Contents
1. Each bit within the byte indicates whether the corresponding relay is operated or not If the bit is 1 then the relay is operated if the bit is 0 then the relay is released Eg R55 relays 1 3 5 7 ON all others OFF ROF relays 1 4 ON all others OFF Sx relay STATUS where x relay number A 0 zero is returned if the relay is released 1 if operated The command S0 returns the status of ALL relays In this case a hex byte is returned Each bit within the byte indicates the status of the corresponding relay Eg S3 returns the status of relay 3 SO returns the status of ALL relays Ix INPUT status where x input number A 1 is returned if the input is enabled 0 otherwise The command 10 returns the status of ALL inputs As with the S command a hex byte is returned Bits 0 3 indicate the status of inputs 1 4 Bits 4 7 are unused and are set to 0 Eg IL returns the status of input 1 I0 returns the status of ALL inputs A special command will print the software date Audon Electronics 123 High Road Chilwell Nottingham NG9 4AT UK Phone 44 0 115 925 8412 Fax 44 0 115 925 9757 email info audon co uk Page 4
2. Nottingham NG9 4AT UK Phone 44 0 115 925 8412 Fax 44 0 115 925 9757 email info audon co uk Page 1 1 Terminal Emulator Program If you are running Windows then one is supplied with the operating system In Windows 3 1 it is called Terminal and in Windows 95 98 it is called HyperTerminal Of course there are a number of third party terminal emulator programs that will work just as well When using these programs the communication parameters need to be set for 9600 baud 8 data bits 1 stop bit no parity and no flow control Simply type the commands as detailed later SPO RLB 2 Windows Program Main About ACI SUDOR Electronics SPO RL8 Outputs Inputs Features RL aes a G 23 3 A Data Logging gt se O starsto RL3 Q ey E s The SPO RL8 comes with a Windows program e Manual control of each relay through use of RL2 fail Cy Toggle switch e Timer function each relay can be independently made to switch on or off at EN gt Reset File timed periods Unlimited on off times can be programmed 1 a Log Rate Different times for each day if required RLS eer Se Time settings can be saved in a setup file Virtual LED display of inputs Inputs can be logged to a ASCII text data file view in Notepad or Excel Adjustable log rate from 1 to 1000 s seconds For use with any COMM port e Compatible with Win 95 98 Me 2000 XP double click to edit times uA E In
3. SPO RL8 BOT DaR Sa Port Relay ELECTRONICS and Opto Input boar The SPO RL8 provides 8 relay and 4 optically isolated inputs for control and sensing applications It is controlled via a serial port using a set of simple text commands Connection to the real world is via pluggable type screw terminal blocks Power can be supplied via a 9 12V DC power supply such as a wall adaptor rated at 5 00mA minimum The SPO RL8 comes with a simple Windows compatible program to set the state of the relays and to display input status Specifications Relays e 8 Form C change over relays e Contact rating resistive load 15A 24VDC 15A 120VAC 10A 240VAC e Contact rating inductive load 5A 24VDC 5A 120VAC 5A 240VAC Isolated Inputs 4 isolated inputs minimum voltage 5V DC 5mA maximum voltage 24V DC 25mA Isolation 2500V peak 1775 RMS 1 second General e Power 9 12V 500mA via 2 1mm DC power socket ii centre pin ve Data and Power LED s Dimensions 140mm x 110mm x 35mm excluded screw terminals Serial port 3 way pin 2 pin 2 pin 3 gt pin3 pin 5 pin 5 maximum cable length gt 100m Format 9600 baud 8 data 1 stop no parity Operation There are 3 ways to communicate with the SPO RL8 from your computer 1 Using a terminal emulator program such as Hyper Terminal 2 The supplied Windows Program 3 Writing your own software Audon Electronics 123 High Road Chilwell
4. commands are used to control the relays return their status or read the inputs Each command consists of a string of ASCII characters followed by carriage return Enter J The character is output as a prompt to indicate the SPO RL8 is waiting for a command Each character received is echoed back On completion of each command good or bad a carriage return line feed combination is output followed by the prompt If the command or parameter is invalid the command is ignored and a is output before the next prompt Note e Commands are not processed until the carriage return character is received e Commands can be in upper or lower case e Relays are numbered 1 to 8 Relay number 0 zero indicates ALL relays e Inputs are numbered 1 to 4 Input number 0 zero indicates ALL inputs e Where a hex byte is used each bit within the byte indicates its corresponding relay or input Bit 0 indicates relay or input 1 bit 1 indicates relay or input 2 etc Nx Turn a relay ON where x relay number Eg N3 turn on relay 3 NO turn on ALL relays Fx Turn a relay OFF where x relay number Eg F3 turn off relay 3 FO turn off ALL relays Tx TOGGLE a relay on off where x relay number Changes the state of a relay ON to OFF OFF to ON Eg T3 toggle relay 3 TO toggle ALL relays Rhh Set ALL relays directly hh is a hexadecimal byte
5. ents are automatically listed in chronological order Complete timed sequences can be saved to a file by clicking on the Save Settings button on the main program window Likewise previously stored sequences can be recalled by clicking on the Load Setting button Operation Inputs The Software checks the status of the inputs twice a second and illuminates an appropriate LED if an input signal is detected The software also includes a data logger where the inputs are logged to a file called Digin log along with the date and time This is an ASCII text file which can be viewed in 66 99 Notepad or Excel the file uses the parameter separator character e Start Stop button starts or stops data logging e Reset File erases any existing data in Digin log e Log Rate enter a log rate value in seconds 3 Writing You Own Software The supplied program is written using ProfiLab software package available form Audon Electronics This is a low cost graphical programming package aimed at non programmers A Demo version is available on the supplied CD Visual Basic A VB example is also included on the CD The component Mscomm must be installed for this example to work Mscomm is freely available from the Microsoft web site Audon Electronics 123 High Road Chilwell Nottingham NG9 4AT UK Phone 44 0 115 925 8412 Fax 44 0 115 925 9757 email info audon co uk Page 3 Commands A set of simple text
6. stallation Create a directory on your PC and copy all the files from the CD in the folder SPO RL8 into it Run the program SPO_RL38 exe The screen as shown above will be displayed and the program will default to using COMM port 1 To change to another COMM port click on the Hardware Configuration button at the top right of the window or press the F6 function key A window will appear with 3 Serial port listings You must change all 3 by clicking on the Modify button Operation Outputs Manual Relay operation Move the mouse to a toggle switch and click You will see the toggle switch change position and the corresponding LED will illuminate to indicate that the Relay has been activated Timed Operation A timed weekly sequence can be set up for each relay Double click on the grey Timer panel to bring up the Timer window NOTE the toggle switch must be set to OFF for the timed output to work Audon Electronics 123 High Road Chilwell Nottingham NG9 4AT UK Phone 44 0 115 925 8412 Fax 44 0 115 925 9757 email info audon co uk Page 2 Week timer Alarm time If Af S mafo sf a Add gt gt gt Mo 5 N aga i d peters C we OEF Ge m seg uence aeir 853 ___ Delete C Sa Delete all Sy Preview Colour Hint Week timer System time ia Background Ti Click the Add button to add a new on off time You can set the event day time and whether the event is an on or off event The timed ev