM and then click Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update All processors will be updated including processors with the same software version lf you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process Update status is being displayed in the list
21. ture The sequences are the same for all zones 8 5 Stand alone mode Select this menu to set fixture behaviour in stand alone mode without an external controller Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MSt and the rest as the slaves SLA Only one fixture can be set as the master The slaves mimic the behavior of the master Effect actions are triggered by an internal timer of the master fixture Important Disconect the fixtures from the DMX controller before master slave operating otherwise data col lisions can occur and the fixtures will not work properly MSt Master Enter this menu if you want to set the the fixture as a master 15 Use UP and DOWN buttons to select desired program and press ENTER to confirm selection SLA Slave Enter this menu if you want to set the the fixture as a slave The master fixture starts simultaneous program start in the other slave fixtures All fixtures are synchronized in every prog steps The fixtures run their programs repeatedly e g if master runs its program P01 all slaves will be executed program P01 too 8 6 Special functions Use this menu for special services VEr Software Version Select this function to read the number of the fixture software d MP DMX presetting The function makes possible to select from the 5 DMX channel modes Use UP and DOWN buttons
22. which effects go to the current step and a Standing time the time during which effects last in the current step Current step Fade time Standing time Programming procedure 1 Enter Edl menu 2 Press UP or DOWN to select the desired program which you wish to edit and press ENTER 3 Press UP or DOWN to select the desired program step S 01 S 30 and press ENTER 4 Press UP or DOWN to select the desired item and press ENTER button Now you can edit by using UP or DOWN buttons the DMX values selected item End a total number of the program steps value 1 30 This value you must set before start programming e g if you want to create program with 10 steps set End 10 VAr a warm white LEDs 1 saturation value 0 255 VA2 a warm white LEDs 2 saturation value 0 255 COL a cool white LEDs 1 saturation value 0 255 CO2 a cool white LEDs 2 saturation value 0 255 VA3 a warm white LEDs 3 saturation value 0 255 VA4 a warm white LEDs 4 saturation value 0 255 CO3 a cool white LEDs 3 saturation value 0 255 CO4 a cool white LEDs 4 saturation value 0 255 Following item are common for all zones Str a strobe value 0 255 dim adimmer value 0 255 14 FA t fade time value 0 255 S tl standing time value 0 255 COP copying the current prog step to the next prog step Press ENTER button to confirm adjusted value 5 Repeat steps 3 and 4 for next prog step If you want to copy