1. ON telegram Push button 2 Selection of function switch Number of objects one Triggering of status LED flashes when switch value obj A not equal to 0 Group addresses Address Name proposal Function WANA Room 001 Light On Off Light on off by the movement detector 1 1 2 Room 001 Light Status Feedback from actuator On Off 1 1 3 Room 001 Light Switch On Brightness independent switch on from push button 1 1 4 Room 001 Light Permanent OFF Auto Permanent OFF 1 Automatic 0 Application 2 0 0 0 0 4 ly Movement dependent automatic light control with manual control Technical specifications Fine tuning Some parameters can be changed to fine tune the solution to the building and specific requirements Parameter which may need to be adjusted are listed below our recommendation in brackets KNX PIR 180 2 20m The staircase timer delay time will be retriggered by every detected movement when the light is on The light will be switched off if no movement has been detected within the specified time fine tuning Parameter page Parameter Value Block 1 general gt Times Time base for staircase timer 1s 1h 1 min Block 1 general gt Times Time factor for staircase timer 1 255 25 Delay time Time base x Time factor The light will only be switched ON by movement if the brightness in the room is below the specified brightness threshold Note that the brightness is measured at t
2. SeeTool Solutions for KNX Office building segment Application 2 0 0 0 0 4 Movement dependent automatic light control with manual control Schneider Electric Application 2 0 0 0 0 4 Movement dependent automatic light control with manual control Lighting control functions Application combines two modes automatic and manual At automatic mode the light is automatically switched OFF or ON dependant on people s movement and existing brightness At manual mode the light can be switched permanently OFF or ON The manual ON will start the automatic movement detection Application areas The application is defined for single room offices and conference rooms where automatic control is important but manual control required as well e g during presentations It is also usable in all types of non occupied storage rooms and occasionally used rooms as it offers basic control of the lighting with an automatic movement detector and a manual control by push button gt Energy savings Lights will not remain on all night or even when not needed Energy savings are achieved by turning ON and OFF the lights automatically This reduces the time for the lights turned on and can lead to savings of 40 compared to installations without automatic function Future proof The application is prepared and defined for integration into a Building Management System if required through the open technology communication
3. he installation place of the detector Parameter page Parameter Value Block 1 general gt Brightness Brightness threshold 10 2000 lux 300 Power failure behaviour Relay state after bus voltage failure no change relay remains Relay state after bus voltage recovery opened light is OFF Application 2 0 0 0 0 4 ly Movement dependent automatic light control with manual control Technical specifications User manual The user manual provided for the application is an end users training material and can be installed at site when final submission is made Please do no forget to cut out this quick guide for the user and attach to the wall next to the entrance to the room Also make sure the customer is aware of the installed applications function Quick guide THIS ROOM IS EQUIPPED WITH AN AUTOMATIC MOVEMENT DETECTOR AND TWO PUSH BUTTONS Automatic mode operation e The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold It is automatically switched OFF when no movement is detected in the room and preset delay time has passed The light can also be switched ON independent of brightness by pushing button no 1 LED 1 indicates the status of the light in the room Manual mode e Push button no 2 affects a permanent OFF To turn the lights ON again push button no 1 has to be pressed The automat
4. ic mode with movement detection will start again After an automatic OFF the brightness depen dent switch ON will start at movement again LED 2 flashes when the manual mode is selected e Delay time is adjustable by KNX software Default is 25 min OFF MANUAL e The brightness threshold is also service adjustable by KNX software Default is 300 lux Schneider for your 06 10 Application 2 0 0 0 0 4 amp Electric customer 1SC02070_EN 6
5. ll start again After an automatic OFF the brightness dependent switch ON will start at movement again Components The application consists of one movement detector wall mounted one push button wall mounted and one DIN rail switch actuator mounted in the cabinet or close to the room MTN647393 KNX Switch actuator REG K 2x230 16 with manual mode Design ranges Frames not included Other designs and colours available EXXACT WDE002931 KNX Push button 1 gang ae WDE002959 KNX PIR 180 2 20m flush mounted Installation Movement detector recommended to be installed on the wall at a height of 2 20m functions Application 2 0 0 0 0 4 ly Movement dependent automatic light control with manual control Technical specifications Wiring diagram a Push button 1 gang plus WDE002931 KNX PIR 180 2 20m flush mounted WDE002959 System component Presence detection KNX Manual control KNX Switch actuator REG K 2x230 16 with manual mode MTN647393 things work together Application 2 0 0 0 0 4 Movement dependent automatic light control with manual control Technical specifications Configuration The ETS tool is used to set the parameters for the devices in the application and to define the functional relationship between the devices by group addresses The following parameters and group address relations must be set and assigned The parameters sh
6. network gt Flexibility For optimised cost the amount of units is reduced to a minimum but allows maximum of flexibility when walls are removed and rooms are combined Reliability Design planning and installation documents are pre defined which makes the entire building process faster and more reliable User documents and descriptions are prepared to assist in user training The application works as an individual stand alone room control unit and can be installed used alone or combined with the entire network Lighting EN 15232 A class solution tested amp validated Application 2 0 0 0 0 4 Movement dependent automatic light control with manual control JAN Technical specifications Functions Application has two modes automatic mode and manual mode Automatic mode The light is automatically switched ON when a person enters the room and the brightness value is below a predefined brightness threshold It is automatically switched OFF when no movement is detected in the room and preset delay time has passed The light can also be switched ON independent of brightness by pushing button no 1 Delay is adjustable by ETS software Default is 25 min The brightness threshold is also adjustable by ETS software Our recommendation is 300 lux Manual mode Push button no 2 affects a permanent OFF To turn the lights ON again push button no 1 has to be pressed The automatic mode with movement detection wi
7. ould be set first and in the described order The parameters which can be changed to fine tune the application are described further on KNX PIR 180 2 20m Switch actuator REG K 2x230 16 O Switch object1 Block 1 1 bit gt 1 1 1 1 1 1 gt O Switch object Channel 1 1 bit 7 Trigger object Block 1 1 bit lt 1 1 3 1 1 2 lt 3 Status feedback Channel 1 1 bit 8 Locking object Block 1 1 bit lt 1 1 4 Device selection Device selection 2 fold switch actuator 109 Status feedback Safety pause 1 bit lt 1 1 2 y settinas Block 4 i Channel 1 General g Ta slat a t d Status information active status resp object i eae a x me meo Relay state after bus Se enon chao voltage recovery opened Block 1 general gt Disable function Behaviour at start of block send telegram Block 1 general gt Brightness Brightness threshold 10 2000 Lux 300 Block 1 general gt Times Master triggering is brightness dep disabled Time base for staircase timer 1 min Time factor for staircase timer 1 255 25 KNX Push button 1 gang 0 Switch objectA PB 1 1 bit gt 1 1 4 i Switch object B PB 1 1 bit gt 1 1 3 2 Status feedback lt 1 1 2 obj PB1 1 bit 3 Switch objectA PB2 1 bit gt 1 1 4 Push button 1 Selection of function switch Number of objects two Triggering of status LED from status feedback object Object A Value OFF telegram Object B Value